Vision ZP3111IN-5, ZP3111MY-5, ZP3111EU-5, ZP3111RU-5, ZP3111US-5 Installation & Operation Manual

...
Page 1
Federal Communications Commission Statement
ZP 3111-5
V0
1041215
6B1Z-31003
This equipment has been followed to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try and correct the interferene by one of the following measures:
- Reorient or relocate the receiving antenna,
- Increase the separation between the equipment and receiver,
- Connect the equipment into and outlet on a circuit different from that to which the
receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undersired operation. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate this equipment.
Limited Warranty
Vision Guarantees that every wireless PIR sensor is free from physical defects in material and workmanship under normal use for one year from the date of purchase. If the product proves defective during this one-year warrany period, Vision will replace it free of charge. Vision does not issue any refunds. This warnnty is extended to the original end user purchase only and is not transferable. This warranty does not apply to : (1) damage to units caused by accident, dropping or abuse in handling, or any negligent use; (2) units which have been subject to unauthorized repair, taken apart, or otherwise modified; (3) units not used in accordance with instruction; (4) damanges exceeding the cost of the produt; (5) transit damage, initial installation costs, removal cost, or reinstallation cost. For information on addional devices, plesae visit us at www.visionsecurity.com.tw
Installation & Operation Manual
ZP3111IN-5 ZP3111MY-5 ZP3111EU-5 ZP3111RU-5 ZP3111US-5
ZP3111IL-5 ZP3111KR-5 ZP3111HK-5 ZP3111BR-5
ZP3111JP-5
4-in-1 Motion Sensor
(Temp./Humidity/Light Sensor Built-In)
Page 2
Introduction
Specification:
Package Content:
Protocol: Z-Wave (ZM5202) Frequency Range:
865.22MHz (ZP3111IN-5)
868.10MHz (ZP3111MY-5)
868.42MHz (ZP3111EU-5)
869.00MHz (ZP3111RU-5)
908.42MHz (ZP3111US-5)
916.00MHz (ZP3111IL-5)
919.80MHz (ZP3111HK-5)
920.00MHz~923.00MHz (ZP3111KR-5)
921.42MHz (ZP3111BR-5)
922.00MHz~926.00MHz (ZP3111JP-5) Operating Range: Up to 100 feet line of sight Operating Temp.: -10°C~ 40°C (5°F~104°F) Battery: AAA x 2
1pc 1pc 2pc 1pc
ZP 3111 Multi-Sensor Adhesive tape for sensor AAA Alkaline Battery Installation & Operation Manual
- 2 -
(Installation for Information)
(A) – Wall Corner
(C) - Ceiling
(D) – Vertical
(E) - Angled
(B) – Table
- 1 -
Thanks for choosing the Visions wireless 4-in-1 Motion sensor of the home security device. The new multi-sensor consists of motion, temperature, humidity & light sensor for combing several functionality in one device; more attractive and economic consideration. This sensor is a Z-Wave TM enabled device (interoperable, two-way RF mesh networking technology) and is fully compatible with any Z-Wave TM enabled network and its security framework. Every mains powered Z-Wave TM enabled device acts as a signal repeater and multiple devices result in more possible transmission routes which helps eliminate “RF dead-spots”.
Z-Wave TM enabled device displaying the Z-Wave TM logo can also be used with it regardless of the manufacturer, and ours can also be used in other manufacturers Z-Wave
TM
enabled networks. This sensor monitors movement, and send Z-Wave TM signal when movement is detected inside the building. With Temperature, Humidity & Light sensor built inside, it will send the signal out when temperature, humidity & Lightness changed. When the device is secure included into Z-Wave network, above communication will be encrypted.
Product Description and Specification
*** For indoor use only ***
Z-Wave Command Classes:
COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_BATTERY COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_NOTIFICATION_V4 COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_SECURITY COMMAND_CLASS_SENSOR_MULTILEVEL_V7 COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_WAKE_UP_V2
Page 3
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
Size
VALUE
Default
Parameter 1
1
°C
0x00
°C(0x00)
°F
0x01
Parameter 2
1
1~50 (Set up from
0.1°C~5°C)
1 (°C)
Size
VALUE
Default
Parameter 3
1
1~50 (Set up from
1%~50%)
10%
Size
VALUE
Default
Parameter 4
1
0,5~50 (Set up from 0
for Off or 5%~50%)
10%
Size
Value
Parameter 5
1
1 ~ 255 (unsigned decimal) Minutes
(default: 3 minutes)
Parameter 6
1
1 ~ 7
(default: 4)
Size
Value
(Default: Mode 3)
Parameter 7
1
1 ~ 3 (Mode 1 ~ Mode 3) Mode 1 LED Turn Off (Both Temp./PIR Trigger) Mode 2 Temp. (Breathing Light Mode)
PIR (Quick Flash)
Mode 3 LED Quick Flash (Temp./PIR Trigger)
Temperature
LED Color
Under 15°C
Green
15~23°C
Blue
23~28°C
Yellow/YellowGreen
28~36°C
Purple
Over 36°C
Red
Multilevel Sensor Report
Sensor Type
0x01
Scale
0x00 (°C) 0x01 (°F)
Size and Precision
2
- 3 -
- 4 -
Configuration – Temperature
Configuration – Humidity
Configuration – Light
Configuration – Motion Sensor:
(Table 1)
(Parameter 5) Re-trigger duration: User can change value from 1 to 255 minutes to setup the re-trigger time when there is no movement detected in the period of time. Default is 3 minutes. (Parameter 6) Infrared sensor sensitivity adjustment, 7 levels sensitivity, 1 = most sensitive, 7 = most insensitive, default values= 4
Configuration – LED Mode:
Installation
Notice: If you are installing the entire Z-Wave TM system for the first time, please refer to the installation guide of Z-Wave TM Interface Controller before installing ZP3111.
