Parts List.......................................................................................................................................................................... 3
Mount Orientation. .................................................................................................................................................... 6
Nose Piece Orientation. ............................................................................................................................................ 7
Attaching the Flat Panel to the Swingout Arm. .............................................................................................................. 15
Fine Tuning & Adjustments. ........................................................................................................................................... 16
SUPPORTING AT LEAST FOUR TIMES THE WEIGHT OF
THE FLAT PANEL. IF NOT, THE WALL STRUCTURE MUST
BE REINFORCED.
Warning Statements
PRIOR TO THE INSTALLATION OF THIS PRODUCT, THE INSTALLATION INSTRUCTIONS MUST BE READ AND
COMPLETELY UNDERSTOOD. KEEP THESE INSTALLATION INSTRUCTIONS IN AN EASILY ACCESSIBLE LOCATION
FOR FUTURE REFERENCE.
PROPER INSTALLATION PROCEDURE BY A QUALIFIED SERVICE TECHNICIAN MUST BE FOLLOWED, AS OUTLINED
IN THESE INSTALLATION INSTRUCTIONS. FAILURE TO DO SO COULD RESULT IN PROPERTY DAMAGE, SERIOUS
PERSONAL INJURY, OR EVEN DEATH.
SAFETY MEASURES MUST BE PRACTICED AT ALL TIMES DURING THE ASSEMBLY OF THIS PRODUCT. USE
PROPER SAFETY EQUIPMENT AND TOOLS FOR THE ASSEMBLY PROCEDURE TO PREVENT PERSONAL INJURY.
VOGEL’S DOES NOT WARRANT AGAINST DAMAGE CAUSED BY THE USE OF ANY VOGEL’S PRODUCT FOR
PURPOSES OTHER THAN THOSE FOR WHICH IT WAS DESIGNED OR DAMAGE CAUSED BY UNAUTHORIZED
ATTACHMENTS OR MODIFICATIONS, AND IS NOT RESPONSIBLE FOR ANY DAMAGES, CLAIMS, DEMANDS, SUITS,
ACTIONS OR CAUSES OF ACTION OF WHATEVER KIND RESULTING FROM, ARISING OUT OF OR IN ANY MANNER
RELATING TO ANY SUCH USE, ATTACHMENTS OR MODIFICATIONS.
At least two qualied people should perform the assembly procedure. Personal injury and/or property damage can result
from dropping or mishandling the at panel.
If mounting to wall studs, make sure that the mounting screws are anchored into the center of the wall studs. Use of an
edge-to-edge stud nder is recommended.
It is recommended that a minimum of 1/2” drywall be used when mounting to wooden studs.
Be aware of the mounting environment. If drilling and/or cutting into the mounting surface, always make sure that there
are no electrical wires in wall. Cutting or drilling into an electrical line may cause serious personal injury.
Make sure there are no water or natural gas lines inside the wall where the mount is to be located. Cutting or drilling into a
water or gas line may cause severe property damage or personal injury.
This product is intended for indoor use only. Use of this product outdoors could lead to product failure and/or serious
personal injury.
Do not install near sources of high heat. Do not install on a structure that is prone to vibration, movement or chance of
impact.
Contact Vogel’s with any questions:
+31 40 264 7400
Page 2 Visit the Vogel’s website at http://www.vogels.comInstallation Instructions
PFW6852
Installation Tools
The following tools may be required, dependent upon your particular installation. These tools are not provided by
Vogel’s, but you can purchase them at your local hardware store.
2
1
Tape Measure
Electronic Stud Finder
Hand Held Drill
¼˝ Wood
Drill Bit
3/8” Concrete
Drill Bit
Pencil
Protective Eyewear
Hammer
Screwdriver
Socket Wrench
½″ Socket
Parts List
Your Vogel’s product is shipped with all proper installation hardware and components. Make sure that none of these
parts are missing and/or damaged before beginning installation. If there are parts missing and/or damaged, please stop
the installation and contact Vogel’s +31 40 264 7400.
