Vitek VT-1984 GY User Manual [ru]

VT-1984 G/GY
Electronic personal
Весы напольные
электронные
3
7
12
17
22
1
VT-1984.indd 1 07.05.2014 17:21:59
VT-1984.indd 2 07.05.2014 17:22:00
E N G L I S H
PERSONAL SCALE VT-1984
The scale is intended for measuring body weight and percentage of fat, water and muscle and bone tissue in a human body.
This scale uses bioelectric body impedance analy­sis «BIA» method that allows to precisely calculate the percentage of fat, muscle and bone tissue, and water. The calculation is based on personal data (height, age, sex) entered into the unit’s memory.
DESCRIPTION
1.
Platform
2.
Contact areas
3.
Display
4.
Data selection touch buttons «/»
5.
Data selection and confirmation touch button «SET»
6.
Measurement units selection button «UNIT»
7.
Battery compartment lid
RECOMMENDATIONS FOR CUSTOMER ATTENTION!
Before using the unit, read this instruction manual carefully and keep it for future reference. Use the unit for intended purposes only, as speci­fied in this manual. Mishandling the unit can lead to its breakage and cause harm to the user or damage to his/her property.
SAFETY MEASURES
Using the excess weight analysis function is TOTALLY contraindicated to pregnant women.
Using the excess weight analysis function is TOTALLY contraindicated to people having pacemakers and other medical devices with built-in batteries.
Handle your scale with care, as it is a precision instrument, do not subject it to high or low tem­peratures, high humidity, never expose it to direct sunlight and do not drop it.
Use the scale away from heating units.
Avoid getting of liquids into the scale body, this appliance is not waterproof. Do not store or use the scale in a room with high humidity (above 80%), make sure that the scale does not come into con­tact with water or other liquids as this may cause failure of scale indication or its damage.
Place the scale on a flat, dry and non-slip surface.
The scale readouts will be more accurate if you do not use the scale on carpets or rugs.
Do not step on the scale with wet feet or if the scale surface is damp, otherwise you can slip and get injured.
Be careful while stepping on the scale: step on the scale first with one foot; make sure that the scale is steady and only then step on it with both feet.
Step on the scale and dispose your weight evenly. Stand still while weighing. Do not jump on the scale surface.
If you are not planning to use the scale for a long time, remove the batteries from the battery com­partment.
Strictly follow the polarity according to the mark­ings when replacing the batteries.
Replace the batteries in time.
This unit is not intended for usage by children under 8 years of age.
This unit is not intended for usage by people (includ­ing children over 8) with physical, neural, mental disorders or with insufficient experience or knowl­edge. Such persons may use this unit only if they are under supervision of a person who is responsible for their safety and if they are given all the necessary and understandable instructions concerning the safe usage of the unit and information about danger that can be caused by its improper usage.
Do not leave children unattended to prevent using the unit as a toy.
For children safety reasons do not leave polyeth­ylene bags used as packaging unattended.
Attention! Do not allow children to play with polyethyl­ene bags or packaging film. Danger of suffocation!
To avoid damages, transport the unit in original package only.
Do not repair the scale by yourself.
Refer to authorized service centers for mainte­nance.
Keep the unit out of reach of children and dis­abled persons.
THE UNIT IS INTENDED FOR HOUSEHOLD USAGE ONLY
IMPORTANT: Electromagnetic compatibility
The electronic scale can be sensitive to electro­magnetic emission of other units located in close proximity (such as mobile phones, portable radio transmitters, radio controllers and microwave ovens). In case of such influence (false or inconsistent data indication on the display), use the scale away from the source of interference.
BEFORE THE FIRST USE
After unit transportation or storage at low tem­perature, it is necessary to keep it for at least two hours at room temperature before switching on.
3
VT-1984.indd 3 07.05.2014 17:22:00
ENGLISH
If there is a protective film on the scale surface, remove it.
Clean the scale with a soft, slightly damp cloth and then wipe it dry.
BATTERY INSTALLATION AND REPLACEMENT
Remove the battery compartment lid (7) and insert 2 «AAA» batteries (supplied with the unit), strictly following the polarity.
Place the battery compartment lid (7) back to its place.
