TOWER-20 PG2
PowerG, Outdoor Mirror PIR Motion Detector with Anti-masking and Built-In
Camera
Installation Instructions
1. INTRODUCTION
The TOWER 20 AM PG2 is a 2-way, wireless outdoor digital mirror PIR detector which includes the following features:
l Patented 8 independent quad PIR detectors (Octa-QUAD
processing for each of the 8 PIR detectors, as well as central motion pr ocessingthat distinguishes between moving intruders and trees and bushes
in motion.
l Advanced Obsidian Black Mirror
l Optimum performance even in poor weather conditions such as snow, rain, dust, wind and direct sunlight
l Tamper protection prevents opening and removal fr om wall
l PowerG two-way Frequency Hopping Spread Spectrum FHSS-TDMA technology - provides robustness and reliabilitythat is closer than ever to
TM
optics(patent pending).
wired systems
l Built-in link quality indicators enable installer to checksignalquality without physicallyapproaching the control
panel, thus making installation faster and easier.
l Robust housing with r ecessed window.
l Smart anti masking distinguishes between masking spray and rain.
l Alarm LED is visible in sunlight.
l Automatic termination of walk-test after 15 minutes.
l Microprocessor-controlled temperature compensation.
l Immunity to pets weighing up to 18 Kg (40lb), not pet alley– see Table 1
l Built-in swivel bracket
TM
) operating in true Quad configuration ( patented) with true motion recognition (TMR)
Figure 1.
General View
2. INSTALLATION
2.1. Installation
A. Bracket installation (see Figure 2). Fix the bracket firmly on a stable wall or pillar. The orientation of the fixed bracket must be as parallel as possible
to the surveyed ground surface.
B. Adjust the detector's horizontal and vertical angles(see Figure 3), according to the surveyed ground surface. The vertical angle indicator position
for various installation height and coverage distance combinations is detailed in Table 1 (the information refers to a relatively flat surveyed area.
Verify the correct installation by walk-test).
C. Fasten the detector to the bracket (see Figure 2 step 4).
Table 1 - Vertical Adjustment Reference
Mounting Heigh t Coverage Distance
2m / 6.7ft 4m / 13ft 6m / 20ft 8m / 26ft 10m / 33 ft 12m / 39 ft
3.0m / 10 ft - 1 2 2 3 3
2.5m / 8 ft 1 1 2 3 4 4
2.0m / 7 ft 1 2 3 4 5 5
1.5m / 5 ft 2 3 4 5 5 -
Note: The grayed-in cellsin T able 1 are the installation alternatives recommended for further reducing false alarms from pets.
D-304046 TOWER-20 PG2 Installation Instructions 1

Corr ect Installation
Incorrect Installation
A. Mark drilling point B. For wall tamper C. Drill
D. Fasten
E. Three long screws F. Two short screws
Note: The 2 screw holes enable adjustment of the bracket on the
wall, if needed, following the walk test.
Figure 2 - Installation
HORIZONT AL ADJUSTMENT (-45° to +45°)
VERTICAL ADJUSTMENT ( 0° to -10° in 2.5° clicks / steps)
D-304046 TOWER-20 PG2 Installation Instructions 2

COVER CLOSURE
1. Release locking 2. Adjust 3. Lock 4. Release locking 5. Adjust
6. Lock 7. Turn cover and push slider 8 & 9. Put back cover 10. Secure with screw
A. Vertical angle steps
Figure 3 - Adjustment and Cover Closure
2.2. Battery Insertion
It is recommended to perform the first batteries insertion on a flat surface (see F igure 4). After battery insertion, the LED will flash for 60 seconds and
then the detector will enter a 15 minutes' local diagnostic mode.
A. Tamper switch B. Press firmlyto release the bracket C. 3 screws
Figure 4 – Battery Insertion
2.3. Enrollment
Refer to the PowerMaster control panel's Installer Guide and follow the procedure under the "02:ZONES/DEVICES" option of the Installer Menu.
Ageneral description of the procedure is provided in the following flow chart.
Step 1 Step 2 Step 3 Step 4
Enter the Installer menu and select
“02:ZONES/DEVICES”
02:ZONES/DEVICES
Step 5 Step 6 Step 7
Configure Location, Zone Type &
Chime parameters
D-304046 TOWER-20 PG2 Installation Instructions 3
Select "ADD NEW DEVICE"
See Note 1
ð
ADD NEW DEVICES
MODIFY DEVICES
Enter PARTITIONS.
See Note 2
Enroll the device (see Figure 5) or
enter the device ID
ð
ENROLL NOW or
6
ENTR ID:XXX-XXXX
Assign partitions to the detector by
pressing the ,
and/or buttons on the
Select a detector number for the
new flood detector
ð
Z14:Motion Sens
ID No. 130-XXXX
ð