Vlinx VESR9xx, VESR901-x, VESR902T-x, VESR902D-x User Manual

Manual Document Number: VESR9xx 4210m
www.bb-elec.com
www.bb-europe.com
i
V
Vllii
n
n
x
x
V
V
R
R
9
9
x
x
x
x
S
Seerriiaall
S
Seerrvveerrss
Vlinx Serial Servers
Model VESR9xx
Documentation Number: VESR9xx-4210m
This product designed and manufactured in Ottawa, Illinois USA
using domestic and imported parts by
International Headquarters
707 Dayton Road - P.O. Box 1040 - Ottawa, IL 61350 USA
Phone (815) 433-5100 - General Fax (815) 433-5105
Website: www.bb-elec.com
European Headquarters
B&B Electronics
Westlink Commercial Park - Oranmore, Co. Galway, Ireland
Phone +353 91-792444 - Fax +353 91-792445
Website: www.bb-europe.com
B&B Electronics Mfg. Co. Inc – October 2010
©2010 B&B Electronics Mfg Co Inc No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photography, recording, or any information storage and retrieval system without written consent. Information in this manual is subject to change without notice, and does not represent a commitment on the part B&B Electronics Mfg Co Inc. B&B Electronics Mfg Co Inc shall not be liable for incidental or consequential damages resulting from the furnishing, performance, or use of this manual. All brand names used in this manual are the registered trademarks of their respective owners. The use of trademarks or other designations in this publication is for reference purposes only and does not constitute an endorsement by the trademark holder.
Manual Document Number: VESR9xx 4210m
www.bb-elec.com www.bb-europe.com
ii
Manual Document Number: VESR9xx 4210m
www.bb-elec.com
www.bb-europe.com
iii
TTaabbllee ooff CCoonntteennttss
1. Introduction ...................................................................................................... 1
About VESR9xx Serial Servers ........................................................................................... 1
VESR9xx Serial Server Model Numbering .......................................................................... 2
List of VESR9xx Serial Server Models ................................................................................ 3
VESR9xx Serial Server Features ........................................................................................ 5
Vlinx Manager Configuration Software ................................................................................ 5
2. VESR9xx Serial Server Hardware ................................................................... 7
Package Checklist ............................................................................................................... 7
VESR9xx Serial Server Enclosures and Mounting .............................................................. 7
LED Indicators(VESR90x) ................................................................................................... 8
Link LED ................................................................................................................... 8
Ready LED ................................................................................................................ 8
Serial Port LEDs ....................................................................................................... 8
LED Indicators (VESR92x) .................................................................................................. 9
Mode Switch ...................................................................................................................... 10
Ethernet Connector ........................................................................................................... 11
Fiber Optic Connectors ..................................................................................................... 11
Serial Port Connectors ...................................................................................................... 12
Power Connector ............................................................................................................... 13
Mounting Hardware ........................................................................................................... 13
3. Serial Server Setup and Connections .......................................................... 15
Connecting the Power Supply ........................................................................................... 15
Connecting VESR9xx Serial Servers to Serial Devices .................................................... 15
Connecting the VESR901-x ..................................................................................... 16
Connecting the VESR902T-x ................................................................................... 17
Connecting the VESR902D-x .................................................................................. 18
Connecting VESR9xx Serial Servers to a Network ........................................................... 18
Network Connection (10BaseT/100BaseTX) ........................................................... 18
Fiber Optic Connection .......................................................................................... 18
VESR9xx Serial Server Configuration Connections .......................................................... 20
Configuring the VESR9xx Serial Server via the Network Connection .................... 20
Configuring the VESR9xx Serial Server via the Serial Port (Console Mode) ......... 21
VESR9xx Serial Server Operational Connections ............................................................. 22
Using VESR9xx Serial Servers in Direct IP Mode .................................................. 23
Using VESR9xx Serial Servers in Virtual COM Port Mode .................................... 23
Using VESR9xx Serial Servers in Paired Mode ...................................................... 24
Initiating a Hardware Reset on the Serial Server .............................................................. 25
Reloading Factory Defaults ............................................................................................... 25
4. Description of Serial Server Properties ....................................................... 27
Baud Rate ......................................................................................................................... 27
Character Count ................................................................................................................ 27
Configuration Files ............................................................................................................ 27
Data/Parity/Stop ................................................................................................................ 28
Manual Document Number: VESR9xx 4210m
www.bb-elec.com www.bb-europe.com
iv
