Installationsanleitung, Guía de Instalacíon, Guida de Installazione, Guide d’Installation, Installatie gids
www.vogels.com
Page 2
PFW 6880
Installation Guide
Installationsanleitung, Guía de Instalacíon, Guida de Installazione, Guide d’Installation, Installatie gids
Included components
Maximum Flat Panel Weight:
100 lb. / 45.35 kg.
5/16” Flat Washers
(Qty 4)
5/16” x 3” Lag Bolts
(Qty 4)
M4 x 12mm (Qty 4)
M4 x 16mm (Qty 4)
M4 x 25mm (Qty 4)
M5 x 12mm (Qty 4)
M5 x 16mm (Qty 4)
M5 x 25mm (Qty 4)
Universal Spacers
(Qty 8)
5/16” Concrete Wedge Anchors
(Qty 4)
M6 x 12mm (Qty 4)
M6 x 16mm (Qty 4)
M6 x 25mm (Qty 4)
M5 Allen Driver
(Qty 1)
Thread Depth Indicator
(Qty 1)
M8 x 12mm (Qty 4)
M8 x 16mm (Qty 4)
M8 x 25mm (Qty 4)
Universal Washers
(Qty 4)
Required for installation
Electronic Stud Finder1/4” Drill Bit
Level
Page 1
PencilProtective Eyewear
1/2” Socket
Phillips Head Screwdriver
www.vogels.com
Portable Drill
Socket Wrench
Page 3
PFW 6880
Installation Guide
Installationsanleitung, Guía de Instalacíon, Guida de Installazione, Guide d’Installation, Installatie gids
You must secure the mount to two (2) wall studs with four (4)
lag bolts (2 lag bolts for each stud found).
1) Use a stud nder to determine the exact center of wall studs in
the vicinity of the mount.
2) Use a pencil to mark the exact center of each of the wall studs.
1
X
X
Two people are recommended for this step; one person to level the
mount and another person to mark the wall stud location.
1) Place the mount against the wall in the desired viewing location.
2) Adjust the mount to align the mount slots in the mount with the
center of the wall studs.
3) Level the mount.
4) Use a pencil to mark the upper right mounting location along the
center of the wall stud.
2
www.vogels.com
Page 2
Page 4
PFW 6880
Installation Guide
Installationsanleitung, Guía de Instalacíon, Guida de Installazione, Guide d’Installation, Installatie gids
3
Drill a “pilot hole” in the center of the upper right mark using a 1/4” drill bit
and power drill.
(Only use a 1/4” drill bit when drilling pilot holes.)
X
X
4
1) Place the mount against the wall and align it with the pilot hole.
2) Insert one (1) 5/16” x 3˝ lag bolt and one (1) 5/16”washer into the
upper right pilot hole.
3) Use a socket wrench and a 1/2” socket to tighten the lag bolt.
Do not overtighten the lag bolt.
Page 3
www.vogels.com
Page 5
Installationsanleitung, Guía de Instalacíon, Guida de Installazione, Guide d’Installation, Installatie gids
1) Level the mount.
2) Use a pencil to mark the remaining four (4) mounting locations
along the center of each wall stud.
PFW 6880
Installation Guide
5
Two people are recommended for this step; one person to level
the mount and another person to drill the pilot holes.
Drill a “pilot hole” in the center of each of the marks with a power drill
and a 1/4″ drill bit.
Only use 1/4″ drill bit when drilling the pilot holes.
6
www.vogels.com
Page 4
Page 6
PFW 6880
Installation Guide
Installationsanleitung, Guía de Instalacíon, Guida de Installazione, Guide d’Installation, Installatie gids
1) Insert one (1) 5/16” x 3″ lag bolt and one (1) 5/16” washer into each
7
pilot hole
2) Tighten all lag bolts using a socket wrench and 1/2” socket.
Do not overtighten the lag bolts when attaching the mount to
the wall. Improper installation may result in personal injury or
property damage.
Installing OPTIONAL Model Specic Spacers
PFW 6880 dedicated at-panel spacers are engineered with the knowledge
that aligning each at-panel on a large wall is time consuming and costly.
These model-specic spacers are available for most at-panels, which
signicantly reduces the installation time. (Call Customer Service to inquire
about model specic spacers.)
