Vogelzang International SHILOH TR002B Owner's Manual

THE SHILOH
HIGH-EFFICIENCY WOODSTOVE
EPA Certified (4.22 grams/hr)
Model TR002B Owners Manual
(Save These Instructions)
Le manuel de langue français est disponible à www.vogelzang.com
French language manual is available at www.vogelzang.com
Report No. 235-S-01c-2
READ ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING
THIS STOVE. FAILURE TO FOLLOW INSTRUC-
TIONS MAY RESULT IN PROPERTY DAMAGE,
BODILY INJURY, OR EVEN DEATH.
REFER TO MARKINGS ON STOVE LABELS FOR
ADDITIONAL INFORMATION.
SAFETY NOTICE: IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE/BUILDING FIRE MAY RESULT. FOR YOUR SAFETY, CONTACT LOCAL OR MUNICIPAL BUILDING OR FIRE OFFICIALS ABOUT PERMITS, RESTRICTIONS, AND INSTALLATION REQUIREMENTS FOR YOUR AREA.
US: UL 1482-2010 & CDN: ULC-S627-00
NOTE: IT IS RECOMMENDED INSTALLATION
BE COMPLETED BY A QUALIFIED HEATING
DO NOT INSTALL IN A MOBILE HOME.
This stove meets test standards:
EQUIPMENT INSTALLER!
Vogelzang International Corporation 400 West 17th Street Holland, Michigan 49423 www.vogelzang.com Phone: 1-616-396-1911 Fax: 1-616-396-1971
TR002B | 20120125.0 www.vogelzang.com SHILOH™ | Page 1
SAFETY INSTRUCTIONS-Read All Instructions Carefully.
1. The installation of this stove must comply with your local building code rulings. Please observe the clear­ances to combustibles (see reference figures Do not place fuel, furniture or any other objects within the clearance area.
2. Verify that the stove is properly assembled and installed before firing the stove for the first time. After reading these instructions, if you have any doubt about your ability to complete your installation properly, you must obtain the services of a professional licensed installer familiar with all aspects of safe and correct installation. DO NOT use temporary or makeshift compromises during installation. There must be NO DEVIATION OR ALTERATION OF ANY KIND from the very spe­cific instructions spelled out in this instruction manual as it pertains to the installation of this woodstove.
NO EXCEPTIONS!
3. DO NOT store wood, kindling, flammable liquids or other combustible materials in the vicinity of the appliance. Refer to certification label on back of unit and reference figures
4. DO NOT INSTALL THIS STOVE IN A MOBILE
HOME, MANUFACTURED HOME, TRAILER OR TENT NO EXCEPTIONS! (HUD Federal Standard: 24 CFR Ch.XX).
5. DO NOT ELEVATE THIS STOVE BY ANY MEANS. (i.e. bricks under pedestal base, cement blocks) Stove base must set directly upon the solid-surface, non-combustible floor as specified in this stove instruction manual.
6. DO NOT MODIFY THIS STOVE IN ANY WAY! must be installed with pedestal stand provided and attached as shown in the instructions
ERATE WITHOUT ASH DRAWER OR ASH CLEAN OUT COVER IN PLACE – NO EXCEPTIONS. As-
semble only with original parts as supplied and shown in this manual. DO NOT OPERATE A STOVE THAT IS MISSING ANY PARTS! If any parts are missing or defective, please notify the dealer or manufacturer immediately. Replace missing, broken or worn parts with factory original or equivalent parts only.
7. CAUTION: DO NOT ALTER COMBUSTION AIR
CONTROL RANGE TO INCREASE FIRING OR FOR ANY REASON. Altering or tampering with air
control beyond normal capacity will create unsafe and hazardous conditions.
8. Always connect this stove to a chimney and vent to the outside. Never vent to a room or inside a build­ing. DO NOT CONNECT THIS UNIT TO A CHIMNEY
FLUE SERVING ANOTHER APPLIANCE.
9. DO NOT CONNECT A WOOD BURNING STOVE TO
10–12
in this manual.
10–12
Stove
. DO NOT OP-
).
