What was the determining factor for purchasing your new USSC appliance?_______
I have read the owner’s manual that accompanies this unit and fully understand the:
Installation
Operation and Maintenance of my new USSC appliance.
Print Name Signature Date
Please attach a copy of your purchase receipt.
Warranty not valid without a Proof of Purchase.
Warranty information must be received within 30 days of original purchase.
Detach this page from this manual, fold in half with this page to the inside and tape together. Apply a
stamp and mail to the address provided. You may use an envelope if you choose.
You may register online by going to www.Vogelzang.com
All information submitted will be kept strictly con dential. Information provided will not be sold for advertising purposes.
CUT HERECUT HERE
3
Contact information will be used solely for the purpose of product noti cations.
Fold HereFold Here
Fold Here
PLACE
STAMP
HERE
United States Stove Company
P.O. Box 151
South Pittsburg, TN 37380
4
CUT HERECUT HERE
Safety Precautions
IMPORTANT: Read this entire manual before install-
ing and operating this product. Failure to do so may
result in property damage, bodily injury, or even death.
Proper installation of this stove is crucial for safe and
efficient operation.
Install vent at clearances specified by the vent manu-
facturer.
Do not connect the pellet vent to a vent serving any
other appliance or stove.
Do not install a flue damper in the exhaust venting
system of this unit.
Use of outside air is not required for this unit.
Contact your local building officials to obtain a permit
and information on any additional installation restrictions or inspection requirements in your area.
Do not throw this manual away. This manual has
important operating and maintenance instructions
that you will need at a later time. Always follow the
instructions in this manual.
This appliance is designed for the use of pelletized fuel
that meet or exceed the standard set by the Pellet Fuel
Institute(PFI), The use of other fuels will void warranty.
Never use gasoline, gasoline-type lantern fuel, kero-
sene, charcoal lighter fluid, or similar liquids to start or
’freshen up’ a fire in this stove. Keep all such liquids
well away from the stove while it is in use.
A working smoke detector must be installed in the same
room as this product.
Install a smoke detector on each floor of your home;
incase of accidental fire from any cause it can provide
time for escape.
The smoke detector must be installed at least 15 feet
(4,57 M) from the appliance in order to prevent undue
triggering of the detector when reloading.
Do not unplug the stove if you suspect a malfunction.
Turn the ON/OFF SWITCH to ”OFF’ and contact your
dealer.
Your stove requires periodic maintenance and clean-
ing (see ”MAINTENANCE ”). Failure to maintain your
stove may lead to improper and/or unsafe operation.
Disconnect the power cord before performing any
maintenance! NOTE: Turning the ON/OFF Switch to
”OFF” does not disconnect all power to the electrical
components of the stove.
Never try to repair or replace any part of the stove un-
less instructions for doing so are given in this manual.
All other work should be done by a trained technician.
Do not operate your stove with the viewing door open.
The auger will not feed pellets under these circum-
stances and a safety concern may arise from sparks or
fumes entering the room.
Allow the stove to cool before performing any mainte-
nance or cleaning. Ashes must be disposed in a metal
container with a tight fitting lid. The closed container of
ashes should be placed on a non-combustible surface or
on the ground, well away from all combustible materials,
pending final disposal.
The exhaust system should be checked monthly during
the burning season for any build-up of soot or creosote.
Do not touch the hot surfaces of the stove. Educate all
children on the dangers of a high-temperature stove.
Young children should be supervised when they are in
the same room as the stove.
The hopper and stove top will be hot during operation;
therefore, you should always use some type of hand
protection when refueling your stove.
A power surge protector is required. This unit must be
plugged into a 110 - 120V, 60 Hz grounded electrical
outlet. Do not use an adapter plug or sever the grounding plug. Do not route the electrical cord underneath, in
front of, or over the heater. Do not route the cord in foot
traffic areas or pinch the cord under furniture.
The heater will not operate during a power outage. If a
power outage does occur, check the heater for smoke
spillage and open a window if any smoke spills into the
room.
The feed door must be closed and sealed during opera-
tion.
Never block free airflow through the open vents of the
unit.
Keep foreign objects out of the hopper.
The moving parts of this stove are propelled by high
torque electric motors. Keep all body parts away from
the auger while the stove is plugged into an electrical
outlet. These moving parts may begin to move at any
time while the stove is plugged in.
