Vishay 40EPF User Manual

40EPF.. Soft Recovery Series
Fast Soft Recovery
Rectifier Diode, 40 A
Vishay High Power Products
Base
common
cathode
2
FEATURES/DESCRIPTION
The 40EPF.. fast soft recovery rectifier series has been optimized for combined short reverse recovery time and low
forward voltage drop.
The glass passivation ensures stable reliable operation in the most severe temperature and power cycling conditions.
TO-247AC modified
PRODUCT SUMMARY
VF at 20 A < 1.25 V
t
rr
V
RRM
13
Cathode Anode
95 ns
1000/1200 V
This product series has been designed and qualified for industrial level.
APPLICATIONS
• Output rectification and freewheeling in inverters, choppers and converters
• Input rectifications where severe restrictions on conducted EMI should be met
MAJOR RATINGS AND CHARACTERISTICS
SYMBOL CHARACTERISTICS VALUES UNITS
V
RRM
I
F(AV)
I
FSM
t
rr
V
F
T
J
Sinusoidal waveform 40
1 A, 100 A/µs 95 ns
20 A, TJ = 25 °C 1.25 V
1000/1200 V
475
- 40 to 150 °C
A
VOLTAGE RATINGS
, MAXIMUM PEAK
V
RRM
PART NUMBER
40EPF10 1000 1100
40EPF12 1200 1300
REVERSE VOLTAGE
V
V
, MAXIMUM NON-REPETITIVE
RSM
PEAK REVERSE VOLTAGE
V
I
RRM
AT 150 °C
mA
10
ABSOLUTE MAXIMUM RATINGS
PARAMETER SYMBOL TEST CONDITIONS VALUES UNITS
Maximum average forward current I
Maximum peak one cycle non-repetitive surge current
Maximum I
Maximum I
Document Number: 93149 For technical questions, contact: diodes-tech@vishay.com Revision: 13-Jun-08 1
t for fusing I2t
t for fusing I2√t t = 0.1 to 10 ms, no voltage reapplied 11 310 A2√s
F(AV)
I
FSM
TC = 105 °C, 180° conduction half sine wave 40
10 ms sine pulse, rated V
10 ms sine pulse, no voltage reapplied 475
10 ms sine pulse, rated V
10 ms sine pulse, no voltage reapplied 1131
applied 400
RRM
applied 800
RRM
A
A
s
www.vishay.com
40EPF.. Soft Recovery Series
Vishay High Power Products
Fast Soft Recovery
Rectifier Diode, 40 A
ELECTRICAL SPECIFICATIONS
PARAMETER SYMBOL TEST CONDITIONS VALUES UNITS
Maximum forward voltage drop V
Forward slope resistance r
Threshold voltage V
Maximum reverse leakage current I
FM
t
F(TO)
RM
RECOVERY CHARACTERISTICS
PARAMETER SYMBOL TEST CONDITIONS VALUES UNITS
Reverse recovery time t
Reverse recovery current I
Reverse recovery charge Q
rr
rr
rr
Snap factor S 0.5
THERMAL - MECHANICAL SPECIFICATIONS
PARAMETER SYMBOL TEST CONDITIONS VALUES UNITS
Maximum junction and storage temperature range
Maximum thermal resistance, junction to case
Maximum thermal resistance, junction to ambient
Typical thermal resistance, case to heatsink
Approximate weight
Mounting torque
minimum 6 (5)
maximum 12 (10)
Marking device Case style TO-247AC modified (JEDEC)
T
, T
J
R
thJC
R
thJA
R
thCS
40 A, TJ = 25 °C 1.4 V
6.82 mΩ
0.94 V
0.1
- 40 to 150 °C
Stg
TJ = 125 °C
TJ = 25 °C
T
= 150 °C 10
J
IF at 10 Apk
25 A/µs 25 °C
V
= Rated V
R
RRM
450 ns
6A
1.8 µC
DC operation 0.6
40
Mounting surface, smooth and greased 0.2
6g
0.21 oz.