AN ALUMINUM TYPE B GAS VENT. This is not safe. Use approved masonry or an Underwriters Labo­ratories Listed UL 103 HT (US)/ULC-S629 (CDN) Residential Type and Building Heating Appliance Chimney. Use a 6˝/152mm diameter chimney, that is high enough to give a good draft. (See specifics in Chimney Connections instructions).
10. Be sure that your chimney is safely constructed and in good repair. Have the chimney inspected by the fire department or a qualified inspector. Your insurance company should be able to recommend a qualified inspector. Chimney connector pipe must be in good condition. Replace if necessary before using stove.
11. Creosote or soot may build up in the chimney con­nector and chimney and cause a house/building fire. Inspect the chimney connector and chimney twice monthly during the heating season and clean if necessary. (see Service Hints).
12. In the event of a chimney fire, turn the air controls to closed positions, leave the building and CALL THE FIRE DEPARTMENT IMMEDIATELY! Have a clearly understood plan on how to handle a chimney fire by contacting your local fire authority for information on proper procedures in the event of a chimney fire. After the fire is out, the chimney must be cleaned and inspected for any stress or cracks before starting another fire. Check the condition of any combustibles surrounding the chimney.
13. Ashes should not be allowed to accumulate above the top of the lower primary air orifice (LPAO, air vent at front of firebox, just inside of door).
14. DISPOSAL OF ASHES Ashes should be placed in a steel container with a tight fitting lid and moved outdoors immediately. The closed container of ashes should be placed on a noncombustible floor or on the ground, well away from all combustible materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have completely cooled. Other waste shall not be placed in this container.
15. To prevent injury, do not allow anyone to use this stove who is unfamiliar with the correct operation of the stove.
16. Do not operate stove while under the influence of drugs or alcohol.
17. DO NOT ELEVATE THE FIRE. Build fire directly on the bottom of the firebox. This stove has not been tested with the use of grates, andirons or other means of elevating the fire and must not be used.
18. The special paints used on your stove may give off some smoke and an odor while they are cur-
Page 2 | SHILOH™ Vogelzang International Corp. TR002B | 20120125.0
SAFETY INSTRUCTIONS continued…
ing during the first 12 to 15 fires. Additional smoke and odor may be emitted from the light oils used in construction of the fire box. This should disap­pear after a short period of time and not occur again. Persons with lung conditions or owners of susceptible domestic pets (such as birds) should take prudent precautions. Open windows and doors as needed to clear smoke and/or odor. Paint discolor­ation will occur if the stove is over fired.
19. This stove has a painted surface which is durable but it will not stand rough handling or abuse. Use care when installing your stove. firebox walls may become distorted. A slight distor­tion will not affect stove operation.
20. CLEAN STOVE FREQUENTLY as soot, creosote and ash may accumulate. Clean exterior with soap and warm water when stove is not hot. Do not use any acids or scouring soap, as these solvents wear and dull the finish.
21. ALERT ALL PERSONS TO THE HAZARDS OF HIGH SURFACE TEMPERATURES while stove is in operation – especially young children. Keep away from a hot stove to avoid burns or clothing ignition.
22. NEVER LEAVE SMALL CHILDREN UNSUPER-
VISED WHEN THEY ARE IN THE SAME ROOM AS THE STOVE. If small children will be in the same
room as the stove during operation, provide a sturdy barrier to keep them at a safe distance from the stove.
23. Keep stove area clear and free from all combustible materials, gasoline, engine oil, naphtha and other flammable vapors and liquids.
24. WHILE TENDING THE FIRE ALWAYS WEAR PRO- TECTIVE CLOTHING, fire retardant hearth gloves and eye protection, to prevent burns.
25. NEVER OPERATE THIS STOVE WITHOUT ASH
DRAWER, ASH CLEAN OUT OR WITH THE DOOR OPEN except when re-fueling. Such actions can
result in very dangerous operating conditions.
26. DO NOT OVER FIRE THE STOVE. Over firing will occur if combustion air is uncontrolled as when feed door is left open during operation. Such actions can result in very dangerous operating conditions. While in operation, keep the feed door closed and secured at all times except while tending the fire
27. When adding fuel be careful not to smother the fire. Do not build fires against glass and do not load fuel to a height or in such a manner that it creates a hazard when opening the door.
