Vivax Metrotech vLocPro2, vLocML2 User Handbook Manual

vLoc Series 2 User Handbook (vLocPro2, vLocML2)
(English Edition)
Version 1.4
Table of Content
1. General Safety & Care Information ....................................................................................... 1
1.1 Who Can Use This Equipment ................................................................................................ 1
1.2 Work-site Safety ...................................................................................................................... 1
1.3 Equipment Safety .................................................................................................................... 1
1.4 Batteries and Environmental Safety ........................................................................................ 1
1.4.1 Alkaline Batteries (Non Rechargeable) ................................................................................ 1
1.4.2 Nickel Metal Hydride Batteries (Rechargeable) ................................................................... 1
1.4.3 Lithium-Ion Batteries (Rechargeable) .................................................................................. 2
1.4.4 Lithium Metal Batteries (Non Rechargeable) ....................................................................... 2
1.4.5 General Rules Regarding Disposal of Batteries ................................................................... 2
1.4.6 Transportation of Lithium-ion and Lithium Metal Batteries ................................................... 2
1.5 Care of Equipment .................................................................................................................. 3
1.6 Care When Interpreting the Information Provided by the Locator ........................................... 3
1.7 American & Canadian Safety Notices ..................................................................................... 3
2. Service & Support ................................................................................................................. 4
2.1 Serial Number and Software Revision Number ....................................................................... 4
2.2 Distributors and Service Centers Closest to You: ................................................................... 5
3. vLocPro2 Receiver ............................................................................................................... 6
3.1 vLocPro2 Receiver .................................................................................................................. 6
3.2 Charging the Receiver Batteries ............................................................................................. 7
3.3 vLocPro2 Receiver Main Display ............................................................................................ 8
3.4 vLocPro2 Receiver Screen Shots ........................................................................................... 9
3.5 Locating Mode (Response) ................................................................................................... 10
3.5.1 Peak Response Mode ....................................................................................................... 10
3.5.2 Broad Peak Mode .............................................................................................................. 10
3.5.3 Null Mode........................................................................................................................... 10
3.5.4 Peak with Arrows Response Mode .................................................................................... 11
3.5.5 Sonde Mode ...................................................................................................................... 12
3.6 Audio ..................................................................................................................................... 12
3.7 Sensitivity Control ................................................................................................................. 12
3.8 Frequency Selection ............................................................................................................. 13
3.9 Information Pushbutton (Depth & Current) ............................................................................ 14
3.10 Information Pushbutton (Setup Menu) .................................................................................. 14
4. vLocML2 Receiver .............................................................................................................. 15
4.1 Introduction ........................................................................................................................... 15
4.2 Operating the vLocML2 ......................................................................................................... 16
4.2.1 Switching Between Configuration ...................................................................................... 16
4.2.2 Standard ............................................................................................................................ 16
4.2.3 Dedicated........................................................................................................................... 16
4.2.4 Marker Depth Estimation in Dedicated Mode ..................................................................... 18
4.2.5 Dual Configuration ............................................................................................................. 19
5. Data Logging ...................................................................................................................... 20
5.1 Bluetooth ............................................................................................................................... 20
5.1.1 Fitting the Bluetooth Module .............................................................................................. 20
5.2 Holux GPS Device Overview ................................................................................................ 21
5.2.1 Pairing with the vLocPro2/vLocML2 Receivers .................................................................. 21
5.2.2 Gathering Data in Active Modes ........................................................................................ 22
5.2.3 Gathering Data in Power and Radio (Passive) Modes ....................................................... 22
5.2.4 Transferring Data from the Locator to a Computer ............................................................ 22
5.3 Trimble ProXT/XH ................................................................................................................. 23
5.3.1 Trimble ProXT/XH Setting up Procedure ........................................................................... 23
5.3.2 Transferring Data from the vLoc2 to a Computer ............................................................... 24
5.4 MyLocator2 ........................................................................................................................... 25
5.4.1 Launch the Application ...................................................................................................... 25
5.4.2 Splash Screen ................................................................................................................... 26
5.4.3 Upload Data Files .............................................................................................................. 27
5.4.4 Software Update ................................................................................................................ 28
5.4.5 Advanced Configuration Tool ............................................................................................. 29
5.4.6 Switch On/Off User Menu Settings .................................................................................... 30
5.4.7 Switching On/Off Frequency Selections ............................................................................ 31
5.4.8 Saving a Configuration ...................................................................................................... 31
5.4.9 Configuration Lock Dongle................................................................................................. 32
5.4.10 Icon Summary .................................................................................................................... 34
6. Loc-10Tx Transmitter .......................................................................................................... 35
6.1 Loc-10Tx Transmitter Overview ............................................................................................ 35
6.2 Transmitter Battery ................................................................................................................ 36
6.2.1 Removing the Battery Tray ................................................................................................ 36
6.2.2 Replacing the Alkaline Battery ........................................................................................... 36
6.2.3 Rechargeable Batteries ..................................................................................................... 36
6.2.4 Re-fitting the Battery Tray .................................................................................................. 37
6.2.5 Battery Charging and Disposal .......................................................................................... 37
6.2.6 Battery Condition Indication ............................................................................................... 37
6.3 Transmitting Modes ............................................................................................................... 38
6.3.1 Induction Mode .................................................................................................................. 38
6.3.2 Direct Connection Mode .................................................................................................... 38
6.3.3 Clamp Mode ...................................................................................................................... 39
6.3.4 Connection Block ............................................................................................................... 39
6.3.5 Frequencies and Power Output ......................................................................................... 40
6.3.6 Most Used Frequencies (Frequency Selection) Feature .................................................... 41
6.3.7 "Dual frequency" Mode ...................................................................................................... 42
6.4 Information ............................................................................................................................ 42
7. Loc-5Tx Transmitter ............................................................................................................ 43
7.1 Pushbutton ............................................................................................................................ 43
7.2 External Connectors .............................................................................................................. 43
7.3 Transmitter Battery ................................................................................................................ 43
7.3.1 Removing the Battery Tray ................................................................................................ 43
7.3.2 Replacing Alkaline Batteries .............................................................................................. 44
7.3.3 Rechargeable Batteries ..................................................................................................... 44
7.3.4 Re-fitting the Battery Tray .................................................................................................. 44
7.3.5 Battery Charging and Disposal .......................................................................................... 44
7.3.6 Battery Condition Indication ............................................................................................... 44
7.4 Display .................................................................................................................................. 45
7.5 Multi Frequencies .................................................................................................................. 46
7.6 Most Used Frequencies (Frequency Selection) Feature ....................................................... 46
7.7 Induction Mode...................................................................................................................... 47
7.8 Direct Connection Mode ........................................................................................................ 47
7.9 Clamp Mode .......................................................................................................................... 47
8. Loc-1Tx Transmitter ............................................................................................................ 48
8.1 Pushbutton ............................................................................................................................ 48
8.2 External Connectors .............................................................................................................. 48
8.3 Replacing Alkaline Batteries ................................................................................................. 48
8.4 Rechargeable Batteries ......................................................................................................... 48
8.5 Loc-1Tx Transmitter Operation ............................................................................................. 48
9. Using the vLocPro2 ............................................................................................................ 49
9.1 Using the Receiver ................................................................................................................ 49
9.1.1 Line Locating ..................................................................................................................... 49
9.1.2 Depth & Current Measurement .......................................................................................... 49
9.1.3 Sonde Location .................................................................................................................. 50
9.1.4 Using the Compass Feature to Locate Sondes ................................................................. 50
9.2 Passive or Active Location .................................................................................................... 52
9.2.1 Passive Locating ................................................................................................................ 52
9.2.2 Active Locating .................................................................................................................. 52
9.3 Applying the Transmitter’s Signal .......................................................................................... 53
9.3.1 Direct Connection .............................................................................................................. 53
9.3.2 Clamp (Coupler) ................................................................................................................ 53
9.3.3 Induction ............................................................................................................................ 54
9.3.4 Searching (sweeping) an Area ........................................................................................... 55
9.3.5 Tracing a Buried Line ......................................................................................................... 55
9.3.6 Pinpointing & Confirming the Buried Line .......................................................................... 55
9.3.7 Distorted Fields .................................................................................................................. 56
9.3.8 Measuring Depth and Current ............................................................................................ 57
9.3.9 Signal Direction Precision Identification ............................................................................. 58
9.4 Using the Accessories ........................................................................................................... 60
9.4.1 Using the LPC Separation Filter ........................................................................................ 60
9.4.2 Using the A-frame in Fault Finding .................................................................................... 61
9.4.3 Using the Remote Antenna USB ....................................................................................... 63
10. Accessories & Options ........................................................................................................ 66
10.1 A-frame (Optional) ................................................................................................................. 66
10.2 Remote Antenna (Optional) .................................................................................................. 66
10.3 Loc-10Tx Vehicle Power Lead (Optional) .............................................................................. 66
10.4 Loc-10Tx Outdoor Power Supply (Optional) ......................................................................... 66
10.5 LPC Separation Filter (Optional) ........................................................................................... 66
10.6 Receiver Vehicle Charging Lead (Optional) .......................................................................... 66
10.7 Sonde (Optional) ................................................................................................................... 67
10.8 Clamp (Optional) ................................................................................................................... 67
10.9 Lithium-ion Rechargeable Battery Pack (Standard) .............................................................. 68
10.10 Receiver Battery Charger (Standard) .................................................................................... 68
10.11 USB Cable (Standard) .......................................................................................................... 68
10.12 Alkaline Battery Holder (Standard) ........................................................................................ 68
10.13 Ground Stake (Standard) ...................................................................................................... 68
10.14 Direct Connection Lead (Standard) ....................................................................................... 68
10.15 Loc-1Tx Alkaline Battery Tray (Standard) ............................................................................. 68
10.16 Ground Spool (Optional) ....................................................................................................... 69
10.17 Banana Plugs Adapter (Optional) .......................................................................................... 69
10.18 Loc-5Tx Battery Pack (NiMH)................................................................................................ 69
10.19 Loc-5Tx Alkaline Battery Tray ............................................................................................... 69
10.20 Loc-5Tx/10Tx Charger .......................................................................................................... 69
10.21 Loc-10Tx Rechargeable Battery Tray ................................................................................... 69
10.22 Loc-10Tx Alkaline Battery Tray ............................................................................................. 69
11. Glossary.............................................................................................................................. 70
1 General Safety & Care Information
Page 1 of 72
1. General Safety & Care Information
1.1 Who Can Use This Equipment
This equipment must only be used by people suitably trained in the use of pipe and cable locators.
1.2 Work-site Safety
Use your companies, or other applicable safety code and rules when using this equipment.
Unless having the required authorization, license and appropriate training – do NOT make
connections to any pipe, cable or conductor.
The equipment should not come in contact with corrosive or hazardous chemicals, or gases, dust.
Do NOT directly connect this equipment to cables or pipes that have a potential difference to ground
of greater than 35V AC.
1.3 Equipment Safety
Do NOT open the enclosures (housings) of either the transmitter or receiver.
Place the ground stake firmly in the ground before connecting the cable from the transmitter.
Do NOT hold any uninsulated portion of the connection leads & clips when the transmitter is switched
on.
1.4 Batteries and Environmental Safety
Vivax-Metrotech products use four types of batteries:
Alkaline batteries
Ni-MH (Nickel Metal Hydride) batteries – rechargeable
Lithium-ion batteries – rechargeable
Lithium metal batteries – (small non rechargeable button cells for “clock” applications)
1.4.1 Alkaline Batteries (Non Rechargeable)
When replacing the alkaline batteries – use only the size and type specified – do NOT mix battery types (rechargeable and alkaline).
Do NOT mix partially discharged and fully charged cells in the same battery pack – do NOT mix old with new.
Never attempt to charge alkaline batteries.
1.4.2 Nickel Metal Hydride Batteries (Rechargeable)
When using rechargeable batteries, use only the correct charging device supplied or specified by the manufacturer. The battery pack or the battery charger will contain circuitry to manage the charging process – other chargers (even if they have the same connector, polarity, voltage & current rating will not have the same control circuitry and can cause damage to the product, overheating, and in extreme cases fire or harm to the individual.
Do NOT assume that if the plug fits it is the correct charger – a charger with the correct part number MUST be used – just because it is a Vivax-Metrotech charger and the plug fits does NOT mean it is the correct charger.
Before using for the first time, charge rechargeable batteries for 6 hours. If at any time the rechargeable batteries do NOT last as long as anticipated – discharge fully and then charge for 6 hours.
Care should be taken when charging batteries – NEVER repeatedly recharge batteries (or turn power off & on) without using the instrument. If used with an inverter in a vehicle – charge the product then unplug the charger and do NOT charge again until the rechargeable batteries have been used for at least ten minutes. Failure to do this could result in the overcharging of the battery which will shorten the life of the battery, and could in some circumstances cause overheating or fire.
If ever the product becomes hot during the charging process IMMEDIATELY unplug the charger and use the rechargeable batteries for at least 10 minutes before recharging. If this reoccurs the next time the unit is charged – return immediately to Vivax-Metrotech for repair.
Do NOT charge batteries for prolonged periods of time without using the locator for at least 10 mins.
1 General Safety & Care Information
Page 2 of 72
Charging for prolonged period of time could overcharge the battery, reduce the battery life and in extreme circumstances cause damage to the locator and fire.
1.4.3 Lithium-Ion Batteries (Rechargeable)
Lithium-ion Batteries – some products use Lithium-ion batteries – the requirements for marking and transportation are still developing. Please contact Vivax-Metrotech before shipping products containing Lithium-ion batteries or Lithium-ion battery packs on their own for any “special instructions”.
