Visonic SR-740 HEX PG2 Installation Instructions Manual

SR-740 HEX PG2

Siren and strobe light activation: When an identified event message is received from the compatible
to local authorities requirements, or until the system is disarmed, whichever occurs first.
Fully Wireless PowerG Outdoor Siren
Installation Instructions

1. INTRODUCTION

The SR-740 HEX PG2 is a fully wireless outdoor siren for installation in areas in which wiring action is difficult or impossible. The siren is compatible with PowerG control panels.
PowerG alarm system, the siren activates its sounder & strobe light.
Notes:
The sounder is activated for a predefined "Bell Time" (refer to the control panel Installer Guide), according to local authorities requirements, or until the system is disarmed, whichever occurs first. The strobe light operates as described in the PowerG Installer Guide.
Tamper indication: In case of tamper while the system is armed, the siren transmits the message to the alarm system and then the alarm system determines whether the siren should be activated or not. If the siren does not receive an acknowledge message from the alarm system, the siren will function independently.
Siren and strobe light activation: When an identified event message is received from the compatible PowerG alarm system, the siren activates its sounder & strobe light.
Notes:
The sounder is activated for a predefined "Bell Time" (refer to the control panel Installer Guide), according
The strobe light operates as described in the PowerG I
Tamper indication: In case of tamper while the system is armed, the siren transmits the message to the alarm system and then the alarm system determines whether the siren should be activated or not. If the siren does not receive an acknowledge message from the alarm system, the siren will function independently.
Low battery voltage alert: When the battery voltage is low, a low battery message is sent to the alarm system. After the low voltage message delivery, at least 2 siren alarms are possible before the siren is totally inactive.
Power Supply Options: Non-rechargeable battery. Optional - two non-rechargeable batteries.
Sound Types: Burglar (between 1400Hz - 3200Hz), fire, gas/Co and flood.
Entry/Exit: Exit delay beeps sound once the user has armed the system. Entry delay beeps sound once the user has entered the protected
area. (Entry/exit beeps can be enabled / disabled from the control panel Installer menu.)
Squawk indications: Squawk (beep) sounds can be used to indicate alarm system arming (1 squawk) and disarming (2 squawks) by a keyfob (squawk can be enabled from the control panel User Settings menu).
Strobe Light Color: The siren can be purchased with red, blue, amber or transparent lens, according to the desired strobe light color.
Siren activity LED: A flashing LED (optional, at the bottom of the siren front panel) indicates siren activity (can be disabled by the control
panel)
Double Tamper protection: When the siren front panel is removed or when the siren is removed from the wall, a tamper alarm is sent to the alarm system.
IMPORTANT! The SR-740 HEX PG2 siren must be installed on the wall in a vertical position with the screw pointing to the floor only, as illustrated in Figure 1. The importance of correct positioning of the SR-740 HEX PG2 is to enable the siren to function as a waterproof device.
2-way full supervision
The siren is a fully supervised, 2-way communication device. It includes a receiver, to receive event messages from the alarm system, and a transmitter, to periodically transmit its status signal to the alarm system.
nstaller Guide.
Self-test feature
Upon pressing the self-test switch, a siren functional check is performed - low level sounds and flashing light indicate that the siren is
serviceable.
1 - External View
Fig.
D-304920 SR-740 HEX PG2 Installation Instructions
1

2. INSTALLATION

1. Open the 2 plastic screw covers.
A. Mounting surface.
2. Using a Philips screwdriver, release the 2 screws.
B. For tamper.
3. Hang back the unit with a screw on the mounting surface.
C. Self-Test button.
4. Open the cover at an angle of 90°.
D. Enroll button.
5. With the cover at an angle of 90°, push the cover downward on its axle until locked.
E. Primary battery.
6. Mark for drilling.
F. Battery connector..
7. Drill 6 holes.
8. Fasten with 6 screws.
9. Use the level to horizontally adjust the unit to the correct position.
10. Using a screwdriver, release the catch.
11. Open the battery cover.
12. Connect the two connectors in their respective sockets.
13. Insert the battery and connect the battery connector.
2.1. Installation
Caution! Risk of explosion if battery is replaced by an incorrect type. Dispose of used battery according to manufacturer's instructions.
Figure 2: Installation
2.2. Closing the Cover
Figure 3: Closing the Cover
2 D-304920 SR-740 HEX PG2 Installation Instructions
ull the cover upward
1. P
2. Close the cover at an
e of 90°.
angl
3. Fasten the 2 screws.
4. Close t
A Mounting surface.
he 2 plastic screw
covers.
Loading...
+ 2 hidden pages