Note: If there is an isolation insert in the battery compartment, remove the battery compartment lid (7), remove the isolation insert and install the lid back to its place.
Battery replacement
When the battery is low, the symbol «Lo» will appear on the display (3).
Open the battery compartment lid (7), replace the «AAA» batteries with new ones, strictly following the polarity, and close the lid (7).
If you do not use the scale for a long time, remove the batteries from the battery compartment.
WHAT IS EXCESS WEIGHT?
It is generally known that excessive body weight can negatively affect health. Excess weight can cause obesity, heart problems, facilitate atherosclerosis and osteoporosis; but deficient body weight may also lead to osteoporosis. (Osteoporosis is a sys­temic skeleton disease characterized by reduced bone density and impairment of bone tissue micro­architectonics and leading to increased bone fra­gility and risk of fracture by minimal trauma or even without it). Physical exercises and a moderate diet help to lose excess weight and this scale will help to control your weight. It is known that in case of low weight muscles and body tissues contain more water than fat. Electric current passes through water better than through fat. Sending weak current through the body, the scale quickly and easily calculates the percentage of fat and water in a human body. You can control your weight relying on the results of the calculation.
Percentage of fat in the body depends on differ­ent factors and can change during the day.
When calculating fat and water percentage of children under 10 years of age, the results may be inaccurate.
Professional sportsmen, people inclined to ede­mas and people with nonstandard body propor­tions can show inaccurate results of calculation.
Note: Fat, bone and muscle tissue and water percentage can be calculated only if personal data (sex, age, height) are entered correctly and if you step on the scale barefoot.
SWITCHING ON
Place the scale on a flat solid surface; if the floor is uneven or covered with a carpet or rug, the weighing accuracy decreases.
The scale is switched on when a weight over 5 kg is placed on the platform or by touching the «SET» button (5).
MEASUREMENT UNITS SELECTION
Switch the scale on using one of the options described above.
To select weight measurement units, press the «UNIT» button (6) repeatedly.
Measurement units are shown on the display (3):
«kg» – weight is measured in kilograms; «lb» – weight is measured in pounds; «st:lb» – weight is measured in stones and
pounds.
WEIGHT MEASUREMENT
Step on the scale to switch it on.
Keep your feet parallel to each other and distrib­ute your weight evenly.
Stay still while weighing. During weight measure­ment the weight values will be flashing on the dis­play (3), and after measurement they will glow constantly.
Attention!
If a symbol «Err» appears on the display (3), it means that the scale is overloaded. Step off the scale immediately to avoid its damage.
The scale will be switched off automatically in about 10 seconds after weight measurement.
RECOMMENDATIONS
Weigh yourself at the same time of the day.
It is recommended to measure fat and water per­centage in the evening before supper.
At least 2-3 hours should pass after the meal.
At least 10-12 hours should pass after intensive physical exercises.
ENTERING PERSONAL DATA (pic. 1)
Touch the «SET» button (5), one of the user num- bers «P-01», «P-02».., «P-12» will be flashing on the display.
Select the necessary user number using the but­tons (4) «▲/▼» . You can enter data for 12 users. Confirm your selection with the «SET» button (5).
4
VT-1984.indd 4 07.05.2014 17:22:00
E N G L I S H
Then the flashing symbol of the sex will be shown on display. Use the buttons (4) «▲/▼» to select
symbol for women or the symbol for
the men. Confirm your selection by the «SET» but­ton (5).
Then the height values in centimeters will be flashing on the display. Set the height in the range from 100 to 220 cm using the buttons (4) «/», press the «SET» button (5) to confirm your set­tings.
The age values (age) will be flashing on the dis­play. Set the age in the range from 10 to 80 years using the buttons (4) «/». Touch the «SET» button (5) to save the age data.
Then the zero weight value «0.0» will be shown on the display, it means that the scale is ready to cal­culate your parameters.
CALCULATION OF FAT, BONE AND MUSCLE TIISUE AND WATER PERCENTAGE IN A HUMAN BODY
Touch the «SET» button (5).
Select a user number with the buttons (4) «▲/▼». User data entered earlier (sex, height, age) will be shown on the display.
Wait until the symbols «0.0» are shown on the display.
