IMPORTANT SAFETY WARNINGS
SAVE THESE INSTRUCTIONS.
WARNING:
WARNING:
Children should not use spas or hot tubs without adult supervision.
Before entering the spa or hot tub measure the water temperature with an accurate thermometer.
ENGLISHFRANÇAIS
WARNING:
Do not use spas or hot tubs unless all suction guards are installed to prevent body and hair entrapment.
WARNING: People using medications and/or having an adverse medical history should consult a physician before using a spa or hot tub.
WARNING: People with infectious diseases should not use a spa or hot tub.
WARNING: To avoid injury, exercise care when entering or exiting the spa or hot tub.
WARNING: Do not use drugs or alcohol before or during the use of a spa or hot tub to avoid unconsciousness and possible drowning.
WARNING: Pregnant, or possibly pregnant, women should consult a physician before using a spa or hot tub.
WARNING: Do not use a spa or hot tub immediately following strenuous exercise.
WARNING: Prolonged immersion in a spa or hot tub may be injurious to your health.
WARNING: Do not permit electric appliances (such as a light, telephone, radio, or television) within
1.5m of the spa or hot tub.
WARNING: Maintain water chemistry in accordance with manufacturer’s instruction.
WARNING: The use of alcohol or drugs can greatly increase the risk of fatal hyperthermia in hot tubs and spas.
WARNING: Water temperature in excess of 104° F or 40° C may be injurious to your health.
VITA SPA
1
Page 2
TABLE OF CONTENTS
ENGLISH FRANÇAIS
GFCI Alert 1 Important Safety Warnings 2
Table of Contents 3
Important Safety Instructions 5
Do’s and Don’ts 6 Hyperthermia 7
Spa installation 8
Site and Positioning 8 Outdoor Installation 8 Indoor Installation 8 Water Capacity 8
Spa System Components 10
Spa Components 11
Jets, Air Controls & Valves 12
Jets 12 Cleaning or Replacing Jets 12 Air Controls 13 On / O - Diverter Valve 13 Cleaning or Replacing Valves 13
Electrical Information 14
Important Safety Instructions 14 Ground Fault Circuit Interupter 14 Installation Options 14
Start Up Procedures 16 Priming Your Spa 16 Pr Message 16
Powerworks® 167 Control System 17
Operating Instructions 17 User’s Pads 18 Temperature Controls 18
Jet Operation 18 Standard/Economy/Sleep Modes 19 Filtration Cycles 19 Preset Filter Cycles 19 Changing Filter Cycle Duration 19 Light 20 Panel Messages 43 Troublershooting 43 Ozone Operation 37 Entertainment System (Optional) 34
Powerworks® 460 Control System 21 Powerworks® 760 Control System 22
User’s Pads 23 Temperature Controls 23 Jet Operation 23 Temperature Lock 24 Temperature Unlock 24 Panel Lock 24 Panel Unlock 24 Light 24 Standard/Economy/Sleep Modes 24 Changing Modes 25 Setting the Time 25 Preset Filter Cycles 25 Changing Filter Cycle 26 Clean Up Cycle 26 Inversion Features 27 Ozone Operation 37 Entertainment System (Optional) 34
Powerworks® 504 Control System 28 User’s Pads 29 Temperature 29 Jet Operation 29 Light 30 Operating Modes 30 Standard/Economy/Sleep Modes 30 Preset Filter Cycles 30
2
VITA SPA
Page 3
Changing Filter Cycles 31 Clean Up Cycle 31 Automatic time Outs 31
Light Bulbs 41 Spa Cover Care 41 Thermal Creep 42
Options and Features 32
AquaBurst Lighting System 32 Blower / Champagne Air System 32 VitaRoma Aromatherapy System 32 Circulation (Circ) Pump 33 Inversion Feature 33 Entertainment System 34 Therapy Sequencer Control 35 Therapy Sequencer Program Chart 35 Starting the Sequencer 36 Sequencing Programs 36 Sequencing Speeds 36 Sequencer Pausing 36 SequencerUser Pad 36
Safety Features
Automatic Time Outs (165 & 167) 20 Automatic Time Outs (460 &760) 34 Automatic Time Outs (504) 33 Common LCD Messages (165 &167) 43 Common LCD Messages (460, 504, 760) 43
Maintenance 37
Water Chemistry 37 Sanitizing 37 pH Level 37 Sanitizing With Ozone 37 Specialty Chemicals 38 Draining Your Spa 38 Filter Maintenance 39 Winterizing 39 Spa Cabinet Care 41 Spa Surface Care and Cleaning 41
Panel Messages 43 Common Water Problems 47 Common Hardware Problems 50 Spa Soaking Guidelines 52 167 Series System Wiring Diagram 53 460 Series System Wiring Diagram 54 504 Series System Wiring Diagram 55 760 Series System Wiring Diagram 56
Safety sign 57
Limited warranty summary 57
Copyrights and trademarks 58
Notes 59
ENGLISHFRANÇAIS
VITA SPA
3
Page 4
IMPORTANT SAFETY INSTRUCTIONS
ENGLISH FRANÇAIS
1. READ AND FOLLOW ALL
INSTRUCTIONS
2. WARNING - To reduce the risk of injury, do not permit children to use this prod­ uct unless they are closely supervised at all times.
3. A wire connector is provided on this unit to connect a minimum 6 AWG (5.15 mm solid copper conductor between this unit and any metal equipment, metal enclosu­ res of electrical equipment, metal water pipe, or conduit within 5 feet (1.5m) of the unit.
4. (For cord-connected/convertible units) DANGER - Risk of injury. a. Replace damaged cord immedi­ ately. b. Do not bury cord. c. Connect to a grounded, ground­ ing type receptacle only.
5. DANGER - Risk of Accidental Drown­ ing. Extreme caution must be exercised to prevent unauthorized access by children. To avoid accidents, ensure that children cannot use this spa unless they are supervised at all times.
6. DANGER - Risk of injury. The suction  ttings in this spa are sized to match the speci c water  ow created by the pump. Should the need arise to replace the suction  ttings or the pump, be sure that the  ow rates are compatible.
Never operate spa if the suction  ttings
are broken or missing. Never replace a suction  tting with one rated less than the  ow rate marked on the original suc­ tion  tting.
7. DANGER - Risk of Electric Shock. Install at least 5 feet (1.5m) from all metal surfaces. As an alternative, a spa may be installed within 5 feet of metal surfaces if each
2
metal surface is permanently connected
)
by a minimum 6 AWG (5.15 mm copper conductor to the wire connector on the terminal box that is provided for this purpose.
8. DANGER - Risk of Electric Shock. Do not permit any electric appliance, such as a light, telephone, radio, or television, within 5 feet (1.5m) of a spa.
9. WARNING - To reduce the risk of injury: a. The water in a spa should never exceed 40°C (104°F). Water tem- peratures between 38°C (100°F) and 104°F (40°C) are considered safe for a healthy adult. Lower water temperatures are recommended for young children and when spa use exceeds 10 minutes. b. Since excessive water temperatures have a high potential for causing fetal damage during the early months of preg­ nancy, pregnant or possibly pregnant women should limit spa water tempera­ tures to 38°C (100°F). c. Before entering a spa the user should measure the water temperature since the tolerance of water temperature-regulat­ ing devices varies. d. The use of alcohol, drugs, or medica-
2
) solid
4
VITA SPA
Page 5
tion before or during spa use may lead to unconsciousness with the possibility of drowning. e. Obese persons and persons with a history of heart disease, low or high blood pressure, circulatory system prob­ lems, or diabetes should consult a physi­ cian before using a spa.
10.
SAVE THESE
INSTRUCTIONS
NOTE: Check with your state/local code enforcement o cer to determine electrical code requirements and compliance. Use a quali ed licensed electrician to complete all spa  nal electric connections.
Caution: Risk of electrical shock. Read and follow all instructions.
TO AVOID RISK OF ELECTRICAL SHOCK:
1. A green colored terminal or a terminal marked G, GR, Ground, Grounding, or the international symbol is located on the side of the supply terminal box or compartment. This terminal must be connected to the grounding means provided in the electric supply service panel, using a continuous copper wire equivalent in size to the circuit conductors supplying this equipment.
*IEC Publication 417, Symbol 5019.
2. At least two lugs marked “BONDING LUGS” are provided on the external sur­ face or on the inside of the supply termi­ nal box or compartment. Connect the local common bonding grid (house-hold ground) in the area of the hot tub or spa to these terminals, using an insulated or bare copper conductor not smaller than No. 6 AWG.
3. All  eld-installed metal components such as rails, ladders, drains or similar hard ware located within 5 ft. of the spa or hot tub shall be bonded to the equip­ ment grounding bus with copper con­ ductors not smaller than No. 6 AWG.
4. Never connect unit to a power supply with a load controller.
5. Install to provide drainage of compart­ ment for electrical components.
6. The electrical supply for this product must include a suitably rated switch or circuit breaker to open all ungrounded supply conductors. This disconnecting means must be readily accessible for operation but installed at least 1.5m from the spa. All electrical connections should comply with local regulations.
Do’s and Don’ts
For years of spa enjoyment:
Do:
• Save these instructions!
• Replace the cover immediately after use.
•
Keep the cover locked when spa is not in use.
• Be aware of the dangers of a wet and slippery surface. Use caution when entering and exiting your spa.
• Have a licensed electrician make all  nal electrical connections.
•
Replace worn, frayed or broken electrical cords.
• Keep the water chemistry correctly balanced. Untreated spa water will cause problems with your spa and equipment as well as being a health risk.
• Clean the spa  lter monthly or as needed.
• Position the spa so that all sides remain
ENGLISHFRANÇAIS
VITA SPA
5
Page 6
accessible for maintenance.
• Use a bathing cap for long hair.
ENGLISH FRANÇAIS
• Refer to information on hyperthermia, next page.
• Use only authorized spa care products for the best performance and to keep the water properly balanced.
Don’t:
• Use the spa at 104°F (40°C) for long periods of time (more than 30 minutes). See Hyperthermia, below.
• Use an extension cord to power your spa.
• Allow anyone to stand on the spa cover. It is not designed to support weight.
• Power the spa unless it is  lled with water to 1/8” below the top of the Weir door.
• Operate the pump on high speed for ex­ tended periods of time with the cover in place. Extended operation can cause heat build-up and interfere with spa operation.
Hyperthermia
The causes, symptoms, and e ects of hyperthermia may be described as follows: Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6°F (37°C). The symptoms of hyperthermia include an increase in the internal temperature of the body, dizziness, lethargy, drowsiness, and fainting. The e ects of hyperthermia include: a. Failure to perceive heat b. Failure to recognize the need to exit spa or hot tub c. Unawareness of impending hazard d. Fetal damage in pregnant women e. Physical inability to exit the spa or hot tub, and f. Unconsciousness resulting in the danger of drowning. WARNING  The use of alcohol, drugs, or medication can greatly increase the risk of fatal hyperthermia.
6
VITA SPA
Page 7
SPA INSTALLATION
Danger: Electrical shock risk. Install at
least 1.5m from all metal surfaces.
The electrical supply for this product must include a suitably rated switch or circuit breaker to open all ungrounded supply conductors. This disconnecting means must be readily accessible for operation but installed at least 1.5m from the spa. All electrical connections should comply with local codes and regulations.
The appliance should be supplied through a residual current device (RCD) with a rated tripping current not exceeding 30 mA. Means for disconnection must be incorporated in the  xed wiring in accordance with the wiring rules. Parts containing live parts, except parts supplied with safety extra-low voltage not exceeding 12 V, must be inaccessible to a person in the bath. Earthed appliances must be permanently connected to  xed wiring.
