PowerG Wireless Magnetic Contact Device with
Hardwired Inputs.
Introduction
The device is a supervised, 2-way wireless PowerG magnetic contact
device withthefollowingfeatures:
l Built-in reedswitch
l Auto-enrollment process whenpulling the tab
l Two separateauxiliary hard-wired inputs support normally
closed( NC), normally open(NO), end of line (EOL), double end
of line(DEOL), and triple end of line ( TEOL). Both external and
internal inputs can be usedat the same time. These hard-wired
inputs can be programmed for use with other hard-wired sensors
(use only UL/ULC burglary listed sensors)
ing support are based on panel supporting version.
The reed switch andauxiliary inputs behave as separatetransmitters,
although they trigger thesame RF transmitter. Removing thecover
activates the tamper switch. If configured, LED lights only whenreporting alarm or tamper events. Built-in link quality indicators r educe
installation time by eliminatingthe needfor the installer to physically
approachthe control panel. Smart temperature-sensingcapabilities
issue an alert whentheambient temperature reaches a predetermined
threshold.
For detailed instructions, see theD-307631InstallationInstructions at
http://www.visonic.com/download-center. Alternatively, contact
info@visonic.com to request the completeversion of the MC-309 PG2
InstallationGuide.
Mounting the device
It is highly recommended to attachthetransmitter to the top of the
door/window on the fixed frame andthemagnet to thedoor or window.
Ensure the m agnet is locatedno more than 6 mm (0.25in.) from the
transmitter’s markedside.
Note: Once the cover is removed,a tamper message is transmitted
to the receiver. Subsequent removal of the battery prevents transmission of tamper restore, leaving the receiver in permanentalert. To
avoid this, press thetamper switch while removing the battery.
Attention!The unit has anoptional back tamper switch under the
PCB. As longas the PCB is seatedfirmly within the base, theswitch
lever presses againsta special break-away base segment that is
loosely connected to thebase. Be sure to fasten the break-away segment to the wall. If the detector unit is forcibly removedfrom thewall,
this segmentbreaks away from the base,causing the tamper switch
to open.
Note:
l For UL Commercial Burglary installations, theuse of the back
tamper is mandatory.
l Do not use adhesivetape for the EU Market.
Mounting with screws
1. With the cover removed, flex the retainer and remove the PCB.
2. Mark and drill two holes in the mounting surface.
3. Align the device with the magnet according to the locationmarks
and fastenthedeviceand m agnet to the mountingsurface.
4. Fastenthebase with 2 countersunk scr ews.
5. Mount themagnet base with the 2 suppliedscrews.
6. Attachthe magnet to the magnet base.
Note:For UL Commercial Burglary installations, the use of the back
tamper is mandatory.
Mounting with adhesive tape
1. Peel away the release liners from the two strips of double-sided
adhesivetape and attachto thedeviceandmagnet.
2. Align the device with the magnet according to the locationmarks
and fastenthedeviceand m agnet to the mountingsurface.
Enrolling the device
1. Enter the installer menuand select 02: ZONES / DEVICES.
2. Select ADD NEW DEVICES.
3. Remove the pull tabto start theauto-enrollment process.
Note:If the panel does not support ID: 110-XXXX, it enrolls as W
/ D Contact with the ID: 101-XXXX.
Alternatively, press theenrollment button, restore the tamper, or enter
thenumber of the deviceprintedon the label (ID: 110-XXXX).
Inserting or replacing the battery
To insert the battery, complete the following steps:
1. Insert a flat-edged screwdriver into the slot and push upward to
remove cover.
2. Remove the screw and separate the cover from thebase.
3. Observe polarity and remove the pull tab.
4. Connect the sensor wire to the terminal block.
To replace the battery, completethe following steps:
1. Remove the cover
2. Wedgea flat head screwdriver under the battery
3. Twist the screwdriver usingthebase as a lever to remove the
battery.
Note:
l When manually programming wireless devices, if a devicehas
been poweredup for more than48 hours it cannot be enrolled
into thesystem until the device has been tamperedand r estored.
When programming the panel using the Quick Enroll procedure,
follow the steps detailed in Enroll the Device intotheSystem.
l After restoring a low battery, the system may take up to 5
minutes to clear the trouble.
Caution:Risk of explosionif thebattery is replaced by an incorrect
type. Disposeof used batteries accordingto the manufacturer's
instructions.
WARNING!This product contains a coin battery. If it is swallowed, it
cancausesevere internal bums in just two hours and can lead to
death. Keep new andused batteries away from children. If thebattery
compartment does notclose securely, stop using the product to keepit
away from children. If you think batteries m ight havebeen swallowed
or placed inside any part of the body, seek immediate medical attention.
Low battery detection
Note:For UL installations, the detector is for use with UL Listed con-
trol units only.
The device includes low-battery condition detection. When this conditioni s detected, a trouble message transmits to thecompatible
receiver/control panel. This provides visual identification of the unit
that r equires a battery change. For UL commercial burglary installations, replace the battery yearly.
Note:After restoring a low battery, the system may take up to five
minutes to clear the trouble.
Temperature display
Refer to thePowerMaster Installation Manual for the temperature display procedure.
Note:This is basedon thesupportingpanel version.
Placement testing / local diagnostic test
Before permanently mountingany wireless device, temporarily m ount
thedevice and perform a placement test by completing thefollowing
steps:
1. Separatethebase of the devicefrom the cover.
2. Press thetamper switch once and release it.
3. Put the cover on thedeviceto return the tamper switch to its normal (undisturbed) position. Then secure the front cover to the
base with the case closure screw.
4. Openthe door or window andverify thered LED blinks, indicatingdetection.
5. After two seconds, the LED blinks three times.
Table1 indicates received signal strength:
LEDresponseReception
Three green LEDblink sStrong
Three orange LED blink sGood
Three red LEDblinksPoor
No blinksNo c ommunication
Important!Only GOOD or STRONG signal strengths are acceptable.
If you r eceivea POOR signal from the device, re-locate andr e-test
thedevice until a GOOD or STRONG signal is received.
Note:
l For UL/ULC installations,only STRONG signal levels are
acceptable. After installation, verify the productfunctionality in
conjunction with the compatiblereceivers of thePowerMaster
Control Panel.
l For detailed placement instructions, refer to thecontrol panel
Reference Guide.
Table 1:Signal strength
Wiring the auxiliary input
1. Connect the auxiliary sensor contacts across the auxiliary input
terminals.
2. If theauxiliary input is definedas NC type,series connectedNC
sensor contacts must be used exclusively. An EOL r esistor will
not be required.
3. If theauxiliary input is definedas a NO type,parallel connected
NO sensor contacts must be used exclusively. An EOL resistor
will notbe required.
4. For EOL supervision, NC sensor contacts can be used. A 5.6 kΩ
EOLresistor must be wired at the far endof thezoneloop.