1.4.4 Lithium Metal Batteries (Non Rechargeable)
Commonly known as “button cells” these are small – non rechargeable batteries used to power internal “clocks” within some units (similar to computers). Generally they have a life of 3-5 years.
Under no circumstances should any attempt be made to charge these batteries.
Dispose of to your company’s work practice/environmental standards, the prevailing laws, or
recognized best practice. Always dispose of batteries responsibly.
1.4.5 General Rules Regarding Disposal of Batteries
NEVER disassemble a battery, or battery pack.
Never dispose of in a fire or water.
Dispose of batteries in accordance with your Company’s work practice/environmental standards, the
prevailing laws, or recognized best practice. Always dispose of batteries responsibly.
1.4.6 Transportation of Lithium-ion and Lithium Metal Batteries
The Lithium-ion and Lithium metal batteries used in Vivax-Metrotech products meet the required safety standards and include the designated protection circuitry.
Recent regulation changes require that when batteries with Lithium-ion and Lithium metal batteries are transported the packaging MUST included specified warning labels. Please contact Vivax-
Metrotech Customer Service (USA 1-800-446-3392, International +1-408-734-1400 (USA Pacific Time Zone)) for more details.
Regulations have also changed regarding the shipping of spare battery packs (battery packs that are not inside a product). There are limitations on the weight of the package, and the packaging must be marked with the appropriate warning labels. Please contact Vivax-Metrotech Customer Service (USA 1-800-446-3392, International +1-408-734-1400 (USA Pacific Time Zone)) for more details.
Vivax-Metrotech vLoc Series 2 products using Lithium-ion battery are classified as "not restricted" they can be shipped normally by road/rail/sea & air (passenger & freight aircraft) without restrictions.
IMPORTANT Remember – Batteries contain dangerous chemicals – They can be affected by many things such as water ingress or heat – In some circumstances they can explode. They also can cause electric shocks!
1 General Safety & Care Information
Page 3 of 72
1.5 Care of Equipment
Use equipment only as directed in this User Handbook.
Do NOT immerse any part of this equipment in water.
Store in a dry place.
Keep equipment in the case provided when not in use.
If left for prolonged period of time – remove alkaline batteries.
Keep unit clean and free of dust and dirt.
Protect against excessive heat.
1.6 Care When Interpreting the Information Provided by the Locator
Like all locators – this instrument is locating, and providing depth and current readings based on electromagnetic signals that radiate from the buried cable or pipe. In most cases these signals will enable the locator to pinpoint both position depth and current correctly.
BEWARE – in some cases other factors will distort electromagnetic fields radiating from cable or pipe being located, resulting in incorrect information.
Always locate responsibly, and use information learned during your training to interpret the information provided by the locator.
Do NOT provide information regarding depth of cable or pipe to anyone unless authorized to do so by your company.
REMEMBER that depth measurements are to the center of the electromagnetic field or pipe – In the case of pipes this may be significantly deeper than the top of the pipe.
1.7 American & Canadian Safety Notices
USA
This transmitter and receiver comply with the general conditions of operation, pursuant to part 15 of the FCC Rules.
CFR 47 Part 2
CFR 47 Part 15
Changes or modifications not expressly approved by the manufacturer could void the user’s authority
to operate the products.
CANADA
Equipment is for use by trained operators only, and not for general household or consumer use.
Operation is subject to the following two conditions: (1) this device may not cause interference, and
(2) this device must accept any interference that may cause undesired operation of the device.
EUROPE
Vivax-Metrotech confirms that the location system is compliant with relevant provision of European directive 1999/5/EC.
EN 55011
EN 61000-4-2: A1 & A2
EN 61000-4-3
EN 61000-4-8: A1
ETSI EN 300 330-2
ETSI EN 301 489-1
ETSI EN 301 489-3
2 Service & Support
Page 4 of 72
2. Service & Support
2.1 Serial Number and Software Revision Number
Always quote your receiver and transmitter model number, serial number and software revision number when requesting product support. They can be found as follows: (for reference only)
1 Model & Serial Number
NOTE The transmitter Model & Serial Number can be found at the bottom of the
transmitter and also inside the transmitter between the battery tray and the main module of transmitter.
Software Revision Number: On both receiver and transmitter the software revision number is displayed on the LCD during the start up sequence or can be found in the “About” section of the user menu.
2 Service & Support
Page 5 of 72
2.2 Distributors and Service Centers Closest to You:
United State of America Europe Vivax-Metrotech Corporation SebaKMT
3251 Olcott Street, Seba Dynatronic Santa Clara, CA 95054, USA Mess-und Ortungstechnik GmbH Website : www.vivax-metrotech.com Dr.-Herbert-Iann-Str. 6, 96148 Baunach, Germany Sales & Sales Support: T/Free : +1-800-446-3392 Tel : +49-9544-680 Tel : +1-408-734-1400 Fax : +49-9544-2273 Fax : +1-408-734-1415 Website : www.sebakmt.com Email : sales@vxmt.com Email : service@sebakmt.com
Application Support:
Australasia
T/Free : +1-800-624-6210
SebaKMT AUS
Tel : +1-408-454-7159 Unit 1, 176 South Creek Road, Fax : +1-408-743-5597 Cromer NSW 2009, Australia Email : applications@vxmt.com
Tel : +61-2-9972-9244 Service & Repairs: Fax : +61-2-9972-9433 T/Free : +1-800-638-7682 Website : www.sebakmtaus.com Tel : +1-408-962-9990 Email : sales@sebakmtaus.com Fax : +1-408-734-1799 service@sebakmtaus.com Email : service@vxmt.com
China All Other Department:
Leidi Utility Supply (Shanghai) Ltd.
T/Free : +1-877-330-1647 No. 780, Tianshan Rd, Tel : +1-408-734-3880 Shanghai, China 200051 Fax : +1-408-962-9993
Tel : +86-21-5235-3001
Canada
4008-206-719 Vivax Canada Inc.
Fax : +86-21-5235-8365 400 Esna Park Drive, Website : www.leidi.com Unit 17, Markham, Email : info@leidi.cn Ontario, L3R 3K2, Canada
Tel : +1-289-846-3010 Fax : +1-905-752-0214 Website : www.vivax-metrotech.com Email : CanadianSales@vxmt.com
3 vLocPro2 Receiver
Page 6 of 72
3. vLocPro2 Receiver
3.1 vLocPro2 Receiver
The vLocPro2 is a Precision Location System designed to meet the needs of Utility Companies and their contractors. The following describes the features and use of the receiver:
1 Optional Bluetooth Module 6 Charging Socket
2 Pushbutton & Display 7 Mini USB Port Data Transfer and Software
Upgrade
3 Carbon Fiber Reinforced Antenna Assembly 8 Accessories Port
4 Accessory & Charging Sockets 9 Model# & Serial#
5 USB Memory Stick Data Transfer, active on
some models
10 AA Battery Pack/Rechargeable Battery Pack
3 vLocPro2 Receiver
3.2
Charging the Receiver Batteries
The vLoc series 2
can be used with either alkaline batteries or it can be supplied with an interchangeable
rechargeable battery pack.
When alkaline battery is used, Icon A will appear on the screen. When the
Icon B will be displayed.
In both cases, the number of bars illuminated within the bat
remaining.
Rechargeable batteries are supplied with a mains charger. This is specific to the batteries, avoid the use of
other manufacturers’ chargers as these may damage the battery pack and may result in overheat
battery pack.
To charge the rechargeable batteries
as charging is done in
side the receiver
Connect the charger to the charging socket of the receiver.
LED indicator on the charger will illuminate red until the batteries are fully charged at which time the LED will
change to green.
W
ARNING
Rechargeable batteries are supplied with a mains or 12V
speci
fic to the batteries. Only use the charger that is appropriate for the batteries
in the product. If in doubt
the appropriate charger could result in damage to the battery pack, locator and
in extreme c
Avoid charging the unit in extreme temperature conditions. (i.e. below 0ºC and
above 45ºC)
Although V
features always immediately discontinue use of the charger and battery
the battery pack becomes excessively warm. Return both to where they were
purchased for investigation.
Always ensure batteries have at least a partial charge if storing for long periods
without use.
Dispose of all batteries in accordance with you
Federal/State and local regulations.
Never dismantle batteries, put them in fire, or get wet.
rechargeable battery pack is used
tery icon indicates the amount of charge
,
first make sure the pack is inserted in the receiver battery compartment
.
Connect charger t
o the mains and switch on. The
DC
charger. These are
, call Vivax-Metrotech
Customer Service. Failure to use
ases cause fire.
ivax-Metrotech
batteries include all the required safety related
r company procedures and
Icon A Icon B
Page 7 of 72
,
ing of the
pack if
3 vLocPro2 Receiver
Page 8 of 72
3.3 vLocPro2 Receiver Main Display
The vLocPro2 has several display options – the display shown below is representative of the types of display and icons used.
1 Digital Display of Signal Response 10 Frequency Select
2 Loudspeaker Status 11 Gain Control (reduce gain)
3 Bluetooth and GPS Signal Quality 12 On/Off Control
4 Alkaline/Rechargeable Battery Status 13 Compass Line Direction Indicator
5 Peak Signal Indication 14 Left vs Right Indication
6 Frequency 15 db Gain Setting
7 Location Mode Select 16 Analogue Display of Signal Response
8 Gain Control (increase gain) 17 Continuous Depth/Current
9 Information Depth/Current Measurement 18 Location Mode
(Peak, Null, Sonde, Broad, Peak Arrows)
Note: Bluetooth function is available in vLoc receivers with Bluetooth module only.
3 vLocPro2 Receiver
Page 9 of 72
3.4 vLocPro2 Receiver Screen Shots
vLocPro2 Receiver Menus (Actual menu may differ)
Main Display
Setup Menu – Frequencies
Depth & Current Measurement Frequencies selected here are the only ones displayed in the frequency box on the Main Display
Main Menu
The vLocPro2 is a Precision Location System designed to meet the needs of Utility Companies and their contractors. The following describes the features and use of the receiver.
3 vLocPro2 Receiver
Page 10 of 72
3.5 Locating Mode (Response)
The vLocPro2 receiver has four antennas, and these can be toggled through different configurations (modes) to provide different responses to the signals radiating from the buried pipes and cables. The modes are:
3.5.1 Peak Response Mode
This uses the two horizontal antennas and provides a “Peak” or maximum signal response over the center of the radiated signal from the buried line. The compass line direction indicator shows the direction of the cable (available in Active modes). The color of the compass changed from clear to blue when the receiver is in line with the buried line.
This is the most accurate of the locating modes as both antennas are used to provide a clearly identifiable “Peak”. In the “Peak” mode, a “Peak” signal indicator helps to clarify the position of the “Peak”. This shows the last “Peak” located for a few seconds, enabling the user to return to that position quickly.
3.5.2 Broad Peak Mode
This uses a single horizontal antenna and provides a “Peak” or maximum signal response over the center of the radiated signal from the buried line. The compass line direction indicator shows the direction of the cable (available in Active modes). The color of the compass changed from clear to blue when the receiver is in line with the buried line.
This is less accurate than the twin horizontal antenna “Peak” mode – but is useful if the buried line is particularly deep. For pinpointing the line, the “Peak” mode should be used.
3.5.3 Null Mode
This uses vertical antennas and provides a minimum or “Null” response over the center of the radiated signal from the buried line. The compass line direction indicator shows the direction of the cable (available in Active modes). The color of the compass changed from clear to blue when the receiver is in line with the buried line.
Some users prefer the null response; it works well in uncongested areas, but is more prone to inaccuracies due to distortion of the radiated signal in congested areas.
Left/right indication arrows are also displayed when in “Null” mode. The arrows indicate the direction to move the receiver to locate the position of the buried line.
Pushbutton
Icon
Compass Line
Direction Indicator
Pushbutton
Icon
Compass Line
Direction Indicator
Pushbutton
Icon
Compass Line
Direction Indicator
3 vLocPro2 Receiver
Page 11 of 72
3.5.4 Peak with Arrows Response Mode
This uses the two horizontal antennas and provides a “Peak” or maximum signal response over the center of the radiated signal from the buried line. The compass line direction indicator shows the direction of the cable (available in Active modes). The color of the compass changed from clear to blue when the receiver is in line with the buried line.
This is the most accurate of the locating modes as both antennas are used to provide a clearly identifiable “Peak”. In the “Peak” mode, a “Peak” signal indicator helps to clarify the position of the “Peak”. This shows the last “Peak” located for a few seconds, enabling the user to return to that position quickly.
Left/Right arrows also guide the user to the line. However, it should be noted that the arrows use the Null antenna to resolve which arrows are activated. The null antenna is not as accurate in distorted fields as the peak antennas. Therefore, when pinpointing, use the peak bargraph to determine the position of the line.
Note If the arrows indicated a different position for the cable than the peak bargraph position, this indicates the possibility of a distorted field. Check by taking a depth reading on the ground and then lift the cable locator a known distance such as 0.5m (3ft). If the depth does not increase by this amount it confirms a distorted field and the data should be treated with caution.
Pushbutton
Icon
Compass Line
Direction Indicator
3 vLocPro2 Receiver
Page 12 of 72
3.5.5 Sonde Mode
Sonde mode uses the antennas in a “Peak” configuration. An ICON on the display indicates if the receiver is in Sonde mode.
