Visonic TOWER 20 AM User Manual

TOWER 20 AM
Outdoor Octa-Quad Mirror Detector with Anti-Mask [Grade 3]
1. INTRODUCTION
Detector's Features
true Quad configuration with true motion recognition (TMR) processing for each of the 8 PIR detectors and central motion processing - can distinguish between a moving intruder and moving trees and bushes.
Advance Obsidian Black Mirror High protection against snow, rain, dust, wind and direct sunlight. Tamper protection against opening and removal from wall.
TM
optics (patent pending).
Alarm LED is visible in sunlight.
Low voltage detection
Self test Day & night or night only setting.
Robust housing with recessed window.
Smart anti masking can distinguish between masking spray and rain.
Immunity to pets weighing up to 18 Kg (40lb), not pet alley.
Built in swivel bracket.
2. SPECIFICATIONS
OPTICAL Black Mirror Max. Coverage: At
least 12 meters (40 ft)/90º. Detector Technology: 8 independent quad PIR detectors operating in true Quad configuration.
Pet- immune: Up to 18Kg (40lb.) ELECTRICAL Input Power: 8-16VDC Standby Current:
15mA@12VDC. Supply Current: 70 mA max. (red and yellow LEDs light steadily) Low Voltage Detection: If input voltage is below 7.5 VDC
Outputs:
Alarm output: Solid State
Relay. NC, 100 mA / 30 V, 35 ohm maximum internal resistance. (see Table 4).
Trouble output: Solid State Relay. NC, 100 mA / 30 VDC, 35 ohm maximum internal resistance.
9m (30ft)
6m (20ft)
3m (10ft)
3m (10ft)
6m (20ft)
9m (30ft)
2.4 m (8 ft)
Fig. 2 - Coverage pattern
(see Table 4).
TOP VIEW
90°
0
36912 m0
10 20 30 40 ft
SIDE VIEW OF EACH DETECTOR
36912 m0
10 20 30 40 ft
Tamper output: NC switch, 50mA / 30 VDC. "Open" by opening detector’s cover or removing it from mounting surface.
Masking detection delay: 120 sec. Remote LED enable input (TST): High impedance input. Affects LEDs operation only if internal LEDs selector is set to OFF. MOUNTING Mounting type: Wall mounting Mounting height: 1.5 - 3.0 meters (5 – 10 ft) Vertical adjustment: 0º to -10º, in 2.5º steps. Horizontal adjustment: -45º to +45º, in 5º steps.
ENVIRONMENTAL Operating Temperature: -35°C to 60°C (-31°F to 140°F) Storage Temperature: -35°C to 60°C (-31°F to 140°F) Humidity: 95% max. White light immunity: Above 25000 lux
PHYSICAL Dimensions (height x length x width: 157x147x124mm (6-3/16 x 5-13/16
x 4-7/8").
Weight: 600g (21 oz) Color: White or gray
STANDARDS COMPLIANCE
(FCC) CFR 47 Part 15, EN 50130-4, EN 60950, EN 50130-5 Environmental class IV. IP 55. US Patents: 7250605, 6818881, 5693943. Other patents pending.
3. INSTALLATION
3.1 DIP Switches Setup
Remove the 2 detector's bottom covers (see Figure 3, steps 4-8) to gain access to the DIP switches. Set the DIP switches, according to Table 1:
DIP SW # Function Description Default
LEDs
1
OFF/ON
PIR
2
Sensitivity AM OFF /
3
ON
Masking event opens
4
Alarm relay (EN standard)
* Switching from OFF to ON resets the detector for a stabilization
period of 60 sec. and causes the detector to re-adapt to its current surroundings. Remain at a distance of at least 0.5 m (1.5 ft.) from the detector to prevent disruption of this process.
** Use ON for EN approved control panels / installations. However,
many installers prefer not to have the ALARM relay opened on a masking event.
Table 1 – DIP Switch Setup
OFF: Motion and masking alarm LEDs
is disabled (OFF). Can be enabled by TST input (Active "low") ON: Motion and masking alarm LEDs is enabled (ON).