Site and Positioning
Locate the spa on solid, level foundation or  ooring, keeping in mind the weight of the  lled spa [in excess of some models]. If you have any doubts about the load bearing ability of your chosen site, contact an architect or a building contractor. The entire perimeter of the spa cabinet and the spa bottom must be evenly supported. If your spa is installed outdoors, we recommend that you provide a concrete pad for the spa to rest on 8ft x 8ft x 4in (2,5m x 2,5m x 10cm level pad). Failure to provide
a  at level surface could structurally
4,000 bls. (1.800 kg.)
on
damage your spa and void the warranty.
The spa must be installed to allow access for service and maintenance on all four sides; therefore, below grade level installation is not recommended.
Outdoor Installation
The following considerations apply when installing your spa outdoors:
1. Local codes pertaining to fencing.
2. Local electrical and plumbing codes.
3. View from your house.
4. Wind direction.
5. Exposure to sunlight.
6. Location relationship to trees (twigs, leaves and shade).
7. Dressing and bathroom location.
8. Storage area for maintenance equipment and chemicals.
9. Location to facilitate adult supervision.
10. Landscaping and nighttime lighting.
11. Accessibility to equipment.
12. Power supply location and foot tra c.
Indoor Installation
The following considerations apply when installing your spa indoors:
1. Indoor spas promote high humidity. Using either ventilation fans or commercial grade de-humidi ers will help to reduce the humidity. Consult your dealer for details.
2. Floor drains must be provided near the spa to drain o water that may cause falls and /or water damage.
3. Floor area should be  at with a non-skid  nish. Carpeting is not recommended.
4. Walls, ceilings, woodwork should be made of materials capable of withstanding high
ENGLISHFRANÇAIS
VITA SPA
7
Page 8
ENGLISH FRANÇAIS
humidity (redwood, cedar).
5. Be sure  oor load bearing capacities are adequate to support the concentrated spa weight.
6. Spas should be double checked for leaks before installing to avoid possible water damage. Dealer installation may include this service.
7. Indoor sun rooms are capable of maintaining high ambient temperatures which may e ect the spa water temperature. It is NOT recommended that you operate your  lter cycles for longer than 4 hours per day under these conditions.
SEE THERMAL CREEP: page 42
MODEL GALLONS LITERS JOLI 260 985 CABARET 470 1,781 NUAGE 465 1,762 PASSION 130 492 PROTÉGÉ 365 1,382 CHATEAU 360 1,360 RENDEZVOUS 510 1,933 MYSTIQUE 545 2,063 AMOUR 130 493 IMAGE 280 1058 INTRIGUE 375 1417 ELEGANT 375 1417 MONARQUE 350 1323 PRESTIGE 350 1323 ENVIE 500 1323 GRAND 550 2079 DUET 103 530
8
VITA SPA
Page 9
SPA SYSTEM COMPONENTS
A
B
E
H
A. Filter Skimmer/Weir Door: Removes  oating debris from the water surface, provides a water return path to equipment, and houses water  lter element.
B. Topside Control Panel: Used to control temperature setting, pump for jets, and light.
C. Air Controls: Increases or decreases air entering the jets. Close during heating for maximum e ciency.
C
G. AquaBurst Lighting: Lighting system that displays multiple colored lights in pre-programmed random, solid or alternating colours (not shown).
H. Manufacturer’s Identi cation Label: Contains identi cation information
for warranty service (serial number, model number, etc.) and electrical information (ampere rating and ampere requirements).
J. Wave Seat : Ultimate relaxation seat.
J
I
F
ENGLISHFRANÇAIS
E. Equipment Pack Service Panel (no user serviceable parts): Spa support system
consisting of pump(s), heater, optional blower and associated electrical controls (not shown).
F. Drain Access: (Adjacent to the equipment service panel) Spa drain faucets.
VITA SPA
K. Stereo/Speakers (not shown).
L. Sequencer Controls (not shown).
9
Page 10
SPA COMPONENTS
ENGLISH FRANÇAIS
Reference only. Equipment is not always as shown
A. Pumps (one or more pumps, depending on model): Low speed for
e cient water circulation during  ltration and heating; high speed for maximum action of the jets. The pump functions are activated by topside controls. Circ Pump – Continuous Filtration – See Circ Pump details on pg 31
B. Warning and Installation Label: Contains important safety information
and installation instructions.
C. Slice Valve: Used to shut o water  ow from the spa to the equipment while servicing. Quantity will vary depending on model. All should be open during normal operations.
10
D. Spa Pack: Houses the electronic circuit
board. All equipment and incoming power connections are made here .
E. Heater Assembly: Thermostatically controlled and equipped with an overheat safety shut-o .
Note: No consumer serviceable parts. Do NOT attempt to service any of these components yourself. Contact your dealer for assistance.
VITA SPA
Page 11
JETS, AIR CONTROLS & VALVES
Jets All spa jets are individually engineered to provide a unique hydro-massage. Depending on the model, your spa will have a combination of the following jets:
Directional Therapeutic (200, 300, and 400 Series Wave Style): Positioned to focus on large muscle groups, these jets deliver a concentrated, high volume stream of water for a deep massage. Each jet is fully adjustable, allowing users to set the water  ow to the most comfortable setting. The nozzle can be rotated to target sore muscle areas.
Note: Ozone production is suspended when other functions are activated on the control panel by the spa user.
NOTE: In spas equiped with a circ pump the ozonator can not be shut o and will remain on as long as the circ pump is running.
Many full sized jets are adjustable from a fully open to closed position. It is very important that you NEVER SHUT ALL FULL SIZED JETS OFF AT ONE TIME! WHEN EXITING THE SPA, OPEN ALL CLOSED JETS.
ENGLISHFRANÇAIS
Rotational or Spinning Jets (200, 300, and 400 Series Wave Style): Positioned to focus on muscle tension zones, these jets deliver a spinning water stream for a gentle, pulsating massage. Each jet is fully adjustable, allowing users to set the water  ow to the most comfortable setting.
Swim Jet( non-adjustable): Positioned to create overall water circulation, this multi-purpose, high volume jet provides whirlpool action throughout the entire spa.
Euro Jets: Positioned in the foot well or shoulder areas of the spa, these jets deliver a penetrating massage to dissolve tension. This jet may be the entry point for ozone produced during the automatic  ltration cycles, and, as such, is not adjustable.
VITA SPA
Cleaning or Replacing Jets
Hard water can cause calcium/mineral buildup that can restrict or bind the jets. A jet consists of a face plate and a nozzle. Rotate these parts weekly and remove/clean monthly to ensure free movement.
NOTE: It is not necessary to drain the spa to clean or remove the jets.
Rotating the jet face plate and nozzle
• Rotate the jet face left and right (open and closed).
• Return the face plate to the full open position.
• Turn the jets on to high speed.
• Twist the nozzle left and right.
• Rotate the nozzle in the socket.
NOTE: If the jet insert disengages from the spa housing, see steps to reinstall below.
11
Page 12
Cleaning the jets
ENGLISH FRANÇAIS
To remove the jet insert, use the palm of your hand to exert pressure on the face of the jet. Turn counterclockwise until the jet ‘clicks’. Gently pull the jet assembly from the housing.
To clean the jet insert and housing, use a pressurized hose and spray the inside of the jet housing. Soak the jet in a diluted spa cleaning solution, rinse. Wipe the inside of the housing to remove any debris.
To reinstall the jet, line up the tab on the backside of the barrel with the groove in the body. Use the palm of your hand to gently tap the jet until it snaps into position.
Air Controls
The intensity of the jet action can be controlled by altering the amount of air injected with water through the jets. Your spa has 2 to 4 air controls located on the lip of the spa. Each control activates air to speci c jets in the spa allowing you to create various combinations and levels of jet action to suit individual preferences. Turn the control counter- clockwise to turn the air o and clockwise to turn air on.
On / O Valve: Turns on or shuts o the  ow of water to multiple jets or the waterfall.
Diverter Valve: Diverts water from one set of jets to another. The diverter valve should be tested weekly to clean the lines and to help prevent debris from building up.
NOTE: The diverter and on / o valve(s) should
be cleaned regularly. Power spa o at the breaker or disconnect. Remove the handle by pulling upward and rocking it back and forth, unscrew the cap and pull the valve stem out. To clean the valve stem and housing use a pressurized hose and spray the inside of the valve housing. Soak the valve stem in a diluted spa cleaning solution, rinse. Wipe the inside of the housing to remove any debris.
WARNING: Never operate spa while valve caps are removed. Valve should be fully assembled before supplying power to the equipment.
NOTE: Air controls should be closed during heating cycles for maximum energy e ciency.
NOTE: At the start of a  ltration cycle, the Champagne Air System is activated to purge the lines and ensure complete  ltration. Ensure that at least one air control is always fully open.
12
VITA SPA
Page 13
ELECTRICAL INFORMATION
Caution: Risk of electrical shock. Read and follow all instructions.
Important Safety Instructions
All electrical connections to this spa package MUST be accomplished by a quali ed licensed electrician in accordance with local electrical codes in e ect at the time of installation.
NOTE: Prior to performing any service to the spa equipment, turn OFF all primary electrical power at the main circuit breaker or disconnect panel.
To make spa electrical connections, remove the exterior equipment access panel, locate the electrical control box, remove the control box cover and follow the wiring diagram on the inside of the control box cover. Connections should be made using copper conductors only. Connecting wires, circuit breakers, or fuses must all be sized to accommodate the Total Ampere load as speci ed on the equipment label. This equipment is designed to operate on 50Hz alternating current only, at 230 volts.
NOTE: All unions must be hand-tight and all slice valves must be locked in the OPEN position before  lling or re lling spa! A clip is provided to help keep the slice valve open. Run spa and check for union water leaks before reinstalling exterior panel.
Important Safety Instructions
All electrical connections to this spa package MUST be accomplished by a quali ed licensed electrician in accordance with locall codes in e ect at the time of installation.
NOTE: Prior to performing any service to the spa equipment, turn OFF all primary electrical power at the main circuit breaker or disconnect panel.
Note: Copper wire is strongly recommended for all electrical connections.
ENGLISHFRANÇAIS
VITA SPA
13
Page 14
START UP PROCEDURES
ENGLISH FRANÇAIS
Follow recommendations for site location and electrical connection. The water line on the weir door is the level at which the water should be maintained.
1. Fill the spa through the  lter hole to 1/8” below the top of the Weir door. with tap water. Never use ‘softened’ water in your spa. Softened water can impact the chemical balance of the water and lead to degradation of metal plumbing  ttings.
2. Turn power on to unit at circuit breaker or disconnect panel.
3. Open the air controls, located on the top lip, and cycle the jets from high to low. Water should come from the therapy jets. If water  ow is not established, turn o jets and see Priming Your Spa (this page).
4. Add chemicals. Ask your dealer for additional information.on start up or getting the water balanced.
Priming Your Spa When  lling your spa for the  rst time or, after draining and re lling the spa, you may need to bleed air from the system. Should you experience an air-lock on Pump 1, remove the  lter cover, insert a garden hose through each center hole that holds the  lter as far as possible without using force. Hold the hose in place and turn on the water. Cycle pump 1 from low to high several times, this forces water into the pump and forces the air out. If this does not work or you experience an air-lock on Pump 2, remove the side panel and locate the pump. With the pump on high speed, slowly loosen the discharge (top) pump union until water starts to trickle out. Once water is trickling out, hand tighten the union (do not over tighten as this could cause the union to crack) and replace the side panel
Follow Operating Instructions for your particular model to set heat to the desired temperature. Initially, you may  nd that the spa requires 12 to 14 hours on 230 Volt installations to reach temperature. Keep your thermal cover on the unit and close the air controls to help the heating process.
NOTE: At the start of a  ltration cycle, the Air System is activated to purge the lines and ensure complete  ltration. If you have the air system ensure that at least one air control is always fully open.
