VISIOMED Bewell MyOxy User Manual

MyOxy
BW-OX1
BewellConnect - BW-OX1 - User Manual - 072017v21
A
1
3 4
2
B
C
10
1
Readings screen / Pantalla de lecturas / Écran d'affichage
2
USB port / Puerto USB /port USB
3
SpO2level / Nivel de SpO2 / Niveau SpO
4
Pulse rate / Pulso / Fréquence du pouls
5
Bluetooth LED / LED de Bluetooth / Voyant LED Bluetooth
6
Signal indicator / Señal indicadora / Indicateur de signal
7
Battery indicator / Indicador de batería / Indicateur de batterie
2
5
6
7
BewellConnect - BW-OX1 - User Manual - 072017v22
SYMBOLS EXPLANATIONS / PRECAUCIONES DE SEGURIDAD /LEXIQUE DES SYMBOLES
Caution / Advertencia / Attention
Keep dry / Mantener seco / Garder au sec Refer to instruction manual. Note on the equipment “Follow instructions for use”. /
Observación sobre el equipo "Seguir las instrucciones de uso". Observación sobre el equipo "Seguir las instrucciones de uso".Observación sobre el equipo "Seguir las instrucciones de uso". /
Voir le manuel d’instructions. Avis sur l’équipement “Suivre les instructions d’utilisation”. The device, accessories, and the packaging must be disposed of correctly at the end of usage. Please follow local ordinances and regulations for disposal. / El dispositivo, los accesorios y el embalaje deben desecharse de manera adecuada al final de su vida útil. / Por favor, respete las normas y regulaciones locales sobre la eliminación de residuos. /
Le dispositif, ses accessoires et son emballage doivent être recyclés de la façon appropriée au terme de leur utilisation. Veuillez respecter les règlements et règles locaux. Partie appliquée de type flottante conforme aux exigences de la CEI 60601-1 -
protection contre les chocs électriques / F-type applied part complying with the specified requirements of this standard to provide a protection against electric shock
Pulse frequency / Frecuencia de pulso / Fréquence d’impulsion Hemoglobin saturation in oxygen / Saturación de hemoglobina con oxígeno /
SpO
2
Saturation de l’hémoglobine en oxygène Pulse rate (BPM = beats per minute) / Pulso (BPM = latidos por minuto) / Fréquence
PRbpm
du pouls (BPM = battements par minute) No SpO2 alarm / No alarma de SpO2 / Aucune alarme SpO
2
Protection against accidental water spray / Protección contra rociado de agua accidental / Protection contre les projections accidentelles d’eau
SN
Serial number / Número de serie / Numéro de série Federal Communications Commission approval / Aprobación de la Federal
Communications Commission / Approuvé par la Commission Fédérale des Communications
FCC FCC ID: 2AB359322-0B
Electromagnetic energy. Non-ionizing radiation. See EMC data. / Energía electromagnética. Radiaciones no ionizantes. Ver EMC data. / Champ Electromagnétique. Rayonnement non ionisant. Voir EMC data.
3
Serial number
SN
SN :
Year
Month
Day
Serial number
EN
BW-OX1
MyOxy
Compliant with part 15 of the FCC rules.
CONTENTS
1. WARNING ...................................................................................................................... 7
2. PRECAUTIONS BEFORE USE ........................................................................................ 7
3. INFORMATION .............................................................................................................. 8
3.1. OXYGEN SATURATION SPO2 ................................................................................ 8
3.2. PULSE ......................................................................................................................... 10
4. FEATURES ..................................................................................................................... 10
5. USING THE OXIMETER ................................................................................................. 10
5.1. DESCRIPTION ............................................................................................................ 10
5.2. RECOMMENDATIONS BEFORE TAKING MEASUREMENTS ................................... 11
5.3. DOWNLOADING THE APPLICATION ....................................................................... 11
5.4. HOW TO TAKE MEASUREMENTS ............................................................................. 11
6. CLEANING AND MAINTENANCE ................................................................................. 11
7. TECHNICAL SPECIFICATIONS ..................................................................................... 12
8. TROUBLESHOOTING .................................................................................................... 13
Find out how to install and use the BewellConnect® application by visiting our website
www.bewell-connect.us/bewellconnect-app
The manufacturer reserves the right to modify the technical characteristics of the product
without prior notice.