Default Gateway ................................................................................................................ 28
Delimiter 1, Delimiter 2 and Delimiter Removal ................................................................. 28
Delimiter 1 .............................................................................................................. 28
Delimiter 2 .............................................................................................................. 28
Delimiter Removal .................................................................................................. 29
How Delimiters Work ............................................................................................. 29
DHCP ................................................................................................................................ 29
Firmware Version .............................................................................................................. 30
Flow Control ...................................................................................................................... 30
Forced Transmit ................................................................................................................ 30
Hardware Version .............................................................................................................. 30
Inter-character Timeout ..................................................................................................... 31
IP Address ......................................................................................................................... 31
Link Status ......................................................................................................................... 34
MAC Address .................................................................................................................... 34
Model ................................................................................................................................. 34
Network Protocols ............................................................................................................. 34
Network Watchdog ............................................................................................................ 34
Paired Mode ...................................................................................................................... 35
Password ........................................................................................................................... 35
Serial Interface Modes ...................................................................................................... 35
Serial Server Name ........................................................................................................... 36
Server Serial Port Number ................................................................................................ 36
Serial Watchdog ................................................................................................................ 36
Subnet Mask ..................................................................................................................... 37
TCP (Transmission Control Protocol) ................................................................................ 37
UDP (User Datagram Protocol) ......................................................................................... 38
VCOM (Virtual COM Port) ................................................................................................. 38
5. Upgrading the Serial Server Firmware ......................................................... 39
Downloading Firmware Files ............................................................................................. 40
Uploading the Firmware to the Serial Server .................................................................... 40
6. Diagnostics ..................................................................................................... 42
Testing a Serial Server Connection ................................................................................... 43
Testing a Virtual COM Port ............................................................................................... 44
7. Appendix A: Default Server Settings ............................................................ 45
8. Appendix B: Product Specifications ............................................................ 46
General Specifications ............................................................................................ 46
Controls, Indicators and Connector Specifications ................................................ 47
Serial Interface Specifications ................................................................................ 48
Network Specifications ............................................................................................ 49
9. Appendix C: Dimensional Diagrams ............................................................ 50
10. Appendix D: Connector Pinouts ................................................................... 55
VESR901-x Serial Port Pinouts .............................................................................. 55
VESR902D-x Serial Port Pinouts ............................................................................ 57
VESR902T-x Serial Port Pinouts ............................................................................ 58
Manual Document Number: VESR9xx 4210m
www.bb-elec.com
www.bb-europe.com
v
Standard Ethernet Cable RJ-45 Pin-out ................................................................. 59
Introduction
Manual Document Number: VESR9xx-4210m
www.bb-elec.com
www.bb-europe.com
1
1.1. Introduction
Introduction
Thank you for purchasing a VESR9xx Serial Server product! This product has been manufactured to the highest standards of quality and performance to ensure your complete satisfaction.
Figure 1. A VESR902T Serial Server
About VESR9xx Serial Servers
VESR9xx Serial Servers connect serial devices (RS-232, RS-422 or RS-
485) to Ethernet networks, allowing the serial device to become a node on the network. The serial ports can be accessed over a LAN/WAN using Direct IP Mode, Virtual COM Port, or Paired Mode connections. VESR9xx Serial Servers feature 10BaseT or 100BaseTX copper network media and several fiber optic media options, depending on the model. VESR92x serial servers feature an additional copper Ethernet pass-through port. VESR9xx Serial Servers are built for use in industrial environments, featuring an IP30 approved slim line DIN rail mountable case. They operate from a range of DC power supply voltages and feature pluggable terminal block power connectors.