Important: Do not operate the spa
without full water  ow.
14
Pr - This is Not an Error Message The Spa has just been powered up and is in Priming Mode for 4 Minutes. Pumps can be turned ON and OFF to remove any air from the plumbing lines and the Heater. Cycle the pumps on and o to verify good water  ow and wait 4 minutes or press any temp related button to exit Priming Mode.
VITA SPA
Page 15
POWERWORKS ® 167 CONTROL
Amour, Image, Intrigue & Duet
ENGLISHFRANÇAIS
If your Topside Control looks like this, your spa has the following features:
• Internal Light
• 1 Dual Speed Pump
If your Topside Control looks like this, your spa has the following features:
• Internal Light
• 1 Dual Speed Pump
• Champagne Air System
The 167 Series Powerworks™ Controls o er you the ultimate in spa control. The backlit, Liquid Crystal Display (LCD) displays current temperature, set water temperature, and operating mode settings. Each feature is actuated through the control panel pad. Touch the appropriate button to activate the desired function.
NOTE: The CIRC PUMP option will change the operation of the factory default settings and modes of operation of your spa. All  ltration and heating is now controlled by the CIRC PUMP. If your spa has a CIRC PUMP see speci c CIRC PUMP information on page 31
VITA SPA
At start up, when power is supplied to the spa, the controls will operate properly and safely under the factory settings. The spa will be in Standard mode, have a temperature setting of 100°F (38°C), and a  ltration cycle duration of 2 hours. To fully utilize the unique capabilities of the control system, it is important to know how to set the temperature, operate the pumps, operate the light, adjust the mode setting, and change the  ltration cycle.
15
Page 16
User’s Pads
User’s Pads are the buttons located on the
ENGLISH FRANÇAIS
topside control panel and are used to program various spa functions (i.e., turn on spa light, set temperature, etc.). The following table de nes the buttons:
Pad Use
• Decrease temperature
• Increase temperature
Temp
• Switch modes
• Change  ler cycle durations
• Turn internal spa light on or o
• Switch modes
Lght
• Activate therapy pump
• Set duration of  lter cycles
Jets
• Activate Champagne Air
System
Air
Temperature
The maximum set temperature is 104°F (40°C) and the minimum set temperature is 80°F (26°C). The current water temperature or, if the pump has not been running, two dashes, will show on the display. If dashes are displayed, you must  rst start the pump by pressing the PUMP 1 pad. Wait until the water temperature is displayed (approximately 2 minutes).
The set temperature of your spa may easily be increased or decreased at any time using the ‘TEMP’ pad. Press the ‘TEMP’ pad; the set temperature will be displayed in the LCD window. The next touch of ‘TEMP’ will change the set temperature either up or down 1°F (0,5°C). If you want to increase the temperature and the displayed indicates the temperature was increased by 1°F (0,5°C), continue to press the ‘TEMP’ pad until the desired set temperature is reached.
If you want to decrease the set temperature and the LCD indicates that the temperature is increasing, STOP. Wait a few seconds until the actual temperature is displayed. Then press the ‘TEMP’ pad again. The set temperature will be displayed. Press it again and the set temperature will decrease by 1°F (0,5°C). Continue pressing the ‘TEMP’ pad until the desired set temperature is reached.
If the spa is set in Standard mode or in a  ltration cycle, increasing the set temperature may result in activating the heater. Decreasing the set temperature will turn the heater o . When the heater is operating, the LED below the ‘HEAT’ icon will be lit.
Pump 1
Touch the ‘JETS’ pad to activate the primary  ltration pump. The sequence of the jet action is: 1 touch = Low therapy jets 2 touches = High therapy jets 3 touches = O
The low speed operation of Pump 1 is timed to automatically turn o after two hours of operation. The high speed operation of Pump 1 is timed to automatically turn o after 30 minutes of operation.
16
VITA SPA
Page 17
NOTE: With the standard con guration, pump 1 will automatically operate in low speed whenever the spa calls for a  ltration cycle or heat. When this automatic activation occurs, the low speed of Pump 1 cannot be turned o ; however, all other control functions can be activated.
MODES OF OPERATION:
In the standard con guration (NO circ pump option) your spa can be switched among Standard, Economy, and Sleep modes by touching the ‘TEMP’ pad and then the ‘LIGHT’ pad. If your spa is in the Standard mode, the low speed of Pump 1 and the heater will come on automatically to maintain the set temperature of the water. The pump will circulate for approximately two minutes several times throughout the day to sample water temperature. If your spa is set in the
Economy mode,
the heater will operate ONLY during the  ltration cycles. If your spa is set in the
Sleep mode,
The spa will heat to within 20°F (11°C) of the set temperature only during  lter cycles. The pump will operate either during a normal  ltration cycle or, the heater and pump will be activated when the heater housing temperature drops below 45°F (7.2°C). The selected mode will be displayed in the LCD window of the control panel. When in Standard mode, the letters ‘ST’ are displayed beie y, followed by the water temperature. When in Economy mode, the letters ‘EC’ are
displayed alternately with the water temperature. When in Sleep mode, the letters ‘SL’ are displayed alternately with the water temperature.
Setting the Time and Filtration Cycles
You can decide when your  lter cycles start and you also have choices on how long they run.
ENGLISHFRANÇAIS
Preset Filter Cycles. The spa control system
is designed with two  lter cycles. The  rst  lter cycle turns on 6 minutes after power is supplied to the spa. The second  lter cycle turns on 12 hours later. Filter cycles are pre-set for a two hour duration.
Note: To properly clean and maintain spa, a total  lter time of at least four hours per day is recommended. If an ozonator is installed, 6 hours is recommended.
Changing Filter Cycle Start Time
The start/stop times of the  lter cycle begin 6 minutes after the spa set time is established. Set time is based on the time of day that the spa is powered up. Set time may only be changed by disconnecting power from the spa and re-connecting it at the desired start time. For example, if you want the  lter cycle to begin at 9:00 PM,turn o the spa breaker and turn it back on at 8:54 PM (remember the 6 minute wait period). The cycle will begin at 9:00 PM and will repeat beginning at 9:00 AM. Each cycle will run for the prescribed number of hours.
Changing Filter Cycle Duration
The duration of a  lter cycle can be set in hour increments of 2, 4, 6, 8, or continuous. For example, a 2 hour cycle will complete once every 12 hours for a total of 4 hours per day. The amount of time needed to  lter you spa will depend on usage and ambient conditions. You will need to program you  lter cycles based upon your personal use. To change the duration of the  lter cycles
VITA SPA
17
Page 18
touch the ‘TEMP’ pad and then touch the
Accessory Mode Shuts o in...
‘J ET S’ pad. Touch the ‘TEMP’ pad to adjust
ENGLISH FRANÇAIS
the cycle duration to the desired setting. After each press, the duration of the cycle will be displayed in the LCD window as follows:
F2 2 Hours for each cycle, 4 hours per day F4 4 Hours for each cycle, 8 hours per day F6 6 Hours for each cycle, 12 hours per day F8 8 hours for each cycle, 16 hours per day FC Continuous  ltration, 24 hours per day
To exit the  lter-set procedure, touch ‘JETS’. The LCD window will display the current water temperature. If a change is made to the duration while the spa is in a  ltration cycle, it will take e ect immediately. If the change is made outside a  ltration cycle, it will take e ect at the start of the next scheduled cycle.
NOTE: When power to the spa is denied (disconnect, power outage), the controls may revert to the default factory settings. Any adjustments to set temperature or  lter cycle duration may need to be reprogrammed.
Light
Touch the ‘LIGHT’ pad to turn all lights on and o . The lights will automatically turn o after 4 hours of operation.
Automatic Time Outs
Your Vita Spa is equipped with an automatic Time Out feature designed to protect both the equipment and the user. To reduce unneces­sary use of the pumps and lights, the Time Out feature turns selected accessories o autmatically.
Accessory Mode Shuts o in... Blower 30 minutes Pump 1 Low 2 hours Pump 1 High 30 minutes Pump 2 High / Low 30 minutes Circ Pump Never Light 4 hours
THERMAL CREEP: see page 40
OZONE OPTION: see page 35
VITAROMA OPTION: see page 30
CIRC PUMP OPTION: see page 33
ENTERTAINMENT SYSTEM OPTION: see page 32
CHAMPAGNE AIR SYSTEM OPTION: see page 30
AQUABURST LIGHTING SYSTEM OPTION: see
page 30
18
VITA SPA
Page 19
POWERWORKS ® 460E CONTROL
460E Series Control System for Spa Models Joli, Cabaret, Nuage, Passion, Chateau
If your Topside Control looks like this, your spa has the following features:
• Internal Lights
• Champagne Air System
• 2 Pumps
If your Topside Control looks like this, your spa has the following features:
• Internal Lights
• 2 Pumps
ENGLISHFRANÇAIS
The 460 Control System o ers you the ultimate in spa control. The backlit, Liquid Crystal Display (LCD) displays current water temperature, set point water temperature, time, and operating mode settings. Each feature of the system is actuated through a control panel touch pad. Touch the appropriate pad to activate the desired function. NOTE: The CIRC PUMP option will change the operation of the factory default settings and modes of operation of your spa. All  ltration and heating is now controlled by the CIRC PUMP. If your spa has a CIRC PUMP see speci c CIRC PUMP information on page 31.
VITA SPA
At start up, when power is supplied to the spa, the controls will operate properly and safely under the factory settings. The spa will be in Standard Mode, have a temperature setting of 100°F (38°C), and a  ltration cycle duration of 2 hours. To fully utilize the unique capabilities of the control system, it is important to know how to set the temperature, operate the pumps, operate the light, adjust the mode setting, and change the  ltration cycles.
Note: In event of a power outage or failure, the 460 Series Control System may retain settings. If settings are lost, re-program per the instructions in this manual.
19
Page 20
POWERWORKS ® 760E CONTROL
ENGLISH FRANÇAIS
760E Series Control System for spa models Rendezvus and Mystique
If your Topside Control looks like this, your spa has the following feature:
If your Topside Control looks like this, your spa has the following features:
• Internal Lights
• Blower
• 2 Dual Speed Pumps
If your Topside Control looks like this, your spa has the following features:
• Internal Lights
• 2 Dual Speed Pumps
The Powerworks™ 760 Series Control System o ers you the ultimate in spa control. The backlit, Liquid Crystal Display (LCD) displays current water temperature, set point water temperature, time, and operating mode settings. Each feature of the system is actuated through a control panel touch pad. Touch the appropriate pad to activate the desired function. At start up, when power is supplied to the spa, the controls will operate properly and safely under the factory settings. The spa will be in
Standard mode, have a temperature setting of
20
• 1 Additional Single Speed Pump
100°F (38°C), and a  ltration cycle duration of 2 hours. To fully utilize the unique capabilities of the control system, it is important to know how to set the temperature, operate the pumps, operate the light, adjust the mode setting, and change the  ltration cycles.
Note: In event of a power outage or failure, the 760 Series Control System may retain setngs. If settings are lost, re-program per the instructions in this manual.
VITA SPA
Page 21
User’s Pads
User’s Pads are the buttons located on the topside control panel and are used to program various spa functions (i.e., turn on spa light, set temperature, etc.). The following table de nes the pads:
Pad Use
• Increase temperature
UP
Down
Time
• Change time settings
• Used in alternate programming sequences
• Decrease temperature
• Change time settings
• Used in alternate programming sequences
• Used in alternate programming sequences
• Exit programming
• View the Time
• Switch modes
• Set time and  ltration cycles
Prog
• Turn all spa light on or o
Light
• Activate Champagne Air
Air
Jets 1
System
• Activate primary pump
•Used in alternate programming sequances
Temperature
The maximum set temperature is 104°F (40°C) and the minimum set temperature is 80°F (26°C). The current water temperature or, if the pump has not been running, two or three dashes, will show on the display. If dashes are displayed, you must  rst start the pump by pressing the ‘JETS 1’ pad. Wait until the water temperature is displayed (approximately 2 minutes). The set temperature of your spa may easily be increased or decreased at any time using the ‘UP’ or ‘DOWN’ pads. When either of these pads is touched, the set temperature will be displayed in the LCD window. Each successive touch will change the set temperature 1°F (0,5°C) in the chosen direction. After 3 seconds the LCD will automatically display the water temperature or dash lines. If the spa is set in Standard mode or in a  ltration cycle, adjusting the set temperature may result in activating the heater. When the heater is operating, the heat icon will be displayed in the LCD.
