VISIO BW-108 User Manual

NO.011
Building Wash
BW-108
User Guide
BW-108
1B
TABLE OF CONTENTS
1. Safety Instruction
2. Technical Specification
3. Change Beam Angle
4. Main Function
5. How To Control The Unit
6. Troubleshooting
7. Fixture Cleaning
BW-108
18B
BW-108
17B
EC Declaration of Conformity
We declare that our products (lighting equipments) comply with the
following specification and bears CE mark in accordance with the
provision of the Electromagnetic Compatibility (EMC) Directive
89/336/EEC.
EN55014-2: 1997 A1: 2001, EN61000-4-2: 1995; EN61000-4-3:
2002;
EN61000-4-4: 1995; EN61000-4-5: 1995, EN61000-4-6: 1996,
EN61000-4-11: 1994.
&
Harmonized Standard
EN60598-1: 2000+ALL: 2000+A12: 2002
Safety of household and similar electrical appliances
Part 1: General requirements
BW-108
2B
Accessories:
Signal cable 2pcs
) 0.36m Male water proof connector + female XLR connector cable x
1pc
) 0.36m Female water proof connector + male XLR connector cable x
1pc
Power cable 1pc
) 1.5m Water proof connector + plug x 1pc
Option (sold separately):
) 10m Power cable (water proof connector male/female) ) Signal cables for linking fixtures, available length: 1m (CCT-1), 2m
(CCT-2), 5m (CCT-5) or 10m (CCT-10 )
1. Safety Instruction
WARNING
y Please keep this User Guide for future consultation. If you sell the unit to another
user, be sure that they also receive this instruction booklet.
y Unpack and check carefully there is no transportation damage before using the
unit.
y Before operating, ensure that the voltage and frequency of power supply match
the power requirements of the unit.
y It’s important to ground the yellow/green conductor to earth in order to avoid
electric shock.
y Suitable for both indoor & outdoor use. y The unit must be installed in a location with adequate ventilation, at least 50cm
from adjacent surfaces.
y Disconnect mains power before replacement or servicing. y Make sure there is no flammable materials close to the unit while operating as it is
fire hazard.
Please read carefully the instruction which includes important information about the installation, usage and maintenance.
BW-108
3B
y Use safety cable when fixes this unit under ceiling or on the truss. y Maximum ambient temperature is ta: 40 . Don’t operate it where the temperature
is higher than this.
y Unit surface temperature may reach up to 60 . Don’t touch the housing
bare-hand during its operation. Turn off the power and allow about 15 minutes for the unit to cool down before replacing or serving.
y In the event of serious operating problem, stop using the unit immediately. Never
try to repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type spare parts.
y Do not touch any wire during operation as high voltage might be causing electric
shock.
Warning
y Do not open the unit within five minutes after switching off. y Make sure that the housing is firmly closed and all screws are tightly fastened
when operate.
Caution
There are no user serviceable parts inside the unit. Do not open the housing or attempt any repair yourself. In the unlikely event your unit may require service, please contact your nearest dealer.
Installation
The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 20 times of the unit.
For power supply, do not connect in series much more than 4 units, use another mains supply for next 4 units.
BW-108
16B
6. Troubleshooting
Following are a few common problems that may occur during operation. Here are some suggestions for easy troubleshooting:
A. The unit does not work, no light output
1. Check the connection of power.
2. Measure the mains voltage on the main connector.
B. Not responding to DMX controller
1. Check DMX connectors, cables to see if link properly.
2. Check the address settings.
3. If you have intermittent DMX signal problems, check the pins on connectors of the unit or the previous one.
4. Try to use another DMX controller.
5. Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit.
7. Fixture Cleaning
The cleaning of and external optical lenses must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit’s optics.
y Clean with soft cloth using normal glass cleaning fluid. y Always dry the parts carefully. y Clean the external optics at least every 20 days.
BW-108
15B
5.4 DMX512 Connection
1. If you using a controller with 5 pins DMX output, you need to use a 5 to 3 pi n adapter-cable.
2. At last unit, the DMX cable has to be termina ted with a terminator. Solder a 120 ohm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in the DMX-output of the last unit.
3. Connect the unit together in a `daisy chain` by XLR plug from the output of the unit to the input of the next unit. The cable can not branched or split to a `Y` cable. DMX 512 is a very high-speed signal. Inadequate or damaged cables, soldered joints or corroded connectors can easily distort the signal and shut down the system.
4. The DMX output and input connectors are pass-through to maintain the DMX circuit, when one of the units’ power is disconnected.
