1. INTRODUCTION
A periodic supervision message is transmitted automatically. The target receiver is thus informed, at regular intervals, of the unit’s active participation in the system.
Operating power is obtained from an on-board 3 V Lithium battery. When the battery voltage is low, a “low battery” message is sent to the receiver.
2. SPECIFICATIONS
WIRELESS
Frequency: Frequency: 2.4 GHz as per IEEE 802.15.4 Tamper Alert: Reported when a tamper event occurs and in any
subsequent message, until the tamper switch is restored.
Supervision Message: Signaling at 24-minute intervals.
ELECTRICAL
Internal Battery: 3V Lithium battery, type CR2. Use Panasonic, GP or
Sanyo only.
Battery Life Expectancy: 3-5 years (for typical use). Battery Power Test: Performed immediately upon battery insertion and periodically every several hours.
Battery Supervision: Automatic transmission of battery condition data as
part of any status report.
Installation Instructions
MCT-320 SMA
ENVIRONMENTAL
Operating Temperature: -10C to 55C (14F to 131F). Dimensions: 51 x 30 x 21 mm (2 x 1-3/16 x 13/16 in.) Weight (including battery): 36g (1.27 oz)
COMPLIANCE WITH STANDARDS
Designed to comply with UL 639, ULC-S306, Title 47 CFR Part 15, IC RSS-210
This device complies with Part 15 of the FCC Rules and RSS-210 of Industry and Science Canada. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Transmitter & magnet
location marks
Fig. 1 – MCT-320 SMA
3. PAIRING/DEFAULTING THE SENSOR
To pair the sensor to the control panel, you must set it to pairing mode.
1. Press and hold down the sensor’s tamper switch.
2. Insert the battery into the sensor.
3. Release the tamper switch and press it again within 4 seconds.
4. Complete the pairing procedure on the control panel (see the pairing
Fixed
frame
Moving
part
instructions in the control panel’s installation guide).
D-303359 MCT-320 SMA Installation Instructions 1
.
4. MOUNTING
NOTE: It is highly recommended to attach the transmitter to the top of the door/window on the fixed frame and the magnet to the movable part (door or window). Make sure that the magnet is located not more than 6 mm (0.25 in.) from the transmitter’s marked side. The transmitter should be mounted on the fixed surface and the magnet on the moving surface (see Figure 1).
Magnet Mounting
Magnet
3 mm
1
Remove
spacer
Magnet Mounting with Optional Spacer(s)
Optional spacer(s), 3 mm width, 7mm with, or both, can be used for the magnet mounting.
spacer
r
e
c
a
p
s
mm
3
A. Fasten the spacer to mounting
surface with 2 serews.
B. Locate the magnet on the spacer at
the correct direction and push it upwards
Fig. 2 – Magnet Mounting
2
Join the
1
2 spacers
Sensor Mounting
er
c
a
p
s
m
7m
er
ac
p
s
m
3m
Magnet with
3mm spacer
Fig. 3 – Magnet Spacers
1
Push screwdriver #2 on the “stair” and turn the screwdriver clockwise to separate the transmitter from its bracket
Magnet with
7mm spacer
Fasten the br acket with 3 screws
2
Fasten
3 & 7mm
spacers
mounting
Magnet with
3 & 7mm
spacers
2
Locate and push the
3
transmitter on the bracket
Fig. 4 – Transmitter Mounting
2 D-303359 MCT-320 SMA Installation Instructions
5. TESTING THE SENSOR
Close the door or window, thus restoring it to the undisturbed state.
6. TROUBLESHOOTING
If you encounter one of the following problems with the MCT-320 SMA, perform the suggested remedy:
Problem Remedy
Attempt to pair the sensor is unsuccessful.
The sensor and the panel do not communicate.
7. PRODUCT LIMITATIONS
Visonic Ltd. wireless systems are very reliable and are tested to high standards. However, due to low transmitting power and limited range (required by FCC and other regulatory authorities), there are some limitations to be considered: A. Receivers may be blocked by radio signals occurring on or near their
operating frequencies, regardless of the digital code used.
W.E.E.E. Product Recycling Declaration For information regarding the recycling of this product you must contact the company from which you orignially purchased it. If you are discarding this product and not returning it for repair then you must ensure that it is returned as identified by your supplier. This product is not to be thrown away with everyday waste. Directive 2002/96/EC Waste Electrical and Electronic Equipment.
Make sure that the sensor has been defaulted and is set to pairing mode (see section 3).
Perform the signal strength testing procedure described in the control panel installation manual. Make sure that the signal is sufficient. If necessary, replace the sensor’s battery.
Problem Remedy
The sensor sends a Low Battery indication.
Panel does not arm because of an unrecognized sensor malfunction
To ensure continuous proper operation, replace the battery within two weeks of the first Low Battery indication.
Consult with your installer or system provider before you disable a zone.
Disable the detector zone (see the control panel user manual). Note that disabling a sensor zone lowers the overall security level of your system.
B. A receiver responds only to one transmitted signal at a time. C. Wireless devices should be tested regularly to determine whether
there are sources of interference and to protect against faults.
The user is cautioned that changes or modifications to the unit, not expressly approved by Visonic Ltd., could void the user’s FCC or other authority to operate the equipment.
VISONIC LTD. (ISRAEL): P.O.B 22020 TEL-AVIV 61220 ISRAEL. PHONE: (972-3) 645-6789, FAX: (972-3) 645-6788 VISONIC INC. (U.S.A.): 65 WEST DUDLEY TOWN ROAD, BLOOMFIELD CT. 06002-1376. PHONE: (860) 243-0833, (800) 223-0020. FAX: (860) 242-8094 VISONIC LTD. (UK): UNIT 6 MADINGLEY COURT CHIPPENHAM DRIVE KINGSTON MILTON KEYNES MK10 0BZ. TEL: (0870) 7300800 FAX: (0870) 7300801 PRODUCT SUPPORT: (0870) 7300830 VISONIC GmbH (D-A-CH): KIRCHFELDSTR. 118, D-40215 DÜSSELDORF, TEL.: +49 (0)211 600696-0, FAX: +49 (0)211 600696-19 VISONIC IBERICA: ISLA DE PALMA, 32 NAVE 7, POLÍGONO INDUSTRIAL NORTE, 28700 SAN SEBASTIÁN DE LOS REYES, (MADRID), ESPAÑA. TEL (34) 91659-3120,
FAX (34) 91663-8468. www.visonic-iberica.es INTERNET: www.visonic.com
VISONIC LTD. 2011 MCT-320 SMA D-303359 (Rev 0, 07/11)
D-303359 MCT-320 SMA Installation Instructions 3
Loading...