OFF: Normal PIR sensitivity. ON: High PIR sensitivity. OFF: AM off ON: AM on
* OFF: masking event reported to panel
as TROUBLE (Trouble relay opens). ON: masking event reported to panel as TROUBLE and ALARM (EN standard). Trouble and Alarm relay opens at the same time.**
ON
OFF
ON
OFF
3.2 Installation
Bracket installation (see figure 3) – firmly fix the bracket on a stable wall or pillar. The orientation of the fixed bracket should be as parallel as possible to the surveyed ground surface.
3.3 Wiring
Perform wiring (see figure 3, step 8 - 10)
3.4 Adjustments
Adjust detector's horizontal and vertical angles (see Fig. 4, steps 1 - 6), according to the surveyed ground surface and close the detector, as shown in Fig. 3, steps 7 - 12. The vertical angle indicator position for various installation height and coverage distance combinations is detailed in Table 2 (the information refers to a relatively flat surveyed area. however, in any case the vertical adjustment should be verified by walk-test).
Mounting
Height
3.0m / 9,8 ft - 1 2 2 3 3
2.5m / 8,2 ft 1 1 2 3 4 4
2.0m / 6.7 ft 1 2 3 4 5 5
1.5m / 4.9 ft 2 3 4 5 - -
3.5 Test
A. The detector enters Walk-Test mode after one of the following
occurs:
o The 60-second stabilization period ends. o DIP-SW1 position changes from OFF to ON. o TST input state changes from OFF to ON.
Installation Instructions
Table 2 - Vertical Adjustment Reference
Coverage Distance
2m / 6.7ft 4m / 13ft 6m / 20ft 8m / 26ft 10m / 33ft 12m / 39 ft
Figure 1 -
TOWER 20 AM
LEDS
D-301524 1
NOTE: Regardless of the DIP-SW1 and TST input settings, the
A
Alarm and AM LED indications are enabled in Walk-Test mode. Crossing a single beam causes the red LED to double-blink.
B. Walk into the detector's field of view at the expected far edge of the
coverage area. Verify that each time your motion is detected the red LED lights for 2 seconds and the control panel receives the alarm. If required, perform detector's horizontal / vertical readjustments.
Important! Instruct the user to perform walk test at least once a week, to verify proper operation of the detector.
C. Place a piece of cardboard on the detector’s front side, to
deliberately mask the optical window. After 2 minutes, the yellow LED should light (see Table 3) and the alarm control panel should receive the masking alarm.
D. Remove the masking from the detector’s front side. The LED
should extinguish (after about 30 seconds).
3.6 Cover Closure (see Fig. 4, steps 7 - 10)
Table 3 – LED Operation
Event / status Indication
Low voltage Red flashing Warm-up (60sec.) Yellow + Red flashing alternately Self-test failure Yellow + Red flashing simultaneously AM detection Yellow ON ALARM Red ON for 2 sec. Crossing Beam during Walk-Test
Event / status
Complete power failure Open Open
Standby Closed Closed
Low voltage Open Closed
Self-test failure Open Closed
AM detection DIP-SW4 = ON Open Open
AM detection DIP-SW4 = OFF Open Closed
Alarm Closed Open for 2 sec.
Red Double blink
Table 4 – Relay Outputs
Trouble
Tamp e r s w itch
Relay Output
larm
Mark
5
For wall Tamper switch
Bracket fastening (3 cable routing options)
7
31 2
6
Wiring
10
Drill
Note
The 2 screw holes enable adjustment of the bracket on the wall, if needed as a result of the walk test.
DIP switches
4
Fasten
(3 long screws)
Press firmly
to release the
bracket
OFF ON
1
2
3
4
SPARE
(2 short screws)
24-HOUR
TAMPER
12
VDC
8
9
ZONE
ALARM CO NTROL PANEL
TEST
SWITCH
(OPTION)
BURGLAR ZONE N.C.
24 HOUR TROUBLE ZONE N.C.
Figure 3 - Installation
2 D-301524