PFW6852 Universal Swingout Arm Hardware
Adapter Plates and
Hardware
Adapter Plates
(Qty 4)
Phillips Tip
Universal Brackets
(Qty 2)
PFW6852 Swingout Arm
(Qty 1)
Universal Bracket Bar
(Qty 1)
M8 Nylon Nuts
(Qty 4)
5
/16″ Flat Washers
(Qty 6)
Griplate™
(Qty 8)
Thread Depth Indicator
(Qty 1)
5
/16″ Flat Washers
(Qty 4)
Tools (supplied)
Level
(Qty 1)
5
5
/32″ Allen Wrench
(Qty 1)
14mm Socket
(Qty 1)
/16″ x 3″ Lag Bolts (Qty 6)
Wood Stud Installation Only
M10 x 30mm Screws
(Qty 4)
Installation Instructions Visit the Vogel’s website at http://www.vogels.comPage 3
Parts List (cont’d)
PFW6852
Hardware
M4 x 16mm Screw
(Qty 8)
M4 x 25mm Screw
(Qty 8)
M5 x 12mm Screw
(Qty 8)
M5 x 16mm Screw
(Qty 8)
M5 x 20mm Screw
(Qty 8)
M6 x 16mm Screw
(Qty 8)
M6 x 20mm Screw
(Qty 8)
M6 x 30mm Screw
(Qty 8)
M6 x 45mm Screw
(Qty 8)
M8 x 20mm Screw
(Qty 8)
M5 x 25mm Screw
(Qty 8)
M5 x 50mm Screw
(Qty 8)
¼″ Nylon Spacer (Large) (Qty 8)
½″ Nylon Spacer (Large) (Qty 12)
1″ Nylon Spacer (Qty 8)
¼″ Nylon Spacer (Small) (Qty 8)
9
/16″ Nylon Spacer (Qty 8)
Nylon Sleeve (Qty 8)
5
/16″ Flat Washer (Metal) (Qty 8)
M8 x 25mm Screw
(Qty 8)
M8 x 30mm Screw
(Qty 8)
M8 x 35mm Screw
(Qty 8)
M8 x 45mm Screw
(Qty 8)
M8 x 70mm Screw
(Qty 4)
Page 4 Visit the Vogel’s website at http://www.vogels.comInstallation Instructions
PFW6852
Features
Stylish Design
Sleek and unobtrusive, yet
supremely sturdy.
Robust Mount Design
The heavy brackets ensure
that your at panel stays
where you installed it.
Smooth Function
Exclusive Radial Glide
Technology™ for effortless motion
Dynamic Viewing
Up to 10° tilt forward
and backward allows for
superior viewing of your at
panel.
Nylon Spacers
Vogel’s uniquely designed spacers
that t multiple screw sizes.
Installation Instructions Visit the Vogel’s website at http://www.vogels.comPage 5
Cable Management
Keeps cables from being pinched
and reduces unsightly cable
clutter.
PFW6852
Installing the Swingout Arm
Introduction
The following procedures instruct you on installing your PFW6852 Universal Swingout Arm on to wall studs or a
concrete wall. Please read these installation instructions once thoroughly before attempting to install your Vogel’s
product.
Please take a minute to familiarize yourself with the contents of the package and make sure you have all the parts and
tools you need to safely complete the installation.
In addition, some steps of this installation may require two people to prevent personal injury and/or damage to your at
panel. Please obey all warnings in the following installation procedure, observe safe installation practices, and utilize
proper safety equipment at all times.
Proceed to the “Mount Orientation” section.
Mount Orientation
Your PFW6852 Universal Swingout Arm is designed to be installed with the Swingout Arm opening to either the
left-hand or right-hand side. Simply invert the PFW6852 Universal Swingout Arm and re-orient the Nose Piece.
Proceed to the “Nose Piece Orientation” section.
Nose Piece
Upright Orientation
Left-Hand Swingout Arm Orientation
Page 6 Visit the Vogel’s website at http://www.vogels.comInstallation Instructions
Right-Hand Swingout Arm Orientation
PFW6852
Installing the Swingout Arm (cont’d)
Nose Piece Orientation
Remove the Nose Piece by removing the tension bolts, tension bolt nuts, and washers.
Detach the Nose Piece assembly, rotate it 180°, and place it back onto your Swingout Arm.
Slide the tension bolts back into the holes and attach the tension bolt nuts and washers from the backside of the
Nose Piece assembly.
Tighten the tension bolts.
Do not overtighten the tension bolts.