28. NEVER LEAVE THE STOVE UNATTENDED with door open. Always close the door after ignition.
29. DO NOT CONNECT TO OR USE IN CONJUNC-
After a period of use the
TION WITH ANY AIR DISTRIBUTION DUCT WORK UNLESS SPECIFICALLY APPROVED FOR SUCH INSTALLATIONS.
30. A WOOD-BURNING STOVE MUST NEVER BE INSTALLED IN A HALLWAY OR NEAR A STAIR­CASE, as it may block egress in the event of a fire.
31. DO NOT INSTALL IN A SLEEPING ROOM.
DO NOT INSTALL IN AN ALCOVE OR INSIDE A
FIREPLACE.
32. Install at least one smoke detector on each floor of your home. Detectors should be located away from the heating appliance to avoid false alarms. Detectors should be located close to sleeping areas. Follow the smoke detectors manufacturer’s placement and installation instructions. Maintain smoke detector per manufacturer’s instructions.
33. CARBON MONOXIDE (CO) HAZARD. A buildup of CO fumes is toxic and can be fatal. Carbon Monoxide is a colorless, odorless gas produced during combus­tion of wood, coal, oil, gas and by other fuel burning appliances. It is important to have a proper draft and adequate replacement air ventilation so fumes are drawn out the chimney. Installed as instructed this stove is designed to be as safe as possible yet it is recommended to install a CO detector. Follow the manufacturer’s recommendations for proper instal­lation and use. It is recommended to be placed at table-top level (not near the ceiling) to avoid false alarms. Realize that devices other than a stove (i.e. motor exhaust) can trigger CO alarms.
If alarm sounds:
• RecognizethesymptomsofCOpoisoning(head- aches, nausea & drowsiness).
 • Increaseventilation(openwindows&doors).  • Makesurestovedoorsand/orlidsareclosedand
secured.
 • Checkstoveforsmokingorpufng(openairow
controls).
 • Checkchimney&connectorpipeforleaks,block-
age or down-draft conditions.
• CheckCOdeviceforfalsealarm.
34.
All power cords and electrical appliances and/or assemblies must be kept outside area shown in this manual for combustible materials.
35. Consult your municipal building department or fire officials about restrictions, permits and installation requirements for your area.
36. For further information on using your stove safely, obtain a copy of the National Fire Protection Association (NFPA) publication, “Using Coal and Wood Stoves Safely” NFPA No. HS-10-1978. Write NFPA, Batterymarch Park, Quincy, MA 02269.
of the clearance
TR002B | 20120125.0 www.vogelzang.com SHILOH™ | Page 3
TABLE OF CONTENTS
SAFETY PRECAUTIONS ............................................................................... 2 – 3
TOOLS AND MATERIALS REQUIRED FOR INSTALLATION ............................ 5
ASSEMBLY INSTRUCTIONS ........................................................................ 5 – 6
LOCATING THE STOVE ...................................................................................... 7
Minimum Clearances ......................................................................... 7 – 8
INSTALLATION ............................................................................................ 9 – 14
FIREBRICK ASSEMBLY ..................................................................................... 9
CONNECTOR PIPE INSTALLATION ................................................................. 10
CHIMNEY SIZING ............................................................................................... 11
CHIMNEY CONNECTIONS ......................................................................... 11 –14
CHIMNEY CONNECTION SYSTEMS & CLEARANCES ................................... 15
OPERATING INSTRUCTIONS
House Fire Hazards, Operating Precautions, Warnings ...................... 16
Wood Types/Sizes .................................................................................... 16
Optimal Fuel Consumption .................................................................... 16
Starting a Fire .......................................................................................... 17
Adding Fuel ............................................................................................. 17
SERVICE HINTS
Creosote Formation, Prevention, Removal .......................................... 18
Chimney Draft ......................................................................................... 19
Glass Care & Replacement ................................................................... 20
Glass Gasket Replacement ................................................................... 20
Door Gasket Replacement .................................................................... 21
OPTIONAL F-6 BLOWER MAINTENANCE & WIRING DIAGRAM ................... 21
PARTS – SHILOH™ .......................................................................................... 22
PARTS – GLASS DOOR .................................................................................... 23
PARTS – FIRE BRICK ....................................................................................... 23
FLOOR PROTECTOR CALCULATIONS ........................................................... 24
CHIMNEY & STOVE MAINTENACE LOG ......................................................... 25
NOTE: A LICENSED PROFESSIONAL HEAT­ING AND COOLING CONTRACTOR SHOULD BE CONSULTED IF YOU HAVE QUESTIONS REGARDING THE INSTALLATION OF THIS SOLID FUEL BURNING APPLIANCE.
