The CNY75(G) series consists of a phototransistor
optically coupled to a gallium arsenide infraredemitting diode in a 6-lead plastic dual inline package.
The elements are mounted on one leadframe using
a coplanar technique, providing a fixed distance
between input and output for highest safety
requirements.
Applications
Vishay Telefunken
Circuits for safe protective separation against
electrical shock according to safety class II
(reinforced isolation):
D
For appl. class I – IV at mains voltage ≤ 300 V
D
For appl. class I – III at mains voltage ≤ 600 V
according to VDE 0884, table 2, suitable for:
Switch-mode power supplies, line receiver, computer peripheral interface, microprocessor
system interface.
VDE Standards
These couplers perform safety functions according
to the following equipment standards:
D
VDE 0884
Optocoupler for electrical safety requirements
D
IEC 950/EN 60950
Office machines (applied for reinforced isolation
for mains voltage ≤ 400 V
D
VDE 0804
Telecommunication apparatus and data
processing
D
IEC 65
Safety for mains-operated electronic and related
household apparatus
ParameterTest ConditionsSymbolV alueUnit
AC isolation test voltage (RMS)t = 1 minV
Total power dissipationT
Ambient temperature rangeT
Storage temperature rangeT
Soldering temperature2 mm from case, t ≤ 10 sT
≤ 25°CP
amb
≤ 25°CP
amb
≤ 25°CP
amb
R
F
FSM
V
CBO
CEO
ECO
C
CM
V
IO
tot
amb
stg
sd
5V
60mA
3A
100mW
j
125
°
C
90V
90V
7V
50mA
100mA
150mW
j
125
°
C
3.75kV
250mW
–55 to +100
–55 to +125
260
°
C
°
C
°
C
Rev. A4, 11–Jan–99142
CNY75(G) Series
CF
CEF
CEF
Vishay Telefunken
Electrical Characteristics (T
amb
= 25°C)
Input (Emitter)
ParameterTest ConditionsSymbolMin.Typ.Max.Unit
Forward voltageIF = 50 mAV
Reverse currentVR = 6 VI
Junction capacitanceVR = 0, f = 1 MHzC
Maximum Safety Ratings (according to VDE 0884) see figure 1
This device is used for protective separation against electrical shock only within the maximum safety ratings.
This must be ensured by using protective circuits in the applications.