Note:
l For UL installations,thedeviceconnected to the initiating cir cuit
must be located in thesame room as thetransmitter.
l For UL/ULC installations,connectonly UL/ULC listed devices to
theauxiliary wiring input.
l An alarm messageis transmittedonce the loop is opened or
short circuited.
Configuration
Table3 shows theavailable programmableoptions:
Alarm LED
Default - [Y]
Reed Switch Default [Y]
External Inputs
- Default[Y]
Supervision -
Default [Y]
Temperature
Sensor Default
Enables the devi ces LED to activate when an alarm
event occurs.
Note:Disable LED to achieve higher battery li fe time
for commercial use.
Enables or disabl es the reed s witch.
Enables or disabl es the external input.
Enables supervision of the devi ce.
Enables or disabl es the temperature sensor.
Note:Based on panel supporting version.
Table 2:Programmable options
Selections
Configures auxi liary inputs as one fo the following options:
[00] Disabled[01] EOL/DEOL/TEOL [02] Normally Open
[03] Normally Closed
Note:DEOL and TEOLare based on panel supporting version.
Zone EO L/DEOL/TEOL- Default [01]
Table 3:Selections
Range coverage directions
Non-metallic surfaceSupportsMetallic surface
OpenCloseDirectionOpenClose
21 mm19 mmX16 mm15 mm
27 mm24 mmY12 mm10 mm
13 mm12 mmZ12 mm10 mm
Note:
Values s tated above may vary by up to 10%. For UL instal lations, the
gaps cannot be greater than the above measurements. For s teel installations, the gaps cannot be l ess that 3.175 mm.
Table 4:Range coverage directions
Specifications
Frequency Band: NA amd LATAM: 915 M Hz; Europe and rest of
world: 433MHz, 868 MHz
Frequency Bands Maximum Power:
868.0MHz - 868.6 MHz 12 dBm (15 mW )
868.7MHz - 869.2 MHz 12 dBm (15 mW )
433.22 M Hz - 434.64MHz 6dBm (4 mW)
Communication Protocol: PowerG
Alarm Input: One internal, two external
Supervision: Signalingat four minute intervals
Tamper Alert: Reported when a tamper eventoccurs
Battery type: 3 V Lithium CR- 123A type battery GP
Battery Life Expectancy: 8 years with typical use / 5 years with typ-
ical commercial use (LED disabled)
Battery Supervision: Automatic transmissionof battery condition
data as part of periodic status report andimmediately uponlow battery
conditiondetection
Temperature range: -10 ºC to +55 ºC (14 °F to 131 °F). UL/ULC
only verified the range 0 ºC to 49 ºC (32 ° F to 120 °F)
Relative Humidity: Up to a maximum 93 % RH, non-condensing
Dimensions ( LxWxD): 81 mm x 34 mm x 25 mm (3.2 in. x 1.3 in. x
1.0i n.)
Weight (including battery): 53g (1.9oz)
Auxiliary Input Cable Length: 10 m m ax, AWG22
Auxiliary Input EOL Resistor: 5.6 KΩ
Installed by service persons andfor use in indoor non-hazardous locations only.
Low Battery trouble level: 2.5 V
Compliance with standards
The MC-309 PG2 c omplies with the following s tandards:
Europe: EN 300220, EN 301489, EN 50130-4, EN 61000-6-3,
EN 62368-1, EN 50131-1, EN 50131-2-6 Grade 2, Clas s II and
EN 50131-6 Type C.
Hereby, Vi sonic Ltd. declares that the radio equipment type
MC-309 PG2 is in c ompliance with Directive 2014/53/EU.
The full text of the EUdeclaration of conformity i s available at
the fol lowing internet address:
http://www.visonic.com/download-center
USA:FCC-CFR47 Part 15, UL-UL634
Canada: IC-RSS-247, ULC - C634
Security Grade: Designed according to EN 50131-1, EN
50131-2-6, and EN 50131-6 Type C:this equipment c an be
applied in i nstall ed sys tems up to and including Security
Grade 2.
Environmental Class: EN-50131-2-6 Class II
Note: This equipment has beentestedandfoundto comply with the
limits for a Class B digital device,pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interferencein a residential installation. This equipment generates, uses and can radiate radiofrequency energy and, if
not installedand used in accordancewith the instructions, may cause
harmful interference to r adio communications. However, there is no
guarantee thatinterferencewill not occur in a particular installation. If
this equipment does causeharmful interference to radioor television
reception,which can be determined by turning the equipment off and
on, theuser is encouragedto try to correct the interference by oneor
more of the following measures:
– Reorient or relocatethereceivingantenna.
– Increasetheseparationbetween the equipment andreceiver.
– Connect theequipment intoan outlet ona circuit different from thatto
which the receiver is connected.
– Consult the dealer or an experienced radio/TVtechnician for help.
Cet équipment a ététestéet jugéconforme aux limites s' appliquant à
unappareil numériquede classe B, conformément à la Partie 15 des
réglementations de la FCC. Ces limites ont été élaborées pour offrir
une protectionraisonnable contre les interferences nuisibles dans une
installation résidentille.
This class B digital apparatus complies w ith CanadianICES-003.
Cet appareil numerique de la classe B est conforme a la norme NMB003 du Canada.
WARNING! Changes or modifications to this unit not expressly
approvedby the party r esponsiblefor compliance could void the
user' s authority to operate the equipment.
This device complies with Part 15of the FCC Rules and RSS-247of
ISED. Operation is subject to the following two conditions: (1) This
device may notcauseharmful interference, and ( 2) this device must
accept any interferencereceived, includinginterferencethat may
cause undesired operation.
Leprésent appareil est conforme aux CNR d’ISED applicables aux
appareils radioexempts de licence.L’exploitation est autorisée aux
deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectriquesubi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
To comply wi th FCC andIC RF exposure compliance requirements,
thedevice should be locatedat a distance of at l east 20 cm from all
persons during normal operation. The antennas used for this product
must not be co-l ocated or operatedin conjunction with any other
antenna or transmitter.
Le dispositif doit être placé à une distance d'au m oins 20 cm à partir
de toutes les personnes au cours de son fonctionnement normal. Les
antennes utilisées pour ce produit ne doivent pas être situés ou
exploités conjointementavec une autre antenne ou transmetteur.
W.E.E.E. Product Recycling Declaration
Forinformation regarding the recycling of this product y ou must
contact the company from which you originally purchased it. If
you are di scarding this product and not returning i t for repair
then y ou must ensure that it is returned as identified by y our
supplier. This product is not to be thrown away with everyday
waste.
European Directive 2002/96/EC Waste El ectrical and Electronic Equipment.