Page 4 | SHILOH™ Vogelzang International Corp. TR002B | 20120125.0
ASSEMBLY INSTRUCTIONS
NOTICE: Vogelzang International Corp. grants no warranty, stated or implied, for the installation or maintenance
of your wood stove and assumes no responsibility of any incidental or consequential damages.
TOOLS AND MATERIALS REQUIRED
FOR INSTALLATION
TOOLS
• Pencil
• 6 foot Folding Rule or Tape Measure
• Tin Snips
• Drill: Hand or Electric
• 1/8˝ dia. Drill Bit (for sheet metal screws)
• Screwdrivers (blade and Phillips type)
• 10mm Nut Driver or Ratchet with 10mm Socket
• Safety Glasses
• Gloves
• 11/16 Socket or Wrench
MATERIALS
(NOTE: The following items are NOT included with your stove)
Flooring Protection: as specified (see page 7)
Chimney Connection: 6˝ dia. minimum 24 MSG black or 26 MSG
blue steel straight stove pipe or elbow(s) as required.
1/2˝ Sheet Metal Screws
Chimney: Existing 6˝ Code-approved Lined Masonry Chimney
or 6˝ Inside Dia. UL 103 HT (US)/ULC-S629 (CDN) listed
manufactured chimney.
Furnace Cement (manufacturer recommends Rutland Code 78
or equivalent)
CAUTION: STOVE IS HEAVY. MAKE SURE YOU HAVE ADEQUATE HELP AND USE PROPER LIFTING TECHNIQUES WHENEVER MOVING STOVE.
1. Uncrate the stove and remove all cardboard and styrofoam packing materials and protective poly bag. Remove pedestal base, sides, front, top, ash­drawer and ash drawer support from the carton. (Save packing materials for further assembly.)
NOTICE: DO NOT remove ceramic blanket
material from inside stove pipe opening (Fig. 1). This blanket provides an air seal on the side walls of the stove to direct combustion gasses over the secondary combustion tubes before exiting via the
chimney. DO NOT REMOVE the ceramic blanket or your stove will not operate properly.
Figure 2 – Pedestal Assembly Hardware: sheet metal screws, 5/16˝ machine screw, lock washer & hex nuts
Figure 3 – Assemble sides to base
2. Remove parts and hardware pack located inside firebox.
3. Align the hole pattern of one of the pedestal sides to the holes in the base and secure with four (4) machine screws, lock washers and hex nuts. As­semble the opposite side to the base. (Note: Sides are interchangeable)
Figure 4 –
Attach Pedestal
Front Frame to Sides.
(Note– front goes OVER
the side panels.)
DO NOT
REMOVE!
Figure 1 – DO NOT remove ceramic blanket from
inside stove pipe opening. This is NOT packing
material but an integral component of the stove
combustion system.
TR002B | 20120125.0 www.vogelzang.com SHILOH™ | Page 5
4. Attach the pedestal front frame to the sides. The pedestal front should go over (not inside of) the side panels. Use three (3) self-tapping screws (provided in the hardware pack) on each side to attach both pedestal sides to the pedestal front (figure 4).
5. Position ash drawer support into assembled ped­estal (Figure 5) and secure from rear with two (2) machine screws, lockwashers and hex nuts. Tighten all pedestal hardware.
6. Position the pedestal top with the large vent hole positioned toward the front and attach with six (6)
continued on next page
ASSEMBLY INSTRUCTIONS . . . continued
11. For Optional Blower Assembly, note the position
of the blower opening in the rear of the stove.