Do not place clothing or other flammable items on or
near this stove.
When installed in a mobile home, the stove must be
grounded directly to the steel chassis and bolted to
the floor. WARNING—THIS UNIT MUST NOT BE INSTALLED IN THE BEDROOM (per HUD requirements).
CAUTION—THE STRUCTURAL INTEGRITY OF THE
MOBILE HOME FLOOR, WALL, AND CEILING/ROOF
MUST BE MAINTAINED.
This appliance is not intended for commercial use.
CAUTION: Burning fuel creates carbon monoxide and can
be hazardous to your health if not properly vented.
* This appliance is a freestanding heater. It is not intended to be attached to any type of ducting. It is not a furnace.
* Pellet size may effect the actual rate of fuel feed and burn times. Fuel feed rates may vary by as much as 20%. Use PFI listed fuel for best results.
Dimensions
Height44.5 in. (1130mm)
Width23 in. (584mm)
Depth23.5 in. (597mm)
Weight245 lbs. (111.1kg)
Electrical Specifi cations
Electrical Rating110-120 volts, 60 HZ, 3.0 Amps
Watts (operational)180
Watts (igniter running)346
FUEL CONSIDERATIONS
Your pellet stove is designed to burn premium hardwood pellets that comply with Association of Pellet Fuel Industries
standards. (Minimum of 40 lbs density per cubic ft, 1/4” to 5/16” diameter, length no greater than 1.5”, not less than
8,200 BTU/lb, moisture under 8% by weight, ash under 1% by weight, and salt under 300 parts per million). Pellets
that are soft, contain excessive amounts of loose sawdust, have been, or are wet, will result in reduced performance.
Store your pellets in a dry place. DO NOT store the fuel within the installation clearances of the unit or within the space
required for refueling and ash removal. Doing so could result in a house fi re.
Do not overfi re or use volatile fuels or combustibles, doing so may cause a personal and property damage hazards.
SAFETY AND EPA COMPLIANCE
Your pellet stove has been approved for installation in the USA and Canada. It may also be installed in a
manufactured or mobile home. Your stove conforms to ASTM E 1509, 2004, and Certifi ed to ULC S627, 2000,
and(UM) 84-HUD by INTERTEK Testing Services in Fairview, Oregon USA.
6
7
INSTALLATION OPTIONS
Read this entire manual before you install and use your pellet stove. Failure to follow instructions may result
in property damage, bodily injury, or even death!
(See specifi c installation details for clearances and other installation requirements)
A Freestanding Unit—supported by pedestal/legs and placed on a non-combustible fl oor surface in compliance with
clearance requirements for a freestanding stove installation.
An Alcove Unit—supported by pedestal/legs and placed on a non-combustible fl oor surface in compliance with clearance
requirements for an alcove installation.
Your pellet stove may be installed to code in either a conventional or mobile home (see SPECIAL MOBILE HOME REQUIREMENTS). The installation must comply with the Manufactured Home and Safety Standard (HUD), CFR3280, Part
24.
It is recommended that only a authorized technician install your pellet stove, preferably an NFI certifi ed specialist.
DO NOT CONNECT THIS UNIT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.
The use of other components other than stated herein could cause bodily harm, heater damage, and void your warranty.
IMPROPER INSTALLATION: The manufacturer will not be held responsible for damage caused by the malfunction of a stove due to improper venting or installation. Call (800) 750-2723 and/or consult a professional installer
if you have any questions.
INSTALLATION
CLEARANCES
Your pellet stove has been tested and listed for installation in residential, mobile home, and alcove applications in
accordance with the clearances given in FIGURES 3-6 and TABLE 1. For safety reasons, please adhere to the installation
clearances and restrictions. Any reduction in clearance to combustibles may only be done by means approved by a
regulatory authority.