JETS 1
Touch the ‘JETS 1’ pad to activate the primary  ltration pump. The sequence of the jet action is: 1 touch = Low therapy jets 2 touches = High therapy jets 3 touches = O
JETS 2
Touch the ‘JETS 2’ pad to activate the therapy pump. The sequence of jet action is: 1 touch = Low therapy jets 2 touches = High therapy jets 3 touches = O
ENGLISHFRANÇAIS
• Activate therapy pump
Jets 2
VITA SPA
21
Page 22
JETS 3 Touch the ‘JETS 3’ pad to activate the therapy
ENGLISH FRANÇAIS
pump in conjunction with the sequencer. The sequence of jet action is: 1 touch = High therapy jets 2 touches = O
The low speed operation of Pump 1 is timed to automatically turn o after two hours of operation. The high speed operation of Pump 1 and the low and high speed of Pumps 2 & 3, are timed to automatically turn o after 15 minutes of operation.
The low speed of Pump 1 runs when the blower or any other pump is on. In the STANDARD mode it will also activate for at least 2 minutes every 30 minutes to detect the spa water temperature and then remain on to heat to the set temperature if needed. When this automatic activation occurs, the low speed of Pump 1 cannot be turned o ; however, all other control functions can be activated.
Light
Touch the ‘LIGHT’ pad to turn all lights on and o . The lights will automatically turn o after 4 hours of operation.
Spa Control Locks The corresponding lights on the spa panel will illuminate to show the spa control locks or  lter cycles that are currently active.
Temperature Lock (TL)
Once you have set the desired water temperature, you may lock-in the new setting to prevent unauthorized temperature adjustments to your spa. To lock the set temperature: Touch ‘UP’ or ‘DOWN’, then touch ‘TIME’, ‘JETS 1’ and ‘UP’
within 3 seconds. The ‘TL’ indicator will light when the set temperature is locked.
Temperature Unlock
To unlock the temperature, touch either ‘UP’ or ‘DOWN’, then touch ‘TIME’, ‘JETS 1’, and ‘DOWN’ within 3 seconds. The ‘TL’ indicator light will go out when the set temperature lock is cleared.
Panel Lock (PL)
To help prevent unauthorized use of your spa, the control system has a unique panel locking system. To lock the panel, touch ‘TIME’, ‘JETS 1’, then ‘UP’ within 3 seconds. When locked, the ‘PL’ indicator light will be on. Except for the time button, everything will be frozen. When the control panel lock is engaged, all automatic spa functions will operate normally but cannot be altered.
Panel Unlock To unlock the panel, touch the ‘TIME’, ‘JETS 1’, and ‘DOWN’ within 3 seconds.
The ‘PL’ indicator light will go out when the panel lock is cleared.
Operating Modes
Your Vita Spa comes with three primary operating modes.
Standard Mode maintains the water at the desired set temperature. Note that the last measured spa temperature displayed is current only when the pump has been running for at least 2 minutes. The ‘STD’ icon will be brie y displayed in the LCD window when this mode is selected. The word standard will constantly be displayed on the panel
Economy Mode heats the water to the
22
VITA SPA
Page 23
desired set temperature ONLY during  lter cycles. The ‘ECN’ icon may be displayed in the LCD window and the word economy will be displayed on the panel when this mode is selected. While in the Economy mode, pressing the ‘JETS 1 ’ button will put the spa into the Standard-In-Economy mode, which operates the same as the Standard Mode, then reverts back to the Economy mode after 1 hour. The spa can be immediately reverted back into the Economy mode at any time by simply pressing the ‘PROG’ button.
Sleep Mode heats the spa to within 20°F (11°C) of the set temperature only during  lter cycles. The ‘SLP’ icon may be displayed in the LCD window and the word sleep will be displayed on the panel when this mode is selected.
Standby Mode: While in this mode, all spa functions are temporarily suspended to allow for  lter changes or other routine maintenance tasks.
take full advantage of the unique capabilities of your new spa, you should  rst set the time and establish your  ltration cycles.
Setting the Time
When the time of day has not been programmed, the icon will be  ashing on the LCD window. To set the time of day,  rst press the ‘TIME’ button then press the ‘PROG’ button. The hour digit(s) will be  ashing on the LCD window. Press the ‘UP’ or ‘DOWN’ button to advance the hours up or down to the desired set point. Press the ‘PROG’ button to enter the time hour. The minute digits will now be  ashing on the LCD window. Press the ‘UP’ or ‘DOWN’ button to advance the minutes up or down to the desired set point. Press the ‘PROG’ button to enter the time minutes. At this point you can either proceed with setting the  ltration cycles as described in the following ‘Changing Filter Cycle’ section, or press the ‘TIME’ button to save the settings and exit the programming sequence.
ENGLISHFRANÇAIS
Changing Modes
To change the operating mode, press the ‘PROG’ button. The operating mode will be  ashing on the LCD window. Press the ‘DOWN’ button to cycle through to the desired mode, and then press the ‘PROG’ button to con rm selection. Pressing
Pressing ‘UP’ or ‘DOWN’ then ‘JETS2’ will put the spa into the Standby Mode. Press any button to exit the Standby mode.
Time and Filtration Cycles
The control system on your spa has been designed to function properly and safely at 104F (40°C) after connecting the electrical wires and installing the proper grounds. To
VITA SPA
Preset Filter Cycles
Once the time of day has been set, your spa will automatically  lter the water for a 2-hour period every 12 hours. The  rst  lter cycle comes preset to operate from 8:00AM to 10:00AM, and the second  lter cycle comes preset to operate from 8:00PM to 10:00PM. The F1 indicator light will be lit whenever the spa is in the  rst  lter cycle. The F2 indicator light will be lit whenever the spa is in the second  lter cycle. During a  lter cycle, the primary  ltration pump will operate in low speed and can not be turned o unless the spa is put into the Standby mode. At the beginning of each  ltration cycle, the other equipment in the spa will turn on for 30 seconds to purge all
23
Page 24
plumbing lines and ensure complete  ltration.
ENGLISH FRANÇAIS
Changing Filter Cycles
The control system allows you to adjust the start time and duration of each  lter cycle independently to best suit your schedule. The amount of time needed to  lter your spa will vary depending upon usage and ambient conditions, but a total  lter time of at least four hours per day is recommended to properly clean and maintain the water.
To initiate the programming sequence to change the  lter cycles, press ‘TIME’, ‘PROG’, ‘PROG’, and ‘PROG’ within 3 seconds.
If you are setting the  lter cycles as a continuance from setting the time then proceed to the next paragraph.
press ‘PROG’
You should now see the ‘PROGRAM’, ‘FILTER 1’, and ‘START TIME’ icons on the LCD display window. The hour digit(s) will be  ashing on the LCD window. Press the ‘UP’ or ‘DOWN’ button to advance the hours up or down to the desired set point. Press the ‘PROG’ button to enter the time hour. The minute digits will now be  ashing on the LCD window. Press the ‘UP’ or ‘DOWN’ button to advance the minutes up or down to the desired set point. Press the ‘PROG’ button to enter the time minutes. You should now see the ‘PROGRAM’, ‘FILTER 1’, and ‘END TIME’ icons on the LCD display window. Adjust the hours and minutes for the end time of the  rst  lter cycle as described above. After pressing the ‘PROG’ button to enter the end time of the  rst  lter cycle, you should now see the ‘PROGRAM’, ‘FILTER 2’,
and ‘START TIME’ icons on the LCD display window. Adjust the hours and minutes for the start time of the second  lter cycle as described above. After pressing the ‘PROG’ button to enter the start time of the second  lter cycle, you should now see the ‘PROGRAM’, ‘FILTER 2’, and ‘END TIME’ icons on the LCD display window. Adjust the hours and minutes for the start time of the second  lter cycle as described above. After pressing the ‘PROG’ button to enter the end time of the  lter cycle, the new  ltration times will be saved into the system and the LCD window will revert back to display the current water temperature. Pressing the ‘TIME’ button at any time during the above programming sequence will save the values entered up to that point and exit the programming sequence. To set the spa for continuous  ltration, set the start and end times of the  rst  lter cycle to the exact same time.
Note: To properly clean and maintain spa, a total  lter time of at least four hours per day is recommended. If an ozonator is installed, 6 hours is recommended.
Clean Up Cycle
After periods of heavy use, you can manually start a clean-up cycle by turning Pump 1 on in low speed. The pump will operate for 2 hours and then automatically turn o . The heater will also operate during this period if the controls are set in the Standard mode.
NOTE: Activating the low speed of Pump 1 for a clean-up cycle will initiate  ltration, but not ozone production, unless the spa enters a timed  lter cycle during the 2 hour period.
24
VITA SPA
Page 25
Inversion Feature
The Control System includes an Inversion feature that makes it easy to read the LCD from inside or outside the spa. To invert the LCD display, touch the ‘UP’ or ‘DOWN’ button, followed by the ‘AIR’ button. Repeat the sequence to reverse the inversion process. If your spa is not equipped with the optional Champagne Air feature, locate the position of the AIR button (next to the LIGHT button) and press in that general location
Automatic Time Outs
Your Vita Spa is equipped with an automatic Time Out feature designed to protect both the equipment and the user. To reduce unneces­sary use of the pumps and lights, the Time Out feature turns selected accessories o autmatically.
Accessory Mode Shuts o in... Blower 15 minutes Pump 1 Low 2 hours Pump 1 High 15 minutes Pump 2 Lo / Hi 15 minutes Pump 3 High 15 minutes Circ Pump Never Light 1 hour
THERMAL CREEP: see page 40
OZONE OPTION: see page 35
VITAROMA OPTION: see page 30
CIRC PUMP OPTION: see page 33
ENTERTAINMENT SYSTEM OPTION: see page 32
CHAMPAGNE AIR SYSTEM OPTION: see page 30
AQUABURST LIGHTING SYSTEM OPTION: see
page 30
THERAPY SEQUANCER : see page 33
ENGLISHFRANÇAIS
VITA SPA
25
Page 26
POWERWORKS ® 504 CONTROL SYSTEM
ENGLISH FRANÇAIS
Intrigue, Elegant, Monarque, Prestigue, Envie, & Grand
If your Topside Control looks like this, your spa has the following features:
• Internal Lights
• 1 Dual Speed Pump
• 1 Single Speed Pump
If your Topside Control looks like this, your spa has the following features:
• Internal Lights
• Blower / Champagne
Air System
• 1 Dual Speed Pump
• 1 Single Speed Pump
The Powerworks™ 504 Series Control System o ers you the ultimate in spa control. The backlit, Liquid Crystal Display (LCD) displays current water temperature, set point water temperature and operating mode settings. Each feature of the system is actuated through a control panel touch pad. Touch the appropriate pad to activate the desired function. At start up, when power is supplied to the spa, the controls will operate properly and safely under the factory settings. The spa will be in
Standard mode, have a temperature setting of
26
100°F (38°C), and a  ltration cycle duration of 2 hours. To fully utilize the unique capabilities of the control system, it is important to know how to set the temperature, operate the pumps, operate the light, adjust the mode setting, and change the  ltration cycles.