Tension Bolt Nuts
and Washers
Tension Bolts
Tension Bolt Nuts
and Washers
Tension Bolts
Nose Piece
The Nose Piece consists of four parts that must stay together in the order that they were manufactured. If they
become separated during any of the Nose Piece Orientation steps, re-assemble the parts in the order shown
If you will be installing your PFW6852 mount on to a wood stud surface, proceed to the “Wood Stud Installation”
section.
If you will be installing your PFW6852 mount on to a concrete surface, proceed to the “Concrete Installation”
section.
If you are installing your PFW6852 mount to wood studs, the drywall must be at least 1/2” thick.
Installation Instructions Visit the Vogel’s website at http://www.vogels.comPage 7
Installing the Swingout Arm (cont’d)
Wood Stud Installation
Refer to the instructions printed on the template
supplied with your PFW6852 mount regarding where
to drill the pilot holes for the lag bolts.
Place your PFW6852 mount against the wall and
align the mounting slots with the pilot holes.
Insert four (4) 5/16″ x 3″ lag bolts and washers into the
pilot holes. Do not completely tighten the lag bolts at
this time.
Place a level on the top rail and make sure that the
mount is level.
Tighten all of the lag bolts.
Do not overtighten the lag bolts.
You must install one (1) lag bolt and washer into a
wood stud at either both mount points A OR both
mount points B...
...AND...
...you must install one (1) lag bolt and washer into
a wood stud at any two (2) mount points C, one (1)
in the top mount point and one (1) in the bottom
mount point.
PFW6852
A
B
C
C
C
Proceed to the “Mounting Hardware Selection” section.
Concrete Installation
Step 1
Concrete wedge anchors must be used for
concrete installation. The anchor should have a
3/8” shaft, 5/16” threading and be 3” in length. This
anchor is available through McMaster-Carr (Part
#97046A114).
You will need a 3/8” concrete drill bit.
Place your Swingout Arm into position against the
wall.
Use a bubble level to level your Swingout Arm.
Mark four holes to be used for securing your Swingout
Arm.
Do not install wedge anchors closer than 12″ in
each elliptical wall bracket.
AC
B
C
C
Page 8 Visit the Vogel’s website at http://www.vogels.comInstallation Instructions
PFW6852
Installing the Swingout Arm (cont’d)
Step 2
Set aside your Swingout Arm.
Use a power drill and concrete drill bit to drill holes at
the marks.
Insert a wedge anchor into each hole.
If necessary, use a hammer to lightly tap each wedge
anchor into place so that they are ush with the wall.
Step 3
Move your Swingout Arm back into position.
Attach the wedge anchor nut and washer onto the
threaded shaft that is protruding from the wall.
Do not tighten any hardware until all wedge anchor
nuts and washers are in place.
Proceed to the “Mounting Hardware Selection” section.
Installation Instructions Visit the Vogel’s website at http://www.vogels.comPage 9
Mounting Hardware Selection
Selecting the Mounting Hardware
Insert a small straw or toothpick into the threaded
inserts found on the back of the at panel.
Use a pencil to mark the depth of the threaded
insert on the small straw or toothpick.
Mark the straw or toothpick 1/8” above the depth of
the threaded insert, as shown in Figure 1.
Insert the small straw or toothpick into the remaining
threaded inserts to compare and verify their depth
using the straw or toothpick’s 1/8” allowance mark.
Locate the correct diameter screw for the threaded
insert.
PFW6852
If the screw you selected is longer than the 1/8”
allowance mark on the small straw or toothpick,
as shown in Figure 2 and Figure 3, do not use
this screw. The screw length must not bypass the
mark.
Test each size of the screws provided.
The correct screws should thread easily into the
mounting point and not pull out when tension is
applied.
You must account for the bracket, spacers and
Griplate™ depths when using the Thread Depth
Indicator to measure the thread depth of your at
panel.
Proceed to the “Griplate™ Washer Installation”
section.
Small Straw
or Toothpick
Small Straw or Toothpick
Marking the 1/8”
Allowance
Depth Plus 1/8” Allowance
Mark
Small Straw
or Toothpick
Depth Plus 1/8” Allowance
Mark
Page 10 Visit the Vogel’s website at http://www.vogels.comInstallation Instructions
PFW6852
Mounting Hardware Selection (cont’d)
Griplate™ Washer Installation
Vogel’s Griplate™ washers are designed to
accommodate the various M4, M5, M6 and M8 hole sizes
required by at panels.
