Vitek VT-8114 GD User manual

VT-8114 GD
Vacuum cleaner
3
7
12
16
Пылесос
1
E N G L I S H
VACUUM CLEANER VT-8114 GD
This unit is intended for room cleaning.
DESCRIPTION
1. Floor/carpet UltraClean brush
2. “FLOOR/CARPET” mode switch
3. Telescopic pipe lock
4. Telescopic extension pipe
5. Flexible hose handle
6. Manual suction power control
7. Flexible hose
8. Flexible hose ending
9. Flexible hose ending locks
10. Air inlet
11. Carrying handle
12. Dustbag compartment lid lock
13. Dustbag compartment lid
14. Full dustbag indicator
15. Power cord winding button
16. Suction power control
17. ON/OFF button
18. Dustbag holder
19. Dustbag locks
20. Reusable cloth dustbag
21. Inlet filter
22. Inlet filter clamp
23. Outlet filter grid
24. Outlet filter
25. Cloth dustbag plastic clamp
26. Floor/carpet brush horizontal
and vertical storage
27. Combined crevice nozzle brush
28. Outlet filter grid lock
ATTENTION!
For additional protection you can install a residual current device with nominal operation current not exceeding 30 mA into the mains; contact a spe­cialist for installation.
SAFETY MEASURES
Read this instruction manual carefully before using the unit and keep it for the whole operation period. Use the unit for its intended purpose only, as specified in this manual. Mishandling of the unit may lead to its breakage and cause harm to the user or damage to his/her property. To avoid the risk of fire, electric shock and to pre­vent injury, observe the following safety measures.
Before connecting the unit to the mains, make
sure that the voltage specified on the unit cor­responds to your home mains voltage.
To avoid fire, do not use adapters for connect-
ing the unit to the mains.
Do not leave the plugged in vacuum cleaner
unattended. Always unplug the vacuum cleaner from the mains if it is not being used, before changing attachments or before unit maintenance.
To prevent the risk of electric shock, do not
use the vacuum cleaner outdoors, do not use it for collecting water or other liquids (do not use the vacuum cleaner on wet surfaces).
Carry the vacuum cleaner holding it by the
carrying handle only.
Do not use the power cord for carrying the
vacuum cleaner, do not close the door if the power cord runs through the doorway, do not let the power cord come in contact with sharp corners or edges of furniture, and with hot surfaces. Do not run over the power cord with the vacuum cleaner while room cleaning as this can damage it. Always first switch the vacuum cleaner off with the ON/OFF button and only after that take the power plug out of the mains socket.
When unplugging the unit, pull the plug but
not cord.
Do not touch the plug or the body of the vac-
uum cleaner with wet hands.
Hold the winding cord with hand to avoid the
plug hitting against the floor.
Do not cover the unit outlet with foreign
objects.
Do not switch the unit on if any of its openings
are blocked.
Keep hair, free hanging clothes, fingers and
other parts of your body away from the vac­uum cleaner suction opening.
Close attention is necessary while cleaning
the stair landings.
Do not use the vacuum cleaner for collecting
such highly inflammable liquids as gasoline and solvents, do not use the vacuum cleaner in places where such liquids are stored.
Do not use the vacuum cleaner for collecting
water and other liquids, burning or smoking cigarettes, matches, cinders as well as fine dust, for example, of plaster, concrete, flour or ashes.
Do not use the vacuum cleaner, if:
the dustbag is not installed or installed
improperly;
the inlet and outlet filters are not installed.
3
ENGLISH
Do not immerse the unit body into water or
other liquids.
Use only the accessories and attachments
supplied.
Clean the vacuum cleaner regularly.
Keep the vacuum cleaner in a dry cool place.
Do not use the vacuum cleaner to clean pets.
Close supervision is necessary when chil-
dren or disabled persons are near the oper­ating unit.
This unit is not intended for usage by children.
During the unit operation and breaks between operation cycles, place the unit out of reach of children.
