Visonic TOWER30PG2 User Manual

TOWER-30AM PG2 / TOWER-30AM K9 PG2
WirelessPowerGHighsecurityMirrorDetectorwith
Antimasking
1. INTRODUCTION
The TOWER-30AM PG2 and TOWER-30AM K9 PG2 (pet-immune) are 2-way, microprocessor­controlled, wireless digital mirror PIR detectors which include the following features:
Adaptive Active Infra-Red Anti-Masking technology providing the most advanced reliable protection against

intentional masking attempts (patent pending)
 Includes a fully supervised PowerG transceiver.  Incorporates patent pending black mirrors for extremely high white light immunity.  Advanced elliptical / parabolic mirror technology (patent pending)  Provides multiple curtain coverage (patent pending)  V-slot® optic technology (patent pending) for improved robustness, anti-vandalism and for very high
reliability.
 Creep zone protection  TOWER-30AM K9 PG2  The advanced True Motion Recognitionalgorithm (patented) allows distinguishing between the true
motion of an intruder and any other disturbances which may cause false alarms.
 Built-in link quality indicators; no need for the installer to physically approach the control panel thus
making installation faster and easier.
 No vertical adjustment is needed.  Motion event counter determines whether 1 or 2 consecutive motion events will trigger an alarm.  Automatic termination of walk-test after 15 minutes.  Microprocessor-controlled temperature compensation.  Sealed chamber protects the optical system.  Front and back tamper protection.  Self-test
can distinguish between human beings and pets weighing up to 18 kg (40 lb)
A
B
C
A. Screw cover B. LED
C. PIR optical window
Figure 1. General View
2. INSTALLATION
2.1 General Guidance (see Fig. 2)
1. Keep away from heat sources.
2. Do not expose to air drafts.
3. Do not install outdoors.
4. Avoid direct sunshine.
5. Keep wiring away from power cables.
6. Do not install behind partitions.
7. Mount on solid stable surface.
WARNING! To comply with FCC and IC RF exposure compliance requirements, the PIR detector should be located at a distance of at least 20 cm from all persons during normal operation. The antennas used for this product must not be co-located or operated in conjunction with any other antenna or transmitter
1 2 3
4 5 6
7
Figure 2. General Guidelines
Important! The detector is immune to 38 kg (85
lb) animals moving on the floor or climbing on furniture as long as the activity takes place below 1 m (3 ft). Above the 1 m (3 ft) height limit, the detector is immune to 19 kg (42 lb) pets, but the pet immunity will decrease as the pet gets closer to the detector. It is therefore recommended to select a mounting location that minimizes potential close proximity of animals.
D-303372 TOWER-30AM PG2, TOWER-30AM K9 PG2 Installation Instructions 1
2.2 Mounting
1
3
2
4
5
Note: For the desired detector's range and height, use mounting
a
holes
or b, as specified in the table.
A
C
a
C
a b
b
a – upper surface (without downward tilt) b – lower surface (with downward tilt)
ft m
10 3.0
9 2.7 8 2.4 7 2.1 6 1.8
b
b
b
b
b
b
b
a
b
309451260 ft
15
6
b
b
a
a
a
a
a
B
15 m
6
D E F
2 D-303372 TOWER-30AM PG2, TOWER-30AM K9 PG2 Installation Instructions
Loading...