Warranty
Visonic L imited( the“ Manufacturer") warrants this produc tonly (the "Produc t") tothe original purchaser only (the “P urchas er”) ag ainstdefective work manship and materialsunde r normal use of the
Produc tfor a per iod oftwelve (12) monthsfrom thedate of shipmentby the Manufacturer.This Warr anty
is absolutely conditionalupo n theP roduct having bee n properly ins talled,maintained and operated
under conditions of normalus e in acc ordance w iththe Manufacturers recommended installation and
operationins tructions.Pr oducts which have bec omedefective for any other reas on,a ccor ding tothe
Manufacturers discr etion,such as improper installation,failure tofollow reco mmended installationand
operationalinstruc tions,neglect,willfuldamage,misus e or vanda lism,accidental damage,alterationor
tampering,or repair by anyone other than themanufacturer, are not cover ed by this Warr anty.
There is absolutely no war ranty on software,and alls oftwareprod ucts are s old as a use r license
under the termsof the software license agreement included withs uch P roduct.
There is absolutely no war ranty on software,and alls oftwareprod ucts are s old as a use r license
under the termsof the software license agreement included withs uch P roduct.
TheManufacturer does notre present thatthis Produ ctmay no tbe c ompromisedand/or c ircumvented
or thatthe Produc tw illprev entany death and/or personal injury and/orda mageto property r esulting
fromburglary ,r obbery, fireo r otherwise, or thatthe Produ ctw illin all cases prov ide adequatew arning
or protection.The Pr oduct,prop erly installeda nd maintained,only reduces ther isk of suc h events
withoutwarning and it is not a guarantee or insur ance thats uch even tsw illnot occur .
Conditionsto VoidWarranty: This warr anty applies only to defects inpa rts and work manship relating
tonormal use of the Produc ts.Itdoes notc over:
* damageinc urred in shipping or handling;
* damagec aused by disaster su ch as fire, flood,wind,earthquake or lightning;
* damagedue tocau ses bey ond the control ofthe Seller s uch as exces sive v oltage,mechanical
shock or water damage;
* damagec aused by unauthorized attachment,alterations,modifications or foreignobjec ts being used
withor in c onjunctionw iththe Produ cts;
* damagec aused by peripherals ( unless s uch per ipherals were supplied by the Seller;
* defectsc aused by failureto prov ide a suitableins tallationenv ironmentfor the products;
* damagec aused by use of theP roduc ts forpur poses otherthan those for which they w ere designed;
* damagefrom improper maintenance;
* damagear ising outof any other abus e,mishandling or improper app licationof theP roducts.
Items Not Covered byWarranty: Inaddition tothe itemswhich void the Warranty, thefollowingitems
shall notbe c overed by Warr anty:(i) freight cost tothe repair centre;( ii)c ustoms fees,taxes, or V AT
thatmay be due;( iii)P roduc ts which are not identified withthe S eller's produc tlabel and lot number or
serial number;( iv) P roducts disas sembled or repaired ins uch a manner as toa dvers ely affectper-
formanceor prevent adequate inspection or testing tov erify any warr anty claim.Ac cess cards or tags
returned for replacementunder warran tyw illbe c reditedor replaced at the Seller's option.
THISWA RRA NTY IS E XCLU SIVE AND E XP RES SLY IN LIEU OF ALL OTHER WARRA NTIES,
OBLIGATIONS OR LIABILITIES, WHE THER WRITTEN, ORAL, EX PRE SS OR IMPLIED,
INCLUDINGA NY WA RRA NTY OF MERCHA NTAB ILITY OR FITNESS FOR A P ARTICULAR
PURP OSE ,OR OTHER WISE. INN OC AS E S HALL THE MANUFACTUR ER B E LIAB LE TO
ANY ONE FOR A NY CONS EQUE NTIAL OR INCIDENTAL DA MAGES FOR BRE ACH OFTHIS
WARRA NTY OR A NY OTHER WAR RANTIES WHATSOE VE R,A S A FORES AID.
THE MANUFA CTURER S HA LL INN O EVE NT BE LIABLE FOR ANY SP EC IAL,INDIRECT,
INCIDENTAL,C ONSE QUENTIAL OR P UNITIVE DAMAGE S OR FOR LOSS ,D AMAGE, OR
EX PEN SE ,INCLUDING LOSS OFU SE ,P ROFITS, REV EN UE, OR GOODWILL,DIRECTLY OR
INDIRECTLY AR ISINGFROM PURCH AS ER’S USE OR INABILITY TOU SE THE PR ODUCT,OR
FORLOS S OR D ESTRU CTIONOF OTHER P ROPE RTY OR FROMA NY OTHER CA USE ,E VE N
IFMANUFAC TURER HA S B EE N A DVISE D OF THE P OSSIBILITY OFS UCH DA MAGE.
THE MANUFA CTURER S HA LL HAV E N OL IABILITYFOR A NY DE ATH, PE RSONA L AN D/OR
BODILY INJURY AN D/ORD AMAGE TO P ROPER TY OR OTHER LOS S WHE THER DIRECT,
INDIRECT,INCIDENTAL, CONS EQUEN TIALOR OTHERWISE, BA SE D ON A CLAIMTHA T THE
PRODUC TFA ILED TOFUNC TION.HOWEVE R, IFTHE MANU FACTURE R IS HELD LIABLE ,
WHETHE R DIRECTLY OR INDIRECTLY, FORA NY LOSS OR D AMAGE ARISING UNDE R THIS
LIMITED WARRA NTY, THE MAN UFACTURE R'S MAX IMUMLIABILITY( IFAN Y) S HALL NOTIN
ANY CAS E E XCE ED THE P URCHA SE PRICE OFTHE PRODUC TINV OLVED ,WHICH S HALL
BE FIXED AS LIQUIDATED DA MAGES AND N OTA S A PE NALTY ,A ND S HALL B E THE
COMPLETE A ND E XCLU SIVE REMEDY AGA INST THE MANUFA CTURER. SOME
JURISDICTIONS DO NOT ALLOW THE EX CLUSION OR LIMITATIONOF INCIDENTAL OR
CONSE QUENTIAL DA MAGES ,S O THESE LIMITATIONS MAY NOT AP PLY UND ER CE RTAIN
CIRCUMSTANCE S.
When accep tingthe delivery of the Produc t,theP urc haser agr ees to thes aid conditions ofs ale and
warranty and he recognizes having been informed of.
TheManufacturer sha llbe under no liability whatsoev er arising out of thec orruption and/or malfunctioningofany telecommunication or electronic equipmentor any prog rams.
TheManufacturers ob ligations under thisWar ranty are limitedsolely to repair and/or r eplace at theManufacturer’s discr etionany Produc tor partthereof thatmay prov e defective.A ny repair an d/orr eplacementshall note xtend theoriginal Warr anty period.The Manufacturer shall not be respons ible for
dismantling and/or reinstallationcos ts.To exerc ise this Warranty the Pr oduct mustbe r eturned tothe
Manufacturer freight pre-paid and ins ured.A ll freightand insuran ce cos ts are the respons ibility of the
Purc haser an d are not included in this Warranty.
