Your Eclipse boiler has been designed to meet and exceed the very latest standards in gas central heating technol­ogy, and if cared for, will give years of reliable use and efficiency. Please therefore take some time to read these instructions carefully.
Do’s and don’t’s
Do ensure that the system pressure is periodically checked
Do ensure that you know how to isolate the appliance in an emergency
Do ensure that you are familiar with the appliance controls
Do ensure that your installer has completed the appliance log book
Do not attempt to remove the appliance casing or gain internal access
Do not hang clothes etc. over the appliance
Do not forget to have the appliance serviced annually
Contents
Introduction Page
Dear customer 2 Do’s and don’t’s 2
Things you should know Page
1.1 Gas appliances 3
1.2 Electrical supply 3
1.3 Guarantee registration card 3
1.4 Appliance log book 3
1.5 Dimensions 3
1.6 Clearances 3
Getting started Page
2.1 Before switching on 3
2.2 Appliance controls 3
2.3 Lighting the boiler 3
2.4 Adjusting the operating parameters 4
2.5 Viewing the operating parameters 5
How to... Page
3.1 Top-up the system 5
3.2 Reset the appliance 5
3.3 Shut down the system for short periods 5
3.4 Shut down the system for long periods 5
3.5 Care for the appliance 5
What if... Page
4.1 I suspect a gas leak 6
4.2 I frequently have to top-up the system 6
4.3 The reset light is on 6
4.4 The appliance is due its annual service 6
4.5 I need to call an engineer 6
Setting the Vokera Page
5.1 Mechanical clock 6
5.2 Digital clock 6
INTRODUCTION
Pressure gauge
Vokera timeclock (optional)
LED 1 & 2
display
Status
Indicator
Reset
Mode Step Store
+ -
Store
Reset
Mode
Step
-
Press to access parameter adjustment (fixed decimal point)
Press to view parameters
Press to store new setting
Press to raise setting
Press to lower setting
Press to reset boiler when lockout occurs
+
Fig. 1
THINGS YOU SHOULD KNOW
1.1 GAS APPLIANCE
Gas Safety (Installations and Use) Regulations. In the interests of your safety and that of the others it is a legal requirement that all gas appliances are installed and correctly maintained by a competent person and in accordance with the latest regulations.
1.2 ELECTRICAL SUPPLY
Please ensure that this appliance has been properly connected to the electrical supply by means of a double pole isolator or un-switched socket, and that the correct size of fuse (3 amp) has been fitted.
Warning: this appliance must be earthed!
1.3 GUARANTEE REGISTRATION CARD
Please take the time to fill out your guarantee registration card. The completed warranty card should be posted within 30 days of installation.
GETTING STARTED
2.1 BEFORE SWITCHING ON
Before switching the appliance on, please familiarise yourself with:
how to isolate the appliance from the gas,
water and electricity supplies;
how to check and top-up - if necessary - the
system water pressure;
the time clock;
any external thermostats and their functions;
the appliance controls.
2.2 APPLIANCE CONTROLS (fig. 1)
The appliance controls are concealed behind the front flap. To gain access to the controls simply pull the flap towards you in a downward motion. The appliance is equipped with a simple keypad that can be used to alter or display the following functions:
the outlet flow temperature to the central heating
system;
switch on or off the boiler.
The pressure gauge shows the current pressure of the system, the gauge should be set between 1 and 1.5 bar. When the appliance is operating the gauge may rise or fall slightly, this is quite normal. The minimum permissible level for the safe and efficient operation of the appliance is 0.5 bar. Should the pressure fall below 0.5 bar, the boiler may lockout.
Depending on the type of controls specified by your installer you may have an integral Vokera time clock fitted to the appliance, if so, instructions can be found on page 6-7. If an external time clock or programmer has been fitted, please refer to the instructions supplied with such.
2.3 LIGHTING THE BOILER
Ensure the gas and electrical supply to the boiler are turned on.
When there is a demand for heating via the timeclock or programmer, the boiler will go through an ignition sequence, whereby the burner will light.
If the appliance fails to ignite during the ignition sequence, it will re-attempt ignition several times before going to a lockout condition. Should this occur, please allow a period of two minutes before re-setting.
When the appliance reaches the set temperature, the burner will go off for minimum period of approximately 3 minutes.
When the programmer/time clock or external thermostats heating request has been satisfied, the appliance will switch off automatically.
2.4 ADJUSTING THE OPERATING PARAMETERS (see fig. 1 & 1A)
Usually your installer will have adjusted the operating parameters to suit your requirements, however should you wish to alter the operating parameters, please use the following procedure:
press the MODE button repeatedly until you
see a fixed decimal point in LED 1;
press the STEP button repeatedly until the parameter
that is to be adjusted is shown in LED 1;
use the adjustment buttons (+/-) to alter the
current setting as shown in LED 2;
press the STORE button to store the new
setting into the memory;
press the MODE button repeatedly until no
decimal point is shown in LED 1.
