Comcast MCT-350
Fig. 3a – Attaching the Adhesive Tape
Door / Window Sensor
1. INTRODUCTION
The MCT-350 is a fully supervised, wireless magnetic door / window
sensor, for use with ZigBee enabled home security panels. The sensor
includes a built-in reed switch (that opens upon removal of a magnet
placed near it).
The MCT-350 tamper switch is activated when t he cover is removed.
A periodic supervision message is transmitted automatically. The target
receiver is thus informed, at regular intervals, of the unit’s active
partic ipation in the system.
Operating power is obtained from an on-board 3 V Lithium batter y. W hen
the battery voltage is low, a “low battery” message will be sent to the
receiver 60 days before expiration of battery life (for operation in room
temperature).
2. SPECIFICATIONS
WIRELESS
Supported Network: ZigBee H.A 1.2
Frequency: 2.4 GHz as per IEEE 802.15.4
Tamper Alert: Reported when a tamper event occurs and in any
subsequent message, until the tamper switch is restored.
ELECTRICAL
Internal Battery: 3V Lithium battery, typ e CR2450. Use Varta only.
Nominal Battery Capacity: 620 mAh
Battery Life Expectancy: 5 years (for typical use).
3. ACTIVATING AND PAIRING THE SENSOR
To pair the sensor to the security panel, y ou must set it to pairing mode.
1. First set the panel to pairing mode and then the sensor.
2. To activate, pull t he activation strip (from either side) that protrudes
from the back of the sensor.
3. The LED blinks 3 time s e very 5 seconds (repeated for up to 20 times) to
indicate that the sensor is searching for a security panel.
Note: If sensor pairing is not successful during the searching process by tripping the door / window sensor or by pressing the tamper switch the searching process will restart.
4. Complete the pairing procedure on the security panel (see the pairing
instructions in the security panel’s installation guide).
Note: Pairing should be performed before installation.
4. INSTALLATION AND SENSOR TESTING
CAUTION: This equipment shall be installed by Service Personnel in
non-hazardous indoor locations only.
4.1 Mounting
NOTE: It is highly recommended to attach the door / window sensor to the
top of the door/window on the fixed frame and the magnet to the movable
part (door or window). Make sure that the magnet is located not more than 6
mm (0.25 in.) from the sensor’s marked side .
The sensor should be mounted on the fixed surface and the ma gnet on
the moving surface (see Figure 3b).
1. Peel away the
release liners
from the two strips
of double-sided
adhesive tape and
attach to the
device a nd
magnet.
Installation Instr uctions
Figure 1 –
Externa l View
Note: Inability to connect with wireless network, or wireless link quality no
higher than 20% may significantly reduce the exp ec ted batte ry life.
Battery Power Test: Performed immediately upon battery insertion and
periodically every several hours.
Battery Supervision: Automatic transmission of battery co n d i ti on data as
part of any status report.
ENVIRONMENTAL
Operating Temperature: 0°C to 50°C (32°F to 122°F)
Humidity: 93% RH, non-condensing
Dimensions: 66 x 25 x 10 mm (2-9/16 x 1 x 6/16 in.)
Weight (including battery): 15g (0.5 oz)
Fig. 3b – Mounting on Fixed Surface
Figure 2 – Activation Strip
A. Double-sided
B. Magnetic location
Note: Silicone can also be
used to securely mount
the magnet according
to the location marks
and fasten the device
and magnet to the
mounting surface. The
sensor should be
mounted on the fixed
surface and magnet
on the moving surface.
adhesive tape
marks
4.2 Sensor Testing
Close the door or window, thus restoring it to the undisturbed state
5. BATTERY REPLACEMENT
Fig. 4a – Opening Battery Cover
MCT-350 Installation Instructions 1
1. Press down on the battery cover and slide in the direction shown in
Figure 4a to open.
2.
Push against the clip and lift the battery from the slot below it.
3. Insert t he new battery into the sensor while observing battery polarity
(see Fig ure 4b).
4. Close the battery cover.
Note: The required battery is CR2450 Lithium 3V, manufactured by VARTA.
Fig. 4b –Replacing Battery
Caution! Risk of explosion if battery is replaced by an incorrect type.
Dispose of used battery according to the manufacturer's instructions.
6. REBOOTING THE SENSOR
and is set to pairing mode (see section 4).
