Visonic TOWER20MCW Users Manual

TOWER 20 AM MCW
Outdoor Wireless Octa-PIR Detector with Anti-Mask
1. INTRODUCTION
Detector's Features
Patented 8 independent PIR matrix (Octa-PIR) with true motion recognition (TMR) processing for each of the 8 PIR detectors and central motion processing - can distinguish between a moving intruder and moving trees and bushes.
Immunity to pets weighing up to 18 Kg (40lb), not pet alley.
Smart protection against snow, rain, dust, wind and direct
sunlight.
Tamper protection when the detector is opened, removed from mounting surface or removed from bracket.
Alarm LED is visible under strong sunlight.
DRAFT
Day/night recognition for sophisticated operation.
Robust housing.
Anti masking mode.
Coverage: 12 meters / 90º.
2. SPECIFICATIONS
OPTICAL Sensors: 8 dual-element Pyroel ectric sensors provide 16 element array. Max. Coverage: 12 meters / 90º. Detector Technology: 8 independent PIR
detectors
Pet- immune: Up to 18Kg ?? (40lb. ??) ELECTRICAL
Input Power: Two 3V CR123A Lithium batteries. Battery life: 3 years (for typical use).
WIRELESS Frequency (MHz): 315, 433, 868.95. Communication protocol: PowerCode
MOUNTING Mounting type: Wall mounting Mounting height: 1.8 to 3.0 meters Vertical adjustment: 0º to -10º, in 2.5º steps Horizontal adjustment: -45º to +45º, in 5º steps
TOP VIEW
90°
SIDE VIEW OF
EACH DETECTOR
2.4 m (8 ft)
close curtains
3 6 9 12 m0
10 20 30 40 ft
Fig. 2 - Coverage pattern
3. INSTALLATION
3.1 DIP Switches Setup
Remove the 2 detector's bottom covers (see Figure 3. steps 4-8) to gain access to the DIP switches. Set the DIP switches according to the following table:
DIP
Function Description Default
SW #
1
2
3 4
Alarm LED OFF/ON
24H / night only
PIR signal processing modes
OFF: Motion and masking alarm LED is disabled (OFF). ON: Motion and masking alarm LED is enabled (ON). OFF: Motion alarms are always enabled (24 hours). ON: Motion alarms are enabled only at dark (night).
TBD. ??? TBD??
OFF
OFF
3.2 Installation
See Figure 3.
3.3 Adjustments
Perform detector's horizontal adjustment, vertical adjustment and final closure, as shown in Figure 4.
3.4 Test
A. Set the detector in Walk-Test mode, as follows:
Open the detector bottom cover (see Fig. 3, steps 4 - 6) and then close it. The LED will flash for 30 seconds and then the detector will enter into 15 minutes walk-test mode.
Note: The detector automatically enters into 15 minutes walk­test mode after battery installation or Tamper switch recovery.
B. Walk into the detector's field of view at the expected far edge
of the coverage area. Verify that each time your motion is detected the LED lights for 2 seconds and the control panel receives the alarm. If required, perform detector's horizontal / vertical readjustments.
Important! Instruct the user to perform walk test at least once a week, to verify proper operation of the detector.
C.
Place a piece of cardboard on the detector’s front side, to deliberately mask the optical window. After 30 seconds, the LED should flash for 5 seconds (see table below) and the alarm control panel should receive the masking alarm.
D. Remove the masking from the detector’s front side. The LED
should extinguish (after a few seconds).
LED operation:
First 30 sec after battery insertion or closing the detector cover Tamper switch open ON 2 sec. Mask detection (*) (**) fast flashing 5 sec. PIR detection (**) ON 2 sec.
* The LED flashes fast continuously during walk-test mode. ** LED ON/OFF control by DIP switch #1 (see par. 3.1).
Installation Instructions
LED
Figure 1 - TOWER 20 AM MCW
ENVIRONMENTAL Operating Temperature: -30°C ??? to 60°C Storage Temperature: -30°C to 60°C Humidity: 95% max. White light immunity: Above 6500 lux
PHYSICAL Dimensions (height x length x width:
157x147x124mm (6-3/16 x 5-13/16 x 4-7/8").
Weight: .......
Color: White or off-white gray ?? STANDARDS COMPLIANCE
Designed to Comply with EN 50131-2-2 "environmental class IV".
EMI Immunity: CE and EN 50131 (min. 20 V/m 10 to 1000 MHz, min. 10 V/m 1Ghz to 2Ghz).
US Patents: 7250605, 6818881, 5693943
Event LED Operation
slow flashing
D-301620 1
Mark Fasten
Drill
1
For Tamper switch
4 5
2
Mounting on bracket
Battery inse rtion
6
3
7
A
98
10 11
B
Figure 3 - Installation
2 D-301620