Vitasigns ProSeries 2 Quick Start Manual

ProSeries 2
Blood Pressure Monitor
Quick Start Guide
A complete user guide is available at vitasigns.com VS47129-0200
Welcome to
Our mission is to empower you to live a healthy life. We’re
passionate about creating simple technology that helps you
fitness goals.
Our intelligent devices improve your health awareness by
making it easy to measure, monitor, and track your weight,
pulse rate, blood pressure, steps, activity, and more.
Every day – people just like you choose our products. We
honor that choice by ensuring our products are the highest
quality and by doing business responsibly.
Thank you for making Vitasings part of your life.
Safety Information ............................................................................................... 1
ProSeries2 LCD Display......................................................................................5
Getting Started ...................................................................................................... 7
Monitor Components ........................................................................................8
Configuring the ProSeries2 ............................................................................ 9
Prepare to Measure .......................................................................................... 10
Measurement Tips............................................................................................. 11
Taking a Measurement ................................................................................... 12
Records Management .................................................................................... 13
Maintenance......................................................................................................... 14
Vitasigns Application ....................................................................................... 15
Systolic & Diastolic Pressure ........................................................................ 17
Standard Blood Pressure ............................................................................... 18
Irregular Heartbeat Detector ...................................................................... 19
Frequently Asked Questions ....................................................................... 20
Troubleshooting ................................................................................................. 21
Specifications ....................................................................................................... 22
Complied Standards ........................................................................................ 23
FCC Statement .................................................................................................... 24
EMC Guidance ..................................................................................................... 24
Table of Contents
The ProSeries2 measures systolic and diastolic blood pressure and pulse rate of an adult by using a pressurized cuff on the upper arm. The device is not intended for use on infants and children. The device is designed for home use only, and is not intended for ambulatory measurement - measurement recorded continuously throughout the day.
Blood pressure measurements determined with this device are equivalent to those obtained by a trained observer using the American National Standard, Manual, Electronic or automated sphygmomanometers.
If you suffer from disorder of heart rhythm (arrhythmia), only use this blood pressure monitor after consulting with your physician. In certain oscillometric cases, this measurement method may produce incorrect readings.
This Vitasigns measurement device is not intended to be a diagnostic device. Contact your physician immediately if pre­hypertensive or hypertensive values are indicated.
Safety Information
1
Symbol Description
The Operation Guide Must be Read
Complies with FCC Rules
Manufacturer
Serial Number
Indoor Use Only
Class II Equipment
Type BF Applied Parts
Direct Current
T1A/250V ø3.6*10CCC
Manufacturer Date ENVIRONMENT PROTECTION - Wast electrical
products should not be disposed of with house­hold waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice
Safety Information
F1
2
Read this user manual thoroughly before use. This device is designed and manufactured to operate within defined design limits. Misuse may result in harm. The following should be observed to best use and maintain your device:
This device is intended for adult use only.
This device is intended for non-invasive measuring and
monitoring of arterial blood pressure. It is not intended for use on body extremities other than the wrist.
Its sole functions are blood pressure and heart rate
measurement.
Monitoring blood pressure with this device does not
equate to a medical diagnosis.
This device allows you to monitor your blood pressure
under the care of a physician.
If you are taking medication, consult with your physician
to determine the most appropriate time for your measurement. Never change a prescribed medication without your physician’s consent.
This device is not suitable for continuous monitoring
during medical emergencies or operations.
Caution
3
If the pressure of the cuff exceeds 40 kPa (300 mmHg),
the device will automatically deflate. Should the cuff not deflate when its pressure exceeds 40 kPa (300 mmHg), detach the cuff from the wrist and press START/STOP to stop inflation.
Do not use the monitor under the conditions of strong
electromagnetic field (e.g. medical radio frequency equipment) that radiates interference signal or electrical fast transient/burst signal.
The device is not AP/APG equipment. It is not suitable for
use in the presence of flammable gases (avoid oxygen, nitrous oxide).
Keep the unit out of reach of infants or children. Inhalation
or swallowing of the device’s small pieces is dangerous or even fatal.
Use only accessories and detachable parts specified and
authorized by the manufacturer. Not doing so may cause damage to the unit or danger to you.
Caution
4
Norm.
Hype.
G3
G2
G1
Hypo.
Memory Review
Start
Stop
Mem Set
ProSeries2 LCD Display
Diastolic
Blood Pressure
Measurement
Unites
In Memory
Review Mode
Systolic
Blood Pressure
Low Battery
Indicator
Heartbeat
Detection
Pulse Rate
Per Minute
Date and Time
Indicator
Irregular
Heartbeat Detected
Average of Last 3
Reading Showing
User Indicators
User 1, User 2
Appears Next to
Blood Pressure Grade
Important Symbols
6
Loading...