Step with your bare feet on the scale so that both feet are on the contact areas (2) at the same time. Stay still during the weight mea­surement and wait till the weight indications appear.
Keep standing on the scale. After calculation the following data will be shown on the display (3): fat (FAT), water (BW), bone (BON) and muscle
(MUS) percentage and recommended level of daily calorie intake (KCAL).
The weight and results of calculation will be shown several times more, then the unit will be switched off automatically.
Note: IT IS NECESSARY to enter personal data into the unit memory before measuring fat, water per­centage, etc. Wait till the fat percentage is shown before you step off the scale. If a symbol «Err» appears on the display (3), it means that the scale is overloaded. Step off the scale immediately to avoid its damage. Maximum weight capacity of the scale is 150 kg. The symbol «Err2» shows that an error occurred during calculation. Step off the scale, make sure that the data is entered correctly and repeat weighting.
Change of fat percentage in a human body during the day
The indications of fat percentage in a human body are affected by such factors as lifestyle, physical activity, health condition, and also water percentage in the body. You should take into account the following factors:
the fat percentage indications may be less if mea­sured after taking a bath or a shower,
the fat percentage indications may be higher if measured after having meal or drinking,
percentage of liquid in a human body may decrease and thus change the fat percentage indications during and after illness and after physical exercises.
FAT PERCENTAGE IN A HUMAN BODY
Women Men
Age
Underweight Normal
Excessive
weight
Obesity Underweight Normal
Excessive
weight
Obesity
10-39 14-20 21-25 26-31 32-38 11-17 18-23 24-29 30-36
40-55 15 -21 22-26 27-32 33-38 12-18 19-24 25-30 31-37
56-80 16-22 23-27 28-33 34-38 13-19 20-25 26-31 32-38
Water percentage in a human body (BW)
Water percentage in a human body (BW) is the per­centage ratio of liquid in the human body and the total weight. Water is of primary importance for func­tioning of human tissues and organs, since 50-65% of our body consist of water, with this scale you can control the percentage of water in your body and cor­rect this important characteristic.
NORMAL WATER PERCENTAGE IN A HUMAN BODY
Age Women Men
10- 15 57-67 58-72
16-30 47-57 52-67
31-60 42-52 47-61
61-80 37- 47 42-56
5
VT-1984.indd 5 07.05.2014 17:22:00
ENGLISH
What is muscle bulk (MUS)?
The muscle bulk (MUS) value shows the weight of locomotor system muscles, smooth muscles (heart and digestive system) and water in these muscles. Control of muscle bulk is especially important for people with excessive weight. Weight loss may lead to decrease of fat tissues, but only if you gain muscle bulk at the same time.
What is bone mass (BON)?
Bone tissues are the base of human skeleton; they are solid and resistant to external stress, protecting inter­nal organs, and together with the muscle tissue the bone tissues provide the ability of a human to move. Bone mass measurement is based on calculating the minerals mass in a human body (calcium or other matters). Research has showed that development of muscle tissues makes the skeleton stronger. This fact should be taken into account when making up a diet and calculating physical activity to maintain the bones strong and healthy. Bone mass (BON) practically doesn’t change; how­ever, some decrease is possible due to many factors (weight, height, age, sex). That’s why this manual does not contain standard values and recommenda­tions concerning the bone mass.
Recommended level of daily calorie intake (KCAL)
The level of daily calorie intake (KCAL) is the amount of energy required by a human body at rest to main­tain its vital functions (for instance, if you merely stay in bed for 24 hours). The required amount of calories significantly depends on the weight, height and age of a person. This amount of calories is required by the human body and it should be regained by means of food. If you receive less calories for a long time, it may harm your health.
and medium- and long-term changes are caused by changes in the amount of fat and muscle bulk.
For instance, short-term weight loss and simul­taneous growth or constant amount of fat in body tissues may be caused by decreased amount of liquid as a result of physical exercises, visiting sauna or may happen at quick weight loss.
Medium-term increase of weight, decrease of fat amount or constant fat amount in body tissues may be caused by increase of muscle bulk.
If you notice simultaneous decrease of total weight and fat percentage, it means that your diet works.
