The Vitrek instrument is warranted against defects in material and workmanship
for a period of one year after the date of purchase. Vitrek agrees to repair or
replace any assembly or component (except batteries) found to be defective,
under normal use, during the warranty period. Vitrek's obligation under this
warranty is limited solely to repairing any such instrument, which in Vitrek's
sole opinion proves to be defective within the scope of the warranty, when
returned to the factory or to an authorized service center. Transportation to the
factory or service center is to be prepaid by the purchaser. Shipment should not
be made without prior authorization by Vitrek.
The warranty does not apply to any products repaired or altered by persons not
authorized by Vitrek, or not in accordance with instructions provided by Vitrek.
If the instrument is defective as a result of misuse, improper repair, or abnormal
conditions or operations, repairs will be billed at cost.
Vitrek assumes no responsibility for its product being used in a hazardous or
dangerous manner, either alone or in conjunction with other equipment. Special
disclaimers apply to this instrument. Vitrek assumes no liability for secondary
charges or consequential damages, and, in any event, Vitrek's liability for breach
of warranty under any contract or otherwise, shall not exceed the original
purchase price of the specific instrument shipped and against which a claim is
made.
Any recommendations made by Vitrek or its Representatives, for use of its
products are based upon tests believed to be reliable, but Vitrek makes no
warranties of the results to be obtained. This warranty is in lieu of all other
warranties, expressed or implied, and no representative or person is authorized
to represent or assume for Vitrek any liability in connection with the sale of
Vitrek products other than set forth herein.
Instrument Serial Number: __________________________________
4 XT560 Digital Milliohmmeter User Guide
Document Part Number: MO-560-M Revision 2.0
Print date: April 7, 2009
Copyright
Copyright 2006 Vitrek All rights reserved.
All rights reserved. No part of this publication may be reproduced,
transmitted, transcribed, stored in a retrieval system, or translated into any
language in any form without prior written consent from Vitrek. This
product manual is copyrighted and contains proprietary information, which is
subject to change without notice. The product's displays and manual text may
be used or copied only in accordance with the terms of the license agreement.
is a trademark of Vitrek. All other trademarks orregistered
trademarks are acknowledged as the exclusive property of their respective
owners.
In the interest of continued product development, Vitrek reserves the right to
make changes in this guide and the product it describes at any time, without
notice or obligation.
Manufacturers of Engineering & Production Test Equipment
Front Panel ____________________________________________________ 10
Front Panel Display __________________________________________ 11
Rear Panel ____________________________________________________ 12
Dimensions and Stand Operation ___________________________________ 13
Case Dimensions ____________________________________________ 13
Stand Operation _____________________________________________ 13
Using the Meter _________________________________________________ 14
Range Selection _____________________________________________ 14
HOLD Mode ________________________________________________ 15
Figure 1. Front Panel _____________________________________________ 10
Figure 2. Rear Panel _____________________________________________ 12
Figure 3. Meter Dimensions _______________________________________ 13
Figure 4. Stand Retracted _________________________________________ 14
Figure 5. Standing Position ________________________________________ 14
Figure 6. Stand as a Handle _______________________________________ 14
Figure 7. Changing Positions ______________________________________ 14
Figure 8. Four-wire Measurement Diagram ____________________________ 15
Figure 9. Calibration with Resistor Standard ___________________________ 18
Figure 10. RS-232 Connector Pin-out ________________________________ 20
Introduction
The purpose of this user guide is to describe the use and capabilities of the
XT560 Digital Milliohmmeter.
Scope
The XT560 Digital Milliohmmeter is a dedicated, fully automatic instrument
that selects the optimal test current, from 100nA to 100mA DC to accurately
measure resistances from 10μΩ to 33MΩ. The XT560 will auto range
between 9 ranges, or can be manually set to a fixed range. The XT560
includes a set of Kelvin test clip leads for making four-terminal
measurements.
Introduction 8
The XT560 is ideal for measuring wiring or cable resistances, windings of
motors or generators, lamp filaments, cable splices, wire-to-terminal
resistances, heating elements, contact resistance of breakers or switches,
connector quality/resistance, fuse resistances, transformers, and grounding
connections.
Features
The XT560 Digital Milliohmmeter’s features include the following—
Maximum Display of 33000
Power Supply 90VAC to 260VAC, 50/60Hz
Wide Measurement Range: From 10μΩ resolution to 30MΩ full
scale