The unit is not intended for usage by physi-
cally or mentally disabled persons (including children) or by persons lacking experience or knowledge if they are not under supervision of a person who is responsible for their safety or if they are not instructed by this person on the usage of the unit.
Do not leave children unattended to prevent
using the unit as a toy.
For children safety reasons do not leave poly-
ethylene bags, used as a packaging, unat­tended.
Attention! Do not allow children to play with polyethylene bags or packaging film. Danger of
suffocation!
Transport the unit in the original package only.
Regularly check the power plug and power
cord integrity for damages.
Never use the unit if the power cord or the
power plug is damaged, if the unit works improperly or after it was dropped.
Do not repair the unit by yourself. Do not dis-
assemble the unit by yourself, if any mal­function is detected or after it was dropped, unplug the unit and apply to any authorized service center from the contact address list given in the warranty certificate and on the website www.vitek.ru.
Keep the unit out of reach of children and dis-
abled persons.
Unpack the unit completely and remove any
stickers that can prevent unit operation.
Check the unit for damages; do not use it in
case of damages.
Before switching the unit on, make sure that
your home mains voltage corresponds to the unit operating voltage.
Note: Always switch the vacuum cleaner off and take the power plug out of the socket before replacing the brush attachments, cleaning or replacing the dustbag (20).
Attaching and removing the flexible hose
Insert the flexible hose ending (8) into the air
inlet (10).
Insert the hose with a slight effort until locking.
If you need to remove the flexible hose, press
the locks (9) and detach the hose.
Attaching the telescopic pipe and the attachments
• Attach the telescopic extension pipe (4) to the flexible hose handle (5).
• Extend the lower part of the telescopic extension pipe to the required length, having preliminarily pressed the lock (3).
• Choose the necessary attachment – floor/ carpet brush (1) or combined crevice nozzle brush (27) – and attach it to the telescopic extension pipe (4).
USING OF THE BRUSH ATTACHMENTS Floor/carpet UltraClean brush (1)
Set the switch (2) on the brush (1) to the required position (depending on the type of the surface being cleaned).
Combined crevice nozzle brush (27)
The crevice nozzle brush (27) is intended not only for cleaning radiators, crevices, corners or space between cushions, but for collecting dust from furniture surface as well, the pile on the brush (27) prevents damage of polished furni­ture surface.
THE UNIT IS INTENDED FOR HOUSEHOLD USAGE ONLY
Using the dustbag (20)
2 cloth dustbags (20) with a convenient plastic clamp are supplied with the unit.
ASSEMBLING THE VACUUM CLEANER
After unit transportation or storage at low temperature, keep it for at least three hours at room temperature before switch­ing on.
Open the dustbag compartment lid (13) by
pressing the lid lock (12).
Take the dustbag holder (18) and pull it to
remove the dustbag holder (18) and the dust­bag (20) from the locks (19).
4
E N G L I S H
To clean the cloth dustbag (20) place it
above the trash bin and remove the plastic clamp (25). After cleaning install the plastic clamp (25) back to its place.
To install the dustbag (20) back to its place,
insert the dustbag holder (18) into the notches of the locks (19 ) as far as it will go.
Close the dustbag compartment lid (13).
Note: Always make sure that the dustbag holder (18) and the dustbag (20) are installed prop­erly before closing the dustbag compartment lid (13). After every installation carefully tuck the dustbag (20) edges into the dustbag com­partment and then close the lid (13 ).
USING THE VACUUM CLEANER Safety measures
Do not use the vacuum cleaner near hot sur-
faces, such as ashtrays and in places where inflammable liquids are stored.
Take sharp objects away from the floor before
cleaning to prevent damage to the unit.
If the suction power of the vacuum cleaner
decreases rapidly while cleaning, switch it off immediately and check the telescopic pipe and the flexible hose for obstruction. Switch the vacuum cleaner off, then unplug it, remove the obstruction and only after that continue cleaning.
OPERATION
Attention! Always switch the vacuum cleaner on only with the dustbag (20) and inlet (21) and outlet (24) filters installed. Always make sure that the filters are installed properly.