The best results are achieved if you combine diet with various physical exercises, in this case you can observe the medium-term increase of muscle mass in body tissues.
CLEANING AND CARE
Clean the scale with a soft, slightly damp cloth and then wipe it dry.
Never use abrasives or solvents.
Never immerse the unit into water or other liquids.
Keep the scale away from children in a dry cool place.
DELIVERY SET
1.
Scale – 1 pc.
2.
«AAA» batteries - 2 pcs.
3.
Instruction manual – 1 pc.
TECHNICAL SPECIFICATIONS
Power supply: 2 «AAA» type batteries, 2 x 1,5 V Maximum weight: 150 kg.
The manufacturer reserves the right to change the design and the specifications of the unit without a preliminary notification
Analysis of weighing results
Unit operating life is 3 years
As a rule, short-term changes of weight within several days are the result of minor loss of liquid in your body tissues. Analyze the results of regular weight measure­ments taken throughout a long time. Evaluation of the results is based on changes of total weight and tissue percentage and depends on the duration of the period within which the measurements have been taken.
Guarantee
Details regarding guarantee conditions can be ob­tained from the dealer from whom the appliance was purchased. The bill of sale or receipt must be pro­duced when making any claim under the terms of
this guarantee. Short-term indication changes during a day can be significantly different from the indication changes within a week or a month. As a rule, short-term indication changes are con­nected with percentage of liquid in body tissues,
This product conforms to the EMC­Requirements as laid down by the Council Directive 2004/108/ЕС and to the Low Voltage Regulation (2006/95/ЕС)
6
VT-1984.indd 6 07.05.2014 17:22:00
D E U T S C H
PERSONENWAAGE VT-1984
Die Waage ist zur Messung der Körpermasse, sowie zur Feststellung des Gehalts von Fett, Wasser, Knochen- und Muskelgeweben im menschlichen Körper bestimmt.
Im diesem Waagenmodell wurde das Prinzip der bioelektrischen Analyse des Scheinwiderstands des Körpers (der Impedanz) «BIA» verwendet, das sehr genaue Berechnung des Prozentgehaltes von Fett-, Muskel- und Knochengeweben, sowie Wasser, ermöglicht. Die Berechnungen werden mit Rücksicht auf die gespeicher­ten Personenangaben (Körperhöhe, Alter, Geschlecht) ausgeführt.
BESCHREIBUNG
1.
Plattform
2.
Kontaktflächen
3.
Bildschirm
4.
Sensortasten der Datenwahl «/»
5.
Sensortaste der Wahl und Bestätigung der Dateneingabe «SET»
6.
Wahltaste der Gewichtseinheiten «UNIT»
7.
Batteriefachdeckel
BETRIEBSANLEITUNG ACHTUNG!
Vor der ersten Inbetriebnahme des Geräts lesen Sie diese Bedienungsanleitung aufmerksam durch und bewahren Sie diese für weitere Referenz auf. Benutzen Sie das Gerät nur bestimmungsmäßig und laut dieser Bedienungsanleitung. Nicht ord­nungsgemäße Nutzung des Geräts kann zu seiner Störung führen, einen gesundheitlichen oder mate­riellen Schaden beim Nutzer hervorrufen.
VORSICHTSMAßNAHMEN
Die Verwendung der Funktion des Übergewichtanalysators ist den Schwangeren ABSOLUT kontraindiziert.
Die Verwendung der Funktion des Übergewichtanalysators ist den Personen, die Herzschrittmacher oder übrige medizinische Geräte mit eingebauten Einspeiseelementen haben, ABSOLUT kon­traindiziert.
Gehen Sie mit der Waage wie mit jedem Meßgerät vorsichtig um, setzen Sie die Waage hohen oder niedrigen Temperaturen, erhöhten Feuchtigkeit, direkten Sonnenstrahlen nicht aus und lassen Sie die Waage nicht fallen.
Verwenden Sie die Waage fern von Heizgeräten.
Achten Sie darauf, dass keine Flüssigkeit ins Waagegehäuse eindringt, dieses Gerät ist nicht wasserdicht. Es ist nicht gestattet, die Waage in den Räumen mit erhöhter Feuchtigkeit (mehr als 80%) zu lassen oder zu benutzen, ver­meiden Sie den Kontakt des Waagegehäuses mit Wasser oder anderen Flüssigkeiten, um die Korrektheit der Waagenangaben nicht zu stören oder den Ausfall der Waage zu vermei­den.