BewellConnect - BW-OX1 - User Manual - 072017v26
Dear Customer, You have just purchased MyOxy, the digital pulse oximeter from BewellConnect® . In order to use it optimally and efficiently, we recommend that you read these operating instructions carefully.
1. WARNING
- Only use this device for the purpose for which it was designed as outlined in this guide.
- This device is adapted for spot-checking in hospitals and hospitals facilities.
- Use this device in a temperature range between 41°F and 104°F / 5°C and 40°C.
- Do not expose this device to extreme temperature conditions (> 158°F / 70°C or < -13°F /
-25°C).
- Do not use this device in over 93% of relative humidity.
- This device must always be kept in a clean and dry place.
- Do not expose the device to sunlight or water.
- Do not expose the device to electric shocks.
- Do not drop the device.
- Follow the maintenance instructions given in this guide.
- Do not try to open the device. In the event of malfunctions, contact your customer service.
- Keep out of reach of children.
- The measurement results are given as a guide. If you have any doubts about your results, please contact your doctor.
- Stop using the device in the event of an anomaly or malfunction.
- This device is not designed for use by people (including children) with reduced physical, sensory or mental capacities, or by people lacking experience or knowledge, unless they are assisted by a person who is responsible for their safety and supervision or who has been given instructions about using this device.
2. PRECAUTIONS BEFORE USE
- Do not use this device near an Electrosurgical Unit (ESU), since it may function incorrectly as a result.
- The pulse oximeter must be placed so that the pulse can be recorded correctly and the main objective is to evaluate the oxygen saturation (SpO with the readings.
) level. Check that nothing is interfering
2
- Do not use the device in an MRI (Magnetic Resonance Imaging) or CT (Computed Tomography) environment.
BewellConnect - BW-OX1 - User Manual - 072017v2 7
- Do not use this device in situations requiring the presence of an alarm.
- Do not use the device in hazardous environment.
- This device is not designed to be used while the user is being transported.
- The device must not be used near or on top of another device.
- Do not use while charging.
- Do not insert anything into the device except the USB cable during charging.
Inaccurate readings may result from :
- Nail-polish (colorimetric interference) or artificial nails
- High levels of dysfunctional hemoglobin (carboxyhemoglobin or methemoglobin)
- Intravascular dyes (indocyanine green or methylene blue)
- Bright light. If necessary, protect the sensor positioning area
- Excessive movement of the user
- Defibrillators and interference from high-frequency electrosurgical devices
- Venous pulse
- Placing the sensor on a user with a blood-pressure cuff, an arterial or intravascular catheter
- High blood pressure, severe vasoconstriction, acute anemia or hypothermia
- Heart failure
- Stress
- Poor pulse quality (low perfusion)
- Low level of hemoglobin.
3. INFORMATION
3.1. OXYGEN SATURATION SPO2
Oxygen saturation is the level of oxygen in red blood cells after they pass through the lungs. Many factors can aect the anity of haemoglobin for oxygen and decrease blood oxygen satu ration. A digital pulse oximeter is non-invasive and can help to monitor SpO
.
2
-
BewellConnect - BW-OX1 - User Manual - 072017v28
ANALYSIS OF RESULTS
Warning : This table does not apply to individuals already suffering from certain illnesses (e.g. asthma, heart disease, respiratory diseases) or who are at altitudes above 4921 feet / 1500 meters. If you are already suffering from a disease, always consult your doctor to analyze your results. If you have any doubts about your results, contact your doctor.
SpO2 (peripheral capillary
oxygen saturation) result as a %
Diagnosis
99 - 95 Normal level
94 - 90 Reduced level (medical visit recommended)
< 90
Reference: World Health Organization (WHO): Pulse Oximetry Training Manual, 2011.
Critical level : consult a doctor immediately or call for
emergency help
FALL IN PERIPHERAL CAPILLARY OXYGEN SATURATION DUE TO ALTITUDE
Please note : The following table gives information about the effects of different altitudes on oxygen saturation levels as well as their effects on the human body. The following table does not apply to individuals already suffering from certain illnesses (e.g. asthma, heart disease, respiratory diseases). In people already suffering from these illnesses, the symptoms (e.g. hypoxia) may already occur at low altitudes.
