Vista 8229, 8230, 8231 Installation Instructions Manual

INSTALLATION INSTRUCTIONS FOR 12 VOLT
W
BOLLARD
MODEL 8229/ 8230/ 8231
FOR USE ONLY WITH LOW VOLTAGE LANDSCAPE POWER UNITS THAT DO NOT EXCEED 25 AMPS, 15 VOLT MAX.
ARNING: Bollard luminaires must be installed in accordance with the National Electrical
Lens and metal around lamp can become hot enough to blister hands. Particular care should be taken not to locate luminaires where small children can reach them if high wattage lamps are used.
LUMINAIRES ARE NOT TO BE INSTALLED WITHIN 10 FT. (3.05M) OF A POOL OR SPA. SECONDARY CABLE IS NOT TO BE BURIED MORE THAN 6". WHEN USING MULTIPLE LUMINAIRES, LOAD IS NOT TO EXCEED TOTAL WATTS OF TRANSFORMER RATING. DO NOT USE EXTENSION CORDS ON POWER UNITS. NOTE: Always use UL recognized wire connectors for connections. NOTE: Save these instructions for future reference.
TOOLS REQUIRED FOR INSTALLATION:
Flat head screwdriver Shovel Wire strippers 7/16 Wrench 1/8 Allen head wrench Silicone grease Cement concrete (if pour concrete method chosen)
INSTRUCTIONS FOR STAKE MOUNT INSTALLATION
NOTE: Your Vista 12 volt Bollards are shipped with a ground stake to facilitate a stake mount installation. However, for a permanent and secure installation a concrete footing
support for the bollard base is recommended.
1. To prevent electrical shock, disconnect transformer from electrical supply before installation or service.
2. Dig a hole approximately 3" diameter by 2" deep at selected location.
3. Using the 1/2" threaded short nipple (provided), attach ground stake to center hole in bollard base and insert stake with base into the ground until bottom of base is even with grade.
4. Run wire pigtail through bottom hole of base and strip the two (2) leads from the
W
8
bollard wire. Using the two (2) silicone filled safety connectors (provided), connect the leads from the bollard to the main supply cable leads. Any excess pigtail wire should be coiled inside base as to allow bollard to be lifted from base if ever necessary. NOTE: Luminaires are supplied with 36" of 18-2 cable pigtail for secure connection to the main
supply cable. The wire is to be protected by routing in close proximity to the luminaire. The wiring shall be buried a maximum of 6 inches (15.2 cm) in order to connect the main supply cable.
5. Slip bollard over base and attach with set screws on bollard using 1/8" allen head wrench.
INSTRUCTIONS FOR POUR CONCRETE INSTALLATION
NOTE: Pour concrete installation requires conduit sleeve as to allow 36" pigtail to exit through concrete footing.
1. To prevent electrical shock, disconnect transformer from electrical supply before installation or service.
2. Dig a hole approximately 12" diameter by 6" deep at selected location.
3. Install conduit sweep and foundation anchors to base.
4. Using standard masonry procedures, support bollard base in selected location making sure foundation anchor nuts remain above concrete grade.
5. Pour concrete making sure exited end of the sleeve reaches outside concrete.
6. Once concrete cures, run wire pigtail through bottom sleeve and strip the two (2) leads from bollard wire. Using the two (2) silicone filled safety connectors (provided), connect leads from bollard pigtail to main supply cable leads. Any excess pigtail wire should be coiled inside base as to allow bollard to be lifted from base if ever necessary. NOTE: Luminaires are supplied with 36" of 18-2 cable pigtail for secure connection to the main
supply cable. The wire is to be protected by routing in close proximity to the luminaire. The wiring shall be buried a maximum of 6 inches (15.2 cm) in order to connect the main supply cable.
7. Slip bollard over base and attach with set screws in bollard using 1/8" allen head wrench.
IMPORTANT SAFETY INSTRUCTIONS LIGHTED LAMP IS HOT!!
ARNING: TO REDUCE THE RISK OF FIRE, OR INJURY TO
PERSONS:
1. Turn off/unplug and allow to cool before replacing lamp.
2. Lamps get hot quickly! Contact only switch/plug when turning on.
3. Do not touch hot lens, guard or enclosure.
4. Keep lamp away from material that may burn.
5. Do not touch the lamp at any time. Use a soft cloth. Oil from the skin may damage lamp.
6. Do not operate luminaire fitting with a missing or damaged cover.
LAMP INSTALLATION/REPLACEMENT: CAUTION: Do not exceed maximum wattage marked on luminaire label.
1. To prevent electrical shock, disconnect transformer from electrical supply before service.
2. Loosen the three (3) cover screws and remove cover.
3. Remove lens and gasket.
4. Replace lamp with correct wattage and type marked on fixture label. NOTE: DO NOT touch lamp with bare hands. Always use soft cloth or the plastic wrapping (if available) from the lamp to handle the lamp.
5. Re-install cover and gasket and tighten the three (3) screws evenly.
VISTA PROFESSIONAL OUTDOOR LIGHTING Division of U.S.T.E. Inc. Website: www.vistapro.com 1625 Surveyor Avenue, Simi Valley, CA 93063 (805) 527-0987 FAX: (805) 527-6830 (800) 766-847