VOKERA Linea Max HE, Linea Max User Instructions

THESE INSTRUCTIONS TO BE RETAINED BY USER
Vokèra is a licensed member of the Benchmark scheme which aims to improve the standards of installation and commissioning of domestic hot water systems in the UK.
Linea Max HE
Users Instructions
Linea Max USERS2
BEFORE A TTEMPTING TO LIGHT APPLIANCE PLEASE MAKE SURE THAT IT IS CHARGED UP WITH WATER WITH THE NEEDLE POINTING AT 1bar ON THE PRESSURE GAUGE ( 2 Fig.1 )
Gas Safety (Installation and Use) Regulations l998
In your own interests and that of safety, it is the law that all gas appliances are installed and serviced by a competent person in accordance with the regulation.
GAS LEAK OR FAULT
IF A F A ULT OR GAS LEAK IS SUSPECTED, TURN OFF THE APPLIANCE AND CONTACT YOUR INST ALLATION COMPANY , GAS SUPPLIER OR NEAREST VOKÈRA OFFICE.
LOGBOOK
A log book is supplied with the boiler.This important document must be completed by your installer during the Installation / commissioning of your boiler.Failure to install and commission the appliance to the manufacturers instructions may invalidate the warranty. This does not affect your statutory rights.
Please keep your logbook handy, as you will be asked to quote certain information from the log book should you need to con­tact Vokèra Ltd in the unlikely event of a problem occuring with your boiler.
Your Vokèra Linea Max is a central heating boiler supplying central heating and instantaneous domestic hot water only. In the winter when both Central Heating and Hot Water are needed the central heating circulation stops when hot water is being drawn off.This normally will not affect the level of heating.
Boiler Location
Clearances Minimum - above casing 20mm (3/4in) Minimum - In front 600mm (24in) Minimum - At sides 12mm (˚in from casing)
Any purpose provided ventilation openings must not be blocked, and should be checked periodically to ensure this.If the appliance is fitted in a compartment it should not be used as a storage cupboard (e.g.for food).
NEVER HANG CLOTHES ETC. OVER THE APPLIANCE.
1. Temperature/Fault Indicator.
2. Pressure Gauge.
3. Timeclock Aperture (optional).
4. Status LED green = normal, red = fault
5. Central Heating Temperature Control knob.
6. Mode Selector Switch.
7. Hot Water Temperature Control Knob.
WARNING: THIS APPLIANCE MUST BE EARTHED
Connection should be made to a 230v 50Hz supply. The appliance must be protected by a 3amp fuse if a 13amp (BS
1363) plug or fused spur is used.
To connect a plug: As the colour of the wires in the mains lead to this applian­ce may not correspond with the coloured markings iden­tifying the terminals in your plug, proceed as follows:-
The wire which is coloured green-and-yellow must be con­nected to the terminal in the plug which is marked with the letter E or by the earth symbol W or coloured green or green-and-yellow.
The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black
The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red.
INTRODUCTION
ELECTRICITY SUPPLY
Fig. 1
3
567 4
1
2
Linea Max USERS 3
1.0 Operation
1.1 OFF
Appliance will not activate if tap is turned on or heating timers/controls are operated. Frost protection is still active (see 1.3).
1.2 When the mode selector switch is selected (other than OFF), with no demand for heating or hot water the appliance will periodically light to preheat the domestic hot water thermal store. This is done to ensure that when a demand is made for domestic hot water the appliance is not cold, thereby reducing the wait for hot water, and maximising hot water production.
If the appliance is unused for 19 hours the moto­rised valve will operate one cycle, and the pump will run for a period of 1 minute automatically (provided the electrical supply to the appliance is on). This will help prevent these components becoming stuck if the appliance is not used for long periods.
1.3 Frost Protection
The appliance will automatically ignite in central heating mode if the appliance temperature drops to approximately 5°C.The appliance will continue to operate in central heating mode until it reaches approximately 40°C.
2.0 Hot Water Only
Ensure electricity supply is on. (Status LED indi­cating green).
2.1 With the boiler mode selector switch (6) turned to (Fig. 2) the main burner will ignite electronically whenever water is drawn from the tap.
2.2 Should the boiler fail to ignite the status LED will flash red (this will be accompanied by an error code showing at the the fault indicator (1) see
4.0
for list of error codes and remedies. For error codes 01 to 03 and 05 to 08:turn the mode selec­tor switch (6) to the reset position for a period of at least 10 seconds then turn back to the original position before drawing water again. The appliance will re-attempt ignition. Should lockout continue the appliance must be checked by a competent person.
2.3
The maximum water flow rate to the tap is set at a predetermined maximum delivery .The tempera­ture of water at the tap can be varied by adjusting the water flow rate at the tap up to the predeter­mined maximum. The hot water temperature con­trol knob (7) will govern the maximum temperatu­re. Turning the knob clockwise increases the set­ting, anticlockwise decreases setting. (Fig. 3) When the appliance is being used in the hot water mode the temperature/fault idicator (1) indicates the approximate temperature of the hot water leaving the appliance.
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Filling loop Filling/inlet valve
Gas Inlet