Note: In event of a power outage or failure, the 504 Series Control System may retain settings. If settings are lost, re-program per the instructions in this manual.
VITA SPA
Page 27
User’s Pads
User’s Pads are the buttons located on the topside control panel and are used to program various spa functions (i.e., turn on spa light, set temperature, etc.). The following table de nes the pads:
Pad Use
• Increase temperature
• Change time settings
Up
Down
•Used in alternate programming sequences
• Decrease temperature
• Change time settings
•Used in alternate programming sequences
• Switch modes
Prog
• Turn internal spa light on or o
Light
• Activate Champagne Air
Air
Jets 1
System
• Activate primary  ltration pump
•Used in alternate programming sequences
• Activate therapy pump
Jets 2
Temperature
The maximum set temperature is 104°F (40°C) and the minimum set temperature is 80°F (26°C). The current water temperature or, if the pump has not been running, two dashes, will show on the display. If dashes are displayed, you must  rst start the pump by pressing the ‘JETS 1’ pad. Wait until the water temperature is displayed (approximately 2 minutes). The set temperature of your spa may easily be increased or decreased at any time using the ‘UP’ or ‘DOWN’ pads. When either of these pads is touched, the set temperature will be displayed in the LCD window. Each successive touch will change the set temperature 1°F (0.5°C) in the chosen direction. After 3 seconds the LCD will automatically display the water temperature or dash lines. If the spa is set in Standard mode or in a  ltration cycle, adjusting the set temperature may result in activating the heater. When the heater is operating, the heat icon will be displayed in the LCD.
Note: 230-Volt spas that are wired with the low Amp option will not heat when Pump 1 is on in high speed, or when Pump 2 is in operation.
JETS 1
Touch the ‘JETS 1’ pad to activate the primary  ltration pump. The sequence of the jet action is: 1 touch = Low jets 2 touches = High jets 3 touches = O
JETS 2
Touch the ‘JETS 2’ pad to activate the therapy pump. The sequence of jet action is: 1 touch = High jets 2 touches = O
ENGLISHFRANÇAIS
VITA SPA
27
Page 28
The low speed operation of Pump 1 is timed to automatically turn o after 4 hours of
ENGLISH FRANÇAIS
operation. The high speed operation of Pumps 1 & 2 and the low speed of pump 1 are timed to automatically turn o after 15 minutes of operation.
NOTE (NON-Circ Pump Systems): The low speed of Pump 1 runs when the blower or any other pump is on. In the STANDARD mode it will also activate for at least 2 minutes every 30 minutes to detect the spa water temperature and then remain on to heat to the set temperature if needed. When this automatic activation occurs, the low speed of Pump 1 cannot be turned o ; however, all other control functions can be activated.
Light
Touch the ‘LIGHT’ pad to turn all lights on and o . The lights will automatically turn o after 4 hours of operation.
Changing Modes
To change the operating mode, press the ‘UP’ or ‘DOWN’ and the press the ‘PROG’ button. The operating mode will be  ashing on the LCD window. Press the ‘DOWN’ button to cycle through to the desired mode.
Time and Filtration Cycles
The control system on your spa has been designed to function properly and safely at 100°F (38°C) after connecting the electrical wires and installing the proper grounds. To take full advantage of the unique capabilities of your new spa, you should  rst set the time and establish your  ltration cycles.
Preset Filter Cycles
The spa control system is designed with two  lter cycles. The  rst  lter cycle turns on 6 minutes after power is supplied to the spa. The second  lter cycle begins 12 hours later. Filter cycles are pre-set for a two hour duration.
Operating Modes
Your Vita Spa comes with three primary operating modes. Standard Mode maintains the water at the desired set temperature. Note that the last measured spa temperature displayed is current only when the pump has been running for at least 2 minutes. The ‘STD’ icon will be brie y displayed in the LCD window when this mode is selected. Economy Mode heats the water to the desired set temperature ONLY during  lter cycles. The ‘ECN’ icon will be displayed in the LCD window when this mode is selected. Sleep Mode heats the spa to within 20°F (-6.6°C) of the set temperature only during  lter cycles. The ‘SLP’ icon will be displayed in the LCD window when this mode is selected.
28
Note: To properly clean and maintain spa, a total  lter time of at least four hours per day is recommended. If an ozonator is installed 6 hours is recommended.
Changing Filter Cycle Start Time
The start/stop times of the  lter cycle begin 6 minutes after the spa set time is established. Set time is based on the time of day that the spa is powered up. Set time may only be changed by disconnecting power from the spa and reconnecting it at the desired start time. For example, if you want the  lter cycle to begin at 9:00 PM, turn o the breaker or disconnect the spa and reconnect it at 8:54 PM (remember the 6 minute wait period). The cycle will begin at 9:00 PM and will repeat beginning at 9:00 AM. Each cycle will run for
VITA SPA
Page 29
the prescribed number of hours.
Changing Filter Cycle Duration
The duration of a  lter cycle can be set in hour increments of 2, 4, 6, 8, or continuous. For example, a 2 hour cycle will complete once every 12 hours for a total of 4 hours per day. The amount of time needed to  lter your spa will depend on usage and ambient conditions. You will need to program your  lter cycles based upon your personal use.
To change the duration of the  lter cycles press the ‘UP’ or ‘DOWN’ button and then touch the ‘JETS 1’.
Press the ‘UP’ or ‘DOWN’ button to adjust the cycle duration to the desired setting. After each press, the duration of the cycle will be displayed in the LED window as follows:
FIL2 = 2 Hours for each cycle, 4 hours per day FIL4 = 4 Hours for each cycle, 8 hours per day FIL6 = 6 Hours for each cycle, 12 hours per day FIL8 = 8 hours for each cycle, 16 hours per day FILC = Continuous  ltration, 24 hours per day
NOTE: At the start of each  lter cycle all equipment is activated for 5 minutes or less to clear the water in the pipes and ensure complete  ltration.
Clean Up Cycle
After periods of heavy use, turn “PUMP 1” on for a four-hour clean up cycle.
Automatic Time Outs
Your Vita Spa is equipped with an automatic Time Out feature designed to protect both the equipment and the user. For your safety and to reduce unnecessary use of the pumps and lights, the Time Out feature turns selected accessories o automatically, as follows:
Accessory Mode Shuts O In...
Accessory Mode Shuts o in... Pump 1 Low 4 hours
Pump 1 High 15 minutes Pump 2 High 15 minutes Blower 15 minutes DOL Light 4 hour
ENGLISHFRANÇAIS
To exit the  lter-set procedure, touch ‘JETS 1’. The LCD window will display the current water temperature.
If a change is made to the duration while the spa is in a  ltration cycle, it will take e ect immediately. If the change is made outside a  ltration cycle, it will take e ect at the start of the next scheduled cycle.
VITA SPA
THERMAL CREEP: see page 40
OZONE OPTION: see page 35
VITAROMA OPTION: see page 30
CIRC PUMP OPTION: see page 33
ENTERTAINMENT SYSTEM OPTION: see page 32
CHAMPAGNE AIR SYSTEM OPTION: see page 30
AQUABURST LIGHTING SYSTEM OPTION: see
page 30
29
Page 30
OPTIONS & FEATURES
ENGLISH FRANÇAIS
AquaBurst Lighting
For the Vita Spa that is equipped with a AquaBurst Lighting System. This system has di erent color settings (sequences) to enhance your overall spa experience. Each time the AquaBurst system is turned ON by pressing the ‘LIGHT’ pad, it will begin a color lighting sequence.
Accessing Di erent Light Sequences To change Sequences, press the ‘LIGHT’
button O and On within a 5 second time period. The light will advance to the next color sequence mode. Continue until the desired color sequence mode is selected. The sequence will revert to the  rst sequence each time the light is turned o for more than 5 seconds.
When cycling through colors on the control panel, this is the program sequence for the AquaBurst lighting system.
1. Color-Wheel. This mode transitions the di erent colors.
2. White (All LEDs On).
3. Aqua (Green & Blue)
4. Purple (Red & Blue)
5. Blue
6. Amber (Red & Green)
7. Green
8. Red
9. Color Flash. This mode switches colors every few seconds.
10. Strobe. This mode  ashes the LEDs on and o like a strobe light.
performance and therapeutic action of the jets. To turn the Air or Champagne Air system on and o , touch the ‘AIR’ button.
NOTE: The Champagne Air System will shut o automatically after 15 minutes.
NOTE: At the start of a  ltration cycle, the Champagne Air System is activated to purge the lines and ensure complete  ltration. Ensure that at least one air control is always fully open.
VitAroma / AROMATHERAPY SYSTEM
VitAroma Therapy o ers the unique bene ts of combining Aroma and Hydrotherapy. Simply de ned, aromatherapy is the practice of using pure essential oils – the highly concentrated extracts of plants, herbs and  owers – to improve one’s feelings of well being through the acute sense of smell
Your spa is equipped with an aroma
dispenser located on the lip of the spa. VitAroma is standard on Spa Models Joli, Cabaret, Nuage, Passion, Chateau and Mystique. It will operate whenever Pump 1 is operated and will involve opening the air controls. On Spa Models Amour, Intrigue, Elegant, Monarque, Prestigue, Envie, and Grand the the VitAroma Induction System is an option that can be activated by touching the AIR button. You will immediately experience the wonder and pleasure of aromatherapy. It will soothe your senses and invigorate your spirit.
Air / Champagne Air System Option
Your spa may be optionally equipped with Air or Champagne Air system to increase the
30
VITA SPA
Page 31
OPTIONS & FEATURES
To activate VitAroma, insert one of the Vita Spa’s exclusive aromatherapy scents and turn on the VitAroma Induction System. In some models this will involve touching the AIR button in other models this will involve opening the air controls, contact your local Vita Spa dealer for speci c information on your spa.
To extend the lifespan of the VitAroma beads, it is recommended that they be removed from the spa and stored in the resealable packet after each use. VitAroma aromatherapy scents are available exclusively from Vita Spa Dealers.
CIRCULATION PUMP OR CIRC PUMP OPTION: Circulation pump (CIRC PUMP): 504 system
The circ pump may turn on immediately upon power up; the prime mode (Pr) does not apply to this feature. All other equipment will turn on brie y at the beginning of each  ltration cycle to purge the plumbing lines. If your spa is con gured with the circ pump option it is designed to run constantly  ltering the water. The circ pump will turn o when the water temperature is detected to be 3F above the set temperature to reduce overheat conditions. During the summer months or when the ambient air temperatures are above 90F it is important to monitor the water temperature to identify and manage potential thermal creep or overheat situations. See THERMAL CREEP on pg 40
Circulation pump (CIRC PUMP): 460 & 760 systems
The circ pump will turn on once you exit the the prime mode (Pr). All other equipment will turn on brie y at the beginning of each  ltration cycle to purge the plumbing lines. The circ pump operates continuously (24 hours) with the exception of turning o for 30 minutes when the water temperature reaches 3°F (1.5°C) above the set temperature (most likely to happen in warm climates). During the summer months or when the ambient air temperatures are above 90F it is important to monitor the water temperature to identify and manage potential thermal creep or overheat situations. See THERMAL CREEP on pg 40
The mode settings will now work with circ pump. When your spa is in the Standard mode the heater will turn on as needed to maintain the set temperature. When it is in the Economy Mode, the heater will only be activated during the programmed  ltration cycle time and will heat the water to the set temperature. In the Sleep mode the heater will only activate if the water temperature is 20°F (11°C) below the set temperature
Inversion Feature ( 460 & 760 systems )
The Control System includes an Inversion feature that makes it easy to read the LCD from inside or outside the spa. To invert the LCD display, touch the ‘UP’ or ‘DOWN’ button, followed by the ‘AIR’ button. Repeat the sequence to reverse the inversion process. If your spa is not equipped with the optional AIR feature, locate the position of the AIR button (next to the LIGHT button) and press in that general location
ENGLISHFRANÇAIS
VITA SPA
31
Page 32
OPTIONS & FEATURES
ENGLISH FRANÇAIS
Entertainment System (Optional) Certain models are equipped with an audio system designed to provide the ultimate spa entertainment experience. Power to the entertainment system is supplied at spa start-up so it is always ready for your enjoyment. Refer to the stereo Owner’s Manual included in the Vita Spas Owner’s pack for instruction on programming and using the entertainment system. Read all instructions carefully before using the entertainment system and SAVE THE INSTRUCTIONS. The system includes a wireless remote. To operate the wireless remote, point it at the side skirt panel of the spa where the stereo is located. Note: The wireless remote control is water resistant, not waterproof. Do not submerge the wireless remote control. It is not recommended to use the wireless remote from within the spa.