I
FM
dir
dt
40EPF10
40EPF12
t
rr
kgf · cm
(Ibf · in)
mA
I
RM(REC)
°C/W
t
Q
rr
www.vishay.com For technical questions, contact: diodes-tech@vishay.com
Document Number: 93149
2 Revision: 13-Jun-08
40EPF.. Soft Recovery Series
150
140
130
120
110
100
90
Temperature (°C)
80
Maximum Allowable Case
70
Conduction angle
60
0
150
140
130
120
110
100
90
Temperature (°C)
80
Maximum Allowable Case
70
60
0
Fast Soft Recovery
Rectifier Diode, 40 A
40EPF.. Series
(DC) = 0.6 °C/W
R
thJC
30°
Ø
10520
Average Forward Current (A)
Fig. 1 - Current Rating Characteristics
30°
10 20 40 50 60 70
Average Forward Current (A)
Fig. 2 - Current Rating Characteristics
15
60°
60°
90°
25 30 35 40 45
40EPF.. Series
(DC) = 0.6 °C/W
R
thJC
Conduction period
90°
180°
120°
30
180°
120°
Ø
DC
Vishay High Power Products
90
80
70
60
50
40
30
Power Loss (W)
20
Maximum Average Forward
10
0
450
400
350
300
250
200
Forward Current (A)
Peak Half Sine Wave
150
100
DC 180° 120°
90°
60°
30°
RMS limit
Conduction period
0 20304050607010
Average Forward Current (A)
Fig. 4 - Forward Power Loss Characteristics
At any rated load condition and with rated V
40EPF.. Series
1 10 100
applied following surge.
RRM
Initial TJ = 150 °C at 60 Hz 0.0083 s at 50 Hz 0.0100 s
Number of Equal Amplitude Half Cycle
Current Pulses (N)
Fig. 5 - Maximum Non-Repetitive Surge Current
Ø
40EPF.. Series T
= 150 °C
J
70
60
50
40
30
Power Loss (W)
20
10
Maximum Average Forward
0
0
Fig. 3 - Forward Power Loss Characteristics
180° 120°
90° 60° 30°
RMS limit
Ø
Conduction angle
40EPF.. Series
= 150 °C
T
J
10 155
20
25 30 35 40 45
Average Forward Current (A)
500
450
400
350
300
250
200
Forward Current (A)
Peak Half Sine Wave
150
100
0.01 0.1 1
Maximum non-repetitive surge current versus pulse train duration.
Initial TJ = 150 °C No voltage reapplied Rated V
40EPF.. Series
Pulse Train Duration (s)
Fig. 6 - Maximum Non-Repetitive Surge Current
reapplied
RRM
Document Number: 93149 For technical questions, contact: diodes-tech@vishay.com
www.vishay.com
Revision: 13-Jun-08 3
40EPF.. Soft Recovery Series
Vishay High Power Products
Instantaneous Forward Current (A)
0.7
0.6
0.5
0.4
0.3
- Maximum Reverse
rr
t
0.2
Recovery Time (µs)
0.1
0
04080 120 160 200
IFM = 10 A
dI/dt - Rate of Fall of Forward Current (A/µs)
Fig. 8 - Recovery Time Characteristics, T
40EPF.. Series T
J
IFM = 5 A
= 25 °C
IFM = 40 A
Fast Soft Recovery
Rectifier Diode, 40 A
1000
100
TJ = 25 °C
= 150 °C
T
10
1
01234 6
Instantaneous Forward Voltage (V)
Fig. 7 - Forward Voltage Drop Characteristics
IFM = 30 A
IFM = 1 A
= 25 °C
J
J
40EPF.. Series
- Maximum Reverse
rr
Q
5
6
5
4
3
2
Recovery Charge (µC)
1
0
0 40 80 120 160 200
dI/dt - Rate of Fall of Forward Current (A/µs)
Fig. 10 - Recovery Charge Characteristics, T
40EPF.. Series
= 25 °C
T
J
IFM = 40 A
IFM = 30 A
IFM = 10 A
IFM = 5 A
IFM = 1 A
= 25 °C
J
2.0
- Maximum Reverse
rr
t
1.6
1.2
0.8
Recovery Time (µs)
0.4
0
0 40 80 120 160 200
IFM = 60 A
= 40 A
I
FM
= 20 A
I
FM
= 10 A
I
FM
= 5 A
I
FM
= 1 A
I
FM
dI/dt - Rate of Fall of Forward Current (A/µs)
Fig. 9 - Recovery Time Characteristics, T
40EPF.. Series
= 150 °C
T
J
= 150 °C
J
20
40EPF.. Series
= 150 °C
T
J
16
12
8
- Maximum Reverse
rr
Recovery Charge (µC)
4
Q
0
04080 120 160 200
dI/dt - Rate of Fall of Forward Current (A/µs)
Fig. 11 - Recovery Charge Characteristics, T
IFM = 60 A
IFM = 40 A
IFM = 20 A
IFM = 10 A
IFM = 5 A
IFM = 1 A