If necessary, replace the sensor’s battery.
Consult with your installer or system
lowers the overall security level of your system.
Figure 5 - Range Coverage Directions
W.E.E.E. Product Recycling Declaration
VISONIC LTD. 2015 MCT-350 (Rev 1, 9/15) Please refer to the separate Warranty statement
You can reboot the sensor, as follows:
1. Remove the battery cover.
7. DEFAULTING THE SENSOR
CAUTION! The defaulting process removes the device from the network
and enables re-pairing.
Open the battery cover and pull back the clip to remove the battery (see
Figure 4).
8. TROUBLESHOOTING
If you encounter one of the following problems with the MCT-350, perform
the suggested remedy:
Attempt to pair the sensor
is unsucce ssful.
Make sure that the sensor has been defaulted
Make sure the security panel supports the
The sensor and the panel
do not communicate.
Perform the signal strength testing procedure
described in the security panel installation
manual. Make sure that th e si gnal is sufficient.
9. COMPLIANCE WITH STANDARDS
USA/CANADA
FCC USA: CFR 47 part 15, Canada: RSS 247.
This device complies with Part 15 of the FCC Rules and RSS-247 of Industry and
Science Canada. Operation is subject to the following two conditions: (1) This device
may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
This device complies with Indus try Ca n ada lic en se-exempt RSS standard(s). Operation is
subject to the following two conditions: (1) this device may not cause interference, and (2)
this device must accept any interference, including interference that may cause undesired
operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux
appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions
suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de
l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d'en compromettre le fonctionnement.
FC
C ID: WP3MCT350SMA5
IC: 1467C-MCT350SMA
Reed Switch Positions
Note: Dimensions in the following table ar e t ypical.
2. Press and release the tamper switch for 1 to 2 sec. (see Figure 4b).
3. Close the battery cover.
1. Press and hold down the sensor’s tamper switch (see Figure 4b).
2. Insert the battery into the sensor while observing battery polarity (see
Figure 4b).
3. Release the tamper switch within 4 seconds (the L ED blinks 3 times
every 5 seconds).
4. To re-pair the sensor, follow the instructions in section 3.
The sensor sends a Low
Battery indication.
Panel does not arm
because of an
unrecognized sensor
malfunction
USA/CANADA
Complies with:
ANSI/UL 634, ULC – C634
FCC Compliance Statement
This device has been tested and found to comply with the limits for a Cl ass B digital
device, pursuant to Part 15 of the FCC Rules. T hese limits are designed to provide
reasonable protection against harmful interference in residential installations. This
equipment generates uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful
interference to radio and television reception.
However, there is no guarantee that interference will not occur in a particular
installation. If this device does cause such interference, which can be verifi ed by
turning the device off and on, the user is encouraged to eli minate the interference by
one or more of the following measures:
– Re-orient or re-locate the receiving antenna.
– Increase the distance between the device and the receiver.
– Connect the device to an outlet on a ci rcuit different from the one that supplies
– Consult the dealer or an experienced radio/TV technician.
WARNING! Changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user’s authority to operate the equipment.
power to the receiver.
To ensure continuous proper operation, replace
the battery within two weeks of the first Low
provider before you disable a zone.
Disable the detector zone (see the security panel
user manual). Note that disabling a sensor zone
10. PRODUCT LIMITATIONS
Visonic Ltd. wireless systems are very reliable and are tested to high
standards. However, due to low transmitting power and limited range
(required by FCC and other regulatory authorities), there are some
limitations to be considered:
A. Receivers may be blocked by radio signals occurring on or near their
operating frequencies, regardless of the digital code used.
For information regarding the recycling of this product you must contact the company from which you orignially purchased it. If you are discarding this product and not returning it for
repair then you must ensure that it is returned as identified by your supplier. This product is not to be thrown away with everyday waste.
Directive 2002/96/EC Waste Electrical and Electronic Equipment.
EMAIL: info@visonic.com
INTERNET: www.visonic.com
2 MCT-
B. A receiver responds only to one transmitted signal at a time.
C. Wireless devices should be tested regularly to determine whether
there are sources of interference and to protect against faults.
The user is cautioned tha t changes or modifications to the unit, not
expressly approved by Visonic Ltd., could void the user’s FCC or
other authority to operate the equipment.
350 Installation Instructions