This warranty s hallnot be modified,varied or ex tended,and the Manufacturerd oes not authorize any
person to act on its behalfin the modification,var iationor ex tension ofthis warr anty.This war ranty shall
apply tothe P roduct only. All produc ts,acc esso ries or attachmentsof others us ed in conjunction with
theP roduct,inc ludingba tteries, shall be cov ered s olely by their own war ranty,if any. TheManufacturer
shall notbe liable for any damage or loss whatsoev er,w hether directly,indirec tly,incidentally,consequentiallyo r otherwise, caused by the malfunction ofthe Prod uctd ue topr oducts,ac ces sories, or
attachments ofothers ,including batteries,us ed in conjunction withthe Pr oducts. This Warranty is
exclusiv e tothe original Pur chaser and is not ass ignable.
This Warranty is in addition toand does notaffecty our legal rights. Any pr ovision in this warr anty which
is contrary tothe Law in the stateor country wer e theP roduc tis s upplied shall notapply .
GoverningLaw: This disc laimerof warranties and limitedwarr anty are gove rned by the domestic laws
ofIsrael.
Warning
Theus er must followthe Manufacturer’s installation and operationalins tructionsinc luding testingthe
Produc tand its whole s ystem atleast once a week and to take all neces sary precautions for his/her
safetyand thepro tectionofhis /her property.
* Inca se of a conflict,contradictiono r interpretation between theE nglish ver sion of thewar ranty and
otherv ersions ,the English version s hall prevail.
4/18
End-User Lice nse A gree ment
IMPORTAN T- REA D THIS EN D-US ER LICE NSE AGRE EMENT ("E ULA ") CA REFULLY
BE FORE OPE NINGTHE DISK P AC KA GE,D OWNLOADING THE S OFTWARE OR INSTALL ING,
COPY INGOR OTHER WISE US INGTHE SOFTWARE .
THISE ULA IS A LE GAL A GREE MENT BE TWEEN OU AND V ISONIC LTD.(“ TYCO”) A ND
GOVERN S Y OUR USE OF THE S OFTWARE AC COMPANY INGTHIS E ULA, WHICH
SOFTWARE INCLUDES COMPUTER S OFTWARE A ND MAY INCLUDE MED IA,P RINTED
MATERIALS, AN D "ON-LINE" OR ELE CTRONICD OCUMENTATION( COLLECTIVE LY, THE
"SOFTWARE ").B Y BRE AK INGTHE SE AL ON THIS P ACK AGE, DOWNLOA DINGTHE
SOFTWARE OR INSTALLING,COP YING OR OTHERWISE USING THE S OFTWARE, YOU
AGRE E TO BE BOUND BY THE TERMS OF THIS E ULA. IFY OU DO NOTA GREE TO ALL OF
THE TERMS A ND COND ITIONS OF THIS EULA ,D ON OTOP EN, DOWNLOAD, INSTALL, COPY
OR OTHERWISE USE THE S OFTWARE.
1. SCOPE OFLICEN SE. The Software may include c omputercode, progr amfiles and any associatedmedia,har dware or software keys ,printed materialand electronic d ocumentation.The
Software may be provided to you p re-installed on a storage dev ice (the media)as part ofa c omputers ys temor other hardwar e or dev ice (“S ys tem”). The Software is protected by c opyright
laws and internationalco pyright treaties,as well as o therintellectualpro perty laws and treaties.
All title and intellectualproperty rights in and to theS oftware (including butno tlimited toan y
images,photographs, and text incorporated intothe S oftware), the accompanying pr intedmaterials,and any copies o fthe Software,ar e owned by Ty co and/or its suppliers. The Software is
licensed, nots old.All rights notex press ly granted under this E ULA ar e reser ved by Tyco and
itss uppliers.
2. GRANT OFLICENS E. This EU LA gr ants you the followingrights on a non- exclus ive basis:
a.General. This EULA permits you to use the Software for which you have purc hased this
EULA .Onc e you hav e purchas ed licenses for thenumber of copies ofthe Software thatyou
require, you may use theS oftwareand ac companying materialprov ided thatyou ins talland use
no more thanthe licensed n umberof copies atone time.The Software is only licensed for use
withsp ecifiedLicens or-s upplied Sys tems.IftheS oftwareis protectedb y a software or har dware key or other dev ice,the Software may be us ed on any c omputeron wh ich thek ey is
installed.Ifthe key locks theS oftwareto a particular S ystem,the Software may only be us ed on
thatSy stem.
b.Loc ally Stored Components.TheS oftwaremay include a softwarec ode component thatmay
be stored and opera tedlocally on one or more devic es. Once you hav e paid the required
license fees for these devic es (as determinedby Ty co in its sole disc retion),you may ins tall
and/or use one c opy of such c omponentof theS oftwareon each of thedev ices as licensed by
Tyco.Y ou may thenus e,ac ces s,dis play,r un or otherwise interact with ("use") suc h componentof the Software inc onnection withoper atingthe device on which itis installeds olely in the
manner setforth in any ac companying documentationor, in theab sence of suc h,s olely in the
manner contemplated by the nature ofthe So ftware.
c.R emotely S tored Components.The Software may also include a softwarec ode component for
operatingone or more devices remotely.You may installan d/orus e one cop y of such c omponentof the Software on a remotes torage device on an internalnetwork withall ofthe devic es
and may operate such componentwith each dev ice over theinternal network s olely in themanner set forthin any accompanying doc umentation or,in the absen ce of such, solely in the manner contemplatedby the nature of theS oftware;provided ho wever, you must stillac quire the
required number of licenses foreac h ofthe dev ices with which s uch component is to be operated.
d.E mbeddedS oftware/Firmware. TheS oftwaremay als o include a software code c omponent
thatis res identin a devic e as pro vided by Tyc o for operating thatdevice.Y ou may use s uch
componentof theS oftware solely in connec tionwith theus e ofthat device, butmay no tretrieve,
copy or otherwise transfer thatso ftware c omponentto any other mediaor device w ithoutTyco's
expres s prior w rittenauthorization.
e.B ackup Copy.You may make a bac k-up copy of the Software (other thanembedded s oftware) s olely for archiva lpur poses ,which copy may only be used to replace a componentof the
Software forw hich you hav e cur rentv alid license.E xcept as ex press ly prov ided in thisE ULA,
you may not otherwise make copies ofthe Software,inc ludingthe printed materials.