CAUTION: Risk of electrical shock. Do not leave stereo compartment door open.
CAUTION: Risk of electrical shock. Replace components only with identical components.
a quali ed service technician.
WARNING: Prevent Electrocution.
Do not connect any auxiliary components (for example cable, additional speakers, headphones, additional audio/video components, etc.) to the system.
WARNING: Prevent Electrocution.
Do not service this product yourself as opening or removing covers may expose you to dangerous voltage or other risk of injury. Refer all servicing to quali ed personnel.
WARNING: Prevent Electrocution.
These units are not provided with an outdoor antenna. When provided it should be installed in accordance with Article 810 of the National Electric Code, ANSI/NFPA 70.
WARNING: Prevent Electrocution. This unit should be subjected to periodic routine maintenance (for example once every 3 months) to make sure the unit is operating properly.
CAUTION: Risk of electrical shock.
When the power supply connections or power supply cord(s) are damaged; if water is entering the electrical equipment compartment area; if the protective shields or barriers are showing signs of deterioration; or if there are signs of other potential damage to the unit, turn o the unit and refer servicing to
32
VITA SPA
Page 33
If your Control looks like this, your spa has the following features:
• Therapy Sequencer
ENGLISHFRANÇAIS
VITA SPA
33
Page 34
ENGLISH FRANÇAIS
Therapy Sequencer
Certain models are equipped with a Jet Sequencer System that opens and closes a series of four solenoid valves to provide a therapeutic sequencing massage. The control panel for the system allows you to start or stop operation, change programs, change speeds, or pause the system at any point in the program.
Starting the Sequencer
To energize the sequencing system, press the ‘JETS 3’ button on the topside control panel. Once energized, the sequencer will open all 4 solenoid valves and water will  ow through all open jets. Two dashed lines will be displayed in the LCD window. Push the ‘ON/OFF’ button one time and the LCD display will now show ‘On’. This indicates that the system has been activated, but no changes will occur until a sequencing program has been selected.
Sequencing Programs
To start the sequencing program, push the PROG button one time. The LCD will momentarily display ‘P2’, and then alternate between ‘P2’ and ‘S1‘’. The system is now running program 2 and sequencing speed 1. To change programs, push the ‘MODE/PROG’ button to step through the programs. The LCD will momentarily display the selected program (P3, P4, P5, etc.), and then alternately display the selected program with the sequencing speed. Refer to the Therapy Sequencer chart to see the order in which the valves will open and close for each program.
Sequencing Speeds
When  rst energized, the sequencing program will automatically go to the default speed, or ‘S1’. To change the sequencing speed, push the ‘SPEED’ button once. The LCD will momentarily display the selected speed (S1, S2, or S3), and then alternately display the current program and the sequencing speed.
Pausing
To pause the sequencing action of the system at any point, simply press the ‘PAUSE’ button. This will suspend the operation of the valves and hold them either until the sequence is resumed or until the system is de-energized. The LCD display will alternate between ‘PA’ and the current program number. Press the ‘PAUSE’ button again to resume normal operation.
Pad Use
• Activates the Sequencer
ON/OFF
• Navigates between the nine therapy sequencer programs
PROGRAM
• Navigates between the three therapy sequencer speeds
SPEEDS
• Pauses the therapy sequencer
PAUSE
34
VITA SPA
Page 35
MAINTENANCE
Water Chemistry
Water chemistry is critical in a spa system. Chemicals are used to sanitize the water and control the pH balance. The combination of high water temperature and small water volume means that the chemical balance must be watched carefully. It is recommended that you purchase a chemical start up kit, and the additional chemicals needed to maintain the proper/optimum chemical balance, from your dealer.
Sanitizing
Sanitizing the water destroys harmful organisms and keeps your spa healthy and safe. Three commonly used spa sanitizer or oxidizing agents are bromine, chlorine and ozone. Chlorine or bromine are chemicals that you add to the water. Ozone is a gas that is produced by an ozonator and injected into the water. It is important that a residual of sanitizer remain in your water. High water temperature, aeration and use will increase the need for sanitizer. In addition to maintaining a residual, it is important to ‘shock’ your spa water periodically and after heavy use. This addition of substantial amounts of sanitizer super­chlorinates the water and oxidizes non­ lterable organic residue. Allow the sanitizer level to drop back to the residual amount before using. Also use your Clean Up Cycle after heavy use for additional  ltration. Tests should be done daily with your test kit to keep a chlorine or bromine residual of 3.0 to 5.0 ppm.
pH Level
pH is the balance of acidity and alkalinity in the water. Maintaining proper pH is important for the e ectiveness of your sanitizer, for user comfort, and to prevent corrosion of the spa equipment.
Caution: Never mix two chemicals together. Caution: Never store chemicals in the
equipment compartment. Caution: Do not use muriatic acid to balance pH as it will damage your spa surface and equipment.
Recommended Levels
pH: 7.2–7.6 (Ideal 7.4–7.6) Sanitizer Residual: 3.5–5.0 ppm Total Dissolved Solids: 100–200 ppm Free Available Sanitizer: 3.0–5.0 ppm Total Alkalinity: 80–100 ppm ideal for dichlor, trichlor, and bromine
NOTE: Make sure you use fresh test kit strips/chemicals. Test kits and test chemicals should be stored in a cool, dry location. Check the manufacturer’s instructions to determine shelf life and expiration date.
Ozone:
Equipping your spa with the Powerworks ™ Ozonator is a smart decision. The use of ozone in conjunction with spa sanitizing and water balancing chemicals helps to provide you with a cleaner, healthier spa and reduces chemical usage.
ENGLISHFRANÇAIS
VITA SPA
35
Page 36
Sanitizing with Ozone
ENGLISH FRANÇAIS
Spas vary in size, as well as frequency and conditions of use. For this reason you will need to establish your sanitizing program based upon your own personal use. When using ozone, you should start by balancing your water chemistry as you normally would. A spa should run and be ozonated a minimum of six hours per day. If your spa is heavily used, this time should be increased. Your spa produces ozone during the  ltration cycles. The amount of a residual sanitizer (chlorine or bromine) that you maintain in the water will also vary depending on use. It is recommended that you maintain a residual of 3.0-5.0 ppm. Periodically, and after periods of heavy use, it is necessary to ‘shock’ your spa with large amounts of sanitizer.
Draining your Spa NOTE: Always turn the circuit breaker o when you drain your spa. Do not turn the spa heater back on until you have full  ow coming from the jets for several minutes..
Changing your spa water, cleaning the spa surface and  lter are necessary because high concentrations of impurities caused by water evaporation, body oils, perfumes, and other contaminants may accumulate in the spa that cannot be  ltered out.
NOTE: It is advisable to drain your spa and re ll it with fresh water every six to eight weeks or more often, depending on the amount of use.
NOTE: The ozonator is programed to turn on during a programed  lter cycle and will be disabled if any button other than the light is pushed durring this cycle.
NOTE: In spas equiped with a circ pump the ozonator can not be shut o and will remain on as long as the circ pump is running.
NOTE: Extra  ltration can be provided by manually starting a clean-up cycle. Turn Pump 1 on in low speed. The pump will operate for 2 - 4 hours (depending on spa system) and then automatically turn o .
Specialty Chemicals
While ozone may signi cantly reduce the usage of specialty chemicals it is not a substitute for these chemicals. All chemicals should continue to be monitored, especially during periods of heavy usage and when changing or replenishing the spa water.
36
All spas are equipped with both external and internal drains. The external drain is used for draining the spa. The internal drain(s) are used to remove water from internal hoses when winterizing your spa (See pg. 39) or if the water is severely contaminated.
NOTE: Use a standard garden hose to direct the water to an appropriate disposal area.
The external drain valve is located in a compartment on the front panel. Open the compartment, pull the valve out, remove the outer black cap and connect a garden hose to the  tting. Turn the ring on the back of the valve counter-clockwise until it stops, then pull out to open the valve. Water will begin to  ow. When  ow stops, push in the valve, turn ring clockwise until it stops, remove hose and replace the cap.
The internal drain hose(s) is (are) located behind the front access panel. Remove the
VITA SPA
Page 37
access panel screws and the access panel. Locate the drain hose(s). For each hose drain valve, remove the cap, attach the garden hose, and turn the valve body 90° counter­clockwise. Water will begin to  ow. When all water has been evacuated, turn the valve handle clockwise until it stops. Remove the garden hose and replace the cap. Repeat for each internal drain hose.
NOTE: Do NOT attempt to use the pump to drain the spa.
NOTE: Close all drain valves and replace caps prior to re lling the spa.
clockwise while lifting upwards.
5. Soak  lter in a commercial  lter cleaner/ degreaser, available from your Vita Spa dealer, per manufacturer’s instructions. Hose out  lter cartridge or replace with new cartridge, if needed.
6. Place  lter cartridge back into  lter canister, , screw in clockwise DO NOT OVER TIGHTEN.
7. Replace the skimmer lid.
8. Turn the pump ON.
Replacing the  lter cartridge annually is recommended to maintain optimum performance. Filter maintenance depends on usage.
ENGLISHFRANÇAIS
NOTE: When re lling the spa, you may need to bleed air from the system. Refer to Priming Your Spa, pg. 16 for instructions.
Filter Maintenance
NOTE: It is not necessary to drain the spa in order to clean the  lter.
The removable  lter cartridges are located in the  lter canister behind the weir door. The  lter should be inspected / cleaned monthly during normal use, and more often when spa use is heavy.
Keep the  lter cartridge clean! Clean the  lter cartridge at least once every 90 days. A clogged  lter decreases performance and degrades water quality.
To clean the  lter cartridge:
1. Turn the pump o .
2. Remove skimmer lid on top of spa.
4. Remove  lter cartridge from the  lter canister by grasping the top and unscrew counter-
Winterizing
In cold climates where freezing temperatures occur, special care is required to prevent the possibility of damage to the spa and equipment due to freezing. If you plan on using your spa during cold months, be sure your pump and heater are in good working order. The spa shell has been insulated to provide e cient operation in cold weather areas.
NOTE: If you elect not to drain your spa and the temperature is going to be below freezing for extended periods of time, it is best to operate the spa in the standard mode with the temperature set at the maximum high temperature of 104°F (40°C), especially if there is a power outage threat. This will help keep the spa water from freezing if you have a power failure.
If you do not intend to use your spa during the winter months and there is danger of freezing, use the following steps to winterize your spa: Winterizing a spa if done properly is a complicated procedure. When at all possible
VITA SPA
37
Page 38
this should be done by a spa service center.
ENGLISH FRANÇAIS
A freeze damaged spa can be expensive to  x. With that in mind here are some basic winterizing tips that will help you remove enough of the water and add enough RV Antifreeze to keep your plumbing from freezing. What you will need;
1. A wet /dry (shop vac) vacuum.
2. 1 to 3 gallons or RV antifreeze (nontoxic, used in Recreational Vehicles water tanks)
3. Channel lock pliers (16” works best for most tubs)
4. A funnel
5. Time, expect two to three hours. Now that you have those things,
• Drain the spa
• Vacuum all of the jets and injectors, until there is no more water coming out.