Do not place excessive pressure on the back of the
at panel, as this may damage your at panel.
The Griplate™ washer must be installed between
the head of the mounting screw and the mounting
bracket as shown.
The dimples on the Griplate™ washers must be
oriented as follows:
● The Griplate™ washers installed at the top
of the at panel must have the points of the
dimples facing away from the at panel.
● The Griplate™ washers installed at the bottom
of the at panel must have the points of the
dimples facing towards the at panel.
Does your at panel have:
● Recessed mount points?
● Uneven mount points?
● A curved back?
● Any obstruction near the mount point?
If Yes, you must install nylon spacers. Proceed to the
“Nylon Spacer Installation” section.
If No, skip to the “Mounting Bracket Installation”
section.
Top Griplate™
Dimple Orientation
Mounting Screw
M8
M6
M5
M4
Griplate™
Bracket
Flat Panel
Mount Point
Bottom Griplate™
Dimple Orientation
Nylon Spacer Installation
Vogel’s’ nylon spacers allow you to attach the mounting
bracket to at panels which have recessed or uneven
mount points. Each nylon spacer will add distance
between the mounting bracket and your at panel.
The nylon spacers must only be installed between
the mounting bracket and your at panel.
When using spacers, there must be
at least 10mm of exposed screw thread.
The nylon spacers will t M4, M5, M6 and M8 screw
sizes.
Proceed to the “Mounting Bracket Installation” section.
Mounting Bracket
Griplate™ Washer
Flat Panel
Nylon Spacer
Mount Point
Installation Instructions Visit the Vogel’s website at http://www.vogels.com Page 11
Mounting Bracket Installation
Does your at panel have a mount pattern for the
mount points greater than 506mm high x 876mm wide?
If No, proceed to the “Universal Bracket Installation”
section.
If Yes, proceed to the “Adapter Plate Installation
(Optional)” section.
Your PFW6852 Adapter Plates allow the PFW6852 mount to
accommodate very large at panel mount patterns. Refer to
your at panel User’s Guide for information regarding mount
point distances and patterns.
PFW6852 without Adapters: Width Height
Minimum: 240mm x 120mm
Maximum: 506mm x 876mm
PFW6852 with Adapters: Width Height
Minimum: 200mm x 200mm
Maximum: 985mm x 667mm
Universal Bracket Installation
Step 1
Place the Universal Bracket Bar and the Universal
Brackets on a at surface.
Slide the Universal Brackets onto the Universal
Bracket Bar with the set screws facing up.
Do not tighten the set screws that are located on
the back of each Universal Bracket.
PFW6852
Universal Bracket Bar
Step 2
Place the at panel on a soft, at surface, face-down.
Place nylon spacers over mount points, as
determined in the “Nylon Spacer Installation”
section.
Place the Universal Bracket assembly on the back
of the display, with the Universal Brackets resting
directly over the at panel mount points.
Place a Griplate™ over each mount point and secure
them using the mounting hardware determined in the
“Selecting the Mounting Hardware” section.
Universal Brackets
Page 12 Visit the Vogel’s website at http://www.vogels.comInstallation Instructions
PFW6852
Mounting Bracket Installation (cont’d)
Step 3
Center the Universal Bracket Bar.
Use the 5/32″ Allen wrench to tighten the set screws
that are located on the back of each Universal
Bracket.
Do not overtighten the set screws.
Proceed to “Attaching the Flat Panel to the Swingout
Arm” section.
Adapter Plate Installation (Optional)
Step 1
Attach the Adapter Plates to the at panel using
Griplates™ and the mounting hardware determined in
the “Selecting the Mounting Hardware” and “Nylon Spacer Installation” sections.
Do not tighten the mounting hardware at this time.
Set Screws
If M10 x 30mm mounting screws are needed for
your installation, Griplate™ washers cannot be
used. Please use the four (4) 5/16″ at washers
(supplied) with the M10 x 30mm screws to attach
the adapter plates to the at panel.
Step 2
Slide the Universal Brackets onto the Universal Bracket
Bar with the set screws facing up.