A Sonde is a small transmitting coil that is powered by its own internal battery, or by an external transmitter.
Due to its construction, a Sonde gives a different “Peak” pattern – when locating along the direction of the Sonde – instead of the usual single “Peak”, the Sonde provides three distinct peaks – a small “Peak” – a large “Peak” – a small “Peak”. The Sonde is located under the center of the large “Peak” when located across the direction of the Sonde and it gives the conventional peak response. Note that the Compass Line Indicator points across the line of the Sonde when directly over it and the color of the compass change from clear to blue.
The vLocPro2 receiver must be used in a different orientation when locating a Sonde – due to the way the signal from the Sonde radiates. With the front of the receiver pointing across suspected direction of the Sonde – pinpoint forward and backward (across the Sonde) and then move along the line of the Sonde until the maximum peak is located (in other words rotate the receiver 90 degrees from the orientation normally used when locating pipes and cables).
A Sonde is typically used for locating non metallic pipes or ducts, and the camera end of a sewer inspection camera. Low frequency versions (512 Hz/640 Hz) can transmit through some metallic pipes such as cast iron pipes – which are why they are frequently used with sewer inspection cameras.
For using the compass feature to locate Sondes, please refer to 9.1.3.
3.6 Audio
The visual display is also accompanied by an audio response. The output level (volume) of this response is set by entering the “Setup Menu”. Press and hold “i” pushbutton for 2 seconds to enter setup menu. The setup display defaults to volume. Use the “M” pushbutton to toggle through the available options (Off – Low – Med – High). Press the “i” pushbutton again to exit the setup menu. As the loudspeaker uses a significant amount of power, using lower volume can make the battery life of the receiver last longer.
3.7 Sensitivity Control
In manual modes, “+” and “-” pushbuttons are provided to increase or reduce the sensitivity of the receiver. If the bar graph moves towards the minimum or maximum a single touch of the opposite pushbutton returns it to approximately 50% deflection. Holding down or repeated pushing of the “+” or “-” pushbuttons increments/decrements the gain.
Pushbutton
Icon
Compass Line
Direction Indicator
Pushbutton Pushbutton
3 vLocPro2 Receiver
Page 13 of 72
3.8 Frequency Selection
The vLocPro2 receiver is capable of locating a large number of frequencies or frequency combinations. A list of these frequencies can be accessed using the setup menu. Most of these frequencies listed – you will never use – the setup menu allows you to select the frequencies you wish to use regularly. The frequency select pushbutton on the main receiver pad is used to toggle through the frequencies defined using the setup menu. The operating frequency will be shown at the lower right side of the display. You can change this selection at any time using the setup menu.
The initial frequencies set at the time the unit is supplied are “Power”, “Radio” and the frequencies used by the transmitter purchased. See the transmitter section for suggestions of which frequency is best suited to specific applications.
To select the frequencies you wish to use regularly – enter the setup menu by pressing and holding the “i” pushbutton for 2 seconds. Use the “+” and “-” to select the word “Frequency” – then press the “M” pushbutton to display the list of available frequencies.
The “+” and “-” pushbuttons are used to navigate the list of frequencies. To add a frequency to the “Frequently used list” press the “M” pushbutton and
a dot will appear in the circle alongside the frequency. To deselect a frequency press the “M” pushbutton and the dot will disappear. Once your selection is completed press “i” pushbutton once to return to the setup menu, and again to exit the setup menu.
Pushbutton
3 vLocPro2 Receiver
Page 14 of 72
3.9 Information Pushbutton (Depth & Current)
Pressing the “i” (information) pushbutton will display the depth to the center of the radiated signal and a measurement of the current (press the pushbutton briefly – remember if you press and hold – you enter the setup menu. If you do enter the setup menu – press the “i” pushbutton again to return to the locating screen – then try again).
The display shown above shows Long/Lat positional informaiton. This is only displayed when the equipment is paired with a valid GPS system.
IMPORTANT When locating a cable or pipe (“Line”) – the instrument should be in “Peak” mode and the depth and current measurements should only be taken with the bottom of the receiver standing on the ground and directly in line with the target line.
IMPORTANT When locating a Sonde – set the mode to Sonde - then the instrument will automatically be in “Peak” configuration. Depth measurements should only be taken with the bottom of the receiver standing on the ground and at ninety
degrees to the Sonde.
The accuracy of depth and current readings depends on the quality of the radiated signal being located. If the signal is symmetrical, the depth reading will be accurate to within 5% of the actual depth. If the signal is distorted, depth readings will be less accurate. When taking depth measurement, always hold the receiver at 900 to the ground.
3.10 Information Pushbutton (Setup Menu)
As described previously, a second function performed by the “i” is to access the SETUP menu. Press and hold the “i” pushbutton for two seconds to display the SETUP menu. Use the “+”, “-” to navigate through the various options and use the “M” pushbutton to select. To exit the setup menu, press the “i” pushbutton.
The setup menu allows the user to configure their personal preference, this menu can be accessed and changed at any time.
Pushbutton
Pushbutton
4 vLocML2 Receiver
Page 15 of 72
4. vLocML2 Receiver
4.1 Introduction
The vLocML2 is a variant of the vLoc locator. It can be identified by the loop antenna attached to the base of the locator tube. The purpose of the loop antenna is to energize passive markers buried above non metallic services or points of interest.
Markers can be supplied in many sizes or shapes but the most commonly used marker is the ball marker. This has a range of over 1.5m. Markers operate over a range of frequencies. Different frequency markers are used to identify different services and are identified by color. The industry standard colors are listed below:
Telecom (Orange)
Cable paths, buried splices, buried service drops, load coils, conduit stubs, fiber optic facilities, all types of splices, bends, depth changes, manhole covers, road crossings Frequency: 101.4 kHz
Power (Red)
Cable paths, service drops, conduit stubs, road crossings, all types of splices, buried transformers, service loops, street lighting, bends, man hole covers, distribution loops Frequency: 169.8 kHz
CATV (Black & Red)
Cable paths, fiber optic facilities, buried service drops, road crossings, buried splices, bends Frequency: 77 kHz
Non Potable Water (Purple)
Reclaimed water, private campuses, valve boxes, road crossings, path making, buried valves, tees, meter boxes, main stubs, service stubs
Frequency: 66.35 kHz
Water (Blue)
Pipeline paths, service stubs, PVC pipeline, all types of valves, road crossings, tees, clean-outs, casing ends Frequency: 145.7 kHz
Sewage (Green)
Valves, all types of fittings, clean outs, service stubs, laterals, path marking of non-metallic facility Frequency: 121.6 kHz
Gas (Yellow)
Pipeline paths, main stubs, service stubs, tees, road crossings, all types of valves, meter boxes, stopping fittings, depth changes, transition fittings, squeeze points, pressure control fittings, electro fusion couplings, all types of fittings and joints Frequency: 83 kHz
EDF Power (Grey Disk)
Gas and Electric Installations (EDF only) Frequency: 40 kHz
Seba Energy (Red & Blue)
Cable paths, service drops, conduit stubs, road crossings, all types of splices, buried transformers, service loops, street lighting, bends, man hole covers, distribution loops
Frequency: 134 kHz
4 vLocML2 Receiver
Page 16 of 72
4.2 Operating the vLocML2
The vLocML2 can be operated in three configurations:
Standard cable locator
Dedicated marker locator
Dual cable locator and marker locator
4.2.1 Switching Between Configuration
There are two ways of switching between configurations:
Using the user menu
Using the “M” pushbutton
To use the user menu, press and hold the “i” pushbutton. Use the “+” pushbutton to scroll down to “Marker Locator”. Press the enter key to scroll through the options. Exit the user menu by pressing the “i” pushbutton.
It is possible to hop between configurations using the enter key. To do this press and hold the enter key until the desired configuration is reached.
4.2.2 Standard
In this configuration the unit operates as a standard vLoc cable and pipe locator. For the operation of this see the standard vLoc user handbook sections.
4.2.3 Dedicated
In this configuration the unit is dedicated to detecting markers. The screen of the vLocML2 will look similar to the picture below
Note that the ball icon is illuminated indicating that the dedicated configuration is selected. If the line icon
is illuminated with the ball icon, this indicates that the Dual configuration is activated.
It is also possible to take depth to marker estimations in the dedicated mode. (Section 4.2.4)
Use the “f” pushbutton to select the marker type that is to be located.
1 Signal strength from Marker used for
pinpointing position 2 Marker detection ball (Not adjustable) 3 Marker icon indicating marker detection
active 4 Marker type, numeric 5 Marker type, graphic
4 vLocML2 Receiver
Page 17 of 72
Sweep the area of where the marker is to be located. Use a slow, deliberate arm sweeping motion slowly moving forward making sure no area is missed.
When the locator is within range of the marker there will be a sound from the speaker and also the icon in the centre of the display (2) will start to fill up.
Move the locator forward and back, left and right, until the largest signal is detected. Note the bar graph (1) will also respond. Use the “+” and “-” pushbuttons to keep the signal on scale. The bar graph should be used to pinpoint the position of the marker.
4 vLocML2 Receiver
Page 18 of 72
4.2.4 Marker Depth Estimation in Dedicated Mode
It is only possible to undertake depth measurement of a marker, when in the dedicated mode.
Procedure:
1. Switch to Dedicated mode. (ie. Ensure only marker icon is displayed in bottom left hand corner of the display)
2. Pin point the position of the marker as previously described.
3. Position the locator on the ground directly over the marker.
4. Press the “I” button. The display will change to something similar as shown below.
5. Raise the locator 6” (15cm) and again press the “I” button. The depth estimation will be displayed similar as shown below:
TIP The more accurate the locator is raised by 6” (15cm) the more accurate will be
the measurement.
In the event that the marker is less than 30cm deep the following screen will be displayed:
If the following display is shown, this indicates that the marker is either out of range or there is an invalid signal.
4 vLocML2 Receiver
Page 19 of 72
4.2.5 Dual Configuration
In this configuration the unit can be used to trace an energized cable or pipe whilst simultaneously looking for the presence of markers. For example if a cable has markers indicating the position of splices or T joints, the cable can be traced and when a marker is approached the unit will respond indicating the position of the marker.
Enter the dual configuration as previously described. Select the marker type to be detected by pressing and holding the “i” pushbutton to enter the user menu. Use the “+” and “-” pushbuttons to scroll down to “Marker Type”. Press the enter key and scroll down to the desired marker. Use the enter pushbutton to select the marker. Exit the user menu by pressing the “i” pushbutton twice.
The locator screen will look similar to the picture below.
Note that both icons are now illuminated indicating that dual configuration is activated. Energize the cable with 512 Hz, 640 Hz or 8.192 kHz as instructed in the vLoc user handbook. Select the antenna configuration by using the “M” pushbutton. Note that the left/right arrows indicate the cable position and NOT the marker position. Use the “f” pushbutton to match the transmitter frequency (only 512Hz, 640Hz or 8.19 kHz frequencies are available in dual configuration). Use the locator to identify the position of cable or pipe. Trace the line using the same technique as a standard vLoc locator. The bar graph indicates the signal strength from the cable. Note that in the dual configuration mode the “+” and “-” pushbuttons alter the sensitivity of the cable locate bar graph. It is not necessary to alter the sensitivity to the marker locate function. The sound is from the line position. In dual configuration the marker has no sound associated with it. As a marker is approached the marker locate icon will start to fill up. Move the locator forward and back, left and right to obtain the largest signal. If pinpointing is required select dedicated configuration and use the bar graph to pinpoint the exact position.
1 Bar graph showing signal strength from
energized line 2 Marker detection ball (Not adjustable) 3 Line icon indicating line locate is active 4 Marker icon indicating marker detection
active 5 Line locate frequency 6 Marker type, numeric 7 Marker type, graphic
5 Data Logging
5.
Data Logging
The v
Loc2 has an internal memory that can be used to store location data. It can store in excess of 1000
records.
To store a record first locate a point of interest. Hold the vLoc statio
pushbutton. When in the
depth and current
number indicates the number of records stored.
If the GPS function is enabled the GPS coordinates will also be
more information on Data logging and GPS see section
5.1 Bluetooth
As an optional extra the
vLocPro2
accessory. The Bluetooth
option
5.1.1 Fitting the
Bluetooth
1.
Ensure the unit is switched off.
2.
Use a small cross head screw driver to remove the two screws r
found at the back of the
3.
Remove the cover by sliding it away from the handle.
4. Take the Bluetooth
module and carefully slide it into the position the cover was occupying.
5.
Replace the two cross head screws.
6.
Switch on the unit and after a few se
is fitted.
7.
If a red line is shown through the icon, this indicates that the
enable is located in the user menu which is accessed using a long pre
8. The Bluetooth
can communicate with external devices that are also
Bluetooth
enabled GPS devices but Vivax
requiring mapping to accuracie
instance submeter accuracy, the customer should contact a GPS supplier of their choice. However, as a
recommendation, one such device that delivers submeter accuracy is the Trimble ProX
nary over the target and press the
screen, press the “+” push
button to save the data.
displayed and attached to any saved file. For
5.2.5.4.
and vLocML2 receivers can be fitted with a
Bluetooth
can be retrofitted and can be ordered at a later date if preferred.
Module
etaining the
Bluetooth
handle near the battery compartment.
conds a grey, Bluetooth
icon should appear showing that the module
Bluetooth
module is not enabled.
ss of the “i
” button.
Bluetooth
enabled. There are many
-
Metrotech offer the Holux GPS as a suitable solution for those
s better than 5m. For those requiring accuracies better than this, for
Page 20 of 72
“i”
The “Log”
communications
cover. This is
Bluetooth
T.