Page 5
www.vogels.com
Page 7
Installationsanleitung, Guía de Instalacíon, Guida de Installazione, Guide d’Installation, Installatie gids
This spacer is shown for illustration purposes only. Your spacer may
look different depending on the display model you are installing.
1) Once your PFW 6880 is mounted in the desired location and
is level, align your spacer to the top left or right (depending on
your install direction) corner register tabs of your mount.
You may use commercially available hardware to secure the
spacer to the wall during installation (depending on the wall material).
You may utilize the same spacer for multiple PFW 6880 installations.
PFW 6880
Installation Guide
1
Multiple PFW 6880 mounts can be installed using model specic spacers.
Simply repeat step one when installing each of the surrounding PFW 6880
mounts. Use one spacer for each 2x2 installation by mounting it to the wall,
or utilize the same spacer as many times needed to complete an unlimited
PFW 6880 large matrix video wall.
1. Make sure the spacer is plumb and level and mark each corner where
the PFW 6880 will be mounted (or secure to the wall). It is best to
start from the bottom corner and work your way up.
2. Install the second mount working in a horizontal direction.
3. Ensure that the mount remains plumb and level.
4. Repeat this step for each mount horizontally
5. To install multiple rows, place spacer between previously installed
PFW 6880’s on the bottom row. Make sure the spacer is plumb and
level, mark the corners (or secure to the wall) to be sure of where the
PFW 6880 should be and secure your mount to the wall.
Start
www.vogels.com
Page 6
Page 8
PFW 6880
Installation Guide
Installationsanleitung, Guía de Instalacíon, Guida de Installazione, Guide d’Installation, Installatie gids
Selecting the Mounting Hardware
1) Insert a small straw or toothpick into the threaded
inserts found on the back of the at-panel.
2) Use a pencil to mark the depth of the threaded
insert on the small straw or toothpick.
3) Mark the straw or toothpick 1/8” above the depth of
the threaded insert, as shown in Figure 1.
4) Insert the small straw or toothpick into the remaining
threaded inserts to compare and verify their depth
using the straw or toothpick’s 1/8” allowance mark.
5) Locate the correct diameter screw for the threaded
insert.
If the screw you selected is longer than the 1/8”
allowance mark on the small straw or toothpick,
as shown in Figure 2 and Figure 3, do not use
this screw. The screw length must not bypass the
Marking the 1/8”
Allowance
mark.
6) Test each size of the screws provided.
Small Straw
or Toothpick
Small Straw or Toothpick
Depth Plus 1/8” Allowance
Mark
Small Straw
or Toothpick
The correct screws should thread easily into the
mounting point and not pull out when tension is
applied.
Go to “Griplate™ Washer Installation” on page 10
Depth Plus 1/8” Allowance
Mark
Page 7
www.vogels.com
Page 9
Installationsanleitung, Guía de Instalacíon, Guida de Installazione, Guide d’Installation, Installatie gids
Universal Washer Installation
M8
M5, M6
M4
PFW 6880
Installation Guide
Universal Washers are designed to accommodate the
various M4, M5, M6 and M8 hole sizes required by at-
panels.
Do not place excessive pressure on the back of the
at-panel, as this may damage your at-panel.
The Universal Washer must be installed between
the head of the mounting screw and the mounting
bracket as shown.
Does your at-panel have:
● Recessed mount points?
● Uneven mount points?
● A curved back?
● Any obstruction near the mount point?
Universal Spacer Installation
Mounting Screw
Universal Washer
Mounting Bracket
Flat Panel
Universal Spacer
Mount Point
Universal Spacers allow you to attach the mounting
bracket to at-panels which have recessed or uneven
mount points. Each Universal Spacer adds 1/4” to
the distance between the mounting bracket and your
at-panel.
The Universal Spacers must be stacked and
oriented as shown.
The Universal Spacers must only be installed
between the mounting bracket and your at-panel.
Proceed to the “Attaching the Mounting Bracket to
the Flat-Panel” section.
www.vogels.com
Page 8
Page 10
PFW 6880
Installation Guide
Installationsanleitung, Guía de Instalacíon, Guida de Installazione, Guide d’Installation, Installatie gids
Attaching the Mounting Brackets to the Flat-Panel
This section presumes that you have read and understood thes
"Selecting the Proper Mounting Hardware" section.
1) Secure each mounting bracket to your at-panel by inserting
a minimum of two (2) screws per bracket.
Do not overtighten the mounting hardware.