1.4 APPLIANCE LOG BOOK
A log book is supplied with the boiler. This important document must be completed during the installation/ commissioning of your boiler. Failure to install and commission the appliance in accordance with the manufacturers instructions may invalidate the warranty. This does not affect your statutory rights.
1.5 DIMENSIONS
HEIGHT
WIDTH DEPTH
790 mm 450 mm 322 mm
1.6 CLEARANCES REQUIRED
ABOVE
BELOW
SIDES
FRONT
150 mm 150 mm
25 mm
600 mm
To switch the central heating ON or OFF (00 = OFF, 01 = ON) press the STEP button until LED 1 shows 3.
Use the adjustment buttons (=/-) to alter the current value to the new value.
Press the STORE button to save the new value.
Press the MODE button until no decimal point is shown in LED 1.
To change the central heating flow temperature (variable between 20°C and 90°C) press the STEP button until LED 1 shows 4.
Use the adjustment buttons (=/-) to alter the current value to the new value.
Press the STORE button to save the new value.
Press the MODE button until no decimal point is shown in LED 1.
PRESS MODE BUTTON UNTIL A FIXED DECIMAL POINT IS SHOWN IN LED 1
Fig. 1A
Fig. 2
LED 2 shows flow tempe­rature
LED 2 shows return temperature
LED 2 shows temperature setting
2.5 VIEWING THE OPERATING PARAMETERS
Press MODE button until a flashing decimal point is shown in LED 1.
Press STEP until LED 1 shows 1
Press STEP until LED 1 shows 2
Press STEP until LED 1 shows 6
HOW TO...
3.1 HOW TO TOP-UP THE SYSTEM PRESSURE (fig. 3)
The system pressure must be checked periodically to ensure the correct operation of the boiler. The needle on the gauge should be reading between 1 and 1.5 bar when the boiler is in an off position and has cooled to room temperature.If the pressure requires ‘topping-up’ use the following instructions as a guide.
Locate the filling valve connections (usually
beneath the boiler).
Attach the filling loop to both connections.
Open the filling valve slowly until you hear
water entering the system.
Close the filling valve when the pressure gauge
(on the boiler) reads between 1 and 1.5 bar.
Remove the filling loop from the connections.
3.2 HOW TO RESET THE APPLIANCE
When the status light is illuminated red, the appliance will require to be reset manually. Before resetting the boiler ensure that the pressure gauge is indicating the correct level. Allow a period of two minutes to elapse before pressing the reset button.
IMPORTANT
If the appliance requires to be reset frequently, it may be indicative of a fault, please contact your installer or Vokera Customer Services for further advice.
3.3 HOW TO SHUT DOWN THE SYSTEM FOR SHORT PERIODS
The system and boiler can be shut down for short periods by simply turning the time clock to the off position. It is also advisable to turn off the main water supply to the house.
3.4 HOW TO SHUT DOWN THE SYSTEM FOR LONG PERIODS
If the house is to be left unoccupied for any length of time – especially during the winter – the system should be thoroughly drained of all water. The gas, water, and electricity supply to the house should also be turned off. For more detailed advice contact your installer.
3.5 HOW TO CARE FOR THE APPLIANCE
To clean the outer casing use only a clean damp cloth. Do not use any scourers or abrasive cleaners.
Fig. 3
4.4 WHAT IF THE APPLIANCE IS DUE ITS ANNUAL SERVICE
Advice for tenants only
Your landlord should arrange for servicing.
Advice for homeowners Please contact Vokera Customer Services (0870 333 0220 (UK) or 05655057 (ROI) if you would
prefer a Vokera service engineer or agent to service your appliance. Alternatively your local CORGI registered engineer may be able to service the appliance for you.
4.5 WHAT IF I NEED TO CALL AN ENGINEER
If you think your boiler may have developed a fault please contact your installer or Vokera Customer Services (0870 333 0220 (UK) or 05655057 (ROI) have all your details to hand including full address and postcode, relevant contact numbers, and your completed appliance log book.
WHAT IF...
4.1 WHAT IF I SUSPECT A GAS LEAK
If you suspect a gas leak, turn off the gas supply at the gas meter, and contact your installer or local gas supplier. If you require further advice please contact your nearest Vokera office.
4.2 WHAT IF I HAVE TO FREQUENTLY TOP-UP THE SYSTEM
If the system regularly requires topping-up, it may be indicative of a leak. Please contact your installer and ask him to inspect the system.
4.3 WHAT IF THE RESET LIGHT IS ON
If the reset light is flashing res it indicates that the boiler has failed to ignite or has overheated, when this happens the boiler automatically shuts down and requires to be reset manually (see 3.2).
5.2.1 BEFORE PROGRAMMING
Gently press and release the ‘Res.’ button with a pencil or similar, this will clear the memory of all information. This should only be done when you want to change or insert a complete new pro­gramme.
5.2.2 SETTING THE TIME OF DAY
The ‘real time’ clock has to be set to the actual day of the week and time of day, to do this:
Press and hold the button (see fig 6).
