SR-720B PG2
Wireless PowerG Indoor Siren
1. INTRODUCTION
1. INTRODUCTION
1. INTRODUCTION1. INTRODUCTION
The SR-720B PG2 is a full 2-way wireless PowerG indoor siren,
designed for installation in areas in which wiring action is difficult
or impossible.
Features
• Siren and strobe light activation: When an identified event
message is received from the compatible PowerG alarm
system, the siren activates its sounder & strobe light.
Notes:
The sounder is activated for a predefined "Bell Time" (refer to
the control panel Installer Guide), according to local authorities
requirements, or until the system is disarmed, whichever
occurs first.
The strobe light operates as described in the control panel
Installer Guide.
• Tamper indication: In case of tamper while the system is
armed, the siren transmits the message to the alarm system
and then the alarm system determines whether the siren
should be activated or not. If the siren does not receive an
acknowledge message from the alarm system, the siren will
function independently.
• Low battery voltage alert: When the battery voltage is low, a
low battery message is sent to the alarm system. After the low
voltage message delivery, at least 2 siren alarms are possible
before the siren is totally inactive.
2222.
. INSTALLATION
INSTALLATION
. .
INSTALLATIONINSTALLATION
Installation Instructions
• Power Supply: Non-rechargeable battery.
• Sound Types: Burglar (between 1400Hz - 3200Hz), fire,
gas (CO) and flood.
• Entry/Exit: Exit delay beeps sound once the user has armed
the system. Entry delay beeps sound once the user has
entered the protected area. (Entry/exit beeps can be enabled /
disabled from the control panel Installer Mode.)
• Squawk indications: Squawk (beep) sounds can be used to
indicate alarm system arming (1 squawk) and disarming (2
squawks) by a keyfob (squawk can be enabled from the control
panel User Settings).
• Double Tamper protection: When the siren front panel is
removed or when the siren is removed from the wall, tamper
alarm is sent to the alarm system.
• 2-way full supervision
The siren is a fully supervised, 2-way
communication device. It includes a
receiver, to receive event messages
from the alarm system, and a
transmitter, to periodically transmit its
status signal to the alarm system.
Fig. 1 - External View
Self-test feature
Upon pressing the self-test switch, siren functional check is
performed - low level sounds and flash light indicate that the siren
is serviceable.
2.1 Installation
1. Open plastic cover screw.
2. Using Philips screwdriver, remove screw and remove cover.
3. Mark for drilling.
4. Drill 4 holes.
5 Fasten with 4 screws.
A. Mounting surface.
B. For back tamper screw.
Figure 2: Installation
D-305640 SR-720B PG2 Installation Instructions 1

2.2 Battery Pack Insertion
A. Battery connector
A
B
B. Enroll button
C. Self-test switch
2
C
CAUTION!
Risk of explosion if battery is replaced by an incorrect type.
Dispose of used battery according to manufacturer's instructions.
2. Connect the battery connector and insert the battery.
Figure 3: Battery Pack Insertion
2.3 Cover Closure
See Figure 4.
1. Put back the plastic cover.
2. Secure with screw.
1
1. Connect the two connectors in their respective sockets.
3333. ENROLLMENT
. ENROLLMENT
. ENROLLMENT. ENROLLMENT
Refer to the PowerMaster panel's Installer Guide and follow the procedure under the "02:ZONES/DEVICES" option of the Installer Mode.
A general description of the procedure is provided in the following flow chart.
Step 1 Step 2 Step 3 Step 4
Enter the Installer Mode and select
“02:ZONES/DEVICES”
02:ZONES/DEVICES
Select “ADD NEW DEVICEs”
See Note 1
ADD NEW DEVICES
Step 5 Step 6 Step 7 Step 8
Configure Location, Zone Type &
Chime parameters
SR1.LOCATION
SR1.ZONE TYPE
SR1.SET CHIME
MODIFY DEVICES
Enter “PARTITIONS”.
See Note 2
SR1.PARTITIONS
means scroll and select
Notes:
[1] If the siren is already enrolled you can configure the siren parameters and assign partitions via the MODIFY DEVICES option – see Step 2.
[2] PARTITIONS will appear only if PARTITIONING was previously enabled in the panel (for further details, see "Partitioning" in the PowerMaster
Installer Guide).
[3] When there is an alarm, the siren will sound regardless of partition assignment.
Enroll the device or enter the
device ID
ENROLL NOW or
ENTR ID:XXX-XXXX
Assign partitions to the siren by
pressing the ,
and/or buttons on the
panel
SR1:P1 P2 P3
Figure 4 - Cover Closure
Select the siren number for
the new siren
SR1:Siren Indoor
ID No. 400-XXXX
Select the “DEV SETTINGS”
option and refer to the section
below to configure the siren
parameters.
SR1:DEV SETTINGS
2 D-305640 SR-720B PG2 Installation Instructions