3. OTHER RIGHTSA ND LIMITATIONS.Your us e ofthe S oftware is subject tothe followingaddi-
tionallimitations.Failureto comply withany ofthese r estrictions willr esultin automatictermination ofthis EU LA and w illmake available to Tyco other legal remedies.
a.Limitations on Rev erse E ngineering and Der ivative Works. Y ou may notr evers e engineer,
decompile,or disas semble theS oftware,and any a ttempttodo so shall immediately terminate this
EULA - exc eptan d only to theex tentthatsuc h activitymay be expres sly per mittedby applicable
law notwithstanding this limitation.Y ou may not make any cha nges or modificationsto any por tion
ofthe Software,or create any der ivative works ,w ithoutthewr itten permission of an officer of
Tyco (ex cept as pro vided in Sec tion3(f) of this EULA withr espect to“ open sour ce” s oftware).
You may not remove any proprietary notices, marks o r labels fromthe So ftware. You s hallins titute reas onable measures to ensur e compliance withthe terms and conditions of thisE ULA by
your per sonnel and agents.
b.Copy rightN otices. Y ou mustmaintainall copy rightno tices on allc opies of theS oftware.
c.Tran sfer.You may only transfer your rights under this E ULA (i) as part of a permanents aleo r
transfer ofall ofthe dev ices for which the S oftware is licensed as applicable;(ii) if you transfer all
ofthe Software (including all componentp arts,the mediaand printedmaterials,any upgrades
and thisE ULA );( iii)if you do not retain any c opies of any portion ofthe S oftware; (iv) if ther ecipientagrees tothe terms ofthis E ULA; and (v ) ifthe Software is an upgr ade,s uch transfer must
also include all prior v ersions o fthe Software.You agr ee thatfailureto meetall of these conditionsren ders s uch transfer null and void.
d.Termination.Withoutprejudice to any other rights,Ty co may terminatethis EULA ifyou failto
comply withthe terms and conditions herein. Ins uch ev ent,you must immediatelydes troy all copies ofthe S oftware and all of itsc omponentparts.To the extentthe So ftware is embedded in har dware or firmware, you will provide pr omptacc ess to Tyco o r its represe ntative to remove or lock
Software featuresor functionality as Tyc o determines.
e.S ubsequent EULA . Tyco may also s uperse de thisE ULA witha s ubsequent EUL A purs uant
toprov iding you with any future component,release, upgrade or other modificationor additionto
theS oftware.Similarly,tothe extentthat theterms ofthis E ULA c onflictwitha ny prior E ULA or
othera greementbetween you an d Tyco rega rding theS oftware,the termsof this EULA shall prevail.
f.Incorporation of“Open S ourc e” and other Third Par ty Software. P ortions ofthe So ftware may
be subject toc ertain thirdpar tylicen se agreements gover ning theus e,c opying,modification,
redistributionand war ranty of those portions ofthe Software,inc ludingw hatis commonlyk nown
as “open s ource ” software.A c opy of each applicable third party licens e can be found in the file
REA DME.TXTor other documentation acc ompanying theS oftware.Such open s ource software is not subjec tto any war ranty and indemnitys etforth in thisE ULA.By using the Software
you are als o agreeing to be bound to theterms of such third party licens es.Ifpr ovided for in the
applicable thirdpar ty license, you have a rightto rec eive sour ce code fors uch s oftware for us e
and distributionin any pr ogram thatyou c reate,so long a s you in turn agr ee tobe bou nd tothe
termsof the applicable thirdpar tylicen se,a nd your pr ograms are dis tributedunder the terms of
thatlicense.A copy ofsu ch sour ce co de may be obtainedfree of char ge by co ntactingyour
Tyco repr esentative.
g.Trademarks . This E ULA does not grant you any rights in connection witha ny trademarks or
serv ice marks of Tyco, its affiliatesor itss uppliers.
h.Rental. Y ou may not sublicense, rent,leas e or lend the Software.Y ou may notmake itavailable toothers or post iton a s erver or web s iteor otherwis e distributeit.
i.Software Key s. The hardware/software key ,wher e applicable,is your pr oofof license to exer cise the rights granted herein and must be retained by y ou.Lost or stolen key s will notbe
replaced.
j.Demonstrationand Evaluation Copies. A demonstration or evaluation copy ofthe Software is
cover ed by this EU LA; provided thatthe license s contained herein s hallex pire atthe end of the
demonstrationor ev aluationperiod.
k.R egistrationof Software. The S oftwaremay req uire registrationw ithTyco prior to use.Ifyou
do notr egister theS oftware,this EULA is automatically terminatedand you may notus e theS oftware.
l.Additional Restrictions. The S oftwaremay be s ubject toadditionalr estrictions and conditions
on use as specified in thedoc umentationac companying s uch S oftware, which additionalr estrictionsand conditions are hereby incorpor atedinto and made a part ofthis EU LA.
m.Upgrades and Updates. Tothe extent Tyco makes themavailable,S oftwareupgr ades and
updates may only be use d tore place all or part ofthe original Software thatyou are licensed to
use.S oftware upgr ades and updates do notincr ease the number ofc opies license d toy ou.If
theS oftwareis an upgrade of a component ofa pac kage of Software programs that you licensed
as a single pr oduct,the Software may be used and transferred only as part ofthats inglepr oduct
package and may notbe s eparated for use on more than one computer or S ystem.Software
upgrades an d updates downloaded free of charge v ia a Tyco authorized Wor ld Wide Web or
FTPsite may be used to upgrad e multipleS ys temsprov ided thatyou ar e licensed to use the originalS oftwareon those Sys tems.
n.Tools and U tilities. Software distributedv ia a Tyco- authorized World Wide Web or FTP s ite(or
similarTyc o-authorized distributionmeans) as a tool or utility may be c opied and installedwithout
limitation provided that theS oftwareis notdistributed or sold and the S oftware is only used for the
intendedpurpo se of thetool or utility and in c onjunctionwith Tyco pr oducts.A llother terms and
conditions ofthis EU LA c ontinueto apply.
4. EXPOR TRE STRICTIONS. Y ou agree that you will notex port,re- export or transfer any portionof theS oftware,or any direct product thereof( theforegoing collectively r eferred toas the
"Restricted Components"),to IRAN, NORTH K OREA, S YRIA, CUBA and S UDAN ,including
any entitiesor persons in those countries, eitherdirec tlyo r indirectly (“Tyc o’s P osition”).You
also agree thaty ou will notex port,re- export or transfer the Restricted Components toany other
countries exc eptin full compliance withall applicable gover nmentalrequirements,including but
notlimitedtoapplicab leec onomic sanctions and c onstraints administeredby any Israeli gov ernmentalauthority,including, butnot limited tothe Israeli Ministryof Defense, by any applicable
treaty,applicable expor tco ntrolmeasures administeredby Israel ,U .S.Treas ury Depa rtment
and applicable expor tcon trolmeasures administeredby theU .S.Depar tmentofCommerce
and U.S.D epartmentofS tate,any other U.S.gov ernmentagenc ies, and measures a dministered by the Euro pean Union or the gover nmentagencies ofany other countries.An y violationby y ou of theapplicable laws or regulations of theU.S. or any other government,or w here
you breac h Tyco’s Position notwithstanding whether or not this is contrary toany aforementioned applicable laws or regulations,will result in automatic termination ofthis EU LA.
