Federal Communications Commission Statement
This equipment has been followed to comply with Part 15 of the FCC Rules. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try and correct the interference by one of the following measures:
-Reorient or relocate the receiving antenna,
-Increase the separation between the equipment and receiver,
-Connect the equipment into and outlet on a circuit different from that to which the
receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesirable operation. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
Limited Warranty
Vision Guarantees that every wireless siren & strobe alarm is free from physical defects in material and workmanship under normal use for one year from the date of purchase. If the product proves defective during this one-year warranty period, Vision will replace it free of charge. Vision does not issue any refunds. This warranty is extended to the original end user purchase only and is not transferable. This warranty does not apply to : (1) damage to units caused by accident, dropping or abuse in handling, or any negligent use; (2) units which have been subject to unauthorized repair, taken apart, or otherwise modified; (3) units not used in accordance with instruction; (4) damages exceeding the cost of the product; (5) transit damage, initial installation costs, removal cost, or reinstallation cost.
For information on addional devices, plesae visit us at www.visionsecurity.com.tw
Installation & Operation Manual
ZM1621IN-5 ZM1621MY-5 ZM1621EU-5 ZM1621RU-5 ZM1621US-5
ZM1621IL-5 ZM1621KR-5 ZM1621HK-5
ZM1621JP-5
ZM1621BR-5
Outdoor Siren Battery Power
ZM 1621-5
V0
1070613
Page 2
Introduction
Thanks for choosing the Visions wireless outdoor siren & strobe alarm of the home security device. This siren is a Z-Wave enabled device (interoperable, two-way RF mesh networking technology) and is fully compatible with any Z-Wave™ enabled network and it’s security framework. Z-Wave enabled devices displaying the Z-Wave logo can also be used with it regardless of the manufacturer, and ours can also be used in other manufacturers Z-Wave enabled networks. This product will sound a loud siren and flash a strobe light when an alarm message or alert is received on any Z-Wave enabled network. When the device is secure included into Z-Wave network, above communication will be encrypted.
Product Description and Specification
Specification:
Package Content:
Protocol: Z-Wave (ZM5202) Frequency Range:
865.22MHz (ZM1621IN-5)
868.10MHz (ZM1621MY-5)
868.42MHz (ZM1621EU-5)
869.00MHz (ZM1621RU-5)
908.42MHz (ZM1621US-5)
916.00MHz (ZM1621IL-5) 920~923MHz (ZM1621KR-5)
919.80MHz (ZM1621HK-5) 922~926MHz (ZM1621JP-5)
921.42MHz (ZM1621BR-5) Operating Range: Up to 100 feet line of sight Loud Audible Alarm: > 115db@30cm LED Strobe Lighting Operating Temp.: -10°C~ 60°C (14°F~140°F) Battery: 4pcs x UM-1
1pc 4pcs 4pcs 1pc
ZM 1621 Screws UM-1 Batteries User Manual
Z-Wave Command Classes: COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_BATTERY COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_NOTIFICATION_V4 COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_SECURITY COMMAND_CLASS_SWITCH_BINARY (mapping COMMAND_CLASS_BASIC) COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_ZWAVEPLUS_INFO
Installation
Note: If you are installing the entire Z-Wave™ system for the first time, please refer to the installation guide of Z-Wave™ Interface Controller before installing ZM 1621.
1. Remove the bracket from the siren by press the locking tab, and then gently slide up the siren. Observe the correct polarity before insert the batteries.
2. Insert the batteries into ZM1621.
3. Using the screws to affix the bracket on the chosen location.
4.
Slide back the front cover, and then the LED light should go off
.
5. LED Status for Z-Wave Network: After power on, the LED light will flash 25 seconds if the siren has not been included yet. After power on, the LED light will go off if the siren has been included.
