PREDATAIR
Hydraulic Air Compressor
General Information.......................................................................... 3
Safety Precautions .......................................................................... 3
Installation Instructions ................................................................... 4
Specifications and Components ..................................................... 5
Operating the PREDATAIR .............................................................. 7
Startup ............................................................................................. 7
What to Expect at Startup ............................................................... 7
Shut-down ....................................................................................... 8
Cold Weather Operation ................................................................. 9
Hot Weather Operation ................................................................... 9
Hydraulic Oil .................................................................................... 9
Automatic Shutdown ....................................................................... 9
Display Box Messages .................................................................. 10
System Adjustments ..................................................................... 13
Menu Headings ............................................................................. 13
Troubleshooting ............................................................................. 17
Maintaining the PREDATAIR ......................................................... 20
Adding Compressor Oil ................................................................. 20
Replacing the Air Filter .................................................................. 21
Changing Oil and Filter ................................................................. 22
Changing the Coalescing Filter ..................................................... 23
System Wiring Diagram ................................................................ 25
Warranty .......................................................................................... 26
Maintenance and Repair Records ................................................ 28
Parts Replacement or Adjustment Record ................................... 30
Accessory Products from VMAC .................................................. 32
VMAC – Vehicle Mounted Air Compressors
Toll Free: 1-800-738-8622 Local: 1-250-740-3200
Fax: 1-250-740-3201
2
Document 1930149
Owner’s Manual PREDATAIR Hydraulic Air Compressor
Changes and Revisions
Version
Revision Details
Revised
Approved
Implemented
0
Original manual
IB 14 Sept 2007
SM 03 Dec 2007
07 Dec 2007
A
ECN 08-197
SL 14 July 2008
SM 20 Sep 2010
21 Sep 2010
B
ECN 11-118
MH 23 Sep 2011
SM 30 Sep 2011
4 Oct 2011
C
ECN 14-042
MH 25 Jun 2014
MP/RD 16 Jul 2014
16 Jul 2014
Important Information
The information in this manual is intended for installers who have knowledge and experience in hydraulic system installation and for people with mechanical trade certification who have the tools and equipment to properly and safely perform the installation. Do not attempt this installation if you do not have the appropriate mechanical training, knowledge and experience. If you have difficulty with the installation, contact VMAC.
Follow all safety precautions and standard shop practices for mechanical work.
The VMAC warranty form must be completed and mailed or faxed to VMAC at the time of installation for any subsequent warranty claim to be considered valid.
To order parts, contact your VMAC dealer. Your dealer will ask for the VMAC serial number, part number, description and quantity. To locate your nearest dealer, call 1-800-738-8622.
Copyright 2008
All trademarks used in this manual are the property of the respective copyright holder.
The contents of this manual may not be reproduced in any form without the express
written permission of VMAC, 1333 Kipp Road, Nanaimo, BC V9X 1R3.
Printed in Canada
VMAC – Vehicle Mounted Air Compressors Toll Free: 1-800-738-8622 Local: 1-250-740-3200 Fax: 1-250-740-3201
3
General Information
Safety Precautions
Observe the following general safety rules:
pay attention to operations; do not leave the equipment
unattended
follow safe work practices and wear the appropriate safety
equipment when operating air-powered equipment, particularly eye and hearing protection
avoid all contact with pressurized air, because if it penetrates
your skin it can enter your bloodstream and kill you
to prevent compressor explosion or fire, make sure that the
air entering the compressor is free of flammable vapors
vaporized oil propelled by high-pressure air is an explosive
mixture
do not breathe the compressor air, vaporized oil is a
respiratory hazard
stay clear of all moving parts
Observe these rules when operating the compressor:
do not bypass or disable the oil temperature sensors do not expose the tank or compressor to extreme heat do not perform any service until the system has been
completely blown-down and you have verified that all air has
been discharged do not repair or service a pressurized system maintenance and repair on system components should only
be performed by qualified personnel the vehicle must be in park (for automatic transmissions) or
neutral (for manual transmissions) with the park brake or air
spring brake fully applied before starting the compressor and
at all times during compressor operation use a regulator in the output line to precisely control the final
air delivery pressure do not operate the compressor while driving do not tamper with the pressure relief valve do not attempt to repair or modify any component
VMAC – Vehicle Mounted Air Compressors
Toll Free: 1-800-738-8622 Local: 1-250-740-3200
Fax: 1-250-740-3201
4
Installation Instructions
Detailed information is provided in a separate publication, Installation Manual PREDATAIR Hydraulic Compressor, which provides specific
information for each different application. This information includes recommendations and other important
information for correct installation. The information in the installation manual is intended for use by trained, professional technicians with the knowledge, tools, and equipment to do the job properly and safely. Installation should not be performed by persons without the appropriate skills.
