Vision ZP 3102 EU, ZP 3102 US, ZP 3102 AU Installation & Operation Manual

Page 1
Operation
1. Walk in front of ZP3102, sensor will send the status of “ON” (Basic Set,Value:0xFF) to any associated nodes, and the LED will flash once.
2. If no movement detected in three minut es af ter sent st atu s of “ON”, the sensor will send the status of “OFF” (Basic Set,Value:0x00) to any associated nodes
3. Normal operation, the LED will not light.
Federal Communications Commission Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can ra diate radi o freq uency ener gy and, if not ins tal led and used in accordance with the instruction, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try and correct the interferene by one of the following measures:
- Reorient or relocate the receiving antenna,
- Increase the separation between the equipment and receiver,
- Connect the equipment into and outlet on a circuit different from that to which the
receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this d ev ice may not c au se harm f ul int erf er ence , a nd (2) this device must accept any interference received, including interference that may cause undersired operation. FCC Caution: Any changes or modif icat io ns not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
Limited Warranty
Vision Guarantees that every wireless PIR sensor is free f rom phys ica l defec t s in mater ial and workmanship under normal use for one year from the date of purchase. If the product proves defective during this one-year warrany period, Vision will replace it free of charge. Vision does not issue any refunds. This warnnty is extended to the original end user purchase only and is not tr a nsf erable. This warranty does not apply to : (1) damag e t o units caused by accident, dropping or abuse in handling, or any negligent use; (2) units which have been subject to unauthorized repair, taken apart, or otherwise modified; (3) units not used in accordance with instruction; (4) damanges exceeding the cost of the produt; (5) transit damage, initial installation costs, removal cost, or reinstallation cost. For information on addional devices, plesae visit us at
www.visionsecurity.com.tw
Installation & Operation Manual
ZP 3102 EU ZP 3102 US ZP 3102 AU
Wireless PIR Motion Sensor
ZP 3102 V0 1000824 6B1Z-31001
Page 2
Introduction
Thanks for choosing the Vision’s wireless PIR motion sensor of the home security device. This sensor is a Z-Wave TM enabled device (interoperable, two-way RF mesh networking technology) and is fully compatible with any Z-Wave
TM
enabled network. Every mains
powered Z-Wave
TM
enabled device acts as a signal re peat er and multiple devices result in
more possible transmission routes which helps eliminate “RF dead-spots”. Z-Wave
TM
enabled device displaying the Z-Wave TM logo can also be used with it
regardless of the manufacturer, and ours can also be used in other manufacturer’s Z-Wave
TM
enabled networks. This sensor monitors movement, and send Z-Wave TM signal when
movement is detected inside the building.
Product Description and Specification
*** For indoor use only ***
Specification: Package Content:
Protocol: Z-Wave™ (ZM3102N) Frequency Range:
868.42MHz (ZP3102EU)
908.42MHz (ZP3102US)
921.42MHz (ZP3102AU)
Operating Range: Up to 100 feet line of sight Operating Temp.: -15°C~ 40°C (5°F~104°F) Battery: Panasonic CR123A * 1PC
1pc 1pc 1pc 1pc
ZP 3012 sensor Adhesive tape for sensor CR123A Lithium Battery Installation & Operation Manual
Installation
Notice: If you are installing the entire Z-Wave TM system for the first time, please refer to the installation guide of Z-Wave
TM
Interface Controller before installing ZP3102.
1. Release cover tab to open the cover.
2. Insert a CR123A battery into the battery compartment, and LED will start to flash slowly, which means the sensor has not yet been “inclusion”.
3. Close the cover back to sensor.
-1-
4. For “Inclusion” in (adding to): Put the Z-Wave
TM
Interface Controller into “inclusion” mode, and following its instruction to add the ZP3102 to your controller. To get in the “inclusion” mode, the dist ance betw een sensor and controller is suggeste d to be in one meter. Press the program switch of ZP3102 once. The LED on the ZP3102 should stop flashing, if not, please try again.
For “Exclusion” from (removing from) a network: Put the Z-Wave
TM
Interface Controller into “exclusion” mode, and following its instruction to delete the ZP3102 to your controller. Press the program switch of ZP3102 once to be excluded. The LED
on the ZP3102 should start to flash. For “Association”: removing the cover of the ZP3102 to get into “Awake” mode, then
put the Z-Wave
TM
Interface Controller into “association”, and follow ing it s instr uction t o associate the ZP3102 with other device. Close the cover back after “association” done, afterward the ZP3 102 will get into “Sleep” mo de for po wer saving. Support one association group (5 nodes).
Note: ”Awake” mode: it is to leav e the “Sleep” mode by removing the cover of ZP3102, to allow the Z-Wave
TM
Interface Controller to do “Association”.
5. Using adhesive tape to mount ZP3102 at 2 meters above surface. To enha nc e proper operation, place ZP3102 on the angle which can detect the room widely. The solid area means the detector’s coverage range.
-2-