Dear Customer
Your Vokera Mynute HE boiler has been designed to meet and exceed the very latest standards in gas central heating technology, and if cared for, will give years of reliable use and efficiency. Please therefore take some time to read these instructions carefully.
Do’s and Don’t’s
Do ensure that the system pressure is periodically checked
Do ensure that you know how to isolate the appliance in an emergency
Do ensure that you are familiar with the appliance controls
Do ensure that your installer has completed the appliance log book section
Do not attempt to remove the appliance casing or gain internal access
Do not hang clothes etc. over the appliance
Do not forget to have the appliance serviced annually.
This booklet is an integral part of the appliance. It is therefore necessary to ensure that the booklet is handed to the person responsible for the property in which the appliance is located/installed. A replacement copy can be obtained from Vokera customer services.
Contents
Introduction Page
Dear customer 2 Do’s and don’t’s 2
Things you should know Page
1.1 Gas appliances 3
1.2 Electrical supply 3
1.3 Guarantee registration card 3
1.4 Appliance log book (UK only) 3
1.5 How does it work? 3
1.6 Dimensions 3
1.7 Clearances required 3
1.8 Frost protection system 3
1.9 Status indicators 3
1.10 Digital display 4
Getting started Page
2.1 Before switching on 5
2.2 Appliance controls 5
2.3 Lighting the boiler 5
2.4 Adjusting the CH temperature 5
2.5 Adjusting the DHW temperature 5
How to... Page
3.1 Top-up the system 6
3.2 Reset the appliance 6
3.3 Shut down the system for short periods 6
3.4 Shut down the system for long periods 6
3.5 Care for the appliance 6
What if... Page
4.1 I suspect a gas leak 7
4.2 I have to frequently to top-up the system 7
4.3 The RED fault light is on 7
4.4 The appliance is due its annual service 7
4.5 I need to call an engineer 7
Setting the Vokera… Page
5.1 Mechanical clock 7
INTRODUCTION
3
THINGS YOU SHOULD KNOW
1.1 GAS APPLIANCES Gas Safety (Installations and Use) Regulations (UK).
In the interests of your safety and that of others it is a legal requirement that all gas appliances are installed and correctly maintained by a competent person and in accordance with the latest regula­tions.
1.2 ELECTRICAL SUPPLY
Please ensure that this appliance has been prop­erly connected to the electrical supply by means of a double pole isolator or un-switched socket, and that the correct size of fuse (3 AMP) has been fitted.
Warning: this appliance must be earthed!
1.3 GUARANTEE REGISTRATION CARD
Please take the time to fill out your guarantee registration card. The completed warranty card should be posted within 30 days of installation.
1.4
APPLIANCE
LOG BOOK (UK only)
A logbook section can be found at the rear of the appliance installation booklet. This important document must be completed during the installation/ commissioning of your boiler. All CORGI registered installers carry a CORGI ID card, and have a registration number. These details should be recorded in the Benchmark logbook section within the installation booklet. You can check your installers details by calling CORGI direct on 01256
372300. Failure to install and commission the appliance in accordance with the manufacturers instructions may invalidate the warranty. This does not affect your statutory rights.
1.5 HOW DOES IT WORK?
Your Unica HE boiler supplies heated water to your radiators and hot water to your hot water taps. The central heating is controlled via a time clock and any thermostats that your installer may have fitted. The boiler will light when it receives a request from the time clock via any thermostat that may be installed, or whenever a hot water outlet (tap) is opened. Your Unica HE boiler lights electronically and does not have a pilot light. In the unlikely event of a fault developing with your boiler, the supply of gas to the burner will be terminated automatically.
1.6 DIMENSIONS
1.7 CLEARANCES REQUIRED
ABOVE BELOW
LEFT SIDE
RIGHT SIDE
FRONT
150 mm 150 mm
50 mm
12mm
600 mm
1.8 FROST PROTECTION SYSTEM
The Unica HE is equipped with a built-in frost protection system, this enables the boiler to over­ride the time controls – even if switched off – and operate the burner and/or pump, should the temperature drop below 60C for the main and below 4°C for the DHW line. In particular the burner will be in ON status until the main temperature reaches 35°C for CH appliance and 55°C for DHW appliance.
Unica 28HE
HEIGHT 780mm WIDTH 400mm DEPTH 358mm
Unica 32/36HE
HEIGHT 780mm WIDTH 450mm DEPTH 358mm
Please note that the frost protection system is designed to protect the appliance only, should frost protection be required for the heating system, additional controls may be required.
When the frost protection system has been activated, ‘AF’ is displayed on the appliance LED display (see below).
NOTE
The frost protection system is reliant on the ap­pliance having a permanent electrical supply, and being in a non-fault condition.
1.9 APPLIANCE STATUS INDICATORS
Your boiler is equipped with 2 status LED indicators, the Green LED indicates that the flame is present, whilst the Red LED indicates the appliance has detected a fault.