Insufficient room humidity negatively affects
humans’ and pets’ health as well as plants and
furniture. The recommended comfortable room
humidity level is from 40% to 60%. The VT-2334 W
humidifier allows you to improve the air quality in
the room.
DESCRIPTION
1. Lid with a mist release opening
2. Water tank
3. Water inlet
4. Water tank lid
5. «Sprayer»
6. On/no water indication
7. ON/OFF knob/mist release intensity control
8. Body
ATTENTION!
For additional protection it is reasonable to
install a residual current device (RCD) with
nominal operation current not exceeding
30 mA. To install RCD, contact a specialist.
SAFETY MEASURES
Before using the electrical unit, read this instruction manual carefully and keep it for future reference.
Use the unit for its intended purpose only, as
specified in this manual. Mishandling of the unit
may lead to its breakage and cause harm to the
user or damage to his/her property.
• Before switching the unit on, make sure that
voltage of the mains corresponds to unit operating voltage.
• Place the unit on a flat, moisture-resistant sur-
face. The distance to the walls, other furniture
and interior objects should be at least 30 cm.
• Do not place the unit on carpet surfaces with
high pile.
• Do not place the air humidifier in places
exposed to direct sunlight, high temperatures,
near computers or other sensitive electronic
appliances.
• Do not use the unit outdoors.
• Use the supplied removable parts only.
• Do not operate the unit without water; switch
the unit off when the water tank is empty.
• Do not use soda or dirty water or any perfume
additives.
• Water temperature should not exceed +40°С.
• Do not switch the unit on if the water tank is
not installed.
• Unplug the unit before removing the water
tank.
• Do not cover the unit.
• Do not cover the openings on the unit body
and avoid getting of foreign objects inside
them.
• Do not immerse the unit body, the power plug
or the power cord into water or any other liquids.
• Do not move or tilt the unit during the opera-
tion and do not remove the water tank.
• Always unplug the unit and pour out water
from the water tank and the process chamber before cleaning or if you do not use the
air humidifier.
• Before moving the unit to another place,
unplug it and pour out water from the water
tank and the process chamber. When carrying
the unit, hold it by the body with both hands.
• Do not touch the power plug with wet hands.
• Clean the unit regularly.
• Do not allow children to touch the unit body
and the power cord during operation.
• This unit is not intended for usage by children.
• The unit is not intended for usage by physi-
cally or mentally disabled persons (including
children) or by persons lacking experience or
knowledge if they are not under supervision of
a person who is responsible for their safety or
if they are not instructed by this person on the
usage of the unit.
• Do not leave children unattended to prevent
using the unit as a toy.
• For children safety reasons do not leave poly-
ethylene bags, used as packaging, unattended.
Attention! Do not allow children to play with
polyethylene bags or packaging film. Danger of
suffocation!
• Never pull the power cord when disconnect-
ing the unit from the mains; take the power
plug and carefully pull it out of the mains
socket.
• Never use the unit if the power cord or the
power plug is damaged, if the unit works
improperly or after it was dropped.
• Do not attempt to repair the unit. Do not disas-
semble the unit by yourself, if any malfunction
is detected or after it was dropped, unplug
the unit and apply to any authorized service
center from the contact address list given in
the warranty certificate and on the website
www.vitek.ru.
3
IM VT-2334.indd 302.12.2016 12:45:20
ENGLISH
• Transport the unit in the original package only.
• For environment protection do not discard the
unit with usual household waste after its service life expiration; apply to a specialized center for further recycling.
• Keep the unit out of reach of children and dis-
abled persons.
THE UNIT IS INTENDED FOR HOUSEHOLD
USAGE ONLY
BEFORE THE FIRST USE
After unit transportation or storage under cold
(winter) conditions, it is necessary to keep it for
at least three hours at room temperature.
There may be water spots in the air humidifier,
this is normal, as the unit has undergone factory
quality control.
– Unpack the unit, remove any stickers and
package materials that can prevent unit operation. Check the unit for damages. In case of
damages do not switch the unit on.
– Before plugging the unit in make sure that
your home mains voltage corresponds to the
unit operating voltage.
Notes:
– Use the air humidifier at the room tempera-
ture from +10° С to +40°С, and relative humidity less than 80%.
– Water temperature should not exceed +40°С.
AIR HUMIDIFIER OPERATION
• Remove the lid with mist release openings (1)
from the tank (2).