5 Data Logging
5.2
Holux GPS Device O
The Holux M-1200E
is a simple GPS device with integral rechargeable batteries and
communications. It can either be mounted in the purpose designed holder from Vivax
positioned anywhere within a f
peak of a baseball cap ensures clear view of the sky and satellites.
The best accuracy that can be expected from this device is better than 2.2m. However, this depends on
satelli
te and DPGS satellite availability. It is compatible with EGNOS and WAAS SBAS differential satellite
correction systems.
Ensure the battery is charged by either using the cigarette charger lead supplied or attaching it to a USB
interface using a standard
USB to mini USB lead.
To switch on the M-1200E
position the slider switch, located on the side of the device, to the on position. The
Bluetooth
icon will flash rapidly (approx every half second). This indicates that it is searching for a device to
pair wi
th. When the Holux is paired with a device the flashing will change to a slower rate.
The GPS icon will be continuously illuminated indicating that GPS lock is not achieved. When the GPS icon
starts to flash GPS lock is achieved.
TIP
For best results a
commencing a survey.
5.2.1
Pairing with the
1.
Switch on the M1200 and ensure it is within a couple of meters of the
2.
Pairing the M1200 with the
and hold the “i” push
button.
3. Press the “+”
button to scroll to
begin to search for available devices. At the end of the search
include “HOLUX_M-
1200 Use the
pushbutton.
4. The vLocPro2
will automatically return to the locate screen. Within 10 seconds the
change from
grey to blue. This indicates that pairing is successful.
TIP
When not using the
by entering the user menu and deselecting
battery life and prevent interferen
Radio mode.
When the
the
Bluetooth
5. Next to the Bluetooth
icon is the red GPS signal strength bar graph. This
signal is detected.
6.
The bar graph has 4 levels. For best results
commencing the survey. The accuracy will improve with more bars illuminated.
verview
-
ew meters from the vLocPro2
. For instance using “Velcro to attach it to the
llow the GPS indicator to flash at least 15 minutes before
vLocPro2/vLocML2 Receivers
receiver.
receiver is achieved through the setup
menu. To enter the
Bluetooth Pairing” and press the “M” push
button. The
, a list
will be displayed which should
“+” and “–” pushbuttons
to highlight this device and press the
Bluetooth function switch off the
Bluetooth
Bluetooth
Search. This will save
ce from the Bluetooth
search activity, in the
Bluetooth
search function is deactivated a red line will appear through
icon in the locate screen.
will not appear until a valid GPS
,
allow a few minutes after the bar graph has started before
Page 21 of 72
Bluetooth
Metrotech or can be
setup menu press
vLocPro2 will
M”
Bluetooth icon will
search function
5 Data Logging
Page 22 of 72
5.2.2 Gathering Data in Active Modes
Switch on the Holux and ensure pairing as indicated above. (Bluetooth icon should be blue) Wait for a valid GPS signal as indicated by the red bar graph next to the Bluetooth icon.
TIP It is a good idea to ensure the datalog is clear before commencing. To do this
press the “i" button. Whilst the depth screen is displayed press and hold the “-” button. The message:
“Are you sure you want to delete all this datalog. Press + key to Delete” Pressing the “+” key will clear the datalog.
5.2.3 Gathering Data in Power and Radio (Passive) Modes
This is done in the same way as in the active modes except that it is not possible to enter the measure mode unless a valid GPS signal is received from the Holux GPS.
Depth and current are not available in the passive modes but all other data can be saved to the datalog.
Locate the cable as described in the vLocPro2 user handbook. Momentarily press the “i" button. A screen similar to the below will be shown:
To save a record press the + button whilst in this screen.
5.2.4 Transferring Data from the Locator to a Computer
To transfer data it is necessary to use the vLocPro2 Configurator Tool. This is a simple program that can be downloaded from the Vivax-Metrotech web site at www.vivax-meterotech.com. The file can be found under the Support/Download Library/Others Download.
TIP To view Google files it is first necessary to install the Google earth application to your computer. This is a free application which can be found at http://www.google.com/earth/download/ge/agree.html
1 GPS Coordinates
2 Number of records stored
5 Data Logging
5.3
Trimble ProXT/XH
For those wishing to work with accuracies better than 1 meter, the Trimble ProXT/XH provides a simple and
cost effective solution.
The ProXT operates in a very similar way to the Holux in that it has two LEDs
indicating that there is
Bluetooth
the Holux described above.
5.3.1
Trimble ProXT/XH
The Pr
oXT can also be configured for
to operate with the vLocPro2
Install to your computer t
he Trimble GPS Controller software. This is a free application and can be found at
http://www.trimble.com/pathfinderproxt_ts.asp?Nav=Collection
Connect the Trimble ProXT
RS232 lead supplied.
Launch the application and switch on the GPS. When connection is achieved a little satellite icon will appear
in the middle of the top bar.
1. From “Skyplot”
select “Setup
2.
Now select “GPS Settings
3.
Select COM1 and set the parameters as below and then press OK.
lock and another for GPS lock. Bluetooth
pairing is one in the same way as
Data gathering is exactly the same as wit
h the Holux described above.
Setting up Procedure
different applications so the first time it is used it should be configured
/vLocML2 receiver.
-32840
to your computer either by setting up a Bluetooth
connection or by using the
.
.
Page 23 of 72
5 Data Logging
Page 24 of 72
4. Now select the spanner on the “NMEA Output” line.
5. Set the following perameters:
6. Press OK to save parameters to the GPS.
7. These parameters are suggested values. Experienced users may decide to alter them to suit the particular requirements of an application.
8. Pairing with the vLoc receiver is similar to the Holux described previously. Data gathering is also similar to the Holux procedure.
5.3.2 Transferring Data from the vLoc2 to a Computer
To transfer data from the vLoc series 2 receiver to a computer requires the use of a simple free of charge software package MyLocator2. It can be downloaded from the Vivax-Metrotech web site www.vivax- metrotech.com.
5 Data Logging
Page 25 of 72
5.4 MyLocator2
MyLocator2.configuration tool is a software package that enables the operator to configure the vLoc series 2 of locators. The software is compatible with Window XP, Vista and 7. To install, use the link on the Vivax­metrotech web site and follow the installation instructions. A MyLocator2 shortcut icon will appear on your desktop. MyLocator2 is also used to transfer data from the locator to a host computer.
MyLocator2 is under continual development so the following is a guide to its operation but there may be subtle changes to screens etc. However, the guide should still give sufficient information for the user to navigate MyLocator2.
5.4.1 Launch the Application
To launch MyLocator2, double click on the MyLocator2 shortcut icon. If the host computer is connected to the web, it will check to see if MyLocator2 is the latest version. If it is not, it will ask if you wish to install the latest version. Follow the instructions if you wish to install the new version.
MyLocator2 can be operated on different levels. Each level enables different features and functionality. Some levels require a dongle to operate. Dongles are available from Vivax-Metrotech.
In its basic form it allows the operator to:
Check the software revision number and download the latest version. This feature is useful where
software changes have been made to enhance existing features and to install new free of charge features as they become available.
Upload data files. Files that have been saved in the equipment such as location/GPS data can be
transferred to a PC using MyLocator2.
Adding flash screens: The user can add pictures or company Logo’s of his choice to the start up
screen.
The basic operational screen is displayed below. This will change slightly depending on which tab is active.
5 Data Logging
Page 26 of 72
Connect the vLoc Receiver to the PC using a USB to Mini USB cable. The PC should recognize the vLoc and the display will now change to the below or similar.
It will now be possible to perform the three operations in the tabs shown.
5.4.2 Splash Screen
1. Click the Splash Screen tab. Click on the “Open” button. Browse your computer to find the picture that is intended to be the splash screen.
2. The software will accept the following formats: JPEG, BMP, GIF, PNG, ICO.
3. Select the file and open. The screen below should now also contain a representation of the picture.
4. Press “Download” to transfer the file to the vLoc or “Clear” to remove the file.
5. Clicking on “Scale to LCD” will alter the aspect ratio of the picture to fully fill the screen. Leave this unchecked if no scaling is required. Check the “Centre” button to centre the graphic on the screen.
6. Text can also be added to the flash screen.
7. Use the “Text”, “BG Color” (Background color) and “Font” buttons to add text to the start up flash screen.
5 Data Logging
Page 27 of 72
5.4.3 Upload Data Files
1. Click on the “Import Data” tab. A screen similar to the one below should be shown.
2. Select your preference for Date, Time and Distance.
3. Click on the “Import Data” button.
4. When the upload is complete (Should only take a second or two) it will be possible to save the data.
5. Press the “Save As” button.
6. Browse your computer files to find the desired file location. Name the file and use the “Windows” pull down tab to select the desired file type. (.xl, .txt, .shp or .kml)
7. Press the windows “save” button.
8. Use the “Clear Log” button to clear the log from the locator. Note that this can also be achieved by using a long press on the “-” pushbutton on the locator, when in the depth & current screen.
5 Data Logging
Page 28 of 72
5.4.4 Software Update
1. With the locator switched on and connected to the computer, click on the “Software Update” tab.
2. A screen similar to the one below should be shown.
3. If connected to the Web, press the “Get latest sw rev” button. Alternatively, if the software revision required is already saved, use the “File” button to browse to the relevant file.
4. Click on the “Download” button. The progress bars below will start to activate showing the progress of the software installation. When it is complete a message “software upload complete” will be shown both on the computer and locator screen.
5. Note that the new software will not be active until the unit has been switched off and on again.
5 Data Logging
Page 29 of 72
5.4.5 Advanced Configuration Tool
Clicking the “Advanced” button allows the user to configure the instrument to specific requirements.
The extra features available are:
Switch on or off user menu settings
Switch off frequency selections
By doing this the locator is simplified and tailored exactly to the customer requirements. The configuration can be saved as a “configuration” file and used to configure other vLoc2 locators. This ensures consistency throughout the locator fleet.
5 Data Logging
Page 30 of 72
5.4.6 Switch On/Off User Menu Settings
1. With the locator switched on and connected to the host computer click on the “Menu Settings” tab.
2. A screen similar to the one below should be shown. If not, click on the “Get Cfg” icon on the top bar. This
will load the configuration of the connected locator to the host pc.
3. Check the boxes that are required to be made available.
4. Click on the pull down menu and select the settings required.
5. Clicking on the “Send Cfg” icon will send the configuration to the locator.
5 Data Logging
Page 31 of 72
5.4.7 Switching On/Off Frequency Selections
1. Click on the “Frequencies” tab. A screen similar to the one below should be shown.
2. Each row is color coded: a. Grey indicates that frequency is not selected for either the menu or the frequency key. b. White indicates that the frequency will be active in the locator menu but has not been selected to
show on the frequency key. (Note that it is still possible to make this frequency available on the locator by selecting it in the locator frequency menu.
c. Green indicates that the frequency will be available both in the locator menu and frequency select
key.
d. Blue shows active line.
3. Make the selections required.
4. Clicking on the “Send Cfg” icon will send the configuration to the locator.
5.4.8 Saving a Configuration
Having created a configuration it is possible to save this for future use.
To save a configuration:
1. Click on the “Save Cfg” icon.
2. Browse to a desired file location.
3. Create a name for that file, the extension will be: filename.vmcfg.
4. Press “Save” in the window.
To retrieve the file:
1. Click on the “Open Cfg” icon and browse to select the desired file.
2. Click on “open” in the window.
3. The file will populate the MyLocator2 screen automatically with the settings from the configuration file.
5 Data Logging
Page 32 of 72
5.4.9 Configuration Lock Dongle
A Configuration Lock dongle is available that allows “lockout” of features and functions so that operators are forced to use particular settings. The dongle is also used to unlock these features.
To activate the dongle, plug it into any USB socket on the host computer. With the dongle active, the MyLocator2 screen will look similar to the picture below.
Note the padlocks on the three tabs, Menu Settings, Frequencies and Splash Screen. When a locator is configured with these locks activated, the menu and frequency options in the locators user
menu will not appear, stopping the user from altering the settings downloaded to the locator by the Dongle activated MyLocator2 facility.
To activate the padlocks simply double click on the desired tab.
The features can only be re activated by connecting to a host computer with MyLocator2 which has been dongle activated. Double click on the padlocks as before to unlock them and download the changes to the locator.
5 Data Logging
Page 33 of 72
Example use of the Dongle Lock:
Supposing the Dongle User wishes to force the user to only use 8kHz Peak Mode. The operation would be:
1. Connect the locator to the host computer and switch on. Launch MyLocator2.
2. Click on the “Get Cfg”. This will populate MyLocator2 with the Locators configuration.
3. Click on the “Frequency” tab.
4. Uncheck all frequencies except 8.19 kHz.
5. Check both boxes associated with 8.19 kHz as below.
6. Double click on the Frequency tab to lock the padlock.
7. Now click on the “Menu Settings” Tab
8. Uncheck the Frequency and all antenna modes except “Peak” as below. Note also the Locate Menu box
is un-checked; this will prevent the function appearing in the user menu.
9. Double click on the “Menu Settings” tab to lock the padlock.
10. Now click on the “Send Cfg” icon to send it to the locator.
11. To activate the new configuration switch the locator off and on.
5 Data Logging
5.4.10
Icon Summary
Icon
Function
Opens a previously saved configuration.
Saves a configuration created by the oper
Either Send (saves) configuration to a locator or Get (copy) a configuration from a
locator.