Introduction
VESR9xx Serial Server Model Numbering
VESR9xx Serial Server are a growing family of products. Models are available with one or two serial connections and one or two Ethernet connections. Network connection options include 10BaseT/100BaseTX copper or several differen t f iber optic op tions ( on mod els with a p ass- thr ough port, the pass-through port is copper). The following diagram shows the model numbering scheme:
Manual Document Number: VESR9xx-4210m
www.bb-elec.com www.bb-europe.com
2
Introduction
Manual Document Number: VESR9xx-4210m
www.bb-elec.com
www.bb-europe.com
3
List of VESR9xx Serial Server Models
The following table lists the various VESR9xx Serial Server models available.
Model Number Features
VESR901 Vlinx , 1PORT, DB9, ESS, DIN, CU ETHERNET
VESR901-SC Vlinx , 1PORT, DB9, ESS, DIN, FIBER, SC VESR901-SC40 Vlinx , 1PORT, DB9, ESS, DIN, FIBER, SC, 40KM VESR901-SC80 Vlinx , 1PORT, DB9, ESS, DIN, FIBER, SC, 80KM
VESR901-ST Vlinx , 1PORT, DB9, ESS, DIN, FIBER, ST
VESR901-ST40 Vlinx , 1PORT, DB9, ESS, DIN, FIBER, ST, 40KM VESR901-ST80 Vlinx , 1PORT, DB9, ESS, DIN, FIBER, ST, 80KM
VESR901-MC Vlinx , 1PORT, DB9, ESS, DIN, FIBER, MULTIMODE, SC
VESR901-MT Vlinx , 1PORT, DB9, ESS, DIN, FIBER, MULTIMODE, ST
VESR902D Vlinx , 2PORT, DB9, ESS, DIN, CU ETHERNET
VESR902D-SC Vlinx , 2PORT, DB9, ESS, DIN, FIBER, SC VESR902D-SC40 Vlinx , 2PORT, DB9, ESS, DIN, FIBER, SC, 40KM VESR902D-SC80 Vlinx , 2PORT, DB9, ESS, DIN, FIBER, SC, 80KM
VESR902D-ST Vlinx , 2PORT, DB9, ESS, DIN, FIBER, ST VESR902D-ST40 Vlinx , 2PORT, DB9, ESS, DIN, FIBER, ST, 40KM VESR902D-ST80 Vlinx , 2PORT, DB9, ESS, DIN, FIBER, ST, 80KM
VESR902D-MC Vlinx , 2PORT, DB9, ESS, DIN, FIBER, MULTIMODE, SC
VESR902D-MT Vlinx , 2PORT, DB9, ESS, DIN, FIBER, MULTIMODE, ST
VESR902T Vlinx , 2PORT, TB, ESS, DIN, CU ETHERNET
VESR902T-SC Vlinx , 2PORT, TB, ESS, DIN, FIBER, SC VESR902T-SC40 Vlinx , 2PORT, TB, ESS, DIN, FIBER, SC, 40KM VESR902T-SC80 Vlinx , 2PORT, TB, ESS, DIN, FIBER, SC, 80KM
VESR902T-ST Vlinx , 2PORT, TB, ESS, DIN, FIBER, ST VESR902T-ST40 Vlinx , 2PORT, TB, ESS, DIN, FIBER, ST, 40KM VESR902T-ST80 Vlinx , 2PORT, TB, ESS, DIN, FIBER, ST, 80KM
VESR902T-MC Vlinx , 2PORT, TB, ESS, DIN, FIBER, MULTIMODE, SC
VESR902T-MT Vlinx , 2PORT, TB, ESS, DIN, FIBER, MULTIMODE, ST
VESR921 VLINX, 1PORT, DB9, ESS, DIN, 2 CU ETHERNET
VESR921-MC VLINX, 1PORT, DB9, ESS, DIN, FIBER, MULTI, SC, CU
VESR921-MT VLINX, 1PORT, DB9, ESS, DIN, FIBER, MULTI, ST, CU
Introduction
Manual Document Number: VESR9xx-4210m
www.bb-elec.com www.bb-europe.com
4
Model Number Features
VESR921-SC VLINX, 1PORT, DB9, ESS, DIN, FIBER, SC, CU VESR921-SC40 VLINX, 1PORT, DB9, ESS, DIN, FIBER, SC, 40KM, CU VESR921-SC80 VLINX, 1PORT, DB9, ESS, DIN, FIBER, SC, 80KM, CU
VESR921-ST VLINX, 1PORT, DB9, ESS, DIN, FIBER, ST, CU VESR921-ST40 VLINX, 1PORT, DB9, ESS, DIN, FIBER, ST, 40KM, CU VESR921-ST80 VLINX, 1PORT, DB9, ESS, DIN, FIBER, ST, 80KM, CU
VESR922T VLINX, 2PORT, TB, ESS, DIN, 2 CU ETHERNET
VESR922T-MC VLINX, 2PORT, TB, ESS, DIN, FIBER, MULTI, SC, CU