= 150 °C
J
www.vishay.com For technical questions, contact: diodes-tech@vishay.com
Document Number: 93149
4 Revision: 13-Jun-08
40EPF.. Soft Recovery Series
Fast Soft Recovery
Vishay High Power Products
Rectifier Diode, 40 A
30
25
20
15
10
- Maximum Reverse Recovery Current (A)
rr
I
5
0
40EPF.. Series
= 25 °C
T
J
04080 120 160 200
IFM = 40 A
IFM = 30 A
IFM = 10 A
IFM = 5 A
IFM = 1 A
dI/dt - Rate of Fall of Forward Current (A/µs)
Fig. 12 - Recovery Current Characteristics, TJ = 25 °C Fig. 13 - Recovery Current Characteristics, TJ = 150 °C
1
50
40
30
20
- Maximum Reverse Recovery Current (A)
rr
10
I
0
40EPF.. Series
= 150 °C
T
J
040
80 120 160 200
IFM = 60 A
IFM = 40 A
IFM = 20 A
IFM = 10 A
IFM = 5 A
IFM = 1 A
dI/dt - Rate of Fall of Forward Current (A/µs)
Steady state value
(DC operation)
Single pulse
0.1
- Transient Thermal Impedance (°C/W)
thJC
Z
Fig. 14 - Thermal Impedance Z
D = 0.50 D = 0.33 D = 0.25 D = 0.17 D = 0.08
Square Wave Pulse Duration (s)
Characteristics
thJC
40EPF.. Series
100.0001 0.001 0.01 0.1 1
Document Number: 93149 For technical questions, contact: diodes-tech@vishay.com
www.vishay.com
Revision: 13-Jun-08 5
40EPF.. Soft Recovery Series
Vishay High Power Products
ORDERING INFORMATION TABLE
Device code
40 E P F 12 -
1
2
3
4 - Type of silicon:
5
6
Fast Soft Recovery
Rectifier Diode, 40 A
51324
- Current rating (40 = 40 A)
- Circuit configuration:
E = Single diode
- Package:
P = TO-247AC modified
F = Fast recovery
- Voltage code x 100 = V
- None = Standard production
PbF = Lead (Pb)-free
RRM
6
10 = 1000 V 12 = 1200 V
LINKS TO RELATED DOCUMENTS
Dimensions http://www.vishay.com/doc?95223
Part marking information http://www.vishay.com/doc?95226
www.vishay.com For technical questions, contact: diodes-tech@vishay.com 6 Revision: 13-Jun-08
Document Number: 93149
Legal Disclaimer Notice
Vishay
Notice
The products described herein were acquired by Vishay Intertechnology, Inc., as part of its acquisition of International Rectifier’s Power Control Systems (PCS) business, which closed in April 2007. Specifications of the products displayed herein are pending review by Vishay and are subject to the terms and conditions shown below.
Specifications of the products displayed herein are subject to change without notice. Vishay Intertechnology, Inc., or anyone on its behalf, assumes no responsibility or liability for any errors or inaccuracies.
Information contained herein is intended to provide a product description only. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Vishay's terms and conditions of sale for such products, Vishay assumes no liability whatsoever, and disclaims any express or implied warranty, relating to sale and/or use of Vishay products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright, or other intellectual property right.
The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications. Customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Vishay for any damages resulting from such improper use or sale.
International Rectifier are registered trademarks of International Rectifier Corporation in the U.S. and other countries. All other product names noted herein may be trademarks of their respective owners.
®
, IR®, the IR logo, HEXFET®, HEXSense®, HEXDIP®, DOL®, INTERO®, and POWIRTRAIN
®
Document Number: 99901 www.vishay.com Revision: 12-Mar-07 1
Loading...