Do not attempt to install the PREDATAIR without the appropriate installation manual.
As part of the installation process, ensure that the Operation Instruction Card is affixed near the PREDATAIR in an obvious location so that users can easily see it and refer to the procedures.
VMAC – Vehicle Mounted Air Compressors Toll Free: 1-800-738-8622 Local: 1-250-740-3200 Fax: 1-250-740-3201
5
Specifications and Components
This is a flooded-lobe, rotary screw compressor (filled with VMAC certified and approved synthetic oil) driven by a hydraulic motor. Compression occurs when inlet air (at normal atmospheric pressure) enters a chamber where it is trapped between the rotating rotor lobes. A lubricated pitch line provides sealing. As the lobes mesh, they reduce the volume of the air, compressing it to the desired pressure.
The system has a two-stage air/oil separator. The first separation stage consists of baffles, which perform mechanical separation. The second stage uses a coalescing element, which delivers dry air to the outlet.
Pressure regulation is achieved with a mechanical inlet control valve and an adjustable pressure regulator.
The compressor is protected by a paper-type replaceable air filter and a spin-on type oil filter. Oil is removed from the delivered service air by a coalescing separator element.
Safety features include:
2,800 psi hydraulic pressure relief valve for Predatair40/60 3,300 psi hydraulic pressure relief valve for Predatair60 HHP 200 PSI relief valve in oil/air tank blow-down valve to discharge system pressure on shutdown temperature safety sensors in the compressor, hydraulic oil
discharge from the cooler and hydraulic oil return at the
manifold
Do not disable or bypass the over-temperature shutdown circuit. Failure of the shutdown system could result in equipment damage, injury or death.
A liquid-to-air cooler maintains operating temperatures in an optimal performance range which increases system durability and reduces the temperature of the compressed air. Ventilation is critical for proper operation. See the Installation Manual PREDATAIR Hydraulic Compressor for details.
The system pressure is factory-set at 150 psi. Pressure can be adjusted between 100 and 150 psi by using the display box. To reduce the operating pressure, use a Filter Regulator Lubricator (FRL).
VMAC – Vehicle Mounted Air Compressors
Toll Free: 1-800-738-8622 Local: 1-250-740-3200
Fax: 1-250-740-3201
6
Compressor air filter (must have proper ventilation)
Oil cooler (inside cover, must have proper ventilation)
Air discharge port with check valve
Hydraulic fluid inlet
Hydraulic fluid return
Blowdown cap with internal coalescing filter
Minimum clearance for servicing - 6 inches
Compressor oil fill (shipped full from
the factory) Oil level sight glass (make sure this can be easily accessed for daily inspection)
Compressor oil drain
Oil filter
Cooling fan
Minimum clearance
for servicing - 6 inches
Pressure sensor
VMAC – Vehicle Mounted Air Compressors Toll Free: 1-800-738-8622 Local: 1-250-740-3200 Fax: 1-250-740-3201
7
Operating the PREDATAIR
Startup
1. If installed inside a cabinet or enclosure, open the door or cover completely and secure in the open position to provide proper ventilation. Refer to the installation manual for instructions on installing a wiring interlock to prevent operation when the door or cover is closed.
2. Open the hydraulic shut-off valve (if equipped).
3. Check the compressor oil level at the sight glass in the tank and the hydraulic oil level in the hydraulic system tank.
4. Turn on power to the PREDATAIR.
5. Engage the hydraulic system.
6. Start the PREDATAIR with the “ON” switch on the display box.
7. Watch the display for system status information.
8. If a cold climate kit (A700146) is installed, it will automatically activate in cold weather.
What to Expect at Startup
1. The green light on the display box will illuminate.
2. If the temperature is below -13°F (-25°C) the green light will slowly blink and the display will read “HYD OIL TOO COLD. The hydraulic oil must be preheated before the cold climate kit will activate.