Make sure the directional arrows on the mounting
brackets are facing up.
NOTE: For smaller vesa bolt patterns, reverse the
mounting brackets.
2) Before tightening the screws, push the bracket up to
remove slack from the bracket, then tightened the
screw.
Attaching the Flat-Panel to the Mount
Mounting bracket adjustments are factory pre-set (see Note).
This section requires two people.
Do not release your at-panel until you are certain that top and
bottom hooks of both mounting brackets are securely seated
on the upper and lower mounting rails of the wall panel.
1) Raise the at-panel past the top and bottom mounting rails on the
wall panel.
2) Slide the at-panel down slowly, keeping it close to the wall.
3) Engage the top and bottom mounting brackets to the rails of the
mount.
Note: These registers must
align prior to installation.
They are factory set.
Check to determine proper
alignment
Page 9
www.vogels.com
Page 11
Installationsanleitung, Guía de Instalacíon, Guida de Installazione, Guide d’Installation, Installatie gids
Post-Installation Adjustments
The PFW 6880 has a set of post-installation adjustments on each
mounting bracket (Figure 1).
Use the M5 Allen Driver (supplied) to ne-tune adjust.
PFW 6880
Installation Guide
See Note
Make sure the the locking safety screws are loosened before making
adjustments.
Note: Screws have a limited travel adjustment.
Do not overtighten or over adjust the screw to avoid damage to
threaded holes.
Locking Safety Screw Installation
The locking safety screws keep the at-panel from being
accidently dislodged from the PFW 6880.
1) Locate the pre-installed security locking safety screw at the bottom
of each of the mounting brackets.
2) Use the M5 Allen driver (supplied) to tighten the locking safety
screw.
Figure 1
See Note
See Note
Note: Tighten screw to surface, then tighten 1/4” turn
Do not overtighten the locking safety screws.
www.vogels.com
Pre-installed
Locking Safety Screw
(1 per Bracket)
Page 10
Page 12
PFW 6880
Installation Guide
Installationsanleitung, Guía de Instalacíon, Guida de Installazione, Guide d’Installation, Installatie gids
Move Inward
Left Control
Move Outward
Left Control
Tilt Left
Right Control
Right Control
Left Control
Tilt Right
Left Control
Page 11
Right Control
Right Control
www.vogels.com
Page 13
Positive / Negative Tilt
C
L
C
L
PFW 6880
Installation Guide
Installationsanleitung, Guía de Instalacíon, Guida de Installazione, Guide d’Installation, Installatie gids
Negative Tilt
control
Post Leveling (Up)
Left Control
Post Leveling (Down)
Left Control
Positive Tilt
Control
Right Control
Right Control
Push evenly on location as shown
www.vogels.com
Page 12
Page 14
PFW 6880
Installation Guide
Installationsanleitung, Guía de Instalacíon, Guida de Installazione, Guide d’Installation, Installatie gids
Use the GAPit GO/No Go Gauge (supplied with model specific spacer) as a final step in
the process to inspect and adjust the gap to prevent costly replacement and extend the
lifespan of the displays.
Damage happens when weight is transferred to the ultra-thin bezels of
video wall installations, if the recommended gap specications of .050” is
not maintained vertically and horizontally. This results in image distortion,
and costly repairs and replacement.
Page 13
1. Swipe GAPit along vertical gap
2. Inspect for .050” gap & adjust if
needed
3. Swipe GAPit along horizontal gap
4. Inspect for .050” gap & adjust if
needed
www.vogels.com
Page 15
Installationsanleitung, Guía de Instalacíon, Guida de Installazione, Guide d’Installation, Installatie gids
Maintenance
1) Push evenly in the front of the PFW 6880 to release the single latch
spring lock(Figure 1).
Servicing
1) Slowly pull the front of the PFW 6880 to extend the scissor arms
(Figure 2).
2) Loosen the locking safety screws on both mounting brackets.
3) Tilt up the bottom of the at-panel, then set their kickstands
against the bottom tubing of the mount (Figures 2 & 3).
You can now reach behind the at-panel for maintenance and
servicing or replacement. After servicing, make sure the spring
lock is locked again in the mount’s closed position.
PFW 6880
Installation Guide
Single Latch
Spring Lock
Figure 1
Page 14
www.vogels.com
Figure 2
Figure 3
95V0-000-023-0X Rev.0
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.