PD -2.471 rev. B 01/99
HF A80NC40CSM
TM
Ultrafast, Soft Recovery DiodeHEXFRED
Features
• Reduced RFI and EMI
• Reduced Snubbing
• Extensive Characterization of
Recovery Parameters
VR = 400V
VF(typ.) = 1V
I
= 80A
F(AV)
Qrr (typ.) = 200nC
I
(typ.) = 6A
RRM
trr(typ.) = 30ns
di
/dt (typ.) = 190A/µs
(rec)M
Description
HEXFREDTM diodes are optimized to reduce losses and EMI/RFI in high frequency
power conditioning systems. An extensive characterization of the recovery
behavior for different values of current, temperature and di/dt simplifies the
calculations of losses in the operating conditions. The softness of the recovery
eliminates the need for a snubber in most applications. These devices are ideally
suited for power converters, motors drives and other applications where
switching losses are significant portion of the total losses.
SMD -61-8
Absolute Maximum Ratings (per Leg)
Parameter Max. Units
V
R
IF @ TC = 25°C Continuous Forward Current 85
IF @ TC = 100°C Continuous Forward Current 42 A
I
FSM
E
AS
PD @ TC = 25°C Maximum Power Dissipation 150
PD @ TC = 100°C Maximum Power Dissipation 59
T
J
T
STG
Cathode-to-Anode Voltage 400 V
Single Pulse Forward Current 300
Non-Repetitive Avalanche Energy 1.4 mJ
Operating Junction and
Storage Temperature Range
Soldering Temperature, for 10 sec. 300 (0.063 in. (1.6mm) from case)
-55 to +150 °C
W
Thermal - Mechanical Characteristics
Parameter Min. Typ. Max. Units
R
thJC
Wt Weight –––– 4.3 (0.15) –––– g (oz)
Note: Limited by junction temperature
L = 100µH, duty cycle limited by max T
125°C
Junction-to-Case, Single Leg Conducting –––– –––– 0.85
Junction-to-Case, Both Legs Conducting –––– –––– 0.42
J
°C/W
K/W
1
HF A80NC40CSM
PD-2.471 rev. B 01/99
Electrical Characteristics (per Leg) @ TJ = 25°C (unless otherwise specified)
Parameter Min. Typ. Max. Units Test Conditions
V
BR
V
FM
I
RM
C
T
L
S
Dynamic Recovery Characteristics (per Leg) @ TJ = 25°C (unless otherwise specified)
t
rr
t
rr1
t
rr2
I
RRM1
I
RRM2
Q
rr1
Q
rr2
di
(rec)M
di
(rec)M
Cathode Anode Breakdown Voltage 400 ––– ––– V IR = 100µA
Max Forward Voltage ––– 1.1 1.3 IF = 40A
––– 1.3 1.5 V IF = 80A
––– 1.0 1.2 IF = 40A, TJ = 125°C
Max Reverse Leakage Current ––– 0.50 3.0 µA VR = VR Rated
––– 0.75 4.0 mA TJ = 125°C, VR = 320V
Junction Capacitance ––– 9 0 125 pF VR = 200V
Series Inductance ––– 5.5 – –– nH Lead to lead 5mm from package body
Parameter Min. Typ. Max. Units Test Conditions
Reverse Recovery Time ––– 30 ––– IF = 1.0A, dif/dt = 200A/µs, VR = 30V
––– 67 100 ns TJ = 25°C
––– 110 170 TJ = 125°C IF = 40A
Peak Recovery Current ––– 6. 0 11 TJ = 25°C
––– 9.0 16 TJ = 125°C VR = 200V
Reverse Recovery Charge ––– 2 00 540 TJ = 25°C
––– 500 1300 TJ = 125°C dif/dt = 200A/µs
/dt1 Peak Rate of Fall of Recovery Current ––– 240 ––– TJ = 25°C
/dt2 During t
b
––– 190 ––– TJ = 125°C
A
nC
A/µs
See Fig.
5
See Fig.
6
See Fig.
7
See Fig.
8
See Fig. 1
See Fig. 2
See Fig. 3
Dimensions in millimeters and (inches)
Outline D61- 8-SM
2