5. U.S.GOVER NMENT RES TRICTED RIGHTS. The S oftwareis C ommercialComputer Software prov ided with"r estricted rights" under Federal A cquisition Regulationsan d agency supplements to them.Any us e,duplication or disc losure by theU .S.Gover nmentis sub jectto
restrictions as s etforth in subparagr aph (c) (1)(ii) of the Rights inTec hnical Data and Computer
Software clause at DFAR 2 55.227-7013 et.seq. or 252.211-7015, or su bparagraphs (a)
through (d) of theC ommercialComputer Software Restricted Rights atFA R 52.227-19,as
applicable,or s imilarclaus es in the NAS A FA R Supplement.Contractor/manufacturer is
Visonic L td.,24 H abarzel S t.,Tel-Aviv, Israel 69710.
6. LIMITATIONOF LIAB ILITY & EX CLUSION OF DAMAGE S.
a.LIMITATION OFLIAB ILITY. INN OE VE NT WILLTY CO’S A GGREGATE LIAB ILITY
(INCLUDING,B UTN OTLIMITED TO, LIABILITYFOR NE GLIGENCE, STRICT LIABILITY,
BRE ACH OFCONTRA CT,MISREP RES EN TATIONA ND OTHER C ONTRACT OR TORT
CLAIMS) A RISINGFROM OR RELA TED TO THIS EULA , OR THE US E OF THE
SOFTWARE, EX CE ED THE AMOUNT OFFE ES YOU P AID TOTY CO OR ITS RES ELLE R
FORTHE SOFTWARE THAT GIVES RISE TO S UCH LIAB ILITY. BEC AUS E A ND TO THE
EX TENT THAT SOME J URISDICTIONS DO NOTA LLOW THE E XCLU SIONS OR
LIMITATIONS OF LIAB ILITY A BOVE ,THE SE MAY NOT A PP LY TO YOU.
b.EXCLUS IONOF OTHER DAMAGES . UNDE R NO CIRCUMSTANCE S SHA LL TYCO OR
ANY OFITS RE SE LLERS OR LICENS ORS B E LIAB LE FORA NY OF THE FOLLOWING:( I)
THIRDP ARTY CLAIMS;( II)LOSS OR DA MAGE TO ANY SY STEMS, RE CORDS OR DATA,
OR LIABILITIES RELA TED TO A V IOLATIONOF AN INDIVIDUAL'S PR IVACY RIGHTS;OR
(III) INDIRECT,INCIDENTAL, S PE CIAL,CONS EQUE NTIAL,P UNITIVE,R ELIANCE ,OR
COVE R DAMAGE S ( INCLUDINGWITHOUTLIMITATION,LOS S OF PROFITS,B USINES S
INTERRUPTION,LOS S OF DATA OR BUS INESS INFORMATION AND LOST SA VINGS) ,IN
EA CH CA SE EVE N IF TYCO HAS BE EN ADV ISED OF THE P OSS IBILITY OF SU CH
DAMAGE S.Y OU ARE SOLE LY RE SP ONSIBLE AND LIABLE FOR VE RIFYINGTHE
SE CURITY,A CCURA CY AND A DE QUACY OFA NY OUTPUT FROMTHE S OFTWARE,
AND FOR A NY R ELIANCE THERE ON.SOME J URISDICTIONS DO NOT ALLOW THE
EX CLUSION OF INCIDENTAL OR CONS EQUE NTIAL DAMAGE S, OR THE LIMITATIONON
HOW LONG AN IMPLIED WAR RANTY LAS TS,S O SOME OF THE A BOV E LIMITATIONS
MAY A PP LY TO YOU ONLY TO THE EX TENT P ERMITTEDB Y THOS E LA WS.
GENE RAL. Ifany pr ovision of thisE ULA is found tobe unlawful,v oid,or for any reaso n unenforceable,then thatprov ision shall be sev ered from thisE ULA and shall nota ffect thev alidity and
enforceabilityof ther emainingprov isions. You s hould retainpr oofof the license fee paid,including
modelnumber, serial number and date ofpay ment,and present suc h proof ofpay mentwhen s eeking
serv ice or as sistance cov ered by thew arranty set forthin this EU LA.This E ULA is governed by the
laws of Israel,withoutgiving effectto any c hoice or conflictof law provision or rule thatwould c ause the
applicationof thelaws ofany jurisdiction other thanIsrael.E ach of the Parties submits tothe exc lusive
jurisdictionof any court sittingin TelA viv, Israel for purpos es of resolving any and all disputes arising
under or r elatedto these termsa nd conditions.The parties specifically exc lude theapplication of the
provisions ofthe United Nations Convention on Contracts for the InternationalS ale ofGoods .
MC-309 PG2
Contact magnétique sans fil PowerG avec entrées
câblées.
Introduction
Cet appareil est un contact magnétiquesans fil bidirectionnel supervisé PowerG possédant les caractéristiques suivantes:
l Contact magnétiqueintégré
l Enregistrement automatique par r etrait de la languette
l Deux entrées câblées auxiliaires séparées prennent en charge la
programmation normal. fermé (NC), normal. ouvert (NO), fin de
ligne(EOL), double fin de ligne(DEOL) et triple fin de ligne
(TEOL). Possibilité d'utiliser des entrées externes et externes
simultanément. Ces entrées câblées peuvent être programmées
pour uneutilisation avec d'autres capteurs câblés (utilisez
uniquement des capteurs anti-intrusion certifiés UL/ULC)
l Capacités intelligentes de détection de la température
Remarque:la prise en charge d'une seconde entrée auxiliaire,
dela double fin de ligne (DEOL), dela triple fin de ligne(TEOL)
et de la détectionde température dépendent dela version de la
centrale.
Lecontact magnétiqueet les entrées auxiliaires se comportent en tant
qu'émetteurs séparés, bien qu'ils déclenchentle même émetteur
radio.Le retrait du capot active l'autoprotection.S'il est configuré, le
voyant s'éclaire pour signaler des événements d'alarme ou d'autoprotection. Les indicateurs intégrés de qualité de la liaison raccourcissent le temps d'installation en évitantà l' installateur dedevoir
se trouver à proximité physique de la centrale. Les capacités intelligentes de détection de la température émettent une alerte lorsque la
température ambiante atteint un seuil prédéfini.
Pour des instructions détaillées, voir les Instructions d'i nstallation du
D-307661, sur http://www.visonic.com/download-center. Vous pouvez
aussi nous contacter par e-mail à info@visonic.com, afin de
demander uneversion complètedu Manuel d'installation du MC-309
PG2.