Press the ‘Day’ button until the actual day shows
in the display (1= Monday, 2= Tuesday, 3= Wednesday, etc.).
If setting the clock during ‘British summertime’
press the ‘+/-1h’ button once (use a pencil or similar).
Press the ‘h’ button until the actual hour is
shown in the display.
Press the ‘m’ button until the actual minutes
are showing in the display.
Now release the button.
The ‘:’ symbol between the hours and minutes
display will start to flash, this indicates that the clock is now keeping time (see fig. 7).
5.1 VOKERA MECHANICAL CLOCK Setting the time
The time of day can be set by grasping the outer edge of the black dial and turning it in a clockwise direction until the correct time is in line with the white pointer.
Setting the ‘switching times’
The ‘ON’ periods are set by sliding the black tappets, adjacent to the time periods required, to the outer edge of the dial. The tappets that remain at the centre of the dial will be the ‘OFF’ periods.
The smallest switching time (ON or OFF) is 15 minutes.
To select ‘Timed’ mode move the selector switch in the middle of the clock face to the ‘ ‘ position.
To select ‘Constant’ mode move the selector switch in the middle of the clock face to the ‘I’ position.
To select ‘Off’ mode move the selector switch in the middle of the clock face to the ‘O’ position.
5.2 VOKERA DIGITAL CLOCK
The Vokera digital time clock will automatically switch your boiler on and off. It has a total of twenty different switching commands, consisting of ten ‘on’ commands and ten ‘off’ commands.
Each ‘on’ or ‘off’ command can be used to switch the boiler ‘on’ or ‘off’ at the same time:
Every day of the week
Monday to Saturday
Monday to Friday
Saturday and Sunday
Any particular day
VOKERA TIMECLOCKS
Fig. 4
ON period
OFF period
Selector
switch
Group of days On Off Commands
used Mon. to Fri. 06.00 09.00 2 Mon. to Fri. 16.00 21.00 2 Sat. & Sun. 08.30 10.30 2 Sat. & Sun. 17.00 23.00 2
Total 8 used
Commands ‘free’ 12 unused
Example
Fig. 5
Select button
Reset button
“British summertime” button
Hour button
Minute button
Display
Day button
Programme button
Clock button
VOKERA DIGITAL TIME CLOCK
Fig. 6 Fig. 7
5.2.3 ENTERING (on) COMMANDS
Repeatedly press the Prog. Button until the —
:— symbol appears in the clock display (see fig. 8).
Press the Day button until the desired group of
days or desired day is shown.
Press the ‘h’ button until the desired hour for
switching the boiler on is shown.
Press the ‘m’ button until the desired minutes
are shown.
Press the Select button until the symbol is
shown (see fig. 9).
Press the button.
5.2.4 ENTERING (off) COMMANDS
Repeatedly press the Prog. Button until the —
:— symbol appears in the clock display (fig. 4).
Press the Day button until the desired group of
days or desired day is shown.
Press the ‘h’ button until the desired hour for
switching the boiler off is shown.
Press the ‘m’ button until the desired minutes
are shown.
Press the Select button until the symbol is
shown (see fig. 10).
Press the button.
Once the programming has been completed you will have to press the Select button – once only – to the (on)
position if the boiler has been programmed to be ‘on’ at that particular time.
5.2.5 ADVANCING OR LOCKING PROGRAMME COMMANDS
By pressing the Select button you can advance the time clock to the next command setting (from ‘on’ to ‘off’ or ‘off’ to ‘on’) or lock the time clock to a particular command (‘on’ continuously or ‘off’ continuously).
- ON
- OFF
[ ] – ON CONTINUOUSLY
[ ] – OFF CONTINUOUSLY
Fig. 8 Fig. 9
NOTE
The actual time can be changed to account for British summertime by simply pressing then re­leasing the +/- 1h button.
HELPFUL HINTS
You can check and/or alter the programme
settings at any time by pressing the Prog button.
The number of unused ‘commands’ can be checked
by pressing the Prog button until FR is displayed alongside the number of unused commands.
In the event of a power failure, the clock has a
battery back-up. The programme will be held in the memory for approximately 2 weeks. Charging time is 70 hours.
Take a note of the settings you have pro-
grammed, as local power surges can some­times reset the memory of the clock.
Fig. 10
Vokèra Ltd.
4th Floor, Catherine House, Boundary Way, Hemel Hempstead, Herts, HP2 7RP
Email: enquiries@vokera.co.uk Web: www.vokera.co.uk
General Enquiries - Tel: 01442 281400 Fax: 01442 281460
Technical Advice - Tel: 0141 945 6810
Spare Parts - Tel: 0141 945 6820
After Sales Service - Tel: 0870 333 0220
Vokèra Ireland
West Court, Callan, Co Kilkenny
Tel: 056 55057 Fax: 056 55060
Vokèra Ltd. reserve the right to change the specifications without prior notice. Consumers’ statutory rights are not affected.
A Riello Group Company
energizing home heating
“Vokèra”
supports Benchmark
COLLECTIVE MARK