Stellen Sie die Waage auf einer ebenen, trocke­nen und rutschfesten Oberfläche auf.
Die Waagenangaben werden präziser sein, wenn Sie die Waage nicht auf Teppichen oder Teppichböden verwenden.
Es ist nicht gestattet, mit nassen Füssen auf die Waage oder auf die nasse Oberfläche der Waage zu treten, sonst können Sie rutschen und sich verletzen.
Seien Sie vorsichtig, wenn Sie auf die Waage tre­ten: treten Sie zuerst auf die Waage mit einem Fuß, vergewissern Sie sich, dass die Waage standfest ist, erst dann treten Sie mit dem ande­ren Fuß.
Treten Sie auf die Waage und verteilen Sie Ihr Gewicht gleichmäßig. Während des Abwiegens bewegen Sie sich nicht. Es ist nicht gestattet, auf der Oberfläche der Waage zu springen.
Falls Sie die Waage längere Zeit nicht benut­zen werden, nehmen Sie die Batterien aus dem Batteriefach heraus.
Beim Einsetzen der Batterien beachten Sie die Polarität streng entsprechend den Bezeichnungen.
Ersetzen Sie die Batterien rechtzeitig.
Dieses Gerät ist nicht für den Gebrauch von Kindern unter 8 Jahren geeignet.
Dieses Gerät ist nicht für Personen (darun­ter auch Kinder über 8 Jahren) mit Körper-, Nerven- und Geistesstörungen oder ohne aus­reichende Erfahrung und Kenntnisse geeignet. Das Gerät darf von solchen Personen nur dann genutzt werden, wenn Sie sich unter Aufsicht der Person befinden, die für ihre Sicherheit ver­antwortlich ist, und wenn ihnen entsprechende und verständliche Anweisungen über sichere Nutzung des Geräts und die Gefahren bei seiner falschen Nutzung gegeben wurden.
Beaufsichtigen Sie Kinder, damit sie das Gerät als Spielzeug nicht benutzen.
Aus Kindersicherheitsgründen lassen Sie die Plastiktüten, die als Verpackung verwendet wer­den, nie ohne Aufsicht.
7
VT-1984.indd 7 07.05.2014 17:22:00
DEUTSCH
Achtung! Lassen Sie Kinder mit Plastiktüten oder Verpackungsfolien nicht spielen. Erstickungsgefahr!
Um Beschädigungen zu vermeiden, transportie­ren Sie das Gerät nur in der Fabrikverpackung.
Es ist nicht gestattet, die Waage selbständig zu reparieren.
Falls Sie Fragen über die Geräteunterhaltung haben, wenden Sie sich bitte an einen autori­sierten (bevollmächtigten) Kundendienst.
Bewahren Sie das Gerät an einem für Kinder und behinderte Personen unzugänglichen Ort auf.
DAS GERÄT IST NUR FÜR DEN GEBRAUCH IM HAUSHALT GEEIGNET
WICHTIG Elektromagnetische Verträglichkeit
Die elektronische Waage kann gegen elek­tromagnetische Ausstrahlung von anderen Geräten (wie Mobiltelefonen, Kleinfunkgeräten, Radioschaltpulten und Mikrowellenöfen), die sich in der Nähe befinden, empfindlich sein. Falls die Merkmale solcher Einwirkung erscheinen (falsche oder einander widersprechende Angaben auf dem Bildschirm), verwenden Sie die Waage fern von der Störquelle.
VOR DER ERSTEN INBETRIEBNAHME
Falls das Gerät unter niedrigen Temperaturen transportiert oder aufbewahrt wurde, lassen Sie es bei der Raumtemperatur nicht weniger als zwei Stunden bleiben.
Falls vorhanden, entfernen Sie die Schutzfolie von der Oberfläche der Waage.
Wischen Sie die Waage mit einem weichen, leicht angefeuchteten Tuch, danach trocknen Sie sie ab.