Montage de l'appareil
Il est vivement recommandéde fixer l'émetteur en haut du dormant de
la porte/fenêtre et l'aimantsur la porte ou fenêtre. Vérifiez quel'aimant
se trouve à moins de 6mm du côté marqué de l'émetteur.
Remarque: unefois le capot retiré, un m essage d'infraction est
envoyé au récepteur. Le fait de retirer ensuitela pile empêche la transmission dumessaged'appareil rétabli, avec pour effet de laisser le
récepteur en état d'alerte permanente. Pour éviter ceci, appuyez sur le
commutateur d'auto-protection pendant quevous r etirez la batterie.
Attention! L'unitéest dotée d'un commutateur d'autoprotection
arrière enoption, sous la carte à circuits imprimés. Tantquela carte
à cir cuits imprimés est fermement enclenchée dans le socle, le levier
ducommutateur appuie contre le segment détachable fixé peu
solidement au socle. Assurez-vous de fixer le segment détachableau
mur. Si le détecteur est retiré de force du m ur, ce segmentse détache
dusocle et le commutateur d'autoprotections'ouvre.
Remarque:
l L'utilisationde l'autoprotection arrière est obligatoire pour les
installations anti-intrusion professionnelles certifiées UL.
l En Union européenne, n'utilisez pas de bandeadhésive.
Montage à l'aide de vis
1. Une fois le cacheretiré, faites jouer la fixation pour retirer la
carte à circuits imprim és.
2. Marquez et percez deux trous dans la surfacede montage.
3. Alignez l'appareil et l'aimant en utilisantles r epères marqués et
fixez-les à la surfacede montage.
4. Fixez le socle à l'aidede2 vis à tête fraisée.
5. Posez le socle de l' aimant à l'aide des deux vis fournies.
6. Fixez l'aimantau support pour aimant.
Remarque:l'utilisation de l'autoprotectionarrière est obligatoire pour
les installations anti-intrusion professionnelles certifiées UL.
Montage à l'aide de bande adhésive
1. Retirez les protections des deux bandes adhésives double-face
et fixez-les à l'appareil et à l'aimant.
2. Alignez l'appareil et l'aimant en utilisantles r epères marqués et
fixez-les à la surfacede montage.
Enregistrement de l'appareil
1. Allez dans le m enuInstallateur et sélectionnez
02:ZONES/APPAREILS.
2. Sélectionnez AJOUTER DE NOUVEAUX APPAREILS.
3. Retirez la languette pour démarrer la procédure d'enregistrement automatique.
RemarqueSi la centrale ne prend pas en chargel'ID: 110-XXXX,
l'appareil s'enregistre en tant que contact pour fenêtre / porte
avec l'ID: 101-XXXX.
Sinon, appuyez sur le boutond'enregistrement, rétablissez l'autoprotectionou saisissez le numéro d'appareil imprimé sur l'étiquette
(ID: 110-XXXX).
Insertion ou remplacement de la pile
Pour insérer la pile, procédez comme suit:
1. Insérez un tournevis à lame plate dans la fente et poussez vers
le haut pour retirer le capot.
2. Retirez la vis et séparez le capot du socle.
3. Respectez la polarité et r etirez la languette.
4. Connectez le fil du capteur à la borne.
Pour remplacer la pile, procédez comme suit:
1. Retirez le capot.
2. Glissez la lame d'un tournevis plat sous la pile.
3. Faites pivoter le tournevis en vous aidant du socle pour faire
levier, afin deretirer la pile.
Remarque:
l Lorsque vous programmez manuellement des appareils sans fil,
si un appareil a été m is sous tensionpendant plus de 48heures,
il ne peut pas être enregistré dans le système tant quel'appareil
n'a pas été rétabli ou queson autoprotectionn'a pas été retirée.
Lorsque vous programmez la centraleen suivantla procédure
d'Enregistrementrapide, suivez les étapes indiquées dans Enregistrement de l'appareil dans le système.
l Une fois le problème de pile faible résolu, le système peut
mettre jusqu'à cinq minutes pour effacer le problème.
Avertissement: risqued'explosion si vous remplacez la pile par une
pile de type incorrect.Mettez les piles usagées au rebut en suivant les
instructions du fabricant.
AVERTISSEMENT: ce produit contient unepile bouton. L'ingestion
dela pile bouton peut entraîner de graves blessures internes en seulement 2 heures et entraîner la mort. Conservez les piles neuves et
usagées hors de portéedes enfants.Si le compartiment de la pile ne
ferme pas correctement,arrêtez d'utiliser le produit et conservez-le
hors de portée des enfants.Si vous pensez que des piles peuvent
avoir été avalées ou introduites dans une partie du corps, consultez
immédiatement un m édecin.
Détection de pile faible
Remarque: pour les installations certifiées UL, le détecteur ne doit
être utilisé qu'avec des unités de contrôle certifiées UL.
L'appareil inclut unecapacitéde détectionde pile faible. Lorsque cet
état est détecté,unmessagede problème est envoyé au récepteur / à
la centrale compatible. Celui-ci indique visuellement l'unité dont la
pile doit être changée. Pour les installations anti-intrusion professionnelles certifiées UL, remplacez la pile tous les ans.
Remarque:une fois le problème de pile faible résolu,le système
peut mettrejusqu'à cinq minutes pour effacer le problème.
Affichage de la température
Pour connaîtrela procédure d'affichagede la température, voir le
Manuel d'installation de PowerMaster .
Remarque:selonla version dela centrale.
Test de positionnement / test de diagnostic local
Avant d'installer un appareil sans fil demanière définitive, montez l'appareil provisoirement et procédez à un test depositionnement.
1. Séparez le socle de l'appareil du cache.
2. Appuyez unefois sur le commutateur d'autoprotectionet
relâchez-le.
3. Replacez le capot sur l'appareil pour remettre le commutateur
d'autoprotection en position normale (pas d'infraction). Fixez
ensuite le capot avant au socle avec la vis prévueà cet effet.
4. Ouvrez la porte ou la fenêtre et vérifiez que le voyant rouge clignote pour signaler la détection.
5. Au boutde 2 secondes, le voyantclignote 3 fois.
Letableau1 indiquela puissance du signal reçu:
VoyantRéception
Le voyant vert cl ignote 3 foisFort
Le voyant orange c lignote 3 foisBon
Le voyant rouge c lignote 3 foisFaible
Aucun cl ignotementPas de comm.
Important!Seul un signal BON ou FORT est acceptable. Si vous
recevez un signal FAIBLEde l'appareil, changez-le d'emplacement et
recommencez les tests jusqu'à obtenir un signal BON ou FORT.
