ENGLISH
Operator’s Manual
MIRAGE® DROP-IN INDUCTION
RETHERMALIZERS
Item Description Voltage Watts Amps Plug
74702D
74703D
74704D
74705D
741102D
741103D
741104D
741105D
7 qt. Induction Drop-in Rethermalizer - Schuko
7 qt. Induction Drop-in Rethermalizer - UK
7 qt. Induction Drop-in Rethermalizer - China
7 qt. Induction Drop-in Rethermalizer - Australia
11 qt. Induction Drop-in Rethermalizer - Schuko
11 qt. Induction Drop-in Rethermalizer - UK
11 qt. Induction Drop-in Rethermalizer - China
11 qt. Induction Drop-in Rethermalizer - Australia
230 800 3.4 Schuko, EU1-16P, CEE7/7
230 800 3.4 UK, UK1-13P, BS1363A
230 800 3.4 China, CH1-10P
230 800 3.4 AU, AU1-10P, AS 3112
230 800 3.4 Schuko, EU1-16P, CEE7/7
230 800 3.4 UK, UK1-13P, BS1363A
230 800 3.4 China, CH1-10P
230 800 3.4 AU, AU1-10P, AS 3112
Thank you for purchasing this Vollrath Equipment. Before operating the equipment, read and familiarize yourself with the following operating
and safety instructions. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. Save the original box and packaging. Use this
packaging to ship the equipment if repairs are needed.
Item No. 2350231-1 en Rev 06/14
Safety PrecautionS
Before using this equipment it must be cleaned and dried thoroughly. This
equipment is not intended for household, industrial or laboratory use.
To ensure safe operation, read the following statements and
understand their meaning. This manual contains safety precautions
which are explained below. Please read carefully.
WARNING
Warning is used to indicate the presence of a hazard that can cause
severe personal injury, death, or substantial property damage if the
warning is ignored.
CAUTION
Caution is used to indicate the presence of a hazard that will or can
cause minor personal injury or property damage if the caution is
ignored.
NOTE
Note is used to notify people of installation, operation, or
maintenance information that is important but not hazard-related.
For Your Safety!
These precautions should be followed at all times. Failure to follow
these precautions could result in injury to yourself and others.
To reduce risk of injury or damage to the unit:
Plug only into grounded electrical outlets matching the nameplate rated
voltage. Each induction unit should have a separate circuit.
Do not use an extension cord with this equipment. Do not plug this
equipment into a power strip or multi-outlet power cord.
As a precaution, persons using a pacemaker should stand back 12”
ENGLISH
(30 cm) from an operating unit. Studies have shown that the induction
element will not disrupt a pacemaker.
Keep all credit cards, driver licences and other items with a magnetic
strip away from an operating unit. The unit’s magnetic eld will damage
the information on these strips.
Do not put water in the rethermalizer. It is intended to run dry. Water will
damage the unit and void the warranty.
Use only Vollrath induction-ready insets with this unit. Failure to use
Vollrath Induction-ready insets may damage unit and void the warranty.
Do not spray controls or outside of unit with liquids or cleaning agents.
Unplug when not in use.
Keep unit and power cord away from open ames, electric burners or
excessive heat.
Do not operate unattended.
Closely supervise units operating in public areas and/or around
children.
Do not operate if unit has been damaged or is malfunctioning in any
way.
unPacking the equiPment and inStallation
When no longer needed, dispose of all packaging and materials in an
environmentally responsible manner.
1. Remove all packing material and tape, as well as any protective plastic
from the equipment.
2. Clean any glue residue left over from the plastic or tape.
Have the unit installed only by qualied service personnel. The cutout
opening in counter must be in accordance with the chart below. All openings
must be within 1/8” of the stated dimension.
Model/Size Cut-out Opening
7 Quart 10-5/8” (27.0 cm) Diameter
11 Quart 12-5/8” (32.1 cm) Diameter
Control Box 2-5/8” (6.6 cm) x 5” (12.7 cm)
(stud locations shown below)
13/64”
(0.51)
5” (12.7)
2-5/8”
(6.6)
5-13/16” (14.8)
6-7/16” (16.4)
2-3/16”
(5.6)
3-1/16”
(7.8)
Figure 1. Control Panel Cutout
NOTE
All cutout openings must be within 1/8” of listed opening sizes.
3. Plug the power cord into a grounded electrical outlet with the matching
nameplate rated voltage.
NOTE:
Using a voltage other than the nameplate rated voltage will cause
damage to the unit. Incorrect voltage, modication to the power
cord or electrical components can damage unit and will void the
warranty.
oPeration
function and PurPoSe
The 800W models are intended and designed to rethermalize containers of
refrigerated, previously cooked food and hold containers of hot food at safe
serving temperatures. All Models are intended and designed to keep food
product at proper serving temperatures. For hot food holding food must be
prepared and placed in at proper serving tempratures. These units are not
designed to cook raw food.
Use only Vollrath induction-ready insets (item 88184 or 88204). Failure to
use Vollrath Induction-ready insets may damage unit and void the warranty.
This equipment is not intended or designed to cook raw food product.
2
OperatOr’s Manual
WARNING
Electrical Shock Hazard.
Keep water and other liquids from entering the
inside of the unit. Liquid inside the unit could cause
an electrical shock.
NOTE:
Pre-heat empty insets for 5 minutes or less when necessary.
Because of the speed and efciency of the induction range, insets
can very quickly overheat and be damaged.