• Remove your  lter and vacuum at the  lter plumbing.
• If you have air injectors, turn power on , and make sure the pump(s) are NOT running and the heater is not  ring; (generally this can only be accomplished by unplugging the pumps from the control box and removing the connections from the heater) then turn your air blower on until water no longer comes out of air holes. Then turn the power back o .
• Loosen the plumbing connections at your pump and at your heater and remove the freeze plugs on the front face of the pump(s). Vacuum up any water that comes out.
• Reconnect the plumbing to the heater, the freeze plugs and the lower of the two connections on your pumps.
• Add RV antifreeze to the pump using your funnel. Most pumps will take approx. 4 oz.
• Reattach your pump unions.
• Add approximately 1oz. of RV anti-freeze to each of the jets. (use funnel)
• Add RV anti-freeze to the plumbing that is attached to your  lter until it runs out of the intakes in the foot well of the spa. (This is not possible in all spas)
• Add anti-freeze to the air injectors, this can be tedious but is worth the e ort. In climates that get heavy snows it is a good idea to place some plywood over your cover to help reinforce it. Then cover the spa with a tarp, and strap the tarp down, this will help keep winter winds from getting to your cover. In the spring, or when you are ready to start the tub back up.
• Make sure that all  ttings are tight.
• Fill with cool water
• Turn the power on.
• Run the jets on high speed for 30 minutes.
• Several times during the 30 minutes that you are running your pump, turn your air blower on and o . This will purge the air lines.
• Drain the spa through all drain lines supplied
• Put your  lter in the spa.
• Re ll and treat chemically like you would during a water change.
38
VITA SPA
Page 39
Spa Cabinet Care:
The cabinets are made of Excel-X™, a high quality alternative to wood that is virtually maintenance free, requiring no staining, sealing, or waxing.
To clean the spa cabinet, rinse dirt and dust regularly with clear water. To remove stubborn dirt, grime, and mild discoloration, wash with a mild detergent and warm water.
Protect spa  nish - always keep cover
on the spa when not in use.
Spa Surface Care and Cleaning
Your spa shell surface is made of acrylic. A minimum amount of care and cleaning will keep your spa looking new for years. Use a spa cleaner for residue and lime build-up at the water level of the spa surface. It may be necessary to lower the water level 5-7 cm before cleaning to avoid polluting the spa. Cleaner can be applied to the acrylic surface with a soft cloth and wiped clean. Use a non­abrasive household cleaner to clean your spa shell or use a mild dishwashing detergent. Rinse well and dry with a clean cloth.
Never use abrasive cleaners.
NOTE: Do not allow the acrylic surface to come in to contact with products such as acetone (nail polish remover), nail polish, dry cleaning solution, lacquer thinners, gasoline, pine oil, solvents, etc.
Remove dust and dry dirt with a soft, damp cloth. Avoid using razor blades or other sharp instruments that might scratch the surface.
Light Bulbs / LED Lights
The Spa light bulb / LED lights are serviceable from inside the spa cabinet. Remove the side panel and insulation closest to the light; locate the bracket that holds the bulb. Turn the black bulb holder 90 degrees counter-clockwise; remove from bracket. Pull bulb straight out and replace. Insert bulb holder back into bracket and turn 90 degrees clock-wise to secure.
Spa Cover Care:
Proper care is easy: Once a month, clean and condition the cover according to the maintenance instructions that came with your cover.
Even if you don’t condition your top vinyl every month, we recommend you give one good treatment just before snow or ice. If possible, treat during the winter too. After every snow fall or ice storm, use a soft broom to remove the accumulation from your Spa cover — this will help preserve your foam cores, and a broom won’t damage the vinyl. Handle tie-down straps and handles with care, because in really cold climates, vinyl can crack, since it will not stretch. For added security in windy and storm conditions, consider using additional tie down straps which lock down tight. Remove foam cores from the vinyl encasement. Mix two gallons of water, a teaspoon of mild dishwashing soap and one cup of bleach. With a soft bristle brush, scrub the inside of the encasement thoroughly. Then take a wash cloth and wipe down each foam core. Rinse both well. Place the
ENGLISHFRANÇAIS
VITA SPA
39
Page 40
encasement in the sun and foam cores in the
ENGLISH FRANÇAIS
shade to dry. (Do not put foam cores in the sun – they will melt!) Once everything is dry, spray the cores and inside the encasement with a mildew inhibitor like Pine Sol®. Allow all to dry completely, and then reassemble. The key here is to maintain proper water chemistry to avoid mildew. If you are using WD-40 to free the Sure-Locs, try using a Q-tip to keep the WD-40 away from your cabinet. (It can damage the  nish.)
Thermal Creep
Your Vita spa is manufactured with energy­e cient components and systems that capture heat generated by the equipment, then transfer that heat back to the spa water. In warmer climates or in situations with extended run times, “Thermal Creep” may occur. Thermal Creep is a condition whereby the actual water temperature is higher than the set temperature.
To manage “Thermal Creep” you may:  Vent your cover  Open all air controls  Set your  ltration cycles to run during the cooler times of the day or at night  Reduce the length of your  lter cycles  Visit your local Vita Spa distributor for additional guidance
Thermal Creep only occurs in well-insulated hot tubs. It is not an indication that something is wrong with your spa or its equipment.
40
VITA SPA
Page 41
COMMON PANEL MESSAGES
Message... What it is... What it means...
Pr Priming mode Spa is in normal Priming Mode operation SLP or SL Sleep mode Spa is in normal Sleep Mode operation ECN or EC Economy mode Spa is in normal Economy Mode operation STD or ST Standard mode Spa is in normal Standard Mode operation ICE or IC Freeze condition Heater will come on to keep water above 45°F
- - - or - - Water temperature Current water temperature not measured
Message Meaning What Happens… Possible Causes Action Required
No message on Display Power has been cut o to the spa
HH or OHH
* - Even when the spa is shut down, some equipment will turn on if freeze protection is needed.
“Overheat”
- *One of the sensors has detected 118F / 47.8C at the heater
The spa will shut down and will automatically reset once the water tempature has cooled to 108F (42C)
~ L o w W a t e r F l o w ~ Faulty Equip­ment
Verify power going to spa. Check for tripped breaker or blown fuse. The control panel will be disabled until pow­er returns. Spa setting will be preserved until the next power up.
DO NOT ENTER THE WATER. Remove the spa cover and allow water to cool. ~ Verify all slice valves are locked open ~ Verify Actual water tempature with a digital Thermom­eter ~ Verify normal operation of pump 1 ~ Verify all spa jets are open. Once the heater has cooled, reset by pushing any button. If the spa does not reset, shut o the power to the spa and call your dealer or service organization.
ENGLISHFRANÇAIS
VITA SPA
41
Page 42
Message Meaning What Happens… Possible Causes Action Required
ENGLISH FRANÇAIS
OH or OHS
“Overheat” ­The spa has shut down. * One of the sensors has detected that the spa water is 110F / 43.5C
The spa will shut down and will automatically reset once the water tempature has cooled to 108F (42C)
~ L o w W a t e r F l o w ~ Faulty Equip­ment ~ Extended Filtra­tion Cycles FC - or Continious Filtration ~ Thermal Creep
DO NOT ENTER THE WATER. Remove the spa cover and allow water to cool. At 107F / 41.7C, the spa should automatically reset. ~ Verify all slice valves are locked open ~ Ver­ify Actual water tem­pature with a digital Thermomiter ~ Verify normal operation of pump 1 ~ Verify all spa jets are open This con­dition can be caused by “thermal creep”, additional information on ways to manage and prevent thermal creep are located in this manual. If the spa does not reset, shut o the power to the spa and call your dealer or service organization.
SA or SnA
Sb or Snb
42
Spa is shut down. * The sensor that is plugged into the “A” jack is not working
Spa is shut down. * The sensor that is plugged into the Sensor “B” jack is not working
The spa will shut down
The spa will shut down
~ Disconnected or defective sen­sor
~ Disconnected or defective sen­sor
If the problem persists, contact your dealer or service organization. May appear temporar­ily in an over heat or freeze condition
If the problem persists, contact your dealer or service organization. May appear temporar­ily in an over heat or freeze condition
VITA SPA
Page 43
Message Meaning What Happens… Possible Causes Action Required
Sn or SnS
Sensors are out of balance.
If alternating with spa temperature, it may just be a temporary condi­tion. If  ashing by it itself, spa is shut
May appear tem­porarily in an over heat or freeze condition
If the problem persists, contact your dealer or service organization. May appear temporar­ily in an over heat or freeze condition
down*
HL or HFL
A signi cant di erence between tem­perature sen­sors has been detected. This could indicate a  ow problem
Heater will shut down while spa continues to func­tion normally
~ Low water level ~ Dirty spa  lter(s) ~ Closed spa jets
Verify water level is within 1/8” from top of weir door - make sure all jets are open, all pumps are operating normally and the spa  lter(s) are clean. If the problem persists contact your dealer or service organization
LF Persistent low
 ow problems. (Displays on the  fth occurrence of HL mes­sage within 24 hours) Heater is
Heater will shut down while spa continues to func­tion normally
~ Low water level ~ Dirty spa  lter(s) ~ Closed spa jets
Follow action required for HL message. Heating capability of the spa will not reset automatically; you may press any button
to reset. shut down, but other spa func­tions continue to run normally
ENGLISHFRANÇAIS
dr Lack of water
 owing through the heater
VITA SPA
Spa is shut down for 15 minutes
Low water Level, poor  ow, or air bubbles detected in the heater.
Verify water level is
within 1/8” from top of
weir door - make sure
all jets are open, all
pumps are operat-
ing normally and the
spa  lter(s) are clean.
Spa will reset in 15
minutes, if the prob-
lem persists contact
your dealer or service
organization
43
Page 44
Message Meaning What Happens… Possible Causes Action Required
dy Inadequate
ENGLISH FRANÇAIS
water detected in the heater (Displays on the third oc­currence of dr message) Spa is shut down.*
Spa is shut down. Possible inad-
equate water, poor  ow, or air bubbles detected in the heater.
Verify water level is
within 1/8” from top of
weir door - make sure
all jets are open and
all pumps are operat-
ing normally - verify all
jets are open and the
spa  lter(s) are clean.
Spa will not automati-
cally reset, press any
button to reset manu-
ally. If the problem
persists contact your
dealer or service orga-
nization
IC or ICE
HOt or StU
“ICE” - Potential freeze condi­tion detected
A pump has been running too long.
All Pumps and Blower are ON for at least 4 Minutes After Temp is 45°F (7.2°C) or Above You will not have control of the components during freeze pro­tection. If you spa is con gured for “low” amperage your heater may not activate until the freeze condi­tion has cleared.
This could contrib­ute to over heat conditions
Cold water - com­mon at start up when the water tempature is be­low 45°F (7.2°C)
No action required.
All equipment will
automatically activate
regardless of spa
status.
SHUT THE POWER
TO THE SPA OFF
AND CONTACT YOUR
DEALER OR SERVICE
CENTER.