5. Each lighting unit needs to have an address set to receive the data sent by the controller. The address number is between 0-511 (usually 0 & 1 are equal to 1).
6. The end of the DMX 512 system should be terminated to reduce signal errors.
7. 3 pin XLR connectors are more popular than 5 pin XLR. 3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+) 5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+),
Pin 4/5: Not used
BW-108
4B
2. Technical Specification
y DMX 12/9/4 channels selectable y LED display with password protection at the rear panel y Come with great built-in programs (16 chases) and 3 editable chases y Using the latest LED technology makes important energy (cost) savings compared
to traditional halogen fixtures.
y Completely silent, the projector is cooled by natural air convection without fan y Thermal sensor in LED PCB to protect LEDs from over heated. y With waterproof IP66 housing, it perfect to illuminate all ki nds buil di ngs like: hotels,
shops, discotheques, stage, amusement parks, fairground, museum, etc.
y Voltage:100-240V~50/60Hz y Power consumption: 150W y Light source: 108×1W LED
50,000hrs rated
y Beam Angle: as indicated on the product label (15°/25°/45° are available) y Dimension: 582×185×251 mm y Weight: 18.4 kgs
BW-108
5B
3. Change Beam Angle
We don’t recommend to change the lens of the fixture. However, if you have to change the beam angle of the fixture, you can change lens of the fixture refer to the photo below:
Important: As it is a water-proof fixture, changing lens of this unit should be carried out by qualified technician and make sure everything is intact for water-proof.
4. How To Control The Unit
4.1 Rear Panel
Display-water proof touch screen
Touch screen to choose and show menus
Power Water proof connectors for power input/output DMX input/output
Water proof connectors for DMX 512 operation, use 3-pin XLR plug cable to link the unit together
BW-108
14B
9 Channels:
4 Channels:
BW-108
13B
5.3 DMX 512 Configuration
12 Channels:
BW-108
6B
4.2 Main Function
To select any of the given functions, press the MENU button up to when the require d one is showing on the display. Select the function by ENTER button and the display will blink. Use DOWN and UP button to change the mode. Once the required mode has been selected, press the ENTER button to setup or it will automatically return to the main functions without any change after idling 8 seconds. To go back to the functions without any change press the MENU button. The main functions are showing below:
BW-108
7B
DMX 512 Address Setting
Press the MENU button up to when the
is shown on the display. Pressing ENTER button and the display will blink. Use DOWN and UP button to change the DMX 512 address. Once the address has been selected, press ENTER button to setup or automatically return to the main functions without any change after 8 seconds. Back to the previous functions without any change press MENU button.
Channel Mode
Press the MENU button up to when the
is shown on the display. Pressing ENTER button and the display will blink. Use DOWN and UP button to select the
(12 channels) or (9 Channels) or (4 channels) mode. Once
Once you set to , after running in show mode for 5 minutes without any change or restarting the unit, the key board become locked. Press ENTER button to enable the menu, the display
will show
, press UP and DOWN button until it shows ,
BW-108
12B
Press the MENU button up to when the is showing on the display. Pressing ENTER button and the display will blink. Use DOWN and UP button to change the DMX512 address. Once the address has been selected, press and keep ENTER button up to when the display stops blinking or storing automatically 8 seconds later. To go back to the functions without any change press the MENU button again. Please refer to the following diagram to address your DMX512 channel for the first 4 units
12 Channels:
9 Channels:
4 Channels:
BW-108
11B
Press the MENU button up to when the is blinking on the display. Pressing ENTER button and the display will show the temperature of the unit. To go back to the functions press the MENU button again.
Fixture Hours
Press the MENU button up to when the
is blinking on the display. Pressing
ENTER button and the display will show the number of working hours of the unit. To go back to the functions press the MENU button.
Software version
Press the MENU button up to when the is blinking on the display. Pressing ENTER button and the display will show the version of software of the unit. To go back to the functions press the MENU button.
5. How To Control The Unit
You can operate the unit in two ways:
1. By master/slave built-in preprogram function
2. By universal DMX controller No need to turn the unit off when you change the DMX address, as new DMX address setting will be effected at once. Every time you turn the unit on, it will show
on the display, after that the unit will be ready to receive DMX signal or r un
the built in programs.
5.1 Master/Slave Built In Preprogrammed Function
By linking the units in master/slave connection, the first unit will control the other units to give an automatic show. This function is good when you want an instant show.
You have to select (show 1) or (show 2) ……or (show 19, show17~19 have to be edited by the user) show for the first unit. Its DMX input jack
will have nothing plugged into. The other units will be slave mode automatic.
