Installation Instructions
0
0.8
1.0
INTRODUCTION
VPC9032/CM and VPC9132/CM series cameras are designed to give a good image over a broad range of scene illumination. To achieve this, the camera operates in colour mode where the scene illumination is bright and automatically switches to monochrome where the scene illumination is low. Typically, the switchover occurs at approximately 2.0 lux.
TABLE 1
Option
VPM8030
VPM8032
VPM8120
VPM8130
VPM8122
VPM8132
VPC9130
VPC9132
VPC9032/CM
VPC9030
VPC9032
VPC9132/CM
Mono Color Color/Mono Resolution (TVL) Sensitivity (lux @ f1.2) CCD Sensor size
380 380 570 570 480 480 330 48
0.1 0.1 1.00.1 0.1 1.0
0.1 0.9
1/3“ 1/3“1/3“ 1/3“
1/3“ 1/2“ 1/3“1/3“ 1/2“ 1/3“ 1/3“ 1/3
0.1
570570 330 330
0.9
2.0 2.0
Sony SuperHAD™ CCD DSP Digital Signal Processing Adjustable Gamma (0.45 and 1.0) Automatic Gain Co n trol (AGC) Backlight Compensation (BLC) BLC on/off Electronic Iris (EI) EI on/off Auto Iris connection Line lock with phase adjust (AC only) Internal Sync.
Supply
11 - 40 VDC; 14 - 30 VAC 98 - 260 VAC
Note: NTSC and EIA camera models have suffixes /N and /E respectively. These variants
are also covered by Table 1.
2
Installation Instructions
PRODUCT SAFETY
 Installation and servicing is only to be carried out by suitably qualified and
experienced personnel.
 Mains cameras contain hazardous voltages.
 Do not remove covers as there is a risk of injury or death by electric shock.
 Cameras connected to mains supplies must be earthed.
 Only power low voltage cameras from a class 2 isolated power supply.
This camera range is designed for use in general purpose CCTV applications and has no other purpose. Only operate your camera between the temperatures of -10
O
C and +50OC. Do not operate your camera outside its specified power supply range. Cameras must only be used in clean, dry, dust-free environments unless housed in suitable protective housings to IP65 or better.
ELECTROMAGNETIC COMPATIBILITY (EMC)
This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
This product is intended solely for use in general CCTV applications.
The product must be installed and maintained in accordance with good installation practice to enable the product to function as intended and to prevent problems. Refer to Norbain SD Limited for installation guidance.
MANUFACTURERS DECLARATION OF CONFORMANCE
The manufacturer declares that the equipment supplied with this manual is compliant with the essential protection requirements of the EMC directive 89/336 and the Low Voltage Directive LVD 73/23 EEC. Conforming to the requirements of standards EN 55022 for emissions, IEC801 parts 2, 3 and 4 for immunity and EN 60950 for Electrical Equipment safety.
3
Installation Instructions
CAUTIONS
In order to avoid damaging the camera note the following points:
1) The camera has threaded mounting points on the top and bottom of the case. Only use a standard, photographic, mounting-bolt with a 1/4 20 UNC thread.
2) Before fitting the lens make sure that its back will not touch the CCD sensor or associated components when screwed fully home.
3) Do not touch the image-surface of the sensor. If the sensor is accidentally touched, only clean it using ethyl alcohol.
4) Do not expose the camera sensor to very bright light over a long period of time as this may cause damage to the CCD. The camera and lens set-up must be correct to avoid continual over exposure by bright light.
5) The weight of your camera is 0.5kg (0.35kg for low voltage versions).
6) Only use your camera in a clean, dust-free environment.
7) For outdoor use, an appropriate protective housing conforming to IP65 or UL50 or better must be used.
POWER SUPPLY
Cameras are available in AC mains and AC and DC low voltage types. The voltage required to operate the camera is clearly marked on the rear panel of the camera. Only power low voltage cameras from a class 2 isolated power supply. The typical power
consumption of a VP... series camera is less than 5 Watts.
Mains Power Supply
Cameras that are intended to operate directly from the mains supply are fitted with a non­detachable power supply cord. The voltage of operation is clearly marked on the rear panel of the camera. Generally this is 98 to 260 VAC at 50 Hz for CCIR/PAL (60Hz for EIA/NTSC).
REFER TO THE WIRING INSTRUCTION LABEL ATTACHED TO THE SUPPLY CORD and terminate the cord with the appropriate circuit fitted with a 3A fuse.
MAINS CAMERAS MUST BE CONNECTED TO A PROTECTIVE EARTH GROUND. Ensure that a secure means of isolation from the mains is provided for the camera in accordance with the national wiring regulations of the country of installation.
Auto-Switching Power Supply
Cameras fitted with an automatic selecting power supply operate between 11-40 VDC and 14-30 VAC. Connections and polarity are indicated above the screw terminals on the rear panel. The power supply must be a class 2 isolated type.