VESR922T-MT VLINX, 2PORT, TB, ESS, DIN, FIBER, MULTI, ST, CU
VESR922T-SC VLINX, 2PORT, TB, ESS, DIN, FIBER, SC, CU VESR922T-SC40 VLINX, 2PORT, TB, ESS, DIN, FIBER, SC, 40KM, CU VESR922T-SC80 VLINX, 2PORT, TB, ESS, DIN, FIBER, SC, 80KM, CU
VESR922T-ST VLINX, 2PORT, TB, ESS, DIN, FIBER, ST, CU VESR922T-ST40 VLINX, 2PORT, TB, ESS, DIN, FIBER, ST, 40KM, CU VESR922T-ST80 VLINX, 2PORT, TB, ESS, DIN, FIBER, ST, 80KM, CU
Introduction
Manual Document Number: VESR9xx-4210m
www.bb-elec.com
www.bb-europe.com
5
VESR9xx Serial Server Features
Three series models
VESR9x1-x (single serial port)
VESR9x2D-x (two serial ports with DB9M)
VESR9x2T-x (two serial ports with pluggable terminal blocks)
Fiber models available for each of the above series Ethernet pass through ports are available on VESR92x series models. Multi-interface serial ports DB-9M and pluggable terminal block serial port connector options All ports are software selectable as RS-232, RS-422 or RS-485 2- and 4-wire Configuration can be done via network or direct serial conn ect i on Slim line DIN rail mountable case Accepts DC power over a wide voltage range 10/100 Mbps Ethernet with Auto Selection LAN and WAN Communications TCP Client or Server, or UDP operation - configurable Virtual COM port and Paired Mode capabilities Firmware Upload for future revisions/upgrades Software Support - Windows 2000, XP (32/64 bit), 2003 Server (32/64 bit), Vista
(32/64 bit), 2008 Server (32/64 bit), Windows 7 (32/64 bit) Configuration of Ethernet and serial port settings using Vlinx Manager software
Vlinx Manager Configuration Software
Vlinx Manager configuration software enables you to find connected serial servers, configure them, upgrade serial server firmware, and save/load configuration files. It features a graphical user interface (GUI) that is convenient and easy to use. The software also makes it easy to add and remove virtual COM ports on your computer.
Hardware
Manual Document Number: VESR9xx-4210m
www.bb-elec.com
www.bb-europe.com
7
2.2. VESR9xx Serial Server Hardware
VESR9xx Serial Server Hardware
VESR9xx Serial Servers are enclosed in DIN rail mountable enclosures and feature LED indicators, power, Ethernet and serial connectors and a recessed Mode switch.
Package Checklist
VESR9xx Serial Servers are shipped with the following items included:
VESR9xx Serial Server Module Quick Start Guide CD with User Manual, Quick Start Guide and firmware
VESR9xx Serial Server Enclosures and Mounting
All VESR9xx Serial Server models are built into similar enclosures. Modules are DIN rail mountable.
Figure 2. Front View of the VESR922T and VESR902T Serial Server
Hardware
LED Indicators(VESR90x)
VESR9xx Serial Servers have three LED indicators: a Link LED, a Ready LED and two Serial Port LEDs.
Figure 3. LEDs on 1 and 2 Port Serial Servers
Link LED
The Link LED illuminates (green) if the Ethernet connection is operating in 100BaseTX mode. The LED is off if the mode is 10BaseT. When the LED is blinking it indicates that there is data traffic on the Ethernet link.