• Remove the tank (2) from the unit body (8).
• Turn the tank (2) over, take the lid (4) off by
turning it counterclockwise.
• Fill the tank (2) with the required amount of
water, insert the lid (4) in the water inlet (3)
and turn it clockwise.
• Place the filled water tank (2) on the unit
body (8).
• Insert the power plug into the mains socket.
• Switch the air humidifier on, turning the
knob (7) clockwise, the ON indicator (6) will
light up.
• Set the mist release intensity by turning the
knob (7).
• If the water tank (2) is empty, the indicator (6)
will light up red.
• Switch the air humidifier off, turning the knob
(7) counterclockwise as far as it will go, the
indicator (6) will go out. Unplug the unit. Fill
the tank (2) with water, install it to its place and
switch the unit on.
• After finishing the operation, switch the air
humidifier off, turning the knob (7) counterclockwise until bumping, the indicator (6) will
go out; after that remove the power plug from
the socket.
Note:
– the continuous operation time of this humidi-
fier is 8 hours.
– if the humidifier is switched off and there is
still some water in the tank, turn the knob (7)
to the left until bumping and switch the humidifier on again, turning the knob (7) clockwise
and setting the necessary mist release intensity.
CLEANING AND CARE
WARNING! Always switch the air humidifier
off and unplug it before maintenance works or
cleaning.
• Hard water causes the appearance of mineral
scale on the sprayer (5), on the inner parts of
the body and in the water tank; that leads to
improper operation of the air humidifier and
the appearance of white deposits on objects
of the interior.
• To avoid this, it is necessary to clean the
sprayer (5) weekly and to change water in the
tank (2) as often as possible.
• If you are not going to use the humidifier for
a long time, pour out water from the tank (2)
and the operating chamber of the sprayer (5),
wash the water tank (2), wash and clean the
operating chamber of the sprayer (5) and the
sprayer (5) itself, dry the unit thoroughly and
take it away for storage.
Weekly care
• Once a week wash the water tank (2) and the
process chamber of the «sprayer» (5) thoroughly with neutral detergent solution.
• Then rinse them with water carefully.
• Add 5-10 drops of the detergent on the
sprayer (5), wait for about 2-5 minutes.
Remove the deposits from the sprayer (5)
surface with a brush.
Note: As a cleaning agent for the sprayer (5) you
can use scale removers for kettles.
• Clean the air humidifier body (8) with a soft
slightly damp cloth, and then wipe it dry.
• Do not immerse the air humidifier body (8),
the power cord and the power plug into water
4
IM VT-2334.indd 402.12.2016 12:45:20
E N G L I S H
or other liquids. Provide that no liquid gets
inside the air humidifier body (8).
• Do not use solvents or abrasives to clean the
surface of the body (8) and the water tank (2).
make sure that all its parts are dry, including the process chamber of the sprayer (5).
• Do not store the unit with water in the
tank and in the process chamber of the
sprayer (5).
STORAGE
• If you are not going to use the unit for a long
• Keep the air humidifier away from children in
a dry cool place.
time and want to take it away for storage,
TROUBLES AND TROUBLESHOOTING
Problem Possible causesTroubleshooting
The ON indicator doesn‘t light
up, no mist release.
No supply voltage.Connect the unit to the mains.
Plug another, known good appliance to the
socket to make sure that the socket works
properly.
The indicator is glowing red,
Water tank is empty. Fill the water tank with water.
no mist release.
Mist smells unpleasantly. First use of the unit. Unscrew the water tank lid, pour out the
water and leave the tank open for 12 hours
in a cool dark place.
Dirty or stale water. Unplug the unit, remove the water tank,
pour out the water, wash the tank and fill it
with clean boiled or distilled water.
Low mist release intensitySprayer is dirty.Unplug the unit and clean the sprayer.
Foreign noise during the air
humidifier operation
The unit is placed
on an uneven or
Unplug the unit and level the unit body or
move the air humidifier to another place.
unstable surface.
Note:
– Non-observance of the rules for cleaning the
sprayer (5) from mineral deposits affects the
air humidifier performance. In this case clean
the unit.
– If the tap water used is hard, use household
TECHNICAL SPECIFICATIONS
Supply voltage: 220-240 V ~ 50 Hz
Power consumption: 23 W
Water tank capacity: 2.8 l
Water flow: ≥ 300 ml/h
Humidified area: up to 25 m
2
filters for additional water cleaning or mix it
with distilled water in proportion 1:1
The manufacturer preserves the right to change
DELIVERY SET
Air humidifier – 1 pc.
the specifications of the units without a preliminary notification
Removable lid with nozzle – 1 pc.