“Clears a configuration created on the configuration tool.
ator to a file of your choice.
Page 34 of 72
6 Loc-10Tx Transmitter
Page 35 of 72
6. Loc-10Tx Transmitter
6.1 Loc-10Tx Transmitter Overview
The Loc-10Tx transmitter is a rugged portable transmitter powered by alkaline “D” cells or Ni-MH (Nickel Metal Hydride) rechargeable batteries. The following describes the features and uses of the transmitter.
Display
1 Frequency Being Transmitted (200 kHz
available in some country)
6 Output Setting (Step) (filled box indicates
current level has been reached, empty box indicates requested current level has not been achieved)
2 Digital Read Out (mA, volts, ohms) 7 Low Power Indicator (enabled automatically
when battery becomes one bar)
3 Loudspeaker Level 8 Battery Status
4 Units (mA, volts, ohms) 9 High Voltage Warning (output is enabled for
high voltage)
5 Mode Indication
Pushbutton
1 On/Off Control
2 Output Decrease
3 Frequency Select
4 Output Increase
5 Information (Volume, mAmps, volts, ohms)
Connections
1 Output Connection
2 Output Protection (Fuse)
3 Loudspeaker
4 Battery Charging Socket & DC Input
6 Loc-10Tx Transmitter
Page 36 of 72
6.2 Transmitter Battery
In most markets the transmitter is shipped with alkaline batteries (12 x D cells) unless rechargeable batteries are specified. Batteries are fitted into quick release trays – the alkaline is an open pack, to enable the batteries to be changed. The rechargeable pack is a sealed unit containing Ni-MH (Nickel Metal Hydride) batteries. These packs can only be fitted in a manner to ensure that the alkaline batteries cannot be inadvertently charged.
6.2.1 Removing the Battery Tray
6.2.2 Replacing the Alkaline Battery
To access batteries – undo stainless steel screws on each battery cover
To remove batteries – turn tray upside down and give a short sharp tap of the battery tray on your
hand
Replace batteries with new batteries of the same type, be sure not to mix old and new batteries
Do NOT use rechargeable batteries in the alkaline battery tray. Ensure that batteries are inserted the
correct way (see label and molded “+” and “-” in the bottom of the tray)
Refit the battery cover – then refit the battery tray
WARNING Alkaline Batteries – insert alkaline batteries (x12) as shown:
6.2.3 Rechargeable Batteries
Do NOT attempt to replace the rechargeable batteries or remove battery covers – return to Vivax-
Metrotech or a Vivax-Metrotech approved service centers for replacement.
WARNING Use only Vivax-Metrotech recommended charger.
Push up button
Pull out bottom of catch Lift up catch until it clears catch plate
6 Loc-10Tx Transmitter
Page 37 of 72
6.2.4 Re-fitting the Battery Tray
Place top of catch over catch plate Push up button underneath the catch – where
holding that up push in the bottom of the catch. You will hear a positive “click” (Do NOT force catches)
To close battery tray – slid transmitter (TX) onto tray, it will locate itself in the correct position, then close the catches.
WARNING Power “IN” socket
Two pins are used for power in from charger (to charge rechargeable batteries). Two pins are used for power from external 12V DC source. A 12V DC power cable is supplied and is designed to be connected to an automobile cigarette lighter socket.
Contact Vivax-Metrotech or a Vivax-Metrotech approved service center for wiring diagram of plug, if attempting to repair any of the “charging” leads.
6.2.5 Battery Charging and Disposal
Follow instructions detailed in the General Safety & Care portion of this document. Only use the battery charger supplied. Using a non approved charger may damage the battery pack and
could cause overheating.
To charge, the batteries must be connected to the transmitter. Connect the mains charger to the charging socket on the side of the transmitter and connect the charger to a suitable mains socket.
The LED will show a red light indicating that the charge cycle is in progress. When the batteries are fully charged the LED will change to green.
NOTE
Rechargeable pack cannot be charged from a 12V DC source.
6.2.6 Battery Condition Indication
The battery condition (charge) is displayed on the left side of the display, in the case of the rechargeable batteries the condition is also indicated on the charger (red/green light).
6 Loc-10Tx Transmitter
Page 38 of 72
6.3 Transmitting Modes
The transmitter has three transmitting modes, which are selected automatically.
6.3.1 Induction Mode
This uses an internal antenna to induce a locating frequency onto the target pipe or cable (line). “Induction” mode is automatically selected if no connection accessories are plugged into the “output socket”. An icon indicating “Induction” mode shows on the display. The icon flashes when the transmitter is transmitting. In order to generate successful induction, the transmitter should be positioned over and with the handle in line with the target line.
“Induction” mode is generally used when no access is available to make a direct connection, or a clamp connection. When using induction it is very likely that the signal being induced onto the target line will also be induced onto other lines in the area, and onto above ground features such as wire fences. This can influence the accuracy of the location, depth and current measurements. “Induction” mode is also the least efficient way of applying the transmitting signal to the target line. The distance located with “Induction” mode is generally much less than that achieved with a direct connection or clamp connection. “Induction” mode generally works better in higher frequencies, 33 kHz, 65 kHz and either 83.1 kHz or 200 kHz (depending on region). The advantage of induction is that no access is required to “connect” the transmitter, making it a very quick process. The antennas on the transmitter are tuned to induce specific frequencies or range of frequencies. Therefore only a limited number of frequencies can be selected in “Induction” mode.
NOTE For accurate location and depth measurement the locator receiver should be used
no closer than 50ft (20m) from the transmitter.
6.3.2 Direct Connection Mode
By plugging in a connection lead to the output socket, “Direct connection” mode is selected. An icon confirming this is shown on the display. The icon flashes when the transmitter is transmitting. The direct connection lead consists of two cables, one (red clip) must be connected to the conductor being located, the other (black clip) to a suitable ground (a ground stake is provided with the transmitter). An auxiliary ground lead is also supplied. If the auxiliary ground lead is used, the ground clip of the connection lead (black clip) is attached to one end of the auxiliary ground lead.
Wherever a direct connection can be safely made without the risk of injury, damage to customer’s plant, or the transmitter, it is the best way of applying the transmitter’s signal.
The coupling of the transmitted signal to other pipes and cables in the area will be much less than with induction, although where commonly bonded systems are encountered – coupling cannot be avoided.
The positioning of the ground connection can also influence the degree of coupling experienced. Ground connections generally should not be made to other pipes or cables, or above ground metallic structures such as wire fences. In general the lower the frequency is, the further the signal will travel, and the less signal coupling will occur. The most common frequencies used for direct connection are between 512 Hz/640 Hz and 8 kHz.
Icon
Icon
6 Loc-10Tx Transmitter
Page 39 of 72
Regulations in many countries require that power output is limited above certain frequencies. The Loc-10Tx enables frequencies below 45 kHz to be transmitted using as much as 10 watts output, but frequencies over 45 kHz are restricted to 1 watt. Using direct connection and the higher power at the low frequencies helps significantly in achieving greater location distances. Direct connections should not be made to cables carrying greater than 35 volts (or as your safety practices allow). The transmitter is protected (250V fuse) from stray currents that may exist on the target line.
6.3.3 Clamp Mode
Plugging the signal clamp supplied by Vivax-Metrotech into the output socket will place the transmitter in “Clamp” mode. An icon confirming this is displayed on the display. The icon flashes when the transmitter is transmitting. When using the clamp no ground connection is needed.
The clamp again is a precise way to apply the locating signal. It is generally used when access to the conductor cannot be achieved to make a direct connection (but there is sufficient access to place the clamp around the cable), or when it is not safe to make a direct connection because the target cable is carrying electricity.
The clamp is a specialized inductive device (sometimes known as a toroid or coupler). All clamps are optimized to work at specific frequencies. In most cases clamps are designed to be used at up to three frequencies only, generally between 8 kHz and 85 kHz. The transmitter will only allow the selection of a suitable frequency for your clamp.
WARNING When applying the clamp to cables that carry electricity – be sure to follow your company’s safety instructions and procedures. Beware that if applied around a high voltage cable – that cable may induce a current in the clamp causing it to snap shut or jump quite dramatically – always apply clamps carefully.
6.3.4 Connection Block
1 Output Connection
2 Output Protection (Fuse)
3 Loudspeaker
4 Battery Charging Socket & DC Input
All the connections made to the transmitter are made at the connection block except for a USB socket which is mounted inside the battery compartment and is used for programming the transmitter’s processor.
The connection block consists of:
Output (XLR) socket – for the direct connection lead and clamp.
Charger socket (to allow the retrofitting of a rechargeable battery pack – the charging socket is
present even if re-chargeable batteries have not been purchased).
Transmitter 12V DC power lead used to power the transmitter from a vehicle (NOT for charging).
Fuse – this protects the transmitter circuitry in the event of the transmitter receiving up to 250V
incoming on the output leads.
A beeper is positioned behind the small hole.
Icon
6 Loc-10Tx Transmitter
Page 40 of 72
6.3.5 Frequencies and Power Output
The Loc-10Tx transmitter is supplied with a predefined set of transmit frequencies.
Standard frequencies are:
512Hz (where electrical systems are 60Hz) direct connection – 10 watts.
640Hz (where electrical systems are 50Hz) direct connection – 10 watts.
65 kHz direct connection – 1 watt.
83.1 kHz, 89 kHz, 131 kHz direct connection – 1 watt (depending on region).
200 kHz direct connection – 1 watt (depending on region).
Induction frequencies are 8 kHz, 33 kHz and 65 kHz or alternatively 33 kHz, 65 kHz and 200 kHz
(Note: 200 kHz is not permitted in some markets). Other combination between 8 kHz, 33 kHz, 65 kHz, 78 kHz and 200 kHz also available. For detail please refer to Loc-10Tx datasheet.
Other frequencies with 10 Watt output:
Direction connection: 256Hz, 491Hz, 512Hz, 982Hz
Direct and clamp connection : 8.19 kHz, 8.44 kHz, 9.5 kHz, 9.82 kHz, 32.8 kHz, 38 kHz
As with most manufacturers the clamps and induction antennas are tuned to specific frequencies, and do NOT work over the complete range.
Frequencies are selected by pressing the “f” pushbutton which toggles through the available frequencies for the selection mode. The frequency is automatically selected if you don’t toggle past it within 2 seconds. The frequency is shown on the display.
The output current is shown in large characters on the display – to increase or reduce the power output press “+” or “-”. The vertical bar graph at the bottom of the display indicates which of the four current output steps is being used. If the transmitter can supply the requested current, the bar will turn black. If the bar does not turn black, improving the ground connections or wetting the ground where the earth stake in positioned, may help. However, it may not be able to achieve the current setting requested because the impedance of the line is too high for this setting. If this happens it is best to select a setting that has a black bar, this will ensure a stable output.
The current being transmitted will be limited by the impedance of the cable, therefore it is not unusual to increase the output level, but see no increase in the current displayed. This is not a fault with the transmitter.
The transmitter will always revert to first level output when switched on – this is a power saving feature – in most circumstances this output level is sufficient. Increasing the output power unnecessarily will reduce the battery life unnecessarily. All other settings remain the same as the last setting used.
Pushbutton
Pushbutton
Pushbutton
6 Loc-10Tx Transmitter
Page 41 of 72
6.3.6 Most Used Frequencies (Frequency Selection) Feature
This feature can be used to allow operator to choose his most used frequencies from a list of possible frequencies. Once these frequencies are selected in the main menu, pressing the "f" pushbutton, user can scroll through them. At any time user can add or remove frequencies from the above list, following the below procedure.
The advantage of this feature is that user can optimize the transmitter and activate at the main menu user’s preferred frequencies, instead of having a whole list of frequencies that user has to scroll through. To enter the "Frequency Menu" proceeds as follows:
1. Press the “i" pushbutton 5 times to get to the "Frequency selection" sub-menu.
2. Screen will show a list of frequencies available, with the central one in a box.
3. Pressing the "+" or "-" pushbuttons, you can scroll up or down through the available frequencies.
4. Once the wanted frequency is inside the box, press “f” pushbutton to select or deselect the frequency. An “x” will appear in the box for a selected frequency.
5. After selecting for the frequencies, press the "i" pushbutton again to exit the “Frequency Menu” and the selected list of frequencies can be select from the main display screen.
6 Loc-10Tx Transmitter
Page 42 of 72
6.3.7 "Dual frequency" Mode
This feature can be used when user wants to energize on user’s target two frequencies at the same time. Mainly, it can be used when user is not sure which frequency can be impressed better into the target.
NOTE
When using "dual frequency" mode, total power will be split between the two
activated frequencies.
This mode of operation is available only for frequencies below 40 kHz. The two frequencies have to be available in the main menu.
To enter the "Choose Second Freq." menu, proceeds as follows:
1. Press "f" pushbutton to select the lowest frequency that user want to have in the dual combination.
2. Press "i" pushbutton 4 times to get to the "Choose Second Freq." sub-menu. The above frequency will be shown in a box.
3. By using the "+" and "-" pushbuttons, user can scroll through the available frequencies and bring the wanted one in the box.
4. Press "f" pushbutton to select the second frequency and exit the submenu to return to the main display.
5. In the main display screen, both frequencies are displayed. The frequency will toggle between the two chosen frequencies.
NOTE If user is changing the selected frequency by pressing the "f" pushbutton, this mode will be deactivated. To reactivate it, user has to follow again the above procedures. If the unit is powered down, this mode will be reset. To activate it again after power up, user has to follow the above procedures.