Ready LED
The Ready LED (green) blinks once per second if the system is operating correctly. If the LED is off, it indicates the system is not operating correctly.
Serial Port LEDs
VESR901-x serial servers feature one serial port. VESR902D,and VESR902T-x serial servers feature two serial ports. Each serial port has an associated LED. Serial Port LEDs blink (green) when data is being transmitted or received on the serial port. When the LED is On it indicates the serial port is open.
Manual Document Number: VESR9xx-4210m
www.bb-elec.com www.bb-europe.com
8
Hardware
LED Indicators (VESR92x)
VESR92x Serial Servers have four LED indicators: E1 and E2 LEDs, a Ready LED and two Serial Port LEDs.
Figure 4. LEDs on 1 and 2 Port Serial Servers
E1 and E2 LEDs
The E1 and E2 LEDs illuminate (green) if the Ethernet connection is operating in 100BaseTX mode. The LEDs are off if the mode is 10BaseT. When the LED is blinking it indicates that there is data traffic on the Ethernet link.
Ready LED
The Ready LED (green) blinks once per second if the system is operating correctly. If the LED is off, it indicates the system is not operating correctly.
Serial Port LEDs
VESR921-x serial servers feature one serial port. VESR922x, serial servers feature two serial ports. Each serial port has an associated LED. Serial Port LEDs blink (green) when data is being transmitted or received on the serial port. When the LED is On it indicates the serial port is open.
Manual Document Number: VESR9xx-4210m
www.bb-elec.com
www.bb-europe.com
9
Hardware
Mode Switch
A recessed momentary reset switch is located on the top of the enclosure. To activate the switch, insert a small plastic tool through the hole in the enclosure and press lightly.
Figure 5. Top View of the Serial Server
The Mode switch can be used to:
Initiate a Hardware Reset Enter Console Mode Reload factory defaults
Note: Refer to Section 3. Serial Server Setup and Connections for more information on using the Mode switch.
Manual Document Number: VESR9xx-4210m
www.bb-elec.com www.bb-europe.com
10
Hardware
Ethernet Connector
Serial server models using 10BaseT/100BaseTX network connections use an RJ45 receptacle. The serial server is connected to a standard Ethernet network drop using a straight-through RJ45 (male) Ethernet cable. VESR92x models feature a second RJ45 receptacle which acts an Ethernet pass-through connection. This connection functions similar to an Ethernet switch and allows the connection of other devices to the network.
Figure 6. Ethernet Connector
Note: Refer to Appendix D for connection pin-outs.
Fiber Optic Connectors
Serial server models using fiber Optic network connections use either SC or ST connectors, depending on the specific model.
Figure 7. SC and ST Fiber Optic Cable Connectors
Manual Document Number: VESR9xx-4210m
www.bb-elec.com
www.bb-europe.com
11
Hardware
Serial Port Connectors
VESRxx Serial Servers use three serial port connector configurations, depending on the model:
VESR901-x serial servers feature one serial port and use a DB-9M connector for RS­232 and a five-position removable terminal block for RS-422 and RS-485 connections.
VESR902D-x serial servers feature two serial ports, both using DB-9M connectors for RS-232, RS-422 and RS-485 connections.
VESR902T-x serial servers feature two serial ports, both using five-position removable terminal blocks for RS-232, RS-422 and RS-485 connections.
Figure 8. DB-9 Female Serial Port Connector with Pinout
Figure 9. Five-Position Pluggable Terminal Blocks
Note: Refer to Appendix D for connection pin-outs.
Manual Document Number: VESR9xx-4210m
www.bb-elec.com www.bb-europe.com
12
Hardware
Power Connector
The power connector is a 5.08 mm 2-position pluggable terminal block.
Figure 10. Power Connection
Mounting Hardware
VESR9xx Serial Server modules can be DIN rail mounted. The DIN mounting clip and spring is included on each module.
Figure 11. DIN Clip on a Serial Server Module
Manual Document Number: VESR9xx-4210m
www.bb-elec.com
www.bb-europe.com
13