For detailed tape specifications refer to “Packaging Information” www.vishay.com/doc?28139
or end of catalog
SPECIFIC REFERENCE DATA
DESCRIPTIONVALUE
Tangent of loss angle: at 1 kHzat 10 kHzat 100 kHz
C = 0.1 µF
0.1 µF ≤ C = 1.0 µF
C ≥ 1.0 µF
Capacitor length
(mm)
111218325684141113223766175
197813213365
26.5458131934
31.5346101525
41.523571017
R between leads, for C ≤ 0.33 µF and U
R between leads, for C ≤ 0.33 µF and U
RC between leads, for C > 0.33 µF and U
RC between leads, for C > 0.33 µF and U
R between leads and case, 100 V; (foil method)> 30 000 MΩ
Withstanding (DC) voltage (cut off current 10 mA); rise time 100 V/s1.6 x U
Maximum application temperature100 °C
63 Vdc100 Vdc250 Vdc400 Vdc630 Vdc1000 Vdc
If the maximum pulse voltage is less than the rated voltage higher dU/dt values can be permitted.
The capacitors are designed for mounting on printed-circuit boards. The capacitors packed in bandoliers are designed for
mounting in printed-circuit boards by means of automatic insertion machines.
For detailed tape specifications refer to Packaging information: www.vishay.com/doc?28139
Specific Method of Mounting to Withstand Vibration and Shock
In order to withstand vibration and shock tests, it must be ensured that the capacitor body is in good contact with the printed-circuit
board:
• For L ≤ 19 mm capacitors shall be mechanically fixed by the leads
• For larger pitches the capacitors shall be mounted in the same way and the body clamped
• The maximum diameter and length of the capacitors are specified in the dimensions table
• Eccentricity as shown in the drawing below
(1)
or end of catalog.
PACKAGING CODE
Space Requirements On Printed-Circuit Board
The maximum length and width of film capacitors is shown in the drawing:
• Eccentricity as in drawing. The maximum eccentricity is smaller than or equal to the lead diameter of the product concerned.
• Product height with seating plane as given by “IEC 60717” as reference: h
1 mm
≤ h + 0.4 mm or h
max.
≤ h' + 0.4 mm
max.
Storage Temperature
• Storage temperature: T
= - 25 °C to + 40 °C with RH maximum 80 % without condensation
stg
Ratings and Characteristics Reference Conditions
Unless otherwise specified, all electrical values apply to an ambient temperature of 23 ± 1 °C, an atmospheric pressure of 86 kPa
to 106 kPa and a relative humidity of 50 ± 2 %.
For reference testing, a conditioning period shall be applied over 96 ± 4 h by heating the products in a circulating air oven at the
rated temperature and a relative humidity not exceeding 20 %.