operating in true Quad configuration (patented) with true motion
recognition (TMR) processing for each of the 8 PIR detectors.
• Advanced Obsidian Black MirrorTM optics (patent pending).
• Optimum performance even in poor weather conditions such as snow,
rain, dust, wind and direct sunlight
• Tamper protection prevents opening and removal from wall
• PowerG two-way Frequency Hopping Spread Spectrum FHSS-
TDMA technology - provides robustness and reliability
• Built-in link quality indicators enable installer to check signal quality
without physically approaching the control panel.
• Robust housing with recessed window.
• Smart anti masking distinguishes between masking spray and rain.
• Alarm LED is visible in sunlight.
• Automatic termination of walk-test after 15 minutes.
• Microprocessor-controlled temperature compensation.
• Immunity to pets weighing up to 18 Kg (40lb) – see Table 1
• Built-in swivel bracket
The camera’s features are as follows:
• Up to 10 cameras can be enrolled
• Images multiplexed from all enrolled cameras
• Color and black & white images
• Auto-setup
• Camera tuning by simple walk-test
• Day and night CMOS camera, with near IR illumination. This allows
taking pictures in full darkness without letting the intruder know.
• Instant capture: guarantees capture of fast moving intruder.
• Optional AC power
• An event records 2 images per second. 10-15 images total
Notes:
1. For UL/ULC installation, the camera feature is not to be enabled in UL
listed product.
2. Pet immunity is not evaluated by UL/ULC.
A. IR LEDs B. Indication LED C. Camera
D. External power LED E. Alarm LED
Figure 1. External View
2222.
. .
. INSTALLATION
INSTALLATIONINSTALLATION
INSTALLATION
2.1 Installation
A. Bracket installation (see Figure 2). Fix the bracket firmly on a stable wall or pillar. The orientation of the fixed bracket must be as parallel as
possible to the surveyed ground surface.
B. Adjust the detector's horizontal and vertical angles (see Figure 3), according to the surveyed ground surface. The vertical angle indicator
position for various installation height and coverage distance combinations is detailed in Table 1. (The information refers to a relatively flat
surveyed area. Verify the correct installation by walk-test.)
C. Fasten the detector to the bracket (see Figure 2 step 4).
Table 1 - Vertical Adjustment Reference
Mounting Height
Coverage Distance
2m / 6.7ft 4m / 13ft 6m / 20ft 8m / 26ft 10m / 33 ft 12m / 39 ft