-2-
-1-
Page 3
6. For “Inclusion” or Exclusion in (adding to or removing from) a network: Put the Z-Wave™ Interface Controller into inclusion mode, and following its instruction to add the ZM 1621 to your controller. To get in the inclusion mode, get magnet of the bracket to touch the reed switch on the ZM1621 and separate at once to be included. After setting, the LED Light should go off, if not, please try again. (After sending one times Z-Wave NIF and not be included then it will send NWI for auto inclusion. The LED light will flash again if the siren has not been included or the LED light will go off after inclusion.) ZM1621-5 will send NWE if the exclusion could not be done successfully.
Note:
a. LED light will flash continuously in Exclusion condition. b. All user and network settings will be cleared and the device reset to factory defaults when the device is excluded.
For Association: the Z-Wave TM interface controller set “Associati on”, and following its instruction to associate the ZM1621 with other device. ZM1621 will get into “Sleep” mode for power saving. Support grouping identifier=1 (lifeline) Support one association group (=Max 5 nodes). “Association” is used for rear cover notification, low battery report and other grouping devices chain reaction.
For “Configuration”:
Byte
Value
Parameter 1 (Siren/Strobe Mode)
1
0 (All Enable) - Default 1 (Siren Only) 2 (Strobe Only)
Parameter 2 (Alarm Auto Stop Time)
1
0 (30 seconds) - Default 1 (60 seconds) 2 (120 seconds) 3 (Will Not Automatically Stop)
(Parameter 1) Siren/Strobe Mode: User can change value from 0 to 2 to turn either Siren sound, Strobe light, or both when triggered. (Parameter 2) Alarm Auto Stop Time: User can change the duration of siren time when triggered.
7. Support OTA Firmware update from controller. Please refer to your controller manual. We recommend to exclude then include the devices from system after OTA.
8. All the rest commands depend on Z-Wave standard.
Operation
1. Normal operation, the LED light will not on.
2. Alarm Mode: Active: It will active the Alarm Mode after receiving Basic Set (ON) or Binary Switch (ON). The LED Strobe Light & SIREN will be active according to the Configurations setting value. Stop: It will stop the Alarm Mode after receiving Basic Set (OFF) or Binary Switch (OFF) which depends on Configurations setting value. Auto Stop: After stopping alarm, it will send Binary Switch Report (0x00)
3. Self-Protection Mode: After put back the bracket over 5 seconds, ZM 1621 will enter the Self­Protection Mode which will activate LED Strobe Light & SIREN at the same time. The Alarm Mode will be triggered If the back cover has been opened during the Self-Protection Mode The Stop method is same as the Alarm Mode. Open the bracket will send notification after 5 seconds; close the bracket will send another notification after waiting the alarm stop first..
4. Power Level Control: * Use PowerLevel Set Command to set the RF strength during a specific period. * Use PowerLevel Test Node Set Command to test the RF strength for specific node.
5. Battery Capacity Detection:
* Use Battery Get command to have the battery capacity back in % (hexadecimal)
* Auto Battery Capacity Detection in every 2 hours. * Low Battery Report when power is lower than 4.6V +/- 0.2V * Battery Report will be sent by every wake up notification.
6. Security enabled_ Z-Wave controller must be used to fully utilize the product.
7. Support Explorer Frame Function
8. A Security Enabled Z-Wave Controller must be used to fully utilize the products.
9. Power On “Delay Detection Time”: Every Power On will have 10 s econds “Delay Detection
Time” reserved for “Factory Default Reset”. It’s workable only when ZM1621-5 has included.
10. Factory Default Reset: ZM 1621 will reset to factory default when the device has been excluded.
Please use this procedure only in the event that your network primary controllers is missing or
otherwise inoperable!
Alarm
Version 1
Notification
Version 8
Alarm Type
0x07
Alarm Level
0x00 (Trigger) /
0xFF (Non Trigger)
Notification Type 0x07
Notification Event
0x03 (Trigger) /
0x00 (Non Trigger)