SpO2
Altitude
(peripheral capillary oxygen
Consequences for the individual
saturation) result as a %
1500 - 2500 m > 90 No mountain sickness (in general)
2500 - 3500 m ~ 90
3500 - 5800 m < 90
5800 - 7500 m < 80
Mountain sickness, adaptation
recommended
High probability of mountain sickness,
adaptation imperative
Severe hypoxia, only a stay for a limited
period of time is possible
7500 - 8500 m < 70 Immediate life-threatening danger
Reference : Hackett PH, Roach RC: High-Altitude Medicine. Dans : Auerbach PS (ed): Wilderness Medicine, 3e édition ; Mosby, St.Louis, MO 1995 ; 1-37.
BewellConnect - BW-OX1 - User Manual - 072017v2 9
3.2. PULSE
Warning: the results below show the average for a person in good health whose measurements
are taken in a calm environment. An individual may have a higher or lower pulse rate as a result of numerous factors (illness, regular exercise, medical treatment, etc.). In the event of irregularities in your results (lower or higher pulse rate than normal), we advise you to consult your physician.
ASSESSMENT OF RESULTS
Normal pulse rate
result (in beats per
minute)
High pulse rate
result (in beats per
minute)
Low pulse rate
result (in beats per
minute)
Age range
120 - 150 > 150 < 120 Infant
80 - 150 > 150 < 80 Child aged 1 - 5
60 - 120 > 120 < 60 Child aged 5 - 12
60 - 105 > 105 < 60 Adolescent
60 - 80 > 100 < 50 Adult
90 - - Elderly person
Reference: Mistovich, Joseph J., Brent Q. Hafen, and Keith J. Karren. Prehospital emergency care. Prentice-Hall, Inc., 2007
4. FEATURES
The digital pulse oximeter is a portable device designed for occasional monitoring of arterial oxygen saturation (as a % of SpO and children, in hospitals, health centers and at home. It should not be used for continuous
) and pulse rate (PR) in beats per minute (bpm) on adults
2
monitoring (it does not include an alarm signalling an abnormal result).
5. USING THE OXIMETER
5.1. DESCRIPTION
See page 2
The Bluetooth LED flashes red when searching for the Bluetooth signal and is fixed red when the connection is made. If the screen shows “?”, it means the signal is unstable. You need to take the reading again.
BewellConnect - BW-OX1 - User Manual - 072017v210
The battery indicator flashes when the battery is low. The device must be recharged using the USB cable
5.2. RECOMMENDATIONS BEFORE TAKING MEASUREMENTS
- When using the device for the first time, charge the battery via the USB port. Connect the USB cable of the device to a computer to charge it. Once the device has been charged, you can disconnect the USB cable.
- Avoid eating, smoking or exercising for 30 minutes before measuring your oxygen saturation.
- Remain calm for 15 minutes before the measurement.
- Keep still and do not speak during the measurement.
5.3. DOWNLOADING THE APPLICATION
The following information may be updated.
Download the BewellConnect® application to your smartphone or tablet :
- via the App Store or Google Play Then click on the MyOxy icon to activate the sub-application. The results are immediately transferred by the application via Bluetooth Low Energy.
5.4. HOW TO TAKE MEASUREMENTS
See figure C page 2
Insert your finger (generally the index finger) into the device. The fingernail must be facing upwards. The device turns itself on automatically when a finger is inserted. The readings appear on the device screen. Wait until the value stabilizes. When the result flashes, the data has been transferred to the application. Important : the data will only be transferred to the application if the application is open while the device is being used and Bluetooth Low Energy is activated. The device switches off automatically after eight seconds. If it is difficult to obtain a reading, try with the other hand or with another finger on the same hand.
6. CLEANING AND MAINTENANCE
- To clean the silicone inside the oximeter that comes into contact with the finger, use 70° rubbing alcohol. Apply the alcohol using a soft clean cloth. Also use the rubbing alcohol to clean the finger being measured, before and after use.
- Do not pour or spray liquid on to the surface of the oximeter. Make sure that liquid does not come into contact with the device openings. Leave the oximeter to dry before using again.
BewellConnect - BW-OX1 - User Manual - 072017v2 11
- Do not sterilize the device in an autoclave, with ethylene oxide or by immersing it in liquid. The device must not be sterilized.