If the temperature is between -13°F (-25°C) and 5°F (-15°C) the green light will slowly blink and the display will read “HYD OIL WARMING, HYD XXXF/XXXC”.
if a cold climate kit is installed it will energize to speed warm-
up of the hydraulic oil
if the system has been wired for two-speed operation, the
engine will idle up after 10 seconds to speed warm-up of the hydraulic oil
Once the temperature of the hydraulic oil is above 5°F (-15°C), the cold climate kit will turn off and the idle will drop and startup will proceed normally. The display will indicate this with “SOFT START XXC”.
VMAC – Vehicle Mounted Air Compressors
Toll Free: 1-800-738-8622 Local: 1-250-740-3200
Fax: 1-250-740-3201
8
3. The compressor will activate and build air pressure to approximately 40 psi until the compressor has reached operating temperature.
4. When the compressor reaches operating temperature it will “load up” and build air pressure to system pressure, (120psi). If the system has been wired for two-speed operation, the engine will speed up to build air pressure faster. If the hydraulic oil has not reached 41°F (5°C), or the compressor has not reached 70°C (158°F), air pressure will only build to 120 psi to reduce the load on the hydraulic system. The compressor can still be used during this stage of operation.
5. Once the system reaches full pressure, the compressor will unload and, if the engine speed had increased, it will drop to base speed to unload the hydraulic system. You may hear a hiss as air pressure is reduced to approximately 40 psi. If air pressure does not drop below the restart point after two minutes, the hydraulic motor will turn off and the display will read “STANDBY XXX PSI”. This delay time is adjustable.
6. When air is used and the pressure drops, the sequence of load up and unload will repeat, along with truck engine speed if the system is wired for two speed operation. The system may restart occasionally even without air use to maintain correct compressor operating temperatures.
A small reservoir is recommended to reduce cycling between the load and unload modes.
Shut-down
1. When operations are complete, stop the PREDATAIR with the OFF” button. Residual pressure in the compressor will blow­down automatically.
2. Disengage the hydraulic system.
3. Close the hydraulic shut-off valve (if equipped).
4. Turn off the power supply to the PREDATAIR.
VMAC – Vehicle Mounted Air Compressors Toll Free: 1-800-738-8622 Local: 1-250-740-3200 Fax: 1-250-740-3201
9
Cold Weather Operation
The compressor will not start if the hydraulic oil temperature is lower than 5 F (-15 C). Refer to the installation manual for more detailed
information. Observe the following precautions:
if temperatures are below 41 F (5 C), cover the PREDATAIR
during transit (if exposed) and pre-heat by circulating hydraulic oil through the system before starting the compressor
if temperatures are below 5 F (-15 C), install a cold climate kit
(A700146) and circulate the hydraulic oil through the system
do not allow ice or snow to build up around the air filter and inlet
control valve
Hot Weather Operation
Thermal protection will prevent operation if the temperature is too high:
If temperatures are above 100 F (37 C), reduce the compressor
duty cycle. Provide additional hydraulic oil cooling. Provide proper ventilation if the compressor is inside a cabinet or
enclosure. Cool air results in better performance and higher
CFM.
Hydraulic Oil
Use hydraulic oil that is correctly rated for the operational temperature range of the equipment.
Automatic Shutdown
If the compressor or hydraulic oil gets too hot, the over-temperature circuit will disengage the hydraulic system, preventing operation. The red indicator light will illuminate and the display box will show a message identifying the problem.
If this problem persists, refer to the troubleshooting section in this manual.
1. Turn the compressor switch to the “OFF” position.
VMAC – Vehicle Mounted Air Compressors
Toll Free: 1-800-738-8622 Local: 1-250-740-3200
Fax: 1-250-740-3201
10
2. Allow a few minutes for the air system to vent pressure and for the oil to drain back to the tank, then check the oil level through the sight-glass on the compressor tank. Oil level must be checked with the vehicle in a level position, not on a slope. If the oil level is low, add compressor oil until the correct level is reached.
3. Check the hydraulic oil to ensure that it is not low; add hydraulic oil until the correct level is reached.
Display Box Messages
System Check
The display will show:
VMAC – WWW.VMACAIR.COM
Both red and green lights will flash. The display will show:
SYSTEM CHECK / SYSTEM READY
The system will go to the Ready State.
Ready State
The display will scroll through the following messages:
VMAC PH# 250 740 3200
HRS:XXXX:XX If the system is due for a 500 hr service, it will display:
HRS:XXXX:XX 500S
Additional possible messages:
WARM HYD OIL If the hydraulic oil temperature is below +5 F(–15 C).
CHECK AIR FILTER Every 100 hrs the system will remind the operator.