5.2 Universal DMX Controller
Use universal DMX controller to control the units, you have to set DMX address from 1 to 512 channel so that the units can receive DMX signal.
BW-108
8B
the mode has been selected, press the ENTER button to setup or automatically return to the main functions without any change after 8 seconds. To go back to the previous functions without any change press the MENU button.
Show Mode
Press the MENU button up to when the is showing on the display. Pressing ENTER button and the display will blink. Use DOWN and UP button to select the
(show 1) or (show 2) …… or (show 19) sho w. Once the show has been selected, press the ENTER button to setup or automatically return to the main functions without any change after 8 seconds. To go back to the previous
functions without any change press the MENU button.
Blackout Mode
Press the MENU button up to when the
is showing on the display. Pressing
ENTER button and the display will blink. Use DOWN and UP button to select the
(yes blackout) or (no blackout) mode. Once the mode has been
selected, press the ENTER button to setup or automatically return to the main functions without any change after 8 seconds. To go back to the previous functions without any change press the MENU button.
Program Shows
Press the MENU button up to when the
is showing on the display. Pressing
ENTER button and the display will blink. Use DOWN and UP button to select the
(show 17) or show 18)or (show 19) show. Once the show has been selected, press the ENTER button to enter setting program. You can select
(length, the steps, you choose from the total amount of steps, you want to run, for example, if the total amount of steps you set is 50, you can choose only first 1-10 steps to run).
(step), select to set (color) and (dimmer) for every step. Automatically return to the main functions without any change after 8 seconds. To go back to the previous functions without any change press the MENU button. For dimmer, the function corresponds to the value shown below:
BW-108
9B
value function
0-199 Dimmer from 0% to 100% 200—247 Strobe from slow to fast 248-255 Open
Manual Mode
Press the MENU button up to when the is showing on the display. Pressing ENTER button and the display will blink. Use DOWN and UP button to select the
(red, 1 for 1section, 2 for 2 section, 3 for 3 section ) or , (green)or (blue) or
(dimmer) or
(strobe) mod e. Once the mode has been selected, press the ENTER button to setup or automatically return to the main functions without any change after 8 seconds. To go back to the previous functions without any change press the MENU button. For strobe, the function corresponds to the value shown below:
value function value function
0-7 OFF 182-189 Open 8-15 Open 190-231 Slow close fast open 16-131 Strobe from slow to fast 232-239 Open 132-139 Open 240-247 Random strobe 140-181 Slow open fast close 248-255 Open
Adjust White Balance
Press the MENU button up to when the is showing on the display. Pressing ENTER button and the display will blink. Use DOWN and UP button to select the
(red) or (green) or (blue) mode. Once the mode has been selected, press the ENTER button to setup or automatically return to the main functions without any change after 8 seconds. To go back to the previous functions without any change press the MENU button.
Self-Test
Press the MENU button up to when the is blinking on the display. Pressing
BW-108
10B
ENTER button and the unit will run self-test by built-in program. To go back to the previous functions press the MENU button.
LED
Press the MENU button up to when the
is shown on the display. Pressing
ENTER button and the display will blink. Use DOWN and UP button to select the
(display on) or (display off) mode. Once the mode has been selected, press ENTER button to setup or automatically return to the main functions without any change after 8 seconds. To go back to the previous functions without any change press the MENU button.
Display Inversion
Press the MENU button up to when the
is showing on the display. Pressing
ENTER button and the display will blink. Use DOWN and UP button to select the
(normal) or (inversion) mode. Once the mode has been selected,
press the ENTER button to setup or automatically return to the main functions without any change after 8 seconds. To go back to the previous functions without any change press the MENU button.
DMX Control Mode
Press the MENU button up to when the
is shown on the display. Pressing
ENTER button and the display will blink. Use DOWN and UP button to select the
(DMX control) or (manual control) mode, press the ENTER button to confirm. If
is selected, use DOWN and UP button to select or
… or , press ENTER button to confirm, then use DOWN and UP button to adjust wait time or speed or dimmer, press ENTER button to store or
automatically return to the main functions without any change after 8 seconds. Back to the previous functions press MENU button.
Key Board Lock
Press the MENU button up to when the
is shown on the display. Pressing
ENTER button and the display will blink. Use DOWN and UP button to select the
(key board lock) or (normal). Once select, press the ENTER button to setup or automatically return to the main functions without any change after 8
seconds. Back to the previous functions press MENU button.
Temperature Test
Loading...