6.4 Information
When the “i” (information) pushbutton is pressed, the display will show the volume level of the audio; use the “+” and “-” pushbuttons to increase/reduce the volume or turn the beeper off (off – low – medium – high).
By pressing the “i” (information) pushbutton the display can be toggled to show “voltage” and “resistance”. The display indicates mA, as the default, and volts or ohms when selected.
Pushbutton
Pushbutton
Pushbutton
7 Loc-5Tx Transmitter
Page 43 of 72
7. Loc-5Tx Transmitter
7.1 Pushbutton
1 On/Off Control
2 Output Decrease
3 Information (Volume, mA, Volts, Ohms)
4 Frequency Select
5 Output Increase
7.2 External Connectors
1 Mini USB Port
2 Output Fuse
3 Speaker
4 Output Connection
1 Battery Charging Socket & DC Input
2 ¼ turn fasteners
7.3 Transmitter Battery
In most markets the transmitter is shipped with alkaline batteries (8 x D cells) unless rechargeable batteries are specified. Batteries are fitted into quick release trays – the alkaline is an open pack, to enable the batteries to be changed. The rechargeable pack is a sealed unit containing Ni-MH (Nickel Metal Hydride) batteries. These packs can only be fitted in a manner to ensure that the alkaline batteries cannot be inadvertently charged.
7.3.1 Removing the Battery Tray
To remove the tray, operate the three ¼ turn fasteners in an anti clockwise direction. This should now release the tray which can then be slid out from the transmitter body. Be careful not to allow the batteries to fall from the tray as it is removed from the body.
7 Loc-5Tx Transmitter
Page 44 of 72
7.3.2 Replacing Alkaline Batteries
Replace with new batteries of the same type, be sure not to mix old and new batteries
Do NOT use rechargeable batteries in the alkaline battery tray. Ensure that batteries are inserted the
correct way (see label “+” and “-” on the side of the tray)
Refit the battery tray and operate the three ¼ turn fasteners in a clock wise direction.
WARNING Alkaline Batteries – insert alkaline batteries (x8) as shown
7.3.3 Rechargeable Batteries
Do NOT attempt to replace the rechargeable batteries or remove battery covers – return to Vivax-
Metrotech or a Vivax-Metrotech approved service centers for replacement.
WARNING Use only Vivax-Metrotech recommended charger.
7.3.4 Re-fitting the Battery Tray
Refit the battery tray and operate the three ¼ turn fasteners in a clock wise direction.
WARNING Power “IN” socket
Two pins are used for power in from charger (to charge rechargeable batteries). Two pins are used for power from external 12V DC source. (e.g. 12V DC cigarette
lighter supply from automobile)
NOTE
Rechargeable pack cannot be charged from a 12V DC source.
Contact Vivax-Metrotech or a Vivax-Metrotech approved service center for wiring diagram of plug, if attempting to repair any of the “charging” leads.
7.3.5 Battery Charging and Disposal
Follow instructions detailed in the General Safety & Care portion of this document.
Only use the charger supplied with the equipment. Using a non approved battery charger may damage the batteries and cause overheating.
The charger is mains operated. Connect the charger to the battery pack at the rear of the transmitter. Switch on the charger. The LED on the charger will show a red light indicating that the charge process has started. When the LED changes to a green indicator the charge sequence is complete and the batteries will be fully charged.
7.3.6 Battery Condition Indication
The battery condition (charge) is displayed on the left side of the display, in the case of the rechargeable batteries the condition is also indicated on the charger (red/green light).
7 Loc-5Tx Transmitter
Page 45 of 72
7.4 Display
Startup screen, software configuration
Main screen
1 Frequency Being Transmitted
2 Battery Status
3 Signal Current Out (mA)
4 Mode Indication
Clamp Mode
Induction Mode
DC Measurement
If a DC measurement is required, while in the voltage and resistance screen, press and hold the “i” pushbutton. The unit will enter in to the DC measurement sequence and at the end of it will display the DC resistance of the load.
Screen showing DC resistance of the load.
7 Loc-5Tx Transmitter
Page 46 of 72
7.5 Multi Frequencies
To transmit simultaneous up to 3 frequencies proceed as follows:
1. Place the transmitter in the first frequency using the “f” key in the main menu
2. Press the “i” key 3 times. The display will show the screen below with “Freq # 2” and “Freq # 3” flashing. This mean they are not set yet.
3. At this point, with the “up” and “down” keys you can select the second frequency to be transmitted. Once in the proper selection, press the “f” button to confirm. The “Freq # 2” row will not flash any more confirming that it has been set. Repeat the above procedure for the third selection or press “i” to exit this menu, if a third frequency is not needed.
4. Main display will show the “MULTI” as a mode of operation as shown below.
NOTE The “MULTI” mode is only a one time mode. If the unit powered down the MULTI mode has to be reactivated.
7.6 Most Used Frequencies (Frequency Selection) Feature
This feature can be used to allow operator to activate the most used frequencies from a list of possible frequencies. Once these frequencies are selected in the main menu, press the "f" key, scrolls through them. At any time the user can add or remove frequencies from the above list, following the below procedure.
Procedure:
To enter the "Frequency Menu" you can proceed as follows:
1. Press the “i" button 4 times to get to the "Frequency selection" sub-menu.
Screen will show the available frequencies.
2. Pressing the "+" or "-" buttons, you can scroll up or down through the available frequencies.
3. Once the wanted frequency is shown on screen, press “f” button to select or deselect the frequency. An “” will appear in the box for a selected frequency.
After selecting for the frequencies, press the "i" button again to exit the “Frequency Menu” and the selected list of frequencies can be select from the main display screen. Save and exit will automatically happen if there is no button press for about 5 sec while in the "Frequency Menu".
7 Loc-5
Tx Transmitter
7.7
Induction Mode
This uses an internal antenna to induce a locating frequency onto the target pipe or cable (Line). Induction
mode is automatical
ly selected if no connection accessories are plugged into the output socket. In order to
generate successful induction, the transmitter should be positioned over and in line with the target line.
“Induction” mode is generally used when no access is
connection. When using induction it is very likely that the signal being induced onto the target line will also be
induced onto other lines in the area, and onto above ground features such as wire fences. T
the accuracy of the location, depth and current measurements. Induction mode is also the least efficient
way
of applying the transmitting signal to the target line. The distance located with Induction mode is
generally much less than
generally works better in higher frequencies, 33 kHz, 65 kHz and either 83.1
advantage of induction is that no access is required to connect the t
process. The antennas on the transmitter are tuned to induce specific frequencies or range of frequencies.
Therefore only a limited number of frequencies can be selected in Induction mode.
NOTE
For accurate location
used within 50
7.8
Direct Connection Mod
A connection lea
d set is supplied with the Loc
connection to a cabl
e or pipe that is to be traced. One of the leads is connected to the line and the other to a
ground point that is nearby or a by inserting the ground rod supplied with the equipment and connecting to
that.
A good connection is indicated by a change in ton
More information can be found in section
7.9
Clamp Mode
The signal clamp is
an optional extra. There are three different sizes 2
The clamp is generally used
connection is not possible because of safety or access issues.
Please refer to section
6.3.3
available to make a direct connection, or a clamp
that achieved with a direct connection or clamp connection. Induction mode
kHz (depending on region). The
ransmitter, making it a very quick
and depth measurement the locator receiver should not be
ft (20m) from the transmitter.
e
-5Tx transmitter.
This lead set is used to make an electrical
e from the speaker
and a current reading on the display
6.3.2.
in (50mm), 4in
(100mm)
to apply the signal tone to a live cable or t
elecom cable where
for further information.
Page 47 of 72
his can influence
.
, 5in (125mm).
an electrical
8 Loc-1Tx Transmitter
Page 48 of 72
8. Loc-1Tx Transmitter
8.1 Pushbutton
1 On/Off Control
2 Frequency Select
3 Audio Beeper Level
4 Output High/Low setting
8.2 External Connectors
1 Mini USB Port
2 Output Fuse
3 Speaker
4 Output Connection
1 DC Input (power supply only)
2 ¼ turn fasteners
8.3 Replacing Alkaline Batteries
Replace with new batteries of the same type, be sure not to mix old and new batteries
Do NOT use rechargeable batteries in the alkaline battery tray. Ensure that batteries are inserted the
correct way (see label “+” and “-” on the side of the tray)
Refit the battery tray and operate the three ¼ turn fasteners in a clock wise direction
WARNING Alkaline Batteries – insert alkaline batteries (x4) as shown
8.4 Rechargeable Batteries
Rechargeable batteries are not available for the Loc-1Tx transmitter.
8.5 Loc-1Tx Transmitter Operation
The operation of the Loc-1Tx transmitter is very similar to the Loc-5Tx transmitter. This is covered in section 7.7 to 7.9.
9 Using the vLocPro2
Page 49 of 72
9. Using the vLocPro2
9.1 Using the Receiver
9.1.1 Line Locating
Line locating is when a pipe or cable is being located. When line locating, the receiver should be held with the display forward, and then swept to the left and right across the suspected direction of the buried line. Note the compass line direction indicator always points in the direction of the line (active in active modes). The compass color change from clear to blue when the receiver is in line with the buried line.
The receiver should be kept parallel to the ground – and should not be flipped up at the end of each pass. See diagram (a).
To establish the direction of the cable – use whatever mode you prefer to locate the line; then switch to “Peak” mode to confirm the direction. Pinpoint the line – by carefully establishing the exact “Peak” position. Then (with the base of the receiver on the ground) rotate the receiver through 90 degrees, as you do this the signal being received will reduce substantially (possibly disappear). Then rotate the locator until you find the maximum “Peak”. The front of the locator is again facing in the direction of the buried line. See diagram (b).
9.1.2 Depth & Current Measurement
Pinpoint the exact position of the cables as follows:
Locate lateral position of the cable.
Rotate receiver to confirm the direction of the cable (you will see a null response when the receiver is
intersecting the direction of the cable at 90 degrees).
Rotate the receiver back until it is exactly in line with the cable.
Once the position and direction of the cable has been established, stand with the base of the locator
on the ground – with the locator in the absolute “Peak” position (over and in line). Then press the “i” information pushbutton briefly, the current and depth will be displayed.
(a) (b)
(a)
(b)
(c)
9 Using the vLocPro2
Page 50 of 72
9.1.3 Sonde Location
This is used for locating a Sonde only. A Sonde is a transmitting coil and the signal radiates in a different manner than that of a line (see diagram b).
Due to this construction, the Sonde gives a different “Peak” pattern (see diagram b) – note that there are 3 distinct peaks – a small peak – a large peak – a small peak. The Sonde is located under the center of the “large peak”, when locating across the direction of the Sonde it provides the conventional peak response. Note also that the Compass Line Indicator points across the line of the Sonde when the receiver is directly over it and the color of the compass change from clear to blue.
A Sonde is typically used for locating non metallic pipes or ducts, and the camera end of a sewer inspection camera. Low frequency versions (512Hz/640Hz) can transmit through some metallic pipes such as cast iron pipes – which is why they are frequently used with sewer inspection cameras.
The procedure for Depth Measurement is the same as in line location, but must be done in the Sonde mode. Depth measurements taken from a Sonde in any mode other than Sonde mode will be inaccurate.
9.1.4 Using the Compass Feature to Locate Sondes
Switch on the vLocCam. Select the frequency to match the Sonde frequency. Use the mode pushbutton to select Sonde.
Stand in the approximate vicinity of the Sonde. Press the “+” pushbutton to increase the gain so that a steady bar graph reading is displayed. If no or very fluctuating bar graph is shown, it means that the Sonde is not in the expected vicinity. If this is the case pull back the Sonde to a known position, which may be the point the Sonde enters the pipe, and start the search here.
Rotate the locator until the compass is pointing at 12 o’clock. Walk in the direction of the compass keeping the compass pointing at 12 o’clock. The locator will lead you in an arc that crosses over the Sonde. Press the gain pushbuttons to keep the bar graph on scale. The maximum bar graph indicates the position of the Sonde.
(a) (b)
9 Using the vLocPro2
Page 51 of 72
To pinpoint the Sonde, find the peak in both directions.
When over the peak position, the depth is automatically displayed. Press the “i” pushbutton to get a more precise depth reading.
TIP
Using the compass to locate the Sonde requires free space to walk to the side of the Sonde. If there is an obstacle such as a wall or vehicle that restricts walking in an arc, the following method can be used.
Position the locator in the approximate vicinity of the Sonde as above.
Rotate the locator so that the compass is now pointing at 3 o’clock.
Now step to the side keeping the locator pointing in the same direction. The compass will rotate
slightly.
Keeps the locator pointing in the same direction and walk forward. The compass will slowly rotate.
When it reaches 12 o’clock follow the compass keeping it at 12 o’clock.
Pinpoint the Sonde as in the first procedure.
9 Using the vLocPro2
Page 52 of 72
9.2 Passive or Active Location
There are two types of location method available with this system, they are:
9.2.1 Passive Locating
Passive locating is locating buried utilities using the electromagnetic signals that exist in the environment. We group these under two settings:
Power (P) – these are signals that generally originate from electrical power generation systems.
These are around 50/60 Hz and their associated harmonic.
Radio (R) – these are signals that are generally originated by low frequency radio transmissions.
These are generally in the range of 16 kHz to 22 kHz.
Passive location is used to search an area to see if buried metallic lines are present (known as locating to AVOID). It does not help to identify what buried pipe or cable is present, only to confirm that there is a pipe or cable there. A typical application would be to check an area before installing a fence post.
