Visonic TOWER CAM PG2 TOWER CAM PG2 Installation Instructions Manual

D-304493 TOWER CAM PG2 Installation Instructions 1
TOWER CAM PG2
TOWER CAM PG2TOWER CAM PG2
TOWER CAM PG2
PowerG, Outdoor Mirror PIR Motion Detector with Anti­masking and Built-In Camera
Installation Instructions
1. INTRODUCTION
1. INTRODUCTION1. INTRODUCTION
1. INTRODUCTION
The TOWER CAM PG2 is a 2-way, wireless outdoor digital mirror PIR detector with built-in camera. Activated upon PIR detection or upon demand, the TOWER CAM PG2 sends clear images to the Monitoring Station for alarm image verification.
The PIR motion detector’s features are as follows:
Operates with PowerMaster control panels
(version 18 and higher)
Patented 8 independent quad PIR detectors (Octa-QUAD)
operating in true Quad configuration (patented) with true motion recognition (TMR) processing for each of the 8 PIR detectors.
Advanced Obsidian Black MirrorTM optics (patent pending).
Optimum performance even in poor weather conditions such as snow,
rain, dust, wind and direct sunlight
Tamper protection prevents opening and removal from wall
PowerG two-way Frequency Hopping Spread Spectrum FHSS-
TDMA technology - provides robustness and reliability
Built-in link quality indicators enable installer to check signal quality without physically approaching the control panel.
Robust housing with recessed window.
Smart anti masking distinguishes between masking spray and rain.
Alarm LED is visible in sunlight.
Automatic termination of walk-test after 15 minutes.
Microprocessor-controlled temperature compensation.
Immunity to pets weighing up to 18 Kg (40lb) – see Table 1
Built-in swivel bracket
The camera’s features are as follows:
Up to 10 cameras can be enrolled
Images multiplexed from all enrolled cameras
Color and black & white images
Auto-setup
Camera tuning by simple walk-test
Day and night CMOS camera, with near IR illumination. This allows
taking pictures in full darkness without letting the intruder know.
Instant capture: guarantees capture of fast moving intruder.
Optional AC power
An event records 2 images per second. 10-15 images total
Notes:
1. For UL/ULC installation, the camera feature is not to be enabled in UL listed product.
2. Pet immunity is not evaluated by UL/ULC.
A. IR LEDs B. Indication LED C. Camera
D. External power LED E. Alarm LED
Figure 1. External View
2222.
. .
. INSTALLATION
INSTALLATIONINSTALLATION
INSTALLATION
2.1 Installation
A. Bracket installation (see Figure 2). Fix the bracket firmly on a stable wall or pillar. The orientation of the fixed bracket must be as parallel as
possible to the surveyed ground surface.
B. Adjust the detector's horizontal and vertical angles (see Figure 3), according to the surveyed ground surface. The vertical angle indicator
position for various installation height and coverage distance combinations is detailed in Table 1. (The information refers to a relatively flat surveyed area. Verify the correct installation by walk-test.)
C. Fasten the detector to the bracket (see Figure 2 step 4).
Table 1 - Vertical Adjustment Reference
Mounting Height
Coverage Distance
2m / 6.7ft 4m / 13ft 6m / 20ft 8m / 26ft 10m / 33 ft 12m / 39 ft
3.0m / 10 ft
- 1 2 2 3 3
2.5m / 8 ft
1 1 2 3 4 4
2.0m / 7 ft
1 2 3 4 5 5
1.5m / 5 ft
2 3 4 5 5 -
2 D-304493 TOWER CAM PG2 Installation Instructions
Notes:
1. For UL/ULC listed installations the following setting is required when mounting at a height of 8ft:
2. For UL/ULC listed installations the maximum range of the detection is 10m/33ft”.
3. The grayed-in cells in Table 1 are the installation options recommended for reducing the probability of false alarms from pets.
Event counter: One region
Correct Installation
Incorrect Installation
A. Mark drilling point
B. Screw hole for wall tamper C. Drill
D. Fasten E. Three long screws F. Two short screws
Note: The 2 screw holes enable adjustment of the bracket on the wall, if needed, following the walk test.
Figure 2 - Installation
HORIZONTAL ADJUSTMENT (-45°°°° to +45°°°°)
VERTICAL ADJUSTMENT (0°°°° to -10°°°° in 2.5°°°° clicks / steps)
D-304493 TOWER CAM PG2 Installation Instructions 3
Installation Notes:
The top cover should only be accessed by authorized service personnel or manufacturer. Do not obscure the detector field of view with large objects. Install in position such that expected intruder motion is perpendicular to the zones of detection.
Alarms triggered by conditions such as weather, blowing leaves and brush, or related environmental conditions, etc., need to be considered when assessing the installation and application. It is recommended that the intrusion detection unit is not to be connected to an alarm initiating circuit but may be connected to a trouble alarm circuit if nuisance trips are not tolerable.
COVER CLOSURE
1. Release locking 2. Adjust 3. Lock 4. Release locking 5. Adjust
6. Lock 7. Turn cover and push slider 8 & 9. Put back cover 10. Secure with screw
A. Vertical angle steps
Figure 3 - Adjustment and Cover Closure
2.2 Battery Insertion
It is recommended to perform the first batteries insertion on a flat surface (see Figure 4). After battery insertion, the LED will flash for 60 seconds and then the detector will enter a 15 minutes' local diagnostic mode.
Loading...
+ 5 hidden pages