1. Release cover tab to open the cover and insert two AAA battery into the battery compartment and close the cover back to sensor.
2. Press the program switch, the LED will flash 5 times which means the sensor has not been included yet or flash once which means the sensor has been included already.
3. For Inclusion (Auto-Inclusion)” in (adding to) a network: To add the ZP3111 to your
Z-Wave network (inclusion), place your Z-Wave primary controller into inclusion mode. Press the Program Switch of ZP3111 for sending the NIF. After sending NIF, Z-Wave will send the auto inclusion, otherwise, ZP3111 will go to sleep after 20 seconds.
4. For Exclusion” from (removing from) a network: To remove the ZP3111 from your
Z-Wave network (exclusion), place your Z-Wave primary controller into exclusion mode, and following its instruction to delete the ZP3111 to your controller. Press the Program Switch of ZP3111 once to be excluded.
For Association”: Press the program switch for sending NIF, the LED will flash once and send the Wake Up Notification in 5 seconds. Put the Z-Wave TM Interface Controller into association, and following its instruction to associate the ZP3111 with other device. Support grouping identifier=1. Support one association group (5 nodes). “Association” is
used for other grouping devices chain reaction. Red LED will flash once when trigger.
5. Auto Wake Up:
Use “Wake Up” command to set up the awaking time (from 10 minutes to 1 week) and send
the wake up notification to controller
6. Battery Capacity Detection:
* Use “Battery Get” command to have the battery capacity back in %
* It will detect the battery capacity automatically * Low Battery Auto Report when power is lower than 2.6V +/- 0.1V
7. Temperature-If the present temperature is different with the sensor record and exceed the
setting program, the sensor will report the present temperature. LED flash every 3 minutes to represent the temperature or wake up by press the Program SW.
(Caution: Mode 2 will shorten the battery life due to the Breathing Light Mode.)
Page 4
8. Humidity Report- If the present humidity is different with the sensor record and exceed the
Multilevel Sensor Report
Sensor Type
0x05
Scale
0x00 (%)
Size and Precision
2
Multilevel Sensor Report
Sensor Type
0x03
Scale
0x00 (%)
Size and Precision
2
Alarm V1
(Movement & Tamper
Switch)
Notification V4
(Movement)
Notification V4
(Tamper Switch)
Alarm Type
0x07
Alarm Level
0x00 (No movement
after 3 mins)
0xFF (Motion
detected)
Notification Type
0x07
0x07
Notification
Event
0x08(Motion
Detected)/
0x00 (no movement
after 3 mins)
0x03(remove cover)/
0x00 (cover closed)
Notification
Event Parameter
0x08 0x03
- 5 -
- 6 -
setting program, the sensor will report the present humidity.
9. Light Report- If the present illumination is different with the sensor record and exceed the setting program, the sensor will report the present illumination.
10. Factory Default Reset: Remove cover to trigged tamper switch, LED flash once & send out Alarm Report. Press Program Switch 10 times within 10 seconds, ZP3111 will send the Device Reset Locally Notification command and reset to the factory default. (Remark: This is to be used only in the case of primary controller being inoperable or otherwise unavailable.)
Operation
1. Using adhesive tape to mount ZP3111 at 2 meters above surface. To enhance proper operation, place ZP3111 on the location which can detect the room widely.
2. Walk in front of ZP3111, sensor will send Basic set On (0xFF) , Red LED willl flash once and please refer to status report as table below.
3. If no movement detected in three minutes (default is 3 minutes - based on users configuration setting, refer Table 1 (Parameter 5) will send Basic Set OFF (0x00), Red LED will flash once, and refer to table for status.
4. The ZP3111 sensor equipped with tamper switch. If the tamper switch is triggered (or remove the cover), the ZP3111 sensor will send Alarm Report, LED will flash once and refer to table for status.
5. If the tamper switch is closed (or closed the cover), ZP3111 will send Alarm Report, and refer to table for status.
11. All the rest commands depend on Z-Wave standard.
6. Support OTA Firmware update from controller. Please refer to your controller manual
and use COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2. To proceed the OTA process.
7. ZP3111-5 is a Security Enabled Z-Wave Plus product, A Security Enabled Z-Wave controller must be used to fully utilize the product.
Loading...