9.2.2 Active Locating
Active locating is using a transmitter to apply a very precise frequency to a pipe or cable, and then using a receiver turned to find the signal being radiated at that precise frequency. Active location frequencies can be applied by direct connection, clamp or induction.
This receiver provides a wide range of frequencies for active location. Some will be the same as the frequencies provided by the Vivax-Metrotech’s transmitter, others will be frequencies used in other manufacturers’ transmitter.
The choice of frequencies when using induction or the clamp is restricted due to the requirement that these modes be tuned for specific frequencies (or range of frequencies). The full range of frequencies is available in “Direct connection” mode.
For frequencies below 45 kHz, authorities such as the FCC allow higher power output to be used; for frequencies of 45 kHz and above, power output for this type of equipment is restricted to 1 watt. Therefore more power is available when lower frequencies are used.
9 Using the vLocPro2
Page 53 of 72
9.3 Applying the Transmitter’s Signal
The transmitter’s signal cable is applied in any one of the three ways:
9.3.1 Direct Connection
This is used on pipes or cables that are not live and do NOT carry hazardous voltages. The “Direct connection” mode will be selected automatically when the connection leads are plugged into the transmitter.
WARNING Never make a direct connection to live cables carrying hazardous voltages.
Do NOT plug the connection leads into the transmitter before connecting to the buried line and fixing the ground stake.
Take the ground stake and push firmly into the ground and connect it to the black connection lead.
To make the signal travel further along the buried line, ensure to place the ground stake as far away as possible, and at 90 degrees to the line. Where practical avoid having other buried lines between the ground stake and the target line, this will reduce the chances of the transmitter signal coupling to another pipe or cable.
Do NOT connect the black lead to any other metallic items that may have an above or below ground structure, or to any other pipes or cables; connecting to such items would cause signals to radiate from these secondary structures, which in turn will increase the likelihood of an incorrect locate.
Connect the red connection lead to the target line after removing any surface corrosion.
Plug the connection leads into the transmitter switch on and select the desired frequency.
WARNING BE CAREFUL not to hit other buried lines when inserting the ground stake into
the ground. Check using passive location prior to inserting ground stake. Stop if additional resistance is felt during insertion.
9.3.2 Clamp (Coupler)
This is used when applying the transmitter signal to cables carrying hazardous voltages, or cables where access to the metallic conductor is not possible, or desirable. The “Clamp” mode is selected automatically when the clamp is plugged into the transmitter.
For a clamp to work the current induced by the clamp must flow along the buried line. This means the buried line must have a ground connection at both ends.
9 Using the vLocPro2
Page 54 of 72
Do NOT plug the clamp into the transmitter before applying it to the target line. Open the jaws of the clamp, place around the target line, close the jaws. Be sure that the jaws of the clamp are completely closed. After applying the clamp, plug it into the transmitter, switch on and select the required frequency. Clamps are generally turned to specific frequencies. Your transmitter only allows frequencies that are compatible with the clamp to be selected.
Please note – at the end of the clamp, and in the area close to the clamps hinge the exposed end of the clamp laminations can be seen. Any dirt or corrosion on these ends will reduce the efficiency of the clamp.
WARNING ALWAYS follow the appropriate safety requirements mandated by safety legislation, safety practice or your company’s safety procedures when applying a clamp (coupler) to a cable.
BEWARE that when placing a clamp around cables carrying high current, the clamp may vibrate, jump or close violently due to inducted current from the target cable.
9.3.3 Induction
This is used when no connection via direct connection leads, or coupler is possible. If no connection leads or clamp are connected to the transmitter, it will automatically select “Induction” mode.
An induction loop is fitted inside the handle of the transmitter. The transmitter must be placed over the target cable with the handle over and in line with the target pipe or cable. The induction loop is tuned to operate at specific frequencies. Only these frequencies can be selected when in “Induction” mode.
Do NOT place the transmitter on a manhole cover, or any other such metallic object, as that object will shield or soak up the signal resulting in little of no signal being induced in the target line.
When using the “Induction” mode to apply a signal to a line, ensure that a minimum distance of 50ft (20m) is maintained. This is because the transmitter will transmit signal through the air which will interfere with signals from the cable, resulting incorrect information.
9 Using the vLocPro2
Page 55 of 72
9.3.4 Searching (sweeping) an Area
In any given area, it is likely that buried pipes and cables are not parallel to each other, frequently they will cross the area being searched at a variety of different angles and depths. As the response of locator antennas is directional, it is important to search the area in the same or similar pattern as below. This orients the antennas in a way that will locate any signals being radiate from the buried line. Once a response is found, then trace and pinpoint the line and mark. Searching an area in this way is generally (but not exclusively) done in the “Peak” mode using passive locating.
9.3.5 Tracing a Buried Line
Once a buried line is located it is generally necessary, and a good practice, to trace that line for some distance in both directions. Whenever practical it should be traced to a point that provides additional confirmation of what type of service is being located (a telephone pedestal, a manhole cover etc). If tracing a line to which a transmitter signal has been applied, one should trace out from the transmitter connection point. The receiver should be held level to the ground and rotated in a small arc across the anticipated route of the buried line. A clear response should be visible on the display and heard audibly.
9.3.6 Pinpointing & Confirming the Buried Line
Marking the exact position of the buried line is generally called pinpointing. Pinpoint the line before marking its position. Place the receiver in “Peak” or “Left/Right” mode, pass the blade of the receiver across path of the cable and identify the peak response on the display and/or audibly.
(a) (b)
9 Using the vLocPro2
Page 56 of 72
9.3.7 Distorted Fields
When locating always be aware that you are locating the signals radiating from the buried line, and these radiated fields as they are called can be distorted by other lines or electromagnetic buried lines or metallic features like crash barriers or wire mesh fences. The risk of an inaccurate location can be reduced further by the following:
Check to see if the signal is being distorted by other radiated fields. Locate the cable, first in the
“Peak” mode, and then in the null mode. The two locations should indicate that the cable is in the same place. If they do not, the signal field is distorted and the depth measurement may be inaccurate.
Measure the depth of the buried line by pressing “i” pushbutton briefly to measure depth and current.
The depth should be approximately in line with the “as built” plans available. If no plans are available logic would still help to assess the situation (if you are looking for a CCTV distribution cable and the depth indicated is 5ft (1.5m) it is probably not your cable). Current will be displayed at the same time as the depth.
A depth reading on congested areas of close to bends or tee’s maybe inaccurate due to distorted
fields.
1 Null Position
2 True Position
3 Peak Position
9 Using the vLocPro2
Page 57 of 72
9.3.8 Measuring Depth and Current
Pinpoint the cable as described in “Pinpointing cable”, with the receiver in line with and directly above
the buried line – measure the depth (d) by pressing “i” pushbutton briefly. Current will be displayed at the same time as the depth.
Be careful when locating in congested areas or close to bends or tee’s, they may be inaccurate due
to distorted fields.
An alternate method of verifying depth (D) is triangulation. There are two methods of triangulation, 50%
and 70% rules. If using the 50% rule Broad peak mode (single antenna) should be used or peak mode if using the 70% rule. On some models there is an option that instructs the user in taking triangulation measurements. In this case the antenna selection is done automatically so the operator does not need to select the antenna configuration.
Semi Automatic Triangulation Mode
On some models a "triangulation mode" is available that assist in taking these types of measurements.
To use the Triangulation mode the function must first be activated in the User Menu. The user Menu will give the option of Peak Depth or Triangulation. If Triangulation is selected, either 50% or 70% rules will be initiated. 50% or 70% rules are selected by connecting the unit to MyLocator2 and selecting “Menu Settings” and then the desired rule in the “Depth Mode” tab.
To use the function first locate the cable or pipe in the usual way. Press the “i” pushbutton and a depth will be indicated. To confirm with triangulation, press the “i” pushbutton again.
The following screen should be shown.
Now slowly move the locator to the side until the line on the graph reaches the 50% line. (or 70% if the 70% rule is used). At this point an audible beep will confirm this position is reached. Mark the ground at this point and then slowly return to the peak position. Continue past this position until the 50% mark is reached on the other side. Mark this position.
Distance A to B = Depth (D) Distance (A’ to B’)/2 = Depth (D)
9 Using the vLocPro2
Page 58 of 72
Now measure the distance between these two points. Divide the distance by two. The result will indicate the depth of the target line.
If the 70% rule is used, do not divide by two, the depth is equal to the distance between the points.
Current Measurement
Measure the current. This is displayed when you briefly press the “i” pushbutton to measure depth. The signal from the transmitter will attenuate with distance. The further you are away from the transmitter the less signal will radiate from the buried line. By locating at several points along the buried line you will identify an approximate rate of signal loss (beware that where a pipe or cable divides the signal will reduce more rapidly). If the signal at the point you are pinpointing is different from the trend would suggest – between that, it may not be the buried line you expect.
WARNING NEVER mechanically dig over the path of a buried pipe or cable. ALWAYS dig carefully.
9.3.9 Signal Direction Precision Identification
(Available for vLocPro2-SD model only)
Some models in the vLoc series of locators contain a feature called “SIGNAL DIRECTION”. This feature is used to verify if the line being located is the line to which the transmitter has been connected.
When a transmitter is connected to a target line the signal travels along it and finds the easiest way to travel back, usually via the ground and ground stake. However, very often the signal will travel back along adjacent cables or pipes as these can offer an easier route.
As a result there can be multiple signals radiating from cables and pipes in the area making it difficult to identify the target line. These return signals are typically traveling in the opposite direction than the applied signal. The Signal Direction feature identifies which direction the signal is flowing and hence the target line.
To use the signal direction system:
Connect the transmitter to the target line using a direct connection only.
Turn the transmitter and receiver on and set both to:
o SD-USA – if in North America or any territory where the power system is 60Hz. o SD-EUR – if in Europe or any territory where the power system is 50Hz.
The receiver may, or may not be flashing the “SD” icon and compass bezel. "A flashing icon and
bezel indicates that the unit needs to be synchronized with the transmitter.” Even if the icon is not flashing it is always good practice to synchronize the system at the beginning of a survey to ensure reliable results and to maximize the distance to the next synchronization point.
9 Using the vLocPro2
Page 59 of 72
To synchronize the receiver to the transmitter at the beginning of a survey, pinpoint the line very close
to the transmitter – be sure that it is the correct line. Then, standing facing away from where the transmitter is attached and press the “i” pushbutton. The unit will now display the information screen showing the depth of line, signal current and a hand with the “SD” icon positioned over the return pushbutton. Pressing the return pushbutton will synchronize the system and return the unit to the locate screen. The top portion of the bezel surrounding the compass will light and not be flashing indicating the receiver is locked onto the signal. The system is now synchronized.
Proceed to locate, trace, pinpoint as required ensuring at all times the top portion of the compass
bezel remains illuminated.
If at any time top portion of the bezel ceases to be illuminated and the bottom portion of the compass
bezel lights up – you are not locating the correct line, you are locating a line which is carrying the return signal.
At some point you may find that the top or bottom portion of the compass bezel together with the SD
icon and start flashing – this is indicating that synchronization with the transmitter has deteriorated and a reset is required.
9 Using the vLocPro2
Re-
trace your line back to a point where a solid signal direction is obtained. Precisely pinpoint the line
and stand
with your back to the direction of the transmitter as you did when you initiated the original
sync and press the i pushbutton then the enter pushbutton to re
Continue to locate, pinpoint and trace.
NOTE
If several
the other lines. This is useful for locating multiple line installations.
However be aware
line that line will also appear as b
When performing a reset, take care to ensure that you have not strayed from
the target line.
9.4 Using the
Accessories
9.4.1 Using the
LPC
The LPC separation filter
(LPC) is used to safely inject a trace to
socket, so that the cable can be traced from the premises to the connection in the street. It is suitable for
connecting to voltages between 100V AC and 250V AC.
Method:
Plug the LPC into the output socket of the tr
the socket, switch off. Plug in the LPC to the mains socket
switch to match the two indicator lights.
are good frequencies for this application). Set the output to mid range.
-
sync with the transmitter signal.
lines are commonly bonded the Signal Direction will carry through to
that if a non target line is commonly bonded to the target
eing “in Sync” with the target line.
Separation Filter
ne to a live cable via a domestic mains
ansmitter. Identify a suitable main socket. If a switch is fitted to
and then switch back on
Set the transmitter to the frequency to b
e located.(8 kHz or 32 kHz
Page 60 of 72
. Set the LPC rotary
9 Using the vLocPro2
9.4.2 Using the A-
frame
The A-
frame accessory is used to detect ground faults on pipes and cables. In the case of pipes
consi
st of coating defects. In the case of cables, faults are usually caused by insulation damage allowing the
metallic sheath (or internal conductor) to become in contact with the ground.
To detect a damaged section, the line should be isolated and have all gr
ensure that the ground fault is not masked by delib
between these two situations.
After isolating the line, use the
measuring device to confirm that there is a fault to ground. The A
mega ohm and above (d
epending on the distance from transmitter, soil conditions etc)
Connect the transmitter to the
ground and the black cable clipped to it. Try to place the
evaluated. This ensures return currents do
FF low or FF high. Use FF high if the line to be surveyed is long or the fault resistance is high.
in Fault Finding
ound bonding removed. This will
erate bonding to ground. The A-
frame
vLocPro2 transmitter resistance measuring function
, or a dedicated resistance
-
frame will typically detect faults up to 2
.
target line using the red lead. A ground
stake needs to be pushed into the
ground
stake as far as possible from the line to be
NOT distort the results. Sw
itch on the transmitter and select either
Page 61 of 72
, the faults
cannot distinguish
9 Using the vLocPro2
Page 62 of 72
Plug in the A-frame to the receiver accessory socket. When the receiver is switched on, it will automatically default to the A-frame screen.