44
VITA SPA
Page 45
COMMON WATER PROBLEMS
Problem
Cloudy Water
Water Odor
Usual Cause
- Inadequate  ltration/ dirty  lter
- Excessive oils/organic matter
- Improper sanitation/ bacteria
- High pH and/or high alkalinity
- Excessive organics or chloramines; insu cient free available sanitizer
- Improper sanitation
- Inadequate  ltration
- Low pH
Solution
ENGLISHFRANÇAIS
- Check to make sure the  lter is running properly; clean  lter with a  lter cleaner of degreaser
- Shock the spa with a chlorine or bromine sanitizer, or other shock treatment product
- Increase sanitizer level to balance water and shock if needed
- Adjust pH; add appropriate sodium bisulfate product
- Use clari er
NOTE: If using an ozone generator, consult with your dealer before using polymer based clari ers
- Depending on the severity, drain the spa
completely, clean and re ll
- Shock the spa with a chlorine or
bromine sanitizer/shock, or other shock
treatment product
- Increase sanitizer level to balance water;
shock if needed
- Check to make sure the  lter is running
properly; clean  lter with a  lter cleaner
or degreaser
- Raise pH with sodium bicarbonate product.
If metals are present, add chelating agent.
Chlorine Odor
Bromine Odor/ Yellow Water
VITA SPA
- Too many chloramines/ insu cient free available chlorine
- Low pH
- Low pH
- Shock the spa with a chlorine sanitizer/
shock, or non-chlorine shock treatment
- Adjust pH; raise pH with sodium bicarbonate
product
- Adjust pH; raise pH with sodium bicarbonate
poduct
45
Page 46
Problem
Usual Cause
Solution
ENGLISH FRANÇAIS
Musty Odor
Foaming/ Scum Ring Around the tub
Algae
Eye Irritation
Skin Irritation/ Rash
Scale
- Bacterial or algae growth
- Build up of body oils, lotion and chemicals resulting from soap or detergent
- pH Imbalance
- Low free chlorine or bromine
- Low pH
- Insu cient free available chlorine
- Unsanitary/polluted water
- Soaking too long
- Chemicals not balanced, excessive ozone
- Too much calcium dissolved in water
- pH and total alkalinity too high
- Shock spa with a chlorine or bromine sanitizer/
shock, of equivalent shock treatment product.
If problem is visible, drain, clean, re ll and
balance spa
- Skim foam o using your leaf net or
drain and re ll
- Adjust pH
- Shock with a chlorine of bromine
- Raise pH with sodium bicarbonate product
- Shock with a chlorine sanitizer/shock or
other shock treatment product
- Keep recommended sanitizer residual at all
times; superchlorinate or use a non-chlo rine shock treatment
- Soak for smaller intervals, such as 15 minutes
- Correct chemical imbalance
- Add a scale control product. Adjust total
alkalinity and pH levels by adding the
appropriate sodium bisulfate product; for
concentrated scale deposits
- Drain spa, scrub the scale o , re ll the spa
and balance the water
Erratic pH Test Results/Unusual
- Sanitizer level too high
- Old pH indicator dye
pH Test Color
46
- Test the pH, when the sanitizer level is
below 5 ppm
- Replace the pH indicator dye / test strips
VITA SPA
Page 47
Problem
Usual Cause
Solution
Sanitizer Dissipating Too Rapidly
- Excessive organics in water
- Temperature too high
- Low pH
- Low calcium hardness
- Low total alkalinity
- Increase shock dosage; add sanitizer;
shower before entering spa
- Reduce temperature
- Raise pH with sodium bicarbonate product
- Use chelating agent if metals are present.
Keep proper pH level (7.2 to 7.6).
- Use chelating agent if metals are present.
Maintain minimum 150-200 ppm calcium
hardness
- Use chelating agent if metals are present.
Maintain proper alkalinity for type of
sanitizer used.
NOTE: If your source water has a high metal or mineral content, a specialty chemical should be used to avoid staining or accumulation of deposits. These guidelines cover the most common water problems. Contact your dealer for furtherinformation regarding chemical control issues.
ENGLISHFRANÇAIS
VITA SPA
47
Page 48
COMMON HARDWARE PROBLEMS
ENGLISH FRANÇAIS
Problem
Usual Cause
Solution
System not operating
Heater not operating
Water not clean
Abnormal water usage
Overheating
- House circuit breaker tripped or in OFF position
- Water level too low
- Heater mode not selected
- No power to heater
- Clogged or blocked  oor suction or skimmer
- Filter clogged (dirty)
- Poor water chemistry
- Insu cient  ltering time
- Improper maintenance
- High content of solids in water
- Excessive evaporation and/or splashing
- High ambient temperature
- Reset circuit breaker on house breaker panel
- Add water to reach 1/8” below
the top of the weir door
- Refer to temperature/heater functioning. See Control instructions pg. 20, 26, or 31
- Check house circuit breaker
- Contact dealer
- Clean  oor suction/skimmer. Remove blockage
- Clean or replace
- See Maintenance section pg. 41
- Run  ltration mode longer
- Contact dealer
- Use clari er or drain and re ll spa
- Use spa cover and re ll as necessary
- Contact dealer
Low water  ow from jets
Noisy pump and motor
48
- Operating in FILTER mode-low speed
- Clogged or blocked suction or skimmer
- Dirty  lter
- Jets in OFF position
- Slice valves closed
- Clogged  oor suction or skimmer
- Low water level
- Damaged or worn motor bearings
- Select hi-speed jets
- Clean  oor suction/skimmer. Remove blockage
- Clean or replace
- Open jets
- Contact dealer
- Clean  oor suction/skimmer
- Add water to normal water level (15cm below lip)
- Contact dealer
VITA SPA
Page 49
Problem
Usual Cause
Solution
No water  ow from jets
Water leakage from under spa
No air  ow from jets
Motor will not operate
Black powder  lm around water line
- Pump not primed
- Adjustable jets turned o
- House circuit breaker tripped, no power to system
- Faulty pump or motor
- Pump surges
- Slice valves closed
- Check unions & drain hoses
- Air control not open
- Jet nozzle not seated properly
- Jet nozzle missing
- House circuit breaker tripped or in OFF position
- Improper or defective wiring or electrical supply
- Thermal Overload Protection switch tripped
- Wearing in of turbo/blower brushes
- See Priming section, pg. 16
- Turn on jets
- Reset circuit breaker at house panel
- Low water. Check level on Weir door
- Contact dealer
- Close or tighten as necessary
- Open control
- Check jet nozzles
- Inspect jets and replace as needed
- Reset circuit breaker
- Contact dealer
- Auto reset after motor has cooled. Contact dealer if motor continues to cycle
- Will disappear after use
ENGLISHFRANÇAIS
The spa will not shut o
VITA SPA
- Spa trying to heat
- Spa is in  lter cycle
- Spa is in Standard Mode
- Check ‘Set Temperature’ in Standard Mode
- Normal. No need to change
- Check mode setting
49
Page 50
SPA SOAKING GUIDELINES
ENGLISH FRANÇAIS
1. Persons with heart disease, diabetes, blood pressure or circulatory abnormalities, a serious illness, or pregnant women should not enter a spa without prior consultation with their doctor.
2. People with skin, ear, genital or other body infections, open sores, or wounds should not use the spa because of the possibility of spreading infection.
3. Before entering, look at the water in your spa. If there is cloudiness, foaming, or if a strong chlorine smell is present, the water needs treatment. Properly maintained water will greatly reduce potential skin rash (pseudomonas). Ask your Authorized Vita Spa Dealer for guidance.
4. Shower with soap and water before and after using the spa. Showering before use removes many common skin bacteria, perspiration, lotions, deodorants, creams, etc. that may reduce the e ectiveness of the sanitizer and lessen the ability of the  lter to work e ciently. Showering after use will help reduce skin irritation that may result from contact with spa chemicals.
6. Soaking for too long may cause some users to feel nauseous, dizzy, or light-headed. If you wish to soak in high temperature water (104°F, 40°C), leave the spa after 15 minutes, shower, cool down and then return for another brief stay. In lower temperatures (e.g. 98.6°F, 37°C, normal body temperature) most people can comfortably and safely soak for longer periods at one sitting. If you have any questions about what’s right for you, your family, or other guests, consult your doctor.
7. Be sure you check the water temperature before entering, and while using the spa.
8. Never use the spa while under the in uence of alcohol.
9. Consult your doctor about potential harmful e ects of using drugs or medications while hot water soaking.
10. Never use the spa when you are alone.
11. Never allow children or elderly adults to
use the spa unsupervised.
5. Enter the spa slowly and cautiously. Be careful of your footing, and allow your body to gradually adjust to the water temperature. Exit slowly to accommodate relaxed leg muscles and possible light-headedness.
50
VITA SPA
Page 51
167 SERIES SYSTEM WIRING DIAGRAM
Wiring Diagram For Spa Models Amour, Image, Intrigue, & Duet (240VAC)
ENGLISHFRANÇAIS
VITA SPA
51
Page 52
460 SERIES SYSTEM WIRING DIAGRAM
ENGLISH FRANÇAIS
Wiring Diagram For Spa Models Joli, Cabaret, Nuage, Passion, Chateau (240VAC)
52
VITA SPA
Page 53
504 SERIES SYSTEM WIRING DIAGRAM
Wiring Diagram For Spa Models Intrigue, Elegant, Monarque, Prestigue, Emvie, & Grand (240VAC)
ENGLISHFRANÇAIS
VITA SPA
53
Page 54
760 SERIES SYSTEM WIRING DIAGRAM
ENGLISH FRANÇAIS
Wiring Diagram For Spa Models Rendezvous & Mystique (240VAC)
54
VITA SPA
Page 55
ENGLISHFRANÇAIS
VITA SPA
55
Page 56
SAFETY SIGN
ENGLISH FRANÇAIS
The safety sign enclosed with your Owner’s Manual should be permanently installed where visible to all users of the spa. This sign is adhesive backed and includes four screws for mounting the sign on rough surfaces. It is very important that you, as a spa owner, review the important safety instructions and warnings before you operate your spa. It is equally important that you instruct all users, even occasional ones, as to the warnings associated with spa use. You may obtain additional signs by contacting :
USA: MAAX Spas Industries Corp.. Customer Service 25605 South Arizona Avenue Chandler, Arizona 85248 www.maaxspas.com
LIMITED WARRANTY SUMMARY
Please refer to the Warranty Card included with your product for complete warranty information. In order to receive prompt warranty service, you must return your warranty card, completed with model and serial number, to your dealer immediately upon completion of the spa installation. MAAX Spas Industries Corp.. provides a limited warranty to our customers. It applies to the spa structure, surface, plumbing, pumps, heater, blower, and controls. The limited warranty does not cover damage resulting from improper maintenance, improper installation, misuse, abuse, neglect,, accident,  re, normal wear and tear, or improper water maintenance. Unauthorized modi cations of the spa may void the warranty. Replacement cost associated with transportation, removal and reinstallation are the sole responsibility of the spa owner. This manual refers to only year 2010 Vita model spas. MAAX Spas Industries Corp., reserves the right to make changes in design or material of its products at any time without incurring liability. This limited warranty applies to the  rst retail purchaser and terminates upon any transfer of ownership.
56
VITA SPA
Page 57
COPYRIGHTS AND TRADEMARKS
©Copyright 2010 MAAX Spas Industries Corp.. All rights reserved. No parts of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means (electronic, mechanical, photocopying, recording or otherwise), without prior written permission. Vita Spa
Disclaimer:
The information in this manual is accurate to the best of MAAX Spas Industries Corporations’ knowledge. However, MAAX Spas Industries Corporation assumes no responsibility for errors or omissions. Nor is any liability assumed for damages resulting from use of the information contained herein. Speci cations subject to change without notice. Spas shown at percentage of actual size.
Congratulations on your purchase of an Vita Spa from MAAX® Spas. Your Owner’s Manual provides installation, operation and maintenance instructions. Please review it and keep it for future references.
TM
, Powerworks TM, are registered trademarks of MAAX® Spas.
ENGLISHFRANÇAIS
Save These Instructions Owner’s Record Information
Date Purchases :
Purchased From :
Phone Number :
Installed By :
Serial Number : Model :
VITA SPA
57
Page 58
NOTES
ENGLISH FRANÇAIS
58
VITA SPA