Before using the unit, unwind the power cord
to the required length and insert the power plug into the mains socket.
The yellow mark on the power cord indicates
the maximum cord length. Do not unwind the power cord further than the red mark.
Press the ON/OFF button (17 ) to switch the
vacuum cleaner on.
During the operation you can control the
suction power using the suction power con­trol (16) and the manual suction power con­trol (6) on the flexible hose handle (5).
After room cleaning switch the vacuum
cleaner off by pressing the ON/OFF but­ton (17 ) and unplug the unit.
To wind the cord press the cord winding but-
ton (15), hold the winding cord with your hand to avoid its whipping and damage.
CLEANING AND CARE
If the full dustbag indicator (14) turns red dur-
ing operation, clean up the cloth dustbag.
Before cleaning or replacing the dustbag (20)
switch the vacuum cleaner off and unplug it. To clean the cloth dustbag (20) place it above the trash bin and remove the plastic clamp (25). If necessary, wash the cloth dust­bag with warm water and neutral detergent and dry thoroughly, after that install the plastic clamp back to its place.
Provide that the inlet filter (21) and the outlet
foam filter (24) are always clean, because the overall performance of the vacuum cleaner depends on it; clean the filters no less than 3-4 times a year, and more often at severe obstruction.
Cleaning the inlet filter (21)
Switch the vacuum cleaner off and unplug it.
Open the dustbag compartment lid (13) by press-
ing the lock (12). Remove the dustbag (20).
Take the inlet filter (21 ) and remove it from the
clamp (22) by pulling it upwards.
Wash the inlet filter (21) with warm water,
dry thoroughly and install it into the grid holder (22).
Install the dustbag (20) back to its place.
Close the dustbag compartment lid (13).
Cleaning the outlet filters (24)
Switch the vacuum cleaner off and unplug it.
Remove the outlet filter grid (23) by press-
ing the lock (28). Remove the outlet filter (24) from the grid (23).
Wash the filter (24) under slightly warm water
jet. Do not wash the filters in a dishwashing machine.
Dry the filter (24). Do not dry the filters with
a hairdryer.
Install the filter (24) into the grid (23) accord-
ing to its form.
Install the outlet filter grid (23) with the
installed filter (24) back to its place.
Notes:
Before installing the filters (21, 24) make sure
that they are dry.
Do not dry the filters (21, 24) with a hairdryer.
5
ENGLISH
Vacuum cleaner body
Wipe the vacuum cleaner body with a soft,
slightly damp cloth and then wipe it dry.
Do not immerse the body of the vacuum
cleaner, the power cord and the power plug of the unit into water or other liquids. Provide that no liquid gets inside the vacuum cleaner body.
Never use solvents or abrasives to clean the
surface of the vacuum cleaner.
STORAGE
Before taking the vacuum cleaner away for
long term storage, clean its body, the dustbag and the filters (21, 24).
For easy storing use the horizontal or vertical
brush storage (26).
Keep the vacuum cleaner away from children
in a dry cool place.
TECHNICAL SPECIFICATIONS
Supply voltage: 220-240 V ~ 50 Hz Power consumption: 1800 W Suction power: 350 W
The manufacturer reserves the right to change the unit specifications without a preliminary notification.
Unit operating life is 3 years
Guarantee
Details regarding guarantee conditions can be obtained from the dealer from whom the appli­ance was purchased. The bill of sale or receipt must be produced when making any claim under the terms of this guarantee.
DELIVERY SET
1. Vacuum cleaner with the filters and the cloth
dustbag installed – 1 pc.
2. Flexible hose – 1 pc.
3. Telescopic extension pipe – 1 pc.
4. Floor/carpet UltraClean brush – 1 pc.
5. Combined crevice nozzle brush – 1 pc.
6. Additional cloth dustbag – 1 pc.
7. Instruction manual – 1 pc.
This product conforms to the EMC­Requirements as laid down by the Council Directive 2004/108/ЕС and to the Low Voltage Regulation (2006/95/ЕС)
6
Loading...
+ 14 hidden pages