Remove the plastic spike covers from the A-frame. Walk along the route of the line placing the spikes of the A-frame in the ground (with the green leg pointing away from the transmitter connection point) every two or three paces. If starting near the transmitter, the Arrow on the display will point away from the ground point. As the distance from the transmitter increases, the dBuV reading will reduce and eventually the arrow will fluctuate or disappear all together. This is because the fault location is further along the line. If the left/right arrows are activated, use them to ensure the A-frame is positioned over the line and continue placing the A­frame in the ground every two or three paces. If the left/right arrows are not activated use the “M” pushbutton to enter the locate screen allowing the user to confirm the position of the target line. Press the “M” pushbutton again to re enter the A-frame mode.
Eventually the A-frame will detect the fault signal and the “Fault Find” arrow will point forwards. Continue moving forwards, it may be worth reducing the distance between measurements points as the fault is neared. The dBuV reading will increase as the fault is neared. Maximum reading will be just before and just after the fault. When over the fault, the dBuV reading will drop and the arrow will flip backwards indicating that the position of the fault has been passed. Carefully place the A-frame before and after the fault to pinpoint the position. Repeating this across the line direction will pinpoint the fault laterally. The fault will be at the point where the lateral fault is identified.
WARNING Always disconnect or isolate cables before making connections to conductors.
Never attach the transmitter to live cables unless authorised. Use the appropriate accessories.
TIP If it is suspected that there is just one fault. Insert the A-frame approximately one meter from the earth stake. Note the dBuV, this is approximately the maximum dBuV reading that will be measured over the fault.
Image for reference only and may differ from actual image
9 Using the vLocPro2
9.4.3 Using the
Remote Antenna USB
The remote stethoscope antenna can be used to help identify a particular cable on a cable tray or where
cables are bunched together.
Methods:
1.
Connect a signal to the cable to be identified. The remote
frequency range of 512Hz up to 200
as they are less likely to leak or bleed over to other cables.
2. The best method
of signal application whe
the signal clamp applies a signal to the target cable and shares an equal amount with other cross bonded
cables.
3. When using the
signal clamp, both ends of the target cable should be grounded. App
the ground point. Applying the clamp above the ground point will prevent the signal finding the return path
through the ground,
so is not advised.
4.
If this is not possible use a transmitter signal clamp
service,
use a direct connection lead to
bonding between cables prevents the signal travelling along commonly bonded cables.
5. Do NOT
use the Induction
stethoscope functions has an operational
kHz, but low frequencies should be a preference in this application
n identifying cables is to use
the signal clamp. This is because
and you have confirmation that
make
an electrical connection to the cable. Removing any cross
method as the signa
l will appear on all cables in the area of the transmitter.
Page 63 of 72
ly the clamp below
the cable is out of
9 Using the vLocPro2
Page 64 of 72
6. Connect the remote stethoscope antenna to the accessory input of the Receiver. The correct settings and user interface will be automatically selected.
7. Ensure the frequency selected on the vLoc is the same as selected on the transmitter.
8. Place the stethoscope on each of the suspected target cables with the flats of the antenna in line with the route of the cable.
9. Note the large dBuV reading in the centre of the screen for each cable. The one with the largest reading is likely to be the target cable.
10. If necessary adjust the sensitivity of the vLoc so that the signal is within the operating section of the bar graph. This will help identify the cable if the signal levels are similar because of cross coupling of the signal.
WARNING The remote stethoscope antenna is a useful tool to help identify cables.
However, it should not be used as positive identification before an unused cable is cut. Always follow company procedures when cutting disused or isolated cables.
TIP The remote antenna USB stethoscope can be used to help identify disused and
isolated cables. This process can be further enhanced if the cable is isolated and is of a twisted cable construction.
9 Using the vLocPro2
Page 65 of 72
Method:
1. Connect the transmitter to two of the cores of the cable. At the far end short together these two conductors making a loop.
2. Set the transmitter to a low frequency such as 640Hz and set the output to maximum.
3. At the point of interest, run the remote stethoscope antenna along the suspected target cable. If the correct cable is being assessed the signal will increase and decrease in sympathy with the twist of the two conductors within the cable.
4. If the signal is a steady level and does not rise and fall, this is probably NOT the target cable.
WARNING The remote stethoscope antenna is a useful tool to help identify cables. However, it should not be used as positive identification before an unused cable is cut. Always follow company procedures when cutting disused or isolated cables.
Signal response from target line
Flat response from cable that is not target cable
10 Accessories & Options
10.
Accessories
10.1 A-frame
(Optional)
10.2
Remote Antenna
10.3 Loc-10Tx
Vehicle Power Lead
10.4 Loc-10Tx
O
10.5
LPC Separation Filter
10.6 Receiver
Vehicle Charg
& Options
The A-
frame accessory is used to detect ground faults on pipes and
cables. In the case of pipes, the faults consist of coating defects. In the
case of cables, faults are usually caused by insulation
the metallic sheath (or internal conductor) to become in contact with the
ground.
(Optional)
The remote antenna can be used to help identify a particular cable on a
cable tray or where cables are bunched together.
(Optional)
12V DC, 30ft (10m)
lead to power the transmitter from a vehicle.
Note, this is NOT a charge lead.
If it is intended to apply the transmitter to a target line at high output
levels and long periods, it may be useful to
power the transmitter using
the 12V DC vehicle power lead. To power the transmitter from the 12V
DC vehicle power lead, connect the lead to the 12V DC input positioned
on the side of the transmitter. Plug the cigarette lighter plug into the
vehicle cigare
tte lighter socket (be sure that the socket is live. Some
vehicles only activate the cigarette lighter when the vehicle is running).
It is not necessary to disconnect or remove the standard batteries as
the unit will automatically select the external 12V
DC supply.
utdoor Power Supply (Optional)
12V DC, 30ft (10m)
lead to power (NOT charge lead) the transmitter
from the mains supply.
Note, this is NOT a charge lead.
(Optional)
The LPC separation filter (LPC) is us
ed to safely inject a trace tone to a
live cable via a domestic mains socket, so that the cable can be traced
from the premises to the connection in the street. It is suitable for
connecting to voltages between 100V AC and 250V AC.
ing Lead (Optional)
12ft (4m)
long lead to charge the receiver’s battery
on the move.
It is preferable to connect the charger to a cigarette lighter socket that is
permanently live. However, do NOT leave connected to the receiver for
excessively long periods.
Page 66 of 72
damage allowing
(Lithium-ion) while
10 Accessories & Options
10.7 Sonde
(Optional)
10.8 Clamp
(Optional)
VX2/50,
VX4/100, VX5/125,
Dia. 2in (50mm),
Dia. An accessory used to apply the transmitter signal to an insulated line, removing the need to connect the
transmitter signal directly to a conductor or cable sheath.
D18-33-SR44 Sonde
0.7in (18mm) x 3.
2
kHz, range 15ft (4.5
m)
2 x button cell batteries.
D38-33-AA Sonde
1.5in (38mm)
x 4.1in
kHz, range 16.3ft
(5m)
1 x AA battery.
D38-09-AA Sonde
1.5in (38mm)
x 4.1in
kHz, range 16.3ft
(5m)
1 x AA battery. D38-83-AA Sonde
1.5in (38mm)
x 4.1in
kHz, range 16.3ft
(5m)
1 x AA battery. D64-33-LR61 Sonde
2.5in (64mm)
x 7.3in
kHz, range 26ft
(8m)
1 x LR61 battery.
D64-09-LR61 Sonde
2.5in (64mm)
x 7.3in
kHz, range 26ft
(8m)
1 x LR61 battery. D64-83-LR61 Sonde
2.5in (64mm)
x 7.3in
kHz, range 26ft
(8m)
1 x LR61 battery. D23F-512-AA / D23F-
640
1in (23mm) x 18in
(456mm)
20ft (7m).
“Flexible (3 section) Sonde with optional
512Hz or 640Hz for use in cast iron
pipes”.
1 x AA battery.
VX18/450F
5in (125mm), Dia. 4in (100mm), 18in flexible
(Circumference 450mm)
Page 67 of 72
in (81mm) long, 33
.
(105mm) long, 33
.
(105mm) long, 9.8 .
(105mm) long, 83
.
(186mm) long, 33
.
(186mm) long, 9.8
.
(186mm) long, 83
.
-AA Sonde
long, range
10 Accessories & Options
10.9 Lithium-i
on Rechargeable Battery Pa
10.10 Receiver
Battery Charger
10.11 USB Cable
10.12
Alkaline Battery Holder
10.13
Ground Stake
10.14
Direct Connecti
10.15 Loc-
1Tx Alkaline Battery Tray
ck
(Standard
The Lithium-ion rechargeable battery pack is
supplied as standard. Use
the b
attery charger listed below to charge the battery pack. Charging
done with the battery inside the receiver.
(Standard)
The receiver Lithium-ion battery
charger is supplied as a standa
It is powered from the mains supply (100-
250V AC)
(Standard)
The USB cable is used to connect the receiver to a host computer so
that software updates can be implemented and also fo
data logs from the unit to a computer.
(Standard)
This battery pack is supplies as standard and is used in the event the
rechargeable battery pack has fully discharged. It can be considered as
a backup batter
y pack. It requires 6 x AA alkaline batteries
(Standard)
Used to make an independent connection to the ground so as to
complete the circuit when the transmitter is connected to a line using
the direct connection method.
on Lead (Standard)
Used to connect the t
ransmitter to a line using the d
method.
(Standard)
Requires 4 x Alkaline D cells.
Page 68 of 72
)
is
rd item.
r the transfer of
.
irect connection
10 Accessories & Options
10.16
Ground Spool
10.17
Banana Plugs
10.18 Loc-
5Tx Battery Pack (Ni
10.19 Loc-
5Tx Alkaline Battery Tray
10.20 Loc-
5Tx/10Tx Charger
10.21 Loc-
10Tx Rechargeable Battery Tray
10.22 Loc-
10Tx Alkaline Battery Tray
(Optional)
Used to extend the ground connection to a suitable g
Adapter (Optional)
Adapts the direct connection crocodile clip to banana plug allowing the
direct connection leads to be connected to a banana socket.
MH)
NiMH rechargeable battery pack. Only
use the charger supplied as
below.
Requires 8 x Alkaline D cells.
Mains charger (100-
250V AC input) used to charge 5 Watt or 10 Watt
rechargeable battery packs.
Supplied as standard with recharg
battery option.
NiMH rechargeable battery pack.
Only use the charger supplied.
Requires 12 x Alkaline D cells.
Page 69 of 72
rounding position.
eable
11 Glossary
Page 70 of 72
11. Glossary
Active Locate A locate where a transmitter is used to apply a signal to a buried pipe or cable,
the position of which is then located by a receiver tuned to the same frequency.
Active Signal A signa l applied by the locator transmitter to a buried line. Typical this is a very
precise frequency.
Attenuation The reduction of an electromagnetic signal from a pipe or cable.
Clamp (or Coupler) An accessory used to apply the transmitter signal to an insulated line, removing
the need to connect the transmitter signal directly to a conductor or cable sheath.
Compass Line direction indicator (although visually like a compass, this is the only
relation to a compass.)
Coupling The act of signals transferring to lines to which they were not originally applied.
Coupling can be “direct” where the target line has an electrical connection to another line, or “induced” where the signal radiates from the target line to another line or lines.
Display The information visually available on the dot matrix display.
Line A generic term for any buried pipe or cable.
Null A minimum response to a buried line.
Passive Locate A locate where the receiver searches for a wide range of signals that radiate
from buried pipes or cables. These signals come from a variety of sources in the environment and couple to the buried (& overhead) lines. Typical examples 50 / 60Hz and LF/VLF radio.
Passive signals A wide range of signales that radiate from buried pipes or cables. These
signals come from a variety of sources in the environment and couple to the buried (& overhead) lines. Typical examples 50/60Hz and LF/VLF radio.
Peak A maximum response to a buried line.
Pinpoint Using a receiver to identify the exact position of a buried line.
Response The indication that the receiver gives which is caused by the signals it is
receiving. This can be visual, audio or both. Typically it is displayed on the locators dot matrix display and audibly from a loudspeaker in the receiver housing.
Search (sweep) This describes the act of looking for a buried line within a given area.
11 Glossary
Sonde
Target Line
Trace
Illustrations used in the preparation of this manual w
illustrations from other Manufacturers
graphics (Vivax-
Metrotech & Seba) is given credit for the
credit.
Disclaimer:
Product and accessory specification and availability information is subject to change without
prior notice.
A sma
ll transmitting coil which may be built into a product such as a sewer
camera or packaged as a small self contained battery powered transmitter. A
receiver tuned to the same frequency can locate the position of the Sonde and
hence whatever it is attached t
o or in. Frequently used for locating sewer
cameras, and the non metallic pipes.
The buried pipe or cable to be located.
Using a locator to following the path of a buried line.
ill inevitably show some resemblance to similar
-
some manufacturers have given permission for the use of their
s
e use. This statement is intended to attribute su
Page 71 of 72
ch
Notes:
_________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________
Vivax-Metrotech Corporation 3251 Olcott Street, Santa Clara, CA 95054, USA Website: www.vivax-metrotech.com
Loading...