Vitek VT-PIRC2-H User Manual

VT-PIRC2/H
VITEK
1/3” Sony High Density CCD (960H) with 700 TV Lines
Minimum Illumination of 0.2 Lux / 0.1 Lux
Pinhole 3.7mm / F2.0 Lens Included
NC/N/NO Alarm Output
Working 100’ Motion Detection Using 58 Beams Within 3
layers (35’ x 35’ Coverage Area)
PIR BOARD LAYOUT
1. LED: When an intrusion is detected, the LED will activate.
2. JP1: Pulse count setting.
1-2 short: Relay will activate when an intrusion is detected once. (For stable environments or high risk operating environments) 2-3 short: Relay will activate when an intrusion is detected twice within 15 seconds. (For harsh environments)
3. JP2: Relay output select. Short: For outer control used in area where DC12V is requested (Limited at 200mA). Normal: N.C. = DC12V out Activate: N.O. = DC12V out Open: Normal relay connector (1.5A at DC24V/1.5A at AC120V/1A at AC240V) Normal: C & N.C. short / C & N.O. open. Activate: C & N.C. open / C & N.O. short.
Caution! Risk of electric shock. Set-up and operation should be performed by Authorized Service Person only.
4. VR1: Sensitivity adjustment.
Turn clockwise for high sensitivity, turn counter-clockwise for low.
5. VR2: Relay activation time adjustment (range about 2 ~ 30 seconds). Turn clockwise for short time, turn counter-clockwise for long.
6. NC/C/NO Wiring: C: BLACK NO: WHITE NC: YELLOW
CN1 Connector:
1. DC 12V IN
2. GND
3. AUDIO OUT (option)
4. GND
5. VIDEO OUT
6. RELAY C. (common)
7. RELAY N.O. (normal open)
8. RELAY N.C. (normal close)
CN2 Connector:
1. AUDIO IN (Not Available In US)
2. VIDEO IN (from CCD MODULE)
3. GND
4. DC 12V/120mA OUT (for CCD MODULE)
2