OWNER’S MANUAL
MODELS: VG200
SAVE THESE INSTRUCTIONS
THIS MANUAL WILL HELP YOU TO OBTAIN EFFI-
CIENT, DEPENDABLE SERVICE FROM THE HEATER,
CORRECTLY. KEEP IN A SAFE PLACE FOR FUTURE
SAFETY TESTED TO UL 1482 and ULC-S627
WASHINGTON STATE APPROVED
MOBILE HOME APPROVED (U.S. ONLY)
U.S. Environmental Protection Agency
Certied to comply with 2015 particulate emissions
REFERENCE.
standards.
French version is available for download from the U.S. Stove website: http://www.Usstove.com/
Version française est disponible pour téléchargement à partir du site U.S. Stove: http://www.Usstove.com
CAUTION! Please read this entire manual before you install or use your new room heater. Failure
to follow instructions may result in property
damage, bodily injury, or even death.
Improper Installation Could Void
Your Warranty!
227 Industrial Park Road, South Pittsburg, TN 37380
FOR TECHNICAL ASSISTANCE: Phone 1-800-750-2723 www.usstove.com
SAFETY NOTICE: If this heater is not properly installed, a house re may result. For your safety, follow the in­stallation instructions. Never use make-shift compromises during the installation of this heater. Contact local building or fi re offi cials about permits, restrictions and installation
requirements in your area.
U.S. Stove Company
852375 B-1902E
CONGRATULATIONS!
You’ve purchased a heater from North America’s oldest manufacturer of wood burning products.
By heating with wood you’re helping to CONSERVE ENERGY!
Wood is our only Renewable Energy Resource. Please do your part to preserve our wood supply. Plant at least one
tree each year. Future generations will thank you.
The instructions pertaining to the installation of your wood stove comply with UL-1482 and ULC-S627 standards.
This manual describes the installation and operation of the Vogelzang, VG200 wood heater. This heater meets the
2015 U.S. Environmental Protection Agency’s crib wood emission limits for wood heaters sold after May 15, 2015. Un-
der specifi c test conditions this heater has been shown to deliver heat at rates ranging from 11,817 to 31,713 Btu/hr.
Note: The BTU ratings mentioned above are based on the EPA test protocol burning dimensional Douglas Fir lumber.
Our advertised BTU’s are based on the fi rst hour of operation at high burn rate burning cordwood.
Combustible : Model Wood
Colors : Metallic Black
Flue Pipe Diameter : 6” (152.5mm)
Flue Pipe Type: (Standard Single Wall or Double Wall): Black or Blued Steel 2100°F (650°C)
Minimum Chimney Hieght : 12’ (3.7m)
Maximum Log Length : 21” (533.5mm)
Dimensions
1
/
Overall :
20
2
” x 27” x 31
Depth x Width x Height :
3
/
Combustion Chamber :
4
22
x 12” (578mm x 305mm)
Width x Depth :
Volume :
1.86 ft³ (.0527m³)
Cubic Feet:
Door Opening : Width x Height: 16” x 8” (406.5mm x 203mm)
Pyroceramic Glass Door : (Viewing) Width x Height: 13
13
/
16
x 8
3
Weight (lbs): 295 lbs (134kg)
3
/
4
(521mm x 686mm x 806mm)
/
8
(351mm x 213mm)
DESCRIPTION PART #
Outside Air Intake Kit 50FAK
CAUTIONS:
• HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS.
• DO NOT USE CHEMICALS OR FLUIDS TO IGNITE THE FIRE.
• DO NOT LEAVE THE STOVE UNATTENDED WHEN THE DOOR IS SLIGHTLY OPENED.
• DO NOT BURN GARBAGE, FLAMMABLE FLUID SUCH AS GASOLINE, NAPHTHA OR MOTOR OIL.
• DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.
• ALWAYS CLOSE THE DOOR AFTER THE IGNITION.
2
OPTIONAL ACCESSORIES
WARRANTY INFORMATION CARD
Name__________________________________________ Telephone #: (_____)_____________
City____________________________________________ State_______ Zip_________________
Email Address __________________________________________________________________
Model # of Unit________________________________ Serial #___________________________
Fuel Type:
Wood Coal Pellet Gas Other _________________________
Place of Purchase (Retailer)______________________________________________________
City____________________________________________ State_______ Zip_________________
If internet purchase, please list website address___________________________________
Date of Purchase _______________________________________________________________
Reason for Purchase: Alternative Heat Main Heat Source
Decoration Cost Other _________________________
What was the determining factor for purchasing your new USSC appliance?_______
I have read the owner’s manual that accompanies this unit and fully understand the:
Installation

Operation  and Maintenance  of my new USSC appliance.
Print Name Signature Date
Please attach a copy of your purchase receipt.
Warranty not valid without a Proof of Purchase.
Warranty information must be received within 30 days of original purchase.
Detach this page from this manual, fold in half with this page to the inside and tape together. Apply a stamp and mail to the address provided. You may use an envelope if you choose.