Removable water tank – 1 pc.
Unit operating life is 3 years
Removable water tank lid – 1 pc.
Instruction manual – 1 pc.
Guarantee
Details regarding guarantee conditions can be
obtained from the dealer from whom the appliance was purchased. The bill of sale or receipt
must be produced when making any claim under
the terms of this guarantee.
5
IM VT-2334.indd 502.12.2016 12:45:20
русский
УВЛАЖНИТЕЛЬ VT-2334 W
Недостаточная влажность в помещении негативно сказывается на здоровье человека,
домашних животных, растениях и предметах мебели. Рекомендуемый комфортный
уровень относительной влажности воздуха
в помещениях составляет от 40% до 60%.
Увлажнитель VT-2334 W позволит улучшить
качество воздуха в помещении.
ОПИСАНИЕ
1. Крышка с отверстием для выхода «пара»
2. Резервуар для воды
3. Отверстие для заливки воды
4. Крышка резервуара для воды
5. «Распылитель»
6. Индикатор включения/отсутствия воды
7. Ручка вкл./выкл./регулятор интенсивности
выхода «пара»
8. Корпус
ВНИМАНИЕ!
Для дополнительной защиты целесообразно установить в цепи питания устройство защитного отключения (УЗО) с
номинальным током срабатывания, не
превышающим 30 мА, для установки УЗО
обратитесь к специалисту.
МЕРЫ БЕЗОПАСНОСТИ
Перед началом эксплуатации электроприбора
внимательно прочитайте настоящее руководство по эксплуатации и сохраните его для
использования в качестве справочного материала.
Используйте устройство только по его прямому назначению, как изложено в данном
руководстве. Неправильное обращение с
устройством может привести к его поломке,
причинению вреда пользователю или его имуществу.
• Перед включением убедитесь, что напря-
жение электрической сети соответствует
рабочему напряжению устройства.
• Устанавливайте устройство на ровной вла-
гостойкой поверхности. Расстояние до
стен, других предметов мебели и интерьера должно быть не менее 30 см.
• Запрещается устанавливать устройство на
напольные покрытия с длинным ворсом.
• Не размещайте увлажнитель в местах, под-
верженных воздействию прямых солнечных лучей, высоких температур, вблизи
компьютеров или чувствительной элек-
тронной техники.
• Запрещается использовать устройство вне
помещений.
• Используйте только те съёмные детали,
которые входят в комплект поставки.
• Не включайте устройство без воды и
отключайте его, как только в резервуаре
закончится вода.
• Не используйте газированную или загряз-
нённую воду, а также парфюмерные
добавки.
• Температура используемой воды не
должна превышать +40°С.
• Не включайте устройство без установлен-
ного резервуара для воды.
• Отключайте устройство от электросети
перед снятием резервуара для воды.
• Не накрывайте устройство.
• Не закрывайте имеющиеся отверстия на
корпусе устройства и не допускайте попа-
дания в них посторонних предметов.
• Не погружайте корпус устройства, сетевой
шнур либо вилку сетевого шнура в воду или
другие жидкости.
• Во время работы устройства не переме-
щайте и не наклоняйте его, а также не сни-
майте резервуар для воды.
• Обязательно отключайте устройство от
сети и выливайте воду из резервуара и
рабочей камеры во время чистки или если
вы не пользуетесь увлажнителем.
• Прежде чем перенести устройство в дру-
гое место, отключите его от электросети
и слейте воду из резервуара для воды и
рабочей камеры. При переноске устрой-
ства держите его обеими руками за корпус.
• Не прикасайтесь к вилке сетевого шнура
мокрыми руками.
• Регулярно проводите чистку устройства.
• Не разрешайте детям прикасаться к кор-
пусу устройства и к сетевому шнуру во
время работы устройства.
• Данное устройство не предназначено для
использования детьми.
• Прибор не предназначен для использова-
ния лицами (включая детей) с пониженными
физическими, психическими и умствен-
ными способностями или при отсутствии
у них опыта или знаний, если они не нахо-
дятся под контролем или не проинструкти-
рованы об использовании прибора лицом,
ответственным за их безопасность.
6
IM VT-2334.indd 602.12.2016 12:45:21