Caution!
Do not tighten the set screws that are located on
the back of each Universal Bracket.
Universal Bracket Bar
Universal Brackets
Installation Instructions Visit the Vogel’s website at http://www.vogels.com Page 13
Mounting Bracket Installation (cont’d)
Step 3
Place the Universal Bracket assembly on the back
of the display, with the threaded mount studs on the
Adapter Plates passing through the mount slots on
the Universal Brackets.
Place one (1) 5/16″ washer and one (1) M8 nylon nut
on each threaded mount stud.
Use a socket wrench and ½″ socket to tighten all
M8 nylon nuts.
Use a screwdriver and tighten the mounting
hardware determined in the “Selecting the
Mounting Hardware” section.
Note!
Make certain that the two Alignment Stubs on
each Adapter Plate are properly seated in the
Universal Bracket slots. The Alignment Stubs
help keep the Universal Bracket assembly aligned
and level during installation.
PFW6852
Universal Bracket
Mount Stub
Alignment Stub
Adapter Plate
Step 4
Center the Universal Bracket Bar.
Use the 5/32″ Allen wrench to tighten the set screws
that are located on the back of each Universal
Bracket.
Caution!
Do not overtighten the set screws.
Proceed to “Attaching the Flat Panel to the Swingout
Arm” section.
Page 14 Visit the Vogel’s website at http://www.vogels.comInstallation Instructions
PFW6852
Attaching the Flat Panel to the Swingout Arm
Step 1
Caution!
The following procedure requires two people.
Warning!
Until you install the M6 x 12mm screw and lock
washer, your at panel can be easily dislodged,
causing severe personal injury and/or property
damage. Use extreme care if you push or pull on
the Swingout Arm.
Lift the at panel/Universal Bracket assembly to the
Swingout Arm.
Slide the hood of the Universal Bracket Bar over the
top of the Nose Piece.
Slowly lower the at panel/mounting bracket
assembly on to the Nose Piece.
Insert and tighten an M6 x 12mm screw and lock
washer to secure the at panel/mounting bracket
assembly to the Swingout Arm.
WARNING!
Do not release the at panel/mounting bracket
assembly until you are certain that hood of the
Universal Bracket Bar is rmly seated on the Nose
Piece.
Step 2
Insert and tighten two (2) M6 x 30mm locking screws
into the bottom of the Nose Piece.
Caution!
Do not overtighten the M6 x 30mm locking screws.
Proceed to the “Fine Tuning & Adjustments” section.
Flat Panel Removed for Clarity
Installation Instructions Visit the Vogel’s website at http://www.vogels.com Page 15
Fine Tuning & Adjustments
Tilt Positioning
Before you can make tilt adjustments, you must loosen
both tension bolt nuts one-half turn.
Adjusting the Tilt Angle
Place one hand at the center top edge of the at
panel.
Place the other hand on the center bottom edge of
the at panel.
Using the upper hand, gently pull the top of the at
panel towards you while the lower hand gently pushes
the bottom of the at panel away from you.
Adjusting the Flat Panel to the Original Position
Place one hand at the center top edge of the at
panel.
Place the other hand on the center bottom edge of
the at panel.
Using the upper hand, gently push the top of the at
panel towards the wall while the lower hand gently
pulls the bottom of the at panel away from the wall.
After making any tilt adjustments, you must tighten the
tension bolt nuts one-half turn.
PFW6852
Cable Management
You can easily route power and data cables through any
of the access points on the Swingout Arm. This not only
helps to prevent cables from being pinched, but helps
hide unsightly cable clutter.
Page 16 Visit the Vogel’s website at http://www.vogels.comInstallation Instructions
PFW6852
34.50
876.3
19.93
506.1
21.00
533.4
3.97
W/O ADAPTERS
4.074
[103.4]
W/ ADAPTERS
100.9
38.77
984.8
39.87
1012.7
26.27
667.3
29.20
741.7
37.20
944.9
26.95
684.6
[662.9]
26.1
26
657.7
10°
10°
.41
10.3
18.43
468.1
22.82
579.6
16.00
406.4
24.00
609.6
Technical Specications
All measurements are in inches.
Installation Instructions Visit the Vogel’s website at http://www.vogels.com Page 17
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.