12. Place blower gasket onto blower assembly (Figure
8) so as not to obstruct the air flow from the fan.
13. Mount the blower assembly to the back of the stove (Figure 9) aligning the fan opening to the opening in the back of the stove. Secure with four sheet metal screws.
Figure 5 – Insert Ash Drawer Support.
Figure 6 – Attach Pedestal Top.
(Note– Position vent orifice towards front.)
machine screws, lock washers and hex nuts. (See Figure 6)
7. Place flattened carton/styrofoam packing material on floor and carefully tip the stove body onto it’s back.
8. Align four (4) corner mounting studs with holes in pedestal top (Figure 7). Secure with four (4) hex nuts.
Figure 7 – Attach Pedestal to Stove Body
9. Tip the stove assembly upright.
10. Set the ash drawer inside the open box formed by the pedestal front and sides.
Figure 8 – Blower Option
14. Route the power cord away from stove. Do not allow the power cord to touch any hot surfaces. Keep power cord at least 12˝ from stove surfaces.
15. Once stove is positioned, plug power cord into a grounded 120v outlet.
Figure 9 – Attach Optional Blower to Stove Body
16. After assembly, check to make sure fire brick are properly positioned and ash cleanout cover is in place.
Page 6 | SHILOH™ Vogelzang International Corp. TR002B | 20120125.0
LOCATING STOVE
FLOOR
PROTECTOR
DASHED LINES SHOW HORIZONTAL CHIMNEY CONNECTOR AND ADDITIONAL FLOOR PROTECTOR REQUIRED BENEATH AND EXTENDING 2"/5cm BEYOND EACH SID
E
COMBUSTIBLE CONSTRUCTION IN ACCORDANCE WITH US NFPA 211
BACKWALL
SIDEWALL
8"/20.3cm
minimum
18"/46.8cm
44"/112cm
18"/46.8cm min.
8"/20.3cm min.
23"/54.5cm
15"/38.1cm
min.
12"/30.5cm
minimum
TOP VIEW | CANADIAN CLEARANCES
39"/
100cm
TR001B
Minimum
Clearances &
Minimum
Floor Protector
Dimensions
for Canadian
Installation
According to
ULC 5627
1. The stove must be placed on solid concrete, solid masonry, or when installed on a combustible floor, on an UL 1618 Type 2 listed floor protector, such as Hy-C or Imperial Model UL 3648BK (US) or UL4048BK (CAN) or equivalent. Floor protec- tor must be 1/2˝/13mm minimum thickness (“k” value = 0.84, R value = 0.59, see page 24 for calculation formulas) non-combustible material or equivalent. US Requirements: The floor protector must extend at least 16˝/41cm beyond the front of the access door, 6˝/15.2cm to the sides and 12˝/30.5cm beyond the rear. Floor protection mate­rial must extend under and 2˝/51mm beyond either side of the stove pipe connector if it is elbowed towards a wall. (See figures 10–12 and consult lo­cal building codes and fire protection ordinances.) Canadian Requirements: The base must extend at least 18˝/46.8cm beyond the front of the access door, 8˝/20.3cm to the sides, 8˝/20.3cm behind the stove and must extend under and 2˝/51mm beyond either side of the stove pipe if it is elbowed towards a wall. (See figures 10–12 and consult local building codes and fire protection ordinances).
CAUTION: (FIRE HAZARD) CARPETING AND OTHER COMBUSTIBLE MATERIAL SHALL NOT COVER THE FLOOR PROTECTOR. THESE MATE­RIALS MUST REMAIN OUTSIDE OF COMBUS­TIBLE CLEARANCES, SEE FIGURES 10 – 12.
2. The room in which he stove is installed must have a minimum floor to ceiling height of 8 ft./2.4 m & a minimum stove top to ceiling height of 55˝/140 cm.
3. The stove must have its own flue. Do not con­nect this unit to a chimney flue serving other appliances.
4. After observing the clearances to combus­tible materials (figures 10–12), locate your floor protector accordingly (figure 10) and care-
fully place the stove in your selected location. Install stove pipe, elbows, and thimble as required, utilizing either a recently cleaned and inspected 6˝/152mm masonry chimney or a 6˝/152mm i.d. UL 103 HT (US)/ULC-S629 (CDN) listed manufactured chimney.