EINSETZEN UND ERSETZEN DER BATTERIE
Machen Sie den Batteriefachdeckel (7) auf und setzen Sie 2 «AAA»-Batterien (mitgeliefert) ein, beachten Sie dabei die Polarität streng.
Stellen Sie den Batteriefachdeckel (7) zurück auf.
Anmerkung: Falls es eine Isolierbeilage im Batteriefach gibt, machen Sie den Batteriefachdeckel (7) auf, entfernen Sie die Isolierbeilage und stellen Sie den Deckel zurück auf.
Ersetzen der Batterie
Bei der Batterieentladung wird das Symbol «Lo» auf dem Bildschirm (3) angezeigt.
Machen Sie den Batteriefachdeckel (7) auf, ersetzen Sie die Batterien mit neuen «AAA»­Batterien, beachten Sie dabei die Polarität streng, und machen Sie den Deckel (7) zu.
Falls die Waage längere Zeit nicht gebraucht wird, nehmen Sie die Batterien aus dem Batteriefach heraus.
WAS IST DAS ÜBERGEWICHT?
Es ist allgemein bekannt, dass das Übergewicht die Gesundheit negativ beeinflussen kann. Das Übergewicht kann Fettleibigkeit, Entstehung von Herzproblemen, Entwicklung von Atherosklerose und Osteoporose verursachen, aber das Mangelgewicht kann auch zur Osteoporose füh­ren (Osteoporose ist eine Systemerkrankung des Gerippes, die durch Reduzierung der Knochenfestigkeit und durch Störung der Mikroarchitektonik des Knochengewebes gekennzeichnet ist und zur Steigerung der Knochenbrüchigkeit und zum Knochenbruchrisiko wegen eines kleinsten Traumas oder sogar ohne Trauma führt). Das Übergewicht kann mit Hilfe von Körperübungen und einer gemäßigten Diät besiegt werden, und diese Waage hilft Ihr Gewicht zu kontrollieren. Es ist bekannt, dass bei einem niedrigen Gewicht Muskeln und Körpergewebe mehr Wasser als Fett enthalten. Der Strom läuft besser durch das Wasser als durch das Fett. Indem die Waage einen schwachen Strom durch Ihren Körper fließen lässt, wird der Gehalt von Fett und Wasser im mensch­lichen Körper ganz leicht und schnell gemessen. Aufgrund der Ergebnisse von Berechnung können Sie Ihr Gewicht kontrollieren.
EMPFEHLUNGEN
Wiegen Sie sich immer in derselben Tageszeit.
Messen Sie den Fett- und Wasserprozentgehalt am Abend vor dem Abendessen.
Es sollen nicht weniger als 2-3 Stunden nach der Mahlzeit vergehen.
Nach intensiven Körperübungen sollen nicht weniger als 10-12 Stunden vergehen.
Das Prozentgehalt von Fett im Körper hängt von verschiedenen Faktoren ab und kann sich wäh­rend des Tages ändern.
Bei der Berechnung des Fett- und Wasserprozentgehalts bei den Kindern jün­ger als 10 Jahre können ungenaue Ergebnisse erhalten werden.
Die Ergebnisse der Berechnung können bei Profisportlern, Ödem-anfälligen Personen und
8
VT-1984.indd 8 07.05.2014 17:22:00
D E U T S C H
Menschen mit abnormer Körperproportion ungenau sein.
Anmerkung: Die Angaben des Gehalts von Fett-, Knochen-, Muskelgeweben und Wasser können nur dann berechnet werden, wenn Sie richtige Personenangaben (Geschlecht, Alter, Körperhöhe) eingegeben haben und auch wenn Sie auf der Waage barfuß stehen.
EINSCHALTUNG
Stellen Sie die Waage auf eine gerade, feste Oberfläche auf, ein unebener oder mit Teppich oder Teppichbelag bedeckter Fußboden kann die Meßgenauigkeit reduzieren.
Die Waage wird eingeschaltet, wenn eine Last von mehr als 5 kg auf die Plattform gestellt wird oder wenn die Taste «SET» (5) berührt wird.
WAHL DER GEWICHTSEINHEITEN
Schalten Sie die Waage auf eine der obener­wähnten Weisen ein.