7. TECHNICAL SPECIFICATIONS
Product name BewellConnect® MyOxy Model BW-OX1 Classification Classe II
Applied part type BF
IP22 Display type LED screen LED Specifications Wavelength: Red = 660 ±3nm - Infrared = 905 ±10nm
Radiant power : Red = 3.2mW - Infrared = 2.4mW Dimensions 1.3 x 1.3 x 2.4 in / 32 x 32 x 62 mm Weight 1.41 oz / 40 g Display and
measuring ranges Accuracy SpO
SpO2 : Display range : 35 - 99% / Measuring range : 70 - 99%
Pulse: Display and measuring ranges: 30 - 250 bpm
: 70 - 100% : ± 3%
2
Pulse : ± 2 bpm Resolution SpO
: 1%
2
Pulse : 1 bpm Normal working
conditions
Temperature : 41°F - 104°F / 5°C - 40°C
Humidity : 15-93%RH Storage conditions Temperature : -13°F - 158°F / -25°C - 70°C
Humidity : ≤93%RH
Atmospheric pressure : 86-106Kpa Technology Bluetooth 4.0 Smart Ready Battery Lithium 280mAh Autonomy 400 readings Automatic shut-
8 seconds down
BewellConnect - BW-OX1 - User Manual - 072017v212
Bluetooth
10m transmission distance
Frequency 2400 - 2483.5MHz USB USB port 2.0 Accessories
Pulse oximeter, instruction manual, protective pouch, USB cable provided
8. TROUBLESHOOTING
If one of the following issues arises when using your MyOxy, consult this trouble-shooting guide. If the problem continues, please contact our customer service department at
www.support.bewell-connect.com.
ISSUE POSSIBLE CAUSE SOLUTION
Sp02 or PRbpm do not appear correctly
Sp02 or PRbpm are unstable
Your finger must be correctly inserted.
reading
SpO
2
too small to be measured.
Your finger may not be inserted deeply
Change the position of your finger and try again.
Try several times. If you have any doubts about a problem related to the product, seek medical attention to obtain an accurate diagnosis.
Change the position of your finger and try again.
enough.
The user’s finger is trembling or the
Try not to move.
user is moving.
Impossible to turn on the device
Battery low Recharge the device with the USB cable
Oximeter is damaged Contact customer service
BewellConnect - BW-OX1 - User Manual - 072017v2 13
The indicator lights turn off
The device switches itself off automatically after eight seconds
Normal
when a signal is not detected. Low battery Recharge the device with the USB cable
Error3 Low battery Recharge the device with the USB cable
Oximeter is damaged Contact customer service
Error7
Low battery Recharge the device with the USB cable
Oximeter is damaged Contact customer service
Bluetooth
No data transferred to your smartphone/ tablet
connection deactivated
Smartphone or tablet incompatible
Activate the Bluetooth on your smartphone/tablet
Check that your smartphone or tablet has Bluetooth 4.0 Smart Ready and that your operating system is up to date (Android version 4.3 or later Or iOS version 7.1 or later)
BewellConnect - BW-OX1 - User Manual - 072017v214
SP
BW-OX1
MyOxy
BewellConnect - BW-OX1 - User Manual - 072017v2 15
En cumplimiento con las normas europeas y con el apartado 15 de las reglas de la FCC.
CONTENIDO
1. ADVERTENCIA .............................................................................................................. 17
2. PRECAUCIONES ANTES DE UTILIZAR ........................................................................ 17
3. INFORMACIÓN ............................................................................................................. 18
3.1. SATURACIÓN DE OXÍGENO SPO
3.2. PULSO ........................................................................................................................ 20
 .......................................................................... 18
2
4. CARACTERÍSTICAS ....................................................................................................... 21
5. UTILIZACIÓN DEL OXÍMETRO ..................................................................................... 21
5.1. DESCRIPCIÓN ............................................................................................................ 21
5.2. RECOMENDACIONES ANTES DE REALIZAR LAS MEDICIONES ............................ 21
5.3. DESCARGA DE LA APLICACIÓN ............................................................................... 21
5.4. CÓMO REALIZAR LAS MEDICIONES ........................................................................ 21
6. LIMPIEZA Y MANTENIMIENTO ................................................................................... 22
7. ESPECIFICACIONES TÉCNICAS ................................................................................... 22
8. RESOLUCIÓN DE PROBLEMAS .................................................................................... 24
Aprenda a instalar y utilizar la aplicación BewellConnect® visitando nuestro sitio web
www.bewell-connect.us/bewellconnect-app
El fabricante se reserva el derecho de modificar las especificaciones técnicas del producto sin
aviso previo.
BewellConnect - BW-OX1 - User Manual - 072017v216
Loading...
+ 36 hidden pages