Visonic SR-720B PG2 Installation Instructions Manual

SR-720B PG2
Wireless PowerG Indoor Siren
1. INTRODUCTION
1. INTRODUCTION
1. INTRODUCTION1. INTRODUCTION
The SR-720B PG2 is a full 2-way wireless PowerG indoor siren, designed for installation in areas in which wiring action is difficult or impossible.
Features
Siren and strobe light activation: When an identified event message is received from the compatible PowerG alarm system, the siren activates its sounder & strobe light.
Notes:
The sounder is activated for a predefined "Bell Time" (refer to
the control panel Installer Guide), according to local authorities requirements, or until the system is disarmed, whichever occurs first.
The strobe light operates as described in the control panel
Installer Guide.
Tamper indication: In case of tamper while the system is armed, the siren transmits the message to the alarm system and then the alarm system determines whether the siren should be activated or not. If the siren does not receive an acknowledge message from the alarm system, the siren will function independently.
Low battery voltage alert: When the battery voltage is low, a low battery message is sent to the alarm system. After the low voltage message delivery, at least 2 siren alarms are possible before the siren is totally inactive.
2222.
. INSTALLATION
INSTALLATION
. .
INSTALLATIONINSTALLATION
Power Supply: Non-rechargeable battery.
Sound Types: Burglar (between 1400Hz - 3200Hz), fire,
gas (CO) and flood.
Entry/Exit: Exit delay beeps sound once the user has armed the system. Entry delay beeps sound once the user has entered the protected area. (Entry/exit beeps can be enabled / disabled from the control panel Installer Mode.)
Squawk indications: Squawk (beep) sounds can be used to indicate alarm system arming (1 squawk) and disarming (2 squawks) by a keyfob (squawk can be enabled from the control panel User Settings).
Double Tamper protection: When the siren front panel is removed or when the siren is removed from the wall, tamper alarm is sent to the alarm system.
2-way full supervision
The siren is a fully supervised, 2-way communication device. It includes a receiver, to receive event messages from the alarm system, and a transmitter, to periodically transmit its status signal to the alarm system.
Fig. 1 - External View
Self-test feature
Upon pressing the self-test switch, siren functional check is performed - low level sounds and flash light indicate that the siren is serviceable.
2.1 Installation
1. Open plastic cover screw.
2. Using Philips screwdriver, remove screw and remove cover.
3. Mark for drilling.
4. Drill 4 holes. 5 Fasten with 4 screws.
A. Mounting surface. B. For back tamper screw.
Figure 2: Installation
D-305640 SR-720B PG2 Installation Instructions 1
2.2 Battery Pack Insertion
A. Battery connector
A
B
B. Enroll button C. Self-test switch
2
C
CAUTION! Risk of explosion if battery is replaced by an incorrect type. Dispose of used battery according to manufacturer's instructions.
2. Connect the battery connector and insert the battery.
Figure 3: Battery Pack Insertion
2.3 Cover Closure
See Figure 4.
1. Put back the plastic cover.
2. Secure with screw.
1
1. Connect the two connectors in their respective sockets.
3333. ENROLLMENT
. ENROLLMENT
. ENROLLMENT. ENROLLMENT
Refer to the PowerMaster panel's Installer Guide and follow the procedure under the "02:ZONES/DEVICES" option of the Installer Mode. A general description of the procedure is provided in the following flow chart.
Step 1 Step 2 Step 3 Step 4
Enter the Installer Mode and select
“02:ZONES/DEVICES”
02:ZONES/DEVICES
Select “ADD NEW DEVICEs” See Note 1
ADD NEW DEVICES
Step 5 Step 6 Step 7 Step 8
Configure Location, Zone Type & Chime parameters
SR1.LOCATION SR1.ZONE TYPE SR1.SET CHIME
MODIFY DEVICES
Enter “PARTITIONS”. See Note 2
SR1.PARTITIONS
means scroll and select
Notes: [1] If the siren is already enrolled you can configure the siren parameters and assign partitions via the MODIFY DEVICES option – see Step 2. [2] PARTITIONS will appear only if PARTITIONING was previously enabled in the panel (for further details, see "Partitioning" in the PowerMaster
Installer Guide).
[3] When there is an alarm, the siren will sound regardless of partition assignment.
Enroll the device or enter the device ID
ENROLL NOW or
ENTR ID:XXX-XXXX
Assign partitions to the siren by pressing the , and/or buttons on the
panel
SR1:P1 P2 P3
Figure 4 - Cover Closure
Select the siren number for the new siren
SR1:Siren Indoor
ID No. 400-XXXX
Select the “DEV SETTINGS” option and refer to the section below to configure the siren parameters.
SR1:DEV SETTINGS
2 D-305640 SR-720B PG2 Installation Instructions