Zur Wahl der Gewichtseinheiten drücken Sie die Taste (6) «UNIT» aufeinanderfolgend.
Die Gewichtseinheiten werden auf dem Bildschirm (3) angezeigt:
«kg» – Gewichtsmessung in Kilogramm; «lb» – Gewichtsmessung in Pfund; «st:lb» – Gewichtsmessung in Stone und Pfund.
ABWIEGEN
Zum Einschalten der Waage treten Sie darauf.
Halten Sie Ihre Füße parallel und verteilen Sie das Körpergewicht gleichmäßig.
Bleiben Sie während des Abwiegens unbewegt. Während des Abwiegens werden blinkende Gewichtswerte auf dem Bildschirm (3) ange­zeigt, danach werden die Gewichtsangaben ständig angezeigt.
Achtung!
Wenn das Symbol «Err» auf dem Bildschirm (3) angezeigt wurde, ist die Waage über­lastet. Gehen Sie sofort von der Waage hinunter, um ihre Beschädigung zu ver­meiden.
Die Waage schaltet sich ungefähr 10 Sekunden nach dem Abwiegen automa­tisch aus.
EINGABE DER PERSÖNLICHEN DATEN (Abb. 1)
Berühren Sie die Taste (5) «SET», auf dem Bildschirm (3) wird die blinkende Nummer eines von den Benutzern «P-01», «P-02».., «P-12» angezeigt.
Wählen Sie die Nummer des Benutzers mittels der Tasten (4) «/». Die Eingabe der Angabe ist für 12 Benutzer möglich. Bestätigen Sie die Wahl mittels der Taste «SET» (5).
Dann wird auf dem Bildschirm das blinkende Symbol des Geschlechts angezeigt. Wählen Sie das Symbol
für Frauen oder für Männer mit-
tels der Tasten (4) «/». Bestätigen Sie die Wahl durch das Drücken der Taste (5) «SET».
Dann werden auf dem Bildschirm blinkende Werte der Körperhöhe in Zentimetern ange­zeigt. Stellen Sie die Körperhöhe im Bereich von 100 bis 220 cm mittels der Tasten (4) «/» ein und bestätigen Sie die Einstellungen durch das Drücken der Taste (5) «SET».
Die Alterswerte (age) werden auf dem Bildschirm blinken. Stellen Sie das Alter im Bereich von 10 bis 80 Jahre mittels der Tasten (4) «/» ein. Um die Altersangaben zu speichern, berühren Sie die Taste (5) «SET».
Dann wird auf dem Bildschirm der Nullgewichtswert «0.0» angezeigt, das heißt, die Waage ist für die Berechnung Ihrer Kennwerte bereit.
BERECHNUNG DES PROZENTGEHALTES VON FETT-, KNOCHEN-, MUSKELGEWEBEN UND WASSER IM MENSCHLICHEN KÖRPER
Berühren Sie die Taste (5) «SET».
Wählen Sie die Nummer des Benutzers mittels der Tasten (4) «/». Die vorher eingegebenen Benutzerangaben (Geschlecht, Körperhöhe, Alter) werden auf dem Bildschirm angezeigt.
Warten Sie ab, bis die Symbole «0.0» auf dem Bildschirm erscheinen.
Treten Sie auf die Waage barfuß auf solche Weise, dass sich beide Fußsohlen auf den Kontaktflächen (2) gleichzeitig befinden. Während des Abwiegens bewegen Sie sich nicht und warten Sie ab, bis die Gewichtsangaben angezeigt werden.
Bleiben Sie auf der Waage stehen. Nach der Berechnung werden folgende Angaben auf dem Bildschirm (3) angezeigt: der Gehalt von Fett (FAT), Wasser (BW), Knochen (BON) und Muskeln (MUS), sowie der empfohlene tägliche Bedarf an Kalorien (KCAL).
Das Gewicht und die Messergebnisse werden noch mehrmals angezeigt, dann schaltet sich das Gerät automatisch aus.
Anmerkung: Vor der Messung des Gehalts von Fett, Wasser usw. geben Sie die Personenangaben in den Speicher des Geräts UNBEDINGT ein.
9
VT-1984.indd 9 07.05.2014 17:22:00