Visonic RP610PG2 User Manual

RP-610 PG2
Wireless Repeater for PowerG Communications
1. INTRODUCTION
2. SPECIFICATIONS
Frequency Band (MHz): Europe: 433, 868, USA: 915 Modulation: GFSK Antenna: Built-in antenna Communication Protocol: PowerG Power Supply: AC Power Supply: AC to AC adaptor:
120 VAC, 60 Hz / 9 VAC, 0.35 A min. (in the U.S.A.) 230 VAC, 50 Hz / 9 VAC, 0.35 A min.
Backup Battery Time to charge: 80 % ( 12 Hrs) Low voltage alarm: 4.8V Caution!
Risk of explosion if battery is replaced by an incorrect type. Dispose of used battery according to manufacturer's instructions.
Nominal Current Drain:
Frequency (MHz) 433 868 915
Battery Backup Duration (with fully charged 1300 mA/h battery): 48 hours.
Type A
:
4.8-Volt 1300 mAh NiMH rechargeable.
100 mA 100 mA 100 mA
LED indicator: Operating Temperature: Humidity:
condensing. For 30 days per year relative humidity may vary between 85 % and 95 % non-condensing.
Dimensions: 161x161x50mm (6-7/16 x 6-7/16 x 1-3/4 in) Weight: 470g (16.5 oz.) Compliance with Standards: Europe: EN 50131-1 Grade 2, Class II, EN 501 30-5, EN 50131-
6, EN 301489, EN 50130-4, EN 300 220
USA: Canada:
WARNING!
requirements, the repeater should be located in a distance of at least 20 cm from all persons during normal operation. The antennas used for this product must not be co-located or operated in conjunction with any other antenna or transmitter.
3. INSTALLATION
Mount the repeater as high as possible above the floor and
3.1 Repeater's Location Selection
A. In a repeater setup, install the repeater where good
communication is assured with the target receiver and with the transmitters deployed in the repeat er's cover age area .
B.
well away from metal chimneys, large metal cabinets, metal doors and reinforced concrete walls, all of which may reduce the communication range.
Make sure that the location you have selected is near an
C.
electrical outlet.
Installation Instructions
Figure 1.
Green LED lights when AC power on.
Average relative humidity of approximate 75% non-
(FCC) CFR47 Part 15
RSS210
To comply with FCC RF exposure compliance
External View
0°C to 49°C (32°F to 120°F).
D-302415 1
2
(*)
A
A
1
3
C
5
A. Mounting surface. B. For back tamper screw.
AC to AC adaptor.
C. Attention! For Europe, the transformer has to be CE compliant and power limited.
Figure 2: Installation
4. ENROLLMENT
Refer to the PowerMaster-10 Installer Guide for the device enrollment procedure.
5. CONFIGURATION AND OPERATION
5.1 Service Messages
Five kinds of event codes are automatically included in a service transmission in addition to the repeater’s:
AC fail  Low Battery  End of life  Tamper Upon power failure, recharging stops and the backup battery takes over. It is therefore correct to assume that without power input the battery is gradually weakening and may be reported as “low”.
Power / battery restore is reported only in the following test report. End of life is reported whe n bat tery power is depleted and de vice is
about to shut down.
Supervision
.
6. MAINTENANCE
Note:
Battery replacement should be done by a service man.
Tamper restore is reported immed iate ly upon occu rrence . If the tamper or power failure condition persists long enough, respective alerts will be sent out again with each test report.
A
B C
D
Siren.
A.
Motion detector.
B.
Door or window open/close detector
C.
Keyfob
D.
RP-610 PG2 Repeater
E.
PowerMaster-10 Control Panel
F.
4
B
A
6
E
Figure 3: Repeater Configuration
F
2 D-302415