Tableau 1: puissance du signal
Remarque:
l Pour les installations conformes UL/ULC, seul un signal FORT
est acceptable. Après l'installation, vérifiez le fonctionnement du
produit avec les r écepteurs compatibles de la centrale PowerMaster.
l Pour des instructions de positionnement détaillées, consultez le
Guidede r éférence de la centrale.
Câblage de l'entrée auxiliaire
1. Reliez les contacts du capteur auxiliaire aux bornes de l' entrée
auxiliaire.
2. Si l'entrée auxiliaire est réglée sur NC, vous devez utiliser
exclusivement les contacts du capteur NC reliés en série. Il
n'est pas nécessaire d'utiliser de résistanceen fin de ligne.
3. Si l'entrée auxiliaire est réglée sur NO, vous devez utiliser
exclusivement les contacts du capteur NO reliés en parallèle. Il
n'est pas nécessaire d'utiliser de résistanceen fin de ligne.
4. Pour une supervision defin de ligne, vous pouvez utiliser des
contacts de capteur NC. Une r ésistance EOL 5,6 kΩ doit être
ajoutéeà l' extrémité de la bouclede la zone.
Remarque:
l Pour les installations certifiées UL, l'appareil connecté au circuit
d'originedoit être situé dans la même piècequel'émetteur.
l Pour les installations certifiées UL/ULC, connectez uniquement
des appareils UL/ULC à l'entrée de câblageauxiliaire.
l Un m essage d'alerte est envoyé lorsque la boucle est ouverte ou
court-cir cuitée.
Configuration
LeTableau 3 illustre les options programmables disponibles:
Voyant
d'alarme - Par
défaut - [O]
Contactm agnétique - Par
défaut [O]
Entrées
externes - Par
défaut [O]
Supervision Par défaut [O]
Capteur de
température Par défaut
Activ e le voyant des appareils en c as d'alarme
Remarque:désactivez l e voyant pour préserver l'auto-
nomie de la pil e dans le c adre d'une utili sation professionnelle.
Activ e ou désactive le c ontact magnétique.
Activ e ou désactive l'entrée externe.
Activ e la supervision de l 'appareil
Activ e ou désactive le c apteur de température.
Remarque:selon l a version de la centrale.
Tableau 2:options programmables
Sélections
Zone EO L/DEOL/TEOL- Valeur par défaut[01]
Configure les entrées auxili aires en tant qu'une des options suivantes:
[00] Désac tivé[01] EOL/DEOL/TEOL [02] Normal. ouvert
[03] Normal. fermé
Remarque: les programmations DEOL et TEOL dépendent de la ver-
sion de la centrale.
Tableau 3: Sélections
Sens de couverture de la portée
Surface non-métallique SupportsSurface métallique
OuvertFerméAxeOuvertFermé
21 mm19 mmX16 mm15 mm
27 mm24 mmY12 mm10 mm
13 mm12 mmZ12 mm10 mm
Note:
Les valeurs i ndiquées ci-dessus peuvent v arier de 10%. Pour les
installations c ertifiées UL, les écartements ne peuvent pas dépasser
les v aleurs indiquées ci-dessus . Pour l es i nstallations en aci er, l es
écartements ne peuvent être inférieurs à 3,175mm.
Tableau 4:Sens de couverture de la portée
Caractéristiques techniques
Bande de fréquence: Amérique du Nord et Amérique latine:915
Protocole de communication: PowerG
Entrée alarme: une entréeinterne, deux entrées externes
Supervision:signal toutes les 4 minutes
Alerte d'autoprot ection:émise en cas de sabotage
Type de pile: pile GP 3 V Lithium CR-123A
Autonomie de la pile: 8 ans en utilisationnormale / 5 ans en util-
isationprofessionnelle (voyantdésactivé)
Supervision de la pile: transmission automatique des données sur
l'état de la pile dans le cadre d'unrapport d'état périodique, et immédiatementen cas de détectionde pile faible.
Plage de températures: -10 ºC à +55 ºC. Plage 0 ºC to 49 ºC certifiée uniquement UL/ULC
Humidité relative: HR maximale de 93 % sans condensation
Dimensions ( LxlxP): 81 mm x 34 m m x 25 mm
Poids (avecpile):53 g
Longueur du câble d'entrée auxiliaire: 10 m max, AWG22
Résistancef in de ligne de l'entrée auxiliaire: 5,6KΩ
Installé par un technicien de m aintenance, en intérieur, et dans des
lieux sans danger uniquement.
Niveau de pile faible: 2,5 V
Conformité aux normes
Le contact m agnétique MC-309 PG2 est conforme aux
normes suivantes:
Europe: EN 300220, EN 301489, EN 50130-4, EN 61000-6-3,
EN 62368-1, EN 50131-1, EN 50131-2-6 Grade 2, Clas s II et
EN 50131-6 Type C.
Visoni c Ltd. déclare par la présente que l 'équipement radio de
type MC-309 PG2 est conforme à l a Directive 2014/53/UE.
Le texte complet de la déclaration de conformité européenne
est disponible à l'adresse s uivante:
http://www.visonic.com/download-center
États-Unis: FCC-CFR 47 Part 15, UL-UL 634
Canada: IC-RSS-247, ULC – C634
Classe de sécurité: Conçu conformément aux normes EN
50131-1, EN 50131-2-6 et EN 50131-6 Type C:cet équipement
peut être appliqué aux sys tèmes installés ayant un Security
Grade 2.
Classe environnementale: EN-50131-2-6 Clas s II
Remarque: cet équipement a été testé et déclaré conforme aux limites définies pour les appareils numériques de Classe B, conformément à la Partie 15 de la Réglementation FCC. Ces limites sont
conçues pour fournir uneprotection raisonnable contre les interférences dangereuses en environnement résidentiel. Cet équipement
génère,utilise et peut émettre des fréquences radio, et, s'il n'est pas
installé et utilisé conformément aux instructions, provoquer des interférences altérant les communications radio. Il n'existe toutefois
aucunegarantiequeles interférences ne se produiront pas dans une
installation particulière.Si cet équipement provoquedes interférences
altérant la réception de la radioet de la télévision,ce qui peut être vérifié en l'éteignant et en le rallumant, l'utilisateur est encouragéà
essayer de corriger les interférences en appliquant une ou plusieurs
des mesures suivantes:
- Réorienter ou déplacer l'antennederéception.
- Augmenter la distanceentre l' équipement et le récepteur.
- Brancher l'équipement à uneprise appartenantà un autre circuit électriquequecelui du récepteur.
- Consulter le revendeur ou un technicienradio/TVexpérimentépour
obtenir de l'aide.
Cet équipment a ététestéet jugéconforme aux limites s' appliquant à
unappareil numériquede classe B, conformément à la Partie 15 des
réglementations de la FCC. Ces limites ont été élaborées pour offrir
une protectionraisonnable contre les interferences nuisibles dans une
installation résidentille.