Vishay Telefunken BYT106-1300 Datasheet

Fast Recovery Silicon Power Rectifier
Features
Multiple diffusion
Low switch on power losses
Good soft recovery behaviour
Fast forward recovery time
Fast reverse recovery time
Low reverse current
Very good reverse current stability at high tem­perature
Low thermal resistance
Applications
Fast rectifiers in S.M.P.S Freewheeling diodes and snubber diodes in motor control circuits
BYT106/1300
Vishay Telefunken
14282
Absolute Maximum Ratings
Tj = 25_C
Parameter Test Conditions Type Symbol Value Unit
Reverse voltage =Repetitive peak reverse voltage
Peak forward surge current tp=10ms,
half sinewave Repetitive peak forward current I Average forward current I Junction and storage temperature range Tj=T
VR=V
I
Maximum Thermal Resistance
Tj = 25_C
Parameter Test Conditions Symbol Value Unit Junction case R Junction ambient R
thJC thJA
FSM
FRM
FAV
RRM
stg
1300 V
50 A
15 A
5 A
–40...+150
2.4 K/W 85 K/W
°
C
Document Number 86018 Rev. 2, 24-Jun-98
www.vishay.de FaxBack +1-408-970-5600
1 (5)
BYT106/1300
g
F
,
F
m
Vishay Telefunken
Electrical Characteristics
Tj = 25_C
Parameter Test Conditions Type Symbol Min Typ Max Unit
Forward voltage IF=5A V
IF=5A, Tj=100°C V
Reverse current VR=V
Forward recovery time
VR=V I
=5A, di
RRM
, Tj=100°C I
RRM
/dtx50A/ms
Turn on transient peak voltage Reverse recovery time IF=0.5A, IR=1A, iR=0.25A t
Characteristics (Tj = 25_C unless otherwise specified)
I
R R
t
fr
V
FP rr
F F
1.9 V
1.9 V 10
m
A
0.2 mA
350 ns
7 V
120 ns
100
10
m
1
0.1
R
I – Reverse Current ( A )
94 9495
0.01 0 40 80 120 160
Tj – Junction Temperature ( °C )
200
Figure 1. Typ. Reverse Current vs. Junction Temperature
6
5
R
=2.4K/W
4
R
=5K/W
thJA
3
R
=10K/W
2
1
FAV
I – Average Forward Current ( A )
0
thJA
R
=85K/W
thJA
0
40 80 120 160
T
– Ambient Temperature ( °C )94 9493
amb
thJC
200
100
10
T
=100°C
Case
1
T
=25°C
F
I – Forward Current ( A )
94 9494
0.1
0.01 0 0.6 1.2 1.8 2.4
Case
3.0
VF – Forward Voltage ( V )
Figure 3. Typ. Forward Current vs. Forward Voltage
800
600
400
200
rr
Q – Reverse Recovery Charge ( nC )
94 9496
0
01 2 3 4
I
– Forward Current ( A )
F
6
5
Figure 2. Max. Average Forward Current vs.
Figure 4. Reverse Recovery Charge vs. Forward Current
Ambient Temperature
www.vishay.de FaxBack +1-408-970-5600 2 (5)
Document Number 86018
Rev. 2, 24-Jun-98
Loading...
+ 3 hidden pages