1111. INTRODUCTION
. INTRODUCTION
. INTRODUCTION. INTRODUCTION
SPD-1000 is a fully supervised wireless detector, designed for protection of paintings, sculptures and other artwork, in museums, galleries, churches, private artwork collections, etc.
Figure 1 - Integration of SPD-1000 in an Alarm System
When someone tries to touch or remove the secured object, to which the detector is attached, an identifiable alarm signal is transmitted to alert security personnel. Identifiable signals include: low battery voltage alert, low severity alarm (slight touch) and high severity alarm (repetitive touch, strong touch or removal).
2222. SPECIFICATIONS
. SPECIFICATIONS
. SPECIFICATIONS. SPECIFICATIONS
Movement Detection Sensitivity: 0.1 mm Transmission Frequency (MHz): 315 or 433.92 Compatible Receivers: PowerArt / MCR-308, SpiderAlert
SR-500ER / SCP-532ER / SR-520ER. Overall Message Length: 36 bits, including 24-bit identification
code, pulse width modulation.
Supervision
(Europe) Power Source: Two 3V/160 mAh Lithium batteries, GP CR-2025,
or equivalent.
Current Consumption: 8 µA (STBY), 8 mA (transmission) Battery Life: 5 years under normal installation conditions
Transmission:
Every 60 min. (USA) / 15 min.
Installation Instructions
In addition, the detector periodically sends supervision signal as a serviceability report.
With PowerArt high level, sensitivity can be extended.
The detector has 3 modes: A . “Sleep” - for the detector transport or
long term storage, without causing an alarm. In this mode the current consumption is very low.
B . “Installation” - for sensor's spring active
range adjustment and for teaching the SpiderAlert / PowerArt system the detector’s identity.
C . “Operation”.
All mode changes and alarms are aurally indicated by an integral buzzer.
The SPD-1000 has tracking mode (for SpiderAlert only) that enables to track the secured object's location up to 10 minutes after its removal (with SpiderAlert receivers deployed within the site). This option is possible if the detector is attached to the secured object.
For a large painting, several SPD-1000 units can be used.
Battery Supervision: Automatic transmission of battery condition data as part of any status report.
Tracking Transmission: Every 30 sec., while the secured object is being moved from its original place, up to 10 min. after last movement.
Operating Temperatures: 0°C to 50°C (32°F to 122°F) Dimensions (HxWxD): 96 Weight (with battery): 34.8 g (1.2 oz) Color: Housing - white, spring - nickel Compliance with Standards: FCC part 15, IC:1467102181.
The term "IC" before the certification/registration number only signifies that the Industry Canada technical specifications were met.
x 28 x 22 mm
(3-13/16 x 1-1/8 x 7/8 in.)
Figure 2
External View
3333. INSTALLATION
. INSTALLATION
. INSTALLATION. INSTALLATION
3.1 Installation Options
Figure 3 - Installation Possibilities
DE3652 1
Figure 4 - Using a Bracket to Attach the Detector
Attention!
Before detector installation: 1 . Remove spring movement prevention sticker (see fig. 5). 2 . Remove protective non-metallic spacer that keeps the
spring in the “sleep” mode (shown in par. 3.7).
3.2 Setting the SMD Switches
Figure 5
Switch Setting Method
Table 1 - SMD Switches Functions
Switch Function Pos. Selected Option Default
SW. 1 Sensitivity
& tracking
ON Spider: Tracking enabled
PowerArt: High sensitivity ON
OFF Spider: Tracking disabled
PowerArt: Low Sensitivity
SW. 2 Buzzer ON Enabled ON
OFF Disabled
SW. 3 Supervision ON USA (60 Min.) ON
OFF Europe (15 Min.)
SW. 4 Mode ON SpiderAlert ON
OFF PowerArt or MCR-308
3.3 Preparation for Use
B . Verify that the teaching is successful, according to the
previously mentioned documents.
3.5 Teaching the SpiderAlert System
Teach SpiderAlert system to identify SPD-1000 transmissions:
A . In SpiderAlert software Click File/Transmitters/Museum/Add. B . Initiate low severity alarm transmission by momentarily
pressing Reset switch (see par. 3.3, step 1).
C . The detector’s ID number will be displayed in the yellow box. D . Press the “<<” button to move the ID number from the yellow
(temporary) box to the “ID” box.
E . In the Location box, type the secured object's name (i.e.
Mona Liza picture).
F . In Holder Group box, type a desired name for the museum
detectors group for whom the event handling will be identical.
G . Press the button, to display the Museum Group screen. H . Select the appropriate museum detectors group.
...
I . Press Edit button, define (for the operator) the handling
description for every detector’s event and press OK.
3.6 Operation
SPD-1000 function is based on magnetic field changes as a result of the secured object movements. The detector has 2 detection levels - low severity alarm (continuous slight touch) and high severity alarm (strong touch or removal).
Once stabilized, the detector checks its position continuously. Upon a movement detection, the detector sends alarm as follows:
Note: After HIGH alarm only, the detector needs 90-second stabilization period at least, for the next movement detection.
When Low or High level alarm is transmitted, 2 weak buzzer sounds are heard, as shown.
3.7 Entering the “Sleep” Mode
Entering Sleep mode (for description, see section 1) is as follows:
3.4 Teaching PowerArt / MCR-308
Teach PowerArt / MCR-308 to identify SPD-1000: A . Teach PowerArt (see par. 3.2G in PowerArt Prog. Guide) or
MCR-308 (see par. 3.5 in MCR-308 installation instructions). When instructed to transmit, initiate SPD-1000 low severity alarm transmission by momentarily pressing the Reset switch (see illustration 1 in par. 3.3).
Note: According to this signal, the PowerArt automatically learns
to identify high severity alarm, low severity alarm, low battery and supervision messages. According to this signal the MCR-308 learns to identify low severity alarm only.
To teach the MCR-308 the high severity alarm, create the alarm
after the detector has been stabilized, by strong movement / removal of the secured object.
VISONETIX LTD. (ISRAEL): VISONIC SYSTEMS INC. (U.S.A.): VISONIC LTD. (UK):
VISONETIX LTD. 2001 SPD-1000 DE3652- (REV. 5, 12/2001) Separate warranty statement is enclosed. www.visonetix.com
P.O.B 22020 TEL-AVIV 61220 ISRAEL. PHONE: (972-3) 645-6890, FAX: (972-3) 645-6891
10 NORTHWOOD DRIVE, BLOOMFIELD CT. 06002-1911. PHONE: (860) 242-9945, (800) 874-3989 FAX: (860) 242-0191
UNIT 1, STRATTON PARK, DUNTON LANE, BIGGLESWADE, BEDS. SG18 8QS. PHONE: (01767) 600857 FAX: (01767) 601098
2 DE3652
Compliance with Standards
This device complies with FCC Rules Part 15. Operation is subject to two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference that may be received or that may cause undesired operation. The user is cautioned that changes or modifications to the unit, not expressly approved by Visonic Ltd., could void the user's FCC or other authority to operate the equipment The 315 MHz is for USA & Canada - not allowed in any EU member state. The
433.92 MHz has no restriction in any EU member state.
Loading...