Visonic SPY-1, SPY-RTE-A, SPY-RTE-B User Manual

SPY 1, 2, 3, 4
SPY 1, 2, 3, 4
SPY 1, 2, 3, 4SPY 1, 2, 3, 4
1. INTRODUCTION
1. INTRODUCTION
1. INTRODUCTION1. INTRODUCTION
Ultra-miniature
Reliable
Trouble free
Four different models for different applications.
Virtually unnoticeable when installed
Fast, easy installation
In-ceiling or in-wall installation
Special anti-false alarm features:
−−−− 2-step built-in pulse counter
−−−− Light rejection filter to reject visible light variations
−−−− Dual-element low-noise pyroelectric detector
RF immunity up to 1000 MHz
N/C silent relay output
Low 12.5 mA current drain @ 12 VDC
10-14 VDC supply voltage
The new SPY series features the smallest passive infrared (PlR) detectors of their type presently marketed. Models are designed for in-wall or in-ceiling installation, or behind the wall (or ceiling) mounting. The only visible part of the SPY after installation is the ultra miniaturized lens itself.
SPY 1 - Long Range SPY 2 - Medium Angle SPY 3 - Wide Angle
False alarms caused by environmental disturbances are virtually eliminated by a combination of light rejection filter and pyro­electric low-noise detector. The medium angle, wide angle and curtain SPYs have the additional protection of built-in two-step pulse counting. With careful attention to installation site and periodic walk-testing, Visonic Ltd. SPY PlR detectors will give reliable, long-life, trouble-free service.
Models available: SPY 1: Long Range. Provides narrow angle corridor pattern with
maximum coverage area of 11 m/17° (35 ft/17°). SPY 2: Medium Angle. Provides 3 double beams in a single
detection layer with maximum coverage area of 8 m/50° (25 ft/50°)
SPY 3: Wide Angle. Provides 6 double beams in a single detection layer with maximum coverage area of 8 m/100° (25 ft/100°).
SPY 4: Curtain. Provides a solid curtain with maximum coverage pattern of 2 m width x 4 m height (6 x 12 ft).
SPY RTE-A: Special request-to-exit model, relay output. SPY RTE-B: Request-to-exit model, open collector output.
Installation Instructions
SPY 4 - Ceiling Mounted Curtain
Note: These units are not designed for pet alley use.
2. SPECIFICATIONS
2. SPECIFICATIONS
2. SPECIFICATIONS2. SPECIFICATIONS
OPTICAL - Detection Patterns SPY 1
SPY 2
SPY 3
SPY 4
ELECTRICAL Voltage: 10 - 14 VDC
Current: 12.5 mA @ 12 VDC
Long Range; narrow angle corridor pattern. Coverage Area: max. 11 m/17° (35 ft/17°)
Medium Angle; 3 double beams in a single detection layer. Coverage Area: max. 8 m/50° (25 ft/50°)
Wide Angle; 6 double beams in a single detection layer. Coverage Area: max. 8 m/100° (25 ft/100°)
Curtain; solid curtain pattern. Coverage pattern: max. 2 m wide x 4 m high (6 x 12 ft)
SPY 4 - Wall Mounted Curtain
Alarm Output SPY 1, 2, 3, 4 and SPY RTE-A: Normally closed (fail-safe)
contacts. Rating: 0.1 A resistive / 30 VDC. 18-ohm resistor in series with contacts.
SPY RTE-B: Open collector output, 50 mA maximum Alarm Period SPY 1, 2, 3, 4: 2-10 seconds SPY RTE-A and B: 1-2 seconds Detector: Dual-element, low-noise pyroelectric detector Pulse Counter SPY 2, 3 and 4: Factory set to 2 pulses alternate polarity
SPY-1 and SPY RTE-A and B: 1 pulse
DE1151 SPY 1, 2, 3, 4 Installation Instructions 1
INSTALLATION
Suitable for wall or ceiling installation, and available with both a collar and a front or rear mounting plate, depending on the model.