You may register online by going to www.usstove.com
All information submitted will be kept strictly con dential. Information provided will not be sold for advertising purposes.
Contact information will be used solely for the purpose of product noti cations.
CUT HERE CUT HERE
Fold Here Fold Here
Fold Here

PLACE STAMP
HERE
United States Stove Company P.O. Box 151 South Pittsburg, TN 37380
CUT HERE CUT HERE
TOOLS AND MATERIALS NEEDED FOR INSTALLATION
You will need a drill with a 1/8” bit to install sheet metal screws into connector pipe. A 5/16” socket/wrench or screw driver to install pedestal trim, and blower assembly described below. A 1/2” socket/wrench to install ue collar. A non-combustible fl oor protector as specifi ed in this manual. All chimney and chimney connector components required for your particular chimney installation. For mobile homes, see page 13.
ASSEMBLY
Flue Collar Assembly:
1. Mount the fl ue collar to the top of the unit as shown using the (3) (3) weld tabs
provided in the parts box.
Firebrick Confi guration:
1. Replace the Firebrick as shown in the illustration below.
5/16-18 x 1-1/2 bolts, (3) washers, and
Side view of fl ue collar
mount to heater top
Brick Confi guration
5/16-18 x 1-1/2 BOLT
HEATER TOP
WELD TAB
5
BLOWER ASSEMBLY INSTRUCTIONS
THE BLOWER ASSEMBLY MUST BE DISCONNECTED FROM THE SOURCE OF ELECTRICAL SUPPLY BEFORE ATTEMPTING THE INSTALLATION.
Step 1.
Fix the assembly to the back of the stove with the four screws provided.
THE BLOWER ASSEMBLY IS INTENDED FOR USE ONLY WITH A STOVE THAT IS MARKED TO INDI­CATE SUCH USE.
DO NOT ROUTE THE SUPPLY CORD NEAR OR ACROSS HOT SURFACES!
6
INSTALLATION
SAFETY NOTICE
• IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLATION INSTRUCTIONS.
• CONSULT YOUR MUNICIPAL BUILDING DEPARTMENT OR FIRE OFFICIALS ABOUT PERMITS, RESTRICTIONS AND INSTALLATIONS REQUIREMENTS IN YOUR AREA.
• USE SMOKE DETECTORS IN THE ROOM WHERE YOUR STOVE IS INSTALLED.
• KEEP FURNITURE AND DRAPES WELL AWAY FROM THE STOVE.
• NEVER USE GASOLINE, GASOLINE-TYPE LANTERN FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, OR SIMILAR LIQUIDS TO START OR “FRESHEN UP” A FIRE IN THIS HEATER. KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE HEATER WHILE IT IS IN USE.
• IN THE EVENT OF A CHIMNEY FIRE, PUSH THE AIR CONTROL FULL CLOSED TO DEPRIVE THE FIRE OF OXYGEN. CALL THE FIRE DEPARTMENT.
• DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.
• A SOURCE OF FRESH AIR INTO THE ROOM OR SPACE HEATED SHALL BE PROVIDED WHEN REQUIRED.
POSITIONING THE STOVE
It is very important to position the wood stove as close as possible to the chimney, and in an area that will favor the most effi cient heat distribution possible throughout the house. The stove must therefore be installed in the room where the most time is spent, and in the most spacious room possible. Recall that wood stoves produce radiating heat, the heat we feel when we are close to a wood stove. A wood stove also functions by convection, that is through the displacement of hot air accelerated upwards and its replacement with cooler air. If necessary, the hot air distribution from the stove may be facilitated by the installation of a blower.
The wood stove must not be hooked up to a hot air distribution system since an excessive accumulation of heat may occur.
A wood stove must never be installed in a hallway or near a staircase, since it may block the way in case of re or fail to respect required clearances.
7
FLOOR PROTECTOR
Your wood stove should be placed on a 1 inch, non-combustible surface with a k factor of 0.84. For multiple layers, add R-values of each layer to determine the overall R-value. The R value for the required board is
1.2. The fl oor protector should be under the stove, twenty-six inches beyond the front and six inches beyond each side of the fuel loading and ash removal opening. If there is a horizontal section of chimney connector, the fl oor protector should go under it and two inches beyond each side
Convert specifi cation to R-value: k-factor is given with a required thickness (T) in inches: R=1/k x T C-factor is given: R=1/C
Example: If the fl oor protector is 4” brick with a C-factor of 1.25 over 1/8” mineral board with a “k” factor of 0.29 the total R-value of the system is: 4” brick C=1.25, R=1/1.25=0.8 1/8” mineral board K=0.29, R=1/0.29 x 0.125=0.431 Total R = Rbrick + Rmineral = 0.8 + 0.431 = 1.231 Total R is greater than 1.2, the system is acceptable.
The fl oor protector should exceed the stove as follows:
Front Sides Rear
25”
(635mm)8”(203mm)6”(152mm)
8