5. Use round 6˝/152mm dia., minimum 24 MSG black or 26 MSG blue steel stove pipe to connect the stove to the chimney. DO NOT USE GALVANIZED DUCT PIPE AS A CONNECTOR. Secure pipe sections with three (3) sheet metal screws no more than a maximum of 3˝/76mm apart in each stove pipe and/or elbow joint to firmly hold the pipe sec­tions together. DO NOT CONNECT THIS STOVE TO ANY AIR DISTRIBUTION OR DUCT SYSTEM.
6. Recheck clearances from the stove, connector stove pipe, and corner clearances using the illustrations in figures 10–12 and your local building codes or fire protection ordinances.
NOTICE: Any wall containing combustible
materials such as wooden studs, drywall and
faced with brick or stone MUST be considered a combustible surface.
7. DO NOT install this stove in a mobile home, manufactured home, trailer or tent – NO EXCEPTIONS! (HUD Federal Standard: 24 CFR Ch.xx)
8. The clearances provided are minimum dimensions set by UL 1482-2010 & ULC-S627-00, tested and applied by OMNI Test Laboratories, Inc., the manu­facturer’s testing laboratory.
Clearances listed and shown MUST be adhered to
for safe operation of this appliance. CLEARANCES
MAY NOT BE REDUCED BY ANY MEANS IN USA OR CANADA.
continued on next page
COMBUSTIBLE CONSTRUCTION IN ACCORDANCE WITH NFPA 211
12"/30.5cm
minimum
SIDEWALL
15"/38.1cm
min.
TR002B | 20120125.0 www.vogelzang.com SHILOH™ | Page 7
TOP VIEW | USA CLEARANCES
DASHED LINES SHOW HORIZONTAL CHIMNEY CONNECTOR
BACKWALL
AND ADDITIONAL FLOOR PROTECTOR REQUIRED BENEATH
35"/ 89cm
TR001B
FLOOR
PROTECTOR
23"/54.5cm
12"/30.5cm
minimum
18"/45.7cm
6"/15.2cm min.
Fig. 10 – Top View Minimum Clearance Dimensions
AND EXTENDING 2"/5cm BEYOND EACH SIDE
46"/117cm
16"/40.6cm min.
Minimum
Clearances &
Minimum
Floor Protector
Dimensions
for United States
Installation According to UL 1482-2006
from Combustible Surfaces
LOCATING STOVE
12"/30.5cm
12"/
30.5cm
CORNER CLEARANCES
Failure to follow these minimum clearance require-
ments may result in an unsafe installation and could cause a fire.
Installation of this stove must comply with the latest
edition of NFPA 211 for reduced clearances and/ or your local building code rulings. Use whichever minimum dimensions are the LARGEST.
9. NEVER OPERATE THIS STOVE WITHOUT THE
ASH CLEANOUT COVER IN PLACE OR WITH THE ASH DRAWER REMOVED – very dangerous
operating conditions could result.
10. This stove meets U.S. Test Standard: UL 1482-2010 & Canadian Standard: ULC-S627-00.
11. Always locate stove to provide a source of fresh air into the room where the unit is installed. Failure to do so may result in air starvation of other fuel burning appliances and the possible develop­ment of hazardous conditions.
CAUTION: KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIALS AWAY FROM THE STOVE AND OUTSIDE MINIMUM CLEARANCES.
CAUTION: REPLACE FIREBRICKS BEFORE FIRING WOODSTOVE. POSITION FIREBRICKS SO NO GAPS REMAIN BETWEEN BRICKS.
Fig. 11 – Top View
Minimum Corner Clearances
from Combustible Surfaces
Minimum Clearance Dimensions
from Combustible Surfaces
Page 8 | SHILOH™ Vogelzang International Corp. TR002B | 20120125.0
Fig. 12d – Side ViewFig. 12c – Front ViewFig. 12b – Side ViewFig. 12a – Front View
Minimum Clearance Dimensions
from Combustible Surfaces