ENVIRONMENTAL Operating Temperature: 0°C to 50°C (32°F to 122°F) Storage Temperature: -20°C to 60°C (-4°F to 140°F)
3. INSTALLATION
3. INSTALLATION
3. INSTALLATION3. INSTALLATION
RFl Protection: Greater than 10 V/m to 1000MHz
PHYSICAL Dimensions: Diameter: 19 mm (0.75 in) Length: 70 mm (2.75 in) Weight: 30 g (1.1 oz) Color: White
ATTENTION: Whichever model of SPY PIR detector you are installing, please observe the following:
1. Never touch the lens. Whenever you are handling the detector, hold it firmly by the collar, mounting plate, or sides.
2. Splice or solder the wires from the control panel to the SPY detector. Do not attach by only twisting wires together.
3. Insulate each wire individually. Do not permit uninsulated wires to touch each other.
4. During the wiring operation, be careful to place the detector so that the lens is protected.
5. Do not open the detector from either the front (lens end) or the back (wire end).
FAILURE TO OBSERVE THESE PROCEDURES MAY INVALIDATE YOUR WARRANTY.
3.1 Choosing the Right Location
SPY PIRs can be installed in a wall or ceiling and are available with both a collar and a front/rear mounting plate. Three of the models (SPY 1, 2 and 4) can be installed with the mounting plate in the front or rear of the detector unit, as required. The choice of method depends upon the type of wall or ceiling and the degree to which the detector should be unnoticed.
SPY Models SPY 1, SPY 2 and SPY 4 are provided with both a collar and a front/rear mounting plate.
SPY 3 is provided with a fixed mounting plate for front- of-the­wall installation.
1. Select the mounting location so that the expected motion of
an intruder will cross the coverage pattern.
2. When wall mounted, the SPY should be installed parallel to
the floor for maximum coverage. Recommended mounting height: between 80 cm and 1.35 m (2.5 and 4.5 ft).
3. The curtain detector SPY 4 can be mounted in the ceiling or in
the wall. When mounting in the wall it should be installed parallel to the floor. Maximum ceiling height: 4 m (12 ft).
4. Always install the unit into a firm and stable surface, and
assure that there are no moving objects within its field of view.
Remember: Passive infrared detectors are sensitive to changes in infrared energy caused by an object moving across the unit's field of view. Detection depends on the difference between the amount of infrared energy transmitted by the moving object and the temperature of the background.
It is therefore recommended that the detector be aimed toward the coolest place in the area to be protected, in order to obtain maximum sensitivity in installations where high ambient tempera­tures are expected. Do not aim the detector toward areas containing hot water pipes or windows, which might cause problems in the operational efficiency of PIR detectors.
BEFORE YOU START: Do not touch the lens. Solder or splice wire connections. Insulate wires individually so that they cannot touch.
3.2 Installation with Collar
(MODELS SPY 1 and 2)
1. Drill a 22 mm (7/8 in.) hole in the wall.
2. Hold the detector unit by the sides. Carefully put the collar on
the detector and adjust its
position so that the front of the detector and the collar are aligned (Fig. 1).
3. Fish the wiring from the control panel through the hole and connect to the detector unit as described under WIRING.
4. Feed the wiring into the prepared hole.
5. Orient the detector unit so
that the mark on the front faces up (Fig. 1).
6. With your fingers on the outer edge of the collar, push the detector unit, rear end first, into the hole until the retaining collar is seated securely.
Figure 1 - Installation with
Collar, Models SPY 1, SPY 2
3.3 Front-of-Wall Installation
(MODELS SPY 1 and 2)
1. Drill a 24 mm (15/16 in) hole in the wall.
2. Hold the detector unit by the sides and put it, lens end first,
into the mounting plate (Fig. 2A).
3. Adjust the detector unit in the mounting plate so that the front of the detector extends a minimum distance from the wall.
4. Place the locking ring over the rear end of the detector unit and move it over the tabs of the locking plate until the detector unit is absolutely stable in the mounting plate (Fig. 2A).
5. Fish the wiring from the control panel through the hole and connect to the detector unit as described in WIRING.
6. Feed the wiring into the prepared hole.
7. Prepare the mounting plate screw holes on a horizontal line,
making sure that the mark on the front of the detector unit is facing up (Fig. 2B).
8. Insert the detector unit, rear end first, into the hole with the mark on the front facing up (Fig. 2B) and secure the mounting plate to the wall with the screws provided.
Figure 2 (A & B) - Front of Wall Installation, Models SPY 1 and 2
3.4 Back-of-Wall Installation
(Models SPY 007.1, 007.2)
1. Drill a 19 mm (3/4 in.) hole in the wall.
2. Hold the detector unit by the sides and put it, lens end first,
into the mounting plate (Fig. 3A).
3. Adjust the detector unit in the mounting plate according to the thickness of the wall. When installed, the lens end of the detector should extend about 1 mm (0.05 in.) from the wall.