FIGURE 3
SIDEWALL CLEARANCES
PARALLEL INSTALLATION
FIGURE 4
SIDEWALL CLEARANCES
CORNER INSTALLATION
PARALLEL A - Backwall to unit 3.00 / 76mm
B - Sidewall to fl ue 11.00 / 280mmC - Sidewall to top edge of unit 8.00 / 203mm
CORNER D - Adjacent wall to unit 8.00 / 203mm
ALCOVE E - Alcove depth 36.00 - 914mm
F - Alcove height 60.00 - 1520mm
TABLE 1
CLEARANCES
8
Installation
FLOOR PROTECTION
This heater must have a non-combustible fl oor protector (ember protection) installed beneath it if the fl oor is of com-
bustible material. If a fl oor pad is used, it should be UL listed or equal. The fl oor pad or non-combustible surface
should be large enough to cover at least the area under the product and 6 in. (152 mm) beyond the front and beyond
each side of the fuel loading and ash removal openings. Your heater will need a minimum 31” x 38” fl oor protector.
Floor protection must extend under and 2 in. (50.8mm) to each side of the chimney tee for an interior vertical installation (see FIGURE 2).
Canadian Installations require a minimum of 450 mm [17.7”] beyond the front of the unit and 200mm [7.8”] beyond
each side of the unit. A Floor Protector of ¼ inch thick is recommended for this installation.
Installation
VENTING REQUIREMENTS
Install vent at clearances specifi ed by the vent manufacturer.
Do not connect the pellet vent to a vent serving any other appliance or stove.
Do not install a fl ue damper in the exhaust venting system of this unit.
The following installation guidelines must be followed to ensure conformity with both the safety listing of this stove and
to local building codes. Do not use makeshift methods or compromise in the installation.
IMPORTANT! This unit is equipped with a negative draft system that pulls air through the burn pot and
pushes the exhaust out of the dwelling. If this unit is connected to a fl ue system other than the way explained
in this manual, it will not function properly.
MAXIMUM VENTING DISTANCE
Installation MUST include at least 3-feet of vertical pipe outside the home. This will create some natural draft to reduce the
possibility of smoke or odor during appliance shutdown and keep exhaust from causing a nuisance or hazard by exposing
people or shrubs to high temperatures. The maximum recommend vertical venting height is 12-feet for 3-inch type “PL”
vent. Total length of horizontal vent MUST NOT exceed 4-feet. This could cause back pressure. Use no more than 180
degrees of elbows (two 90-degree elbows, or two 45-degree and one 90-degree elbow, etc.) to maintain adequate draft.
PELLET VENT TYPE
A UL listed 3-inch or 4-inch type “PL” pellet vent exhaust system must be used for installation and attached to the pipe
connector provided on the back of the stove (use a 3-inch to 4-inch adapter for 4-inch pipe). Connection at back of
stove must be sealed using Hi-Temp RTV. Use 4-inch vent if the vent height is over 12-feet or if the installation is over
2,500 feet above sea level.
We recommend the use of Simpson Dura-Vent® or Metal-Fab® pipe (if you use other pipe, consult your local building
codes and/or building inspectors). Do not use Type-B Gas Vent pipe or galvanized pipe with this unit. The pellet vent
pipe is designed to disassemble for cleaning and should be checked several times during the burning season. Pellet
vent pipe is not furnished with the unit and must be purchased separately.
PELLET VENT INSTALLATION
The installation must include a clean-out tee to enable collection of fl y ash and to permit periodic cleaning of the exhaust
system. 90-degree elbows accumulate fl y ash and soot thereby reducing exhaust fl ow and performance of the stove.
Each elbow or tee reduces draft potential by 30% to 50%.
All joints in the vent system must be fastened by at least 3 screws, and all joints must be sealed with Hi-Temp RTV
silicone sealant to be airtight. The area where the vent pipe penetrates to the exterior of the home must be sealed with
silicone or other means to maintain the vapor barrier between the exterior and the interior of the home.
Vent surfaces can get hot enough to cause burns if touched by children. Noncombustible shielding or guards may be
required.
PELLET VENT TERMINATION
Do not terminate the vent in an enclosed or semi-enclosed area, such as; carport, garage, attic, crawl space, under
a sundeck or porch, narrow walkway, or any other location that can build up a concentration of fumes. Termination in
one of these areas can also lead to unpredictable pressure situations with the appliance, and could result in improper
performance and/or malfunction
The termination must exhaust above the outside air inlet elevation.
The termination must not be located where it will become plugged by snow or other materials.
Do not terminate the venting into an existing steel or masonry chimney.
9
Loading...
+ 19 hidden pages
You need points to download manuals.