The 12CWQ03FN surface mount, center tap, Schottky rectifier
series has been designed for applications requiring low forward
drop and small foot prints on PC board. Typical applications are
in disk drives, switching power supplies, converters, freewheeling diodes, battery charging, and reverse battery
protection.
Popular D-PAK outline
Center tap configuration
Small foot print, surface mountable
Low forward voltage drop
High frequency operation
Guard ring for enhanced ruggedness and long term reliability
1.14 (0.04)
0.89 (0.03)
0.58 (0.02)
0.46 (0.02)
6.45 (0.24)
5.68 (0.22)
0.51 (0.02)
MIN.
0.58 (0.02)
0.46 (0.02)
MINIMUM RECOMMENDED FOOTPRINT
5.97 (0.24)
6.48 (0.26)
2x
2.54 (0.10)
1.65 (0.06)
2x
10.67 (0.42)
2.28 (0.09)
2x
Conform to JEDEC outline D-Pak (Similar to TO-252AA)
Dimensions in millimeters and (inches)
www.irf.com1
12CWQ03FN
Bulletin PD-20558 rev. E 01/03
Voltage Ratings
Part number12CWQ03FN
VRMax. DC Reverse Voltage (V)
V
Max. Working Peak Reverse Voltage (V)
RWM
30
Absolute Maximum Ratings
Parameters12CWQ... UnitsConditions
I
Max. Average Forward (Per Leg)6A50% duty cycle @ TC = 135°C, rectangular wave form
F(AV)
Current * See Fig. 5 (Per Device)12
I
Max. Peak One Cycle Non-Repetitive3205µs Sine or 3µs Rect. pulse
FSM
Surge Current (Per Leg) * See Fig. 713010ms Sine or 6ms Rect. pulse
EASNon-Rep. Avalanche Energy (Per Leg)10mJT
A
= 25 °C, I
J
= 2.0 Amps, L = 5 mH
AS
IARRepetitive Avalanche Current2.0ACurrent decaying linearly to zero in 1 µsec
(Per Leg)Frequency limited by TJ max. VA = 1.5 x VR typical
Following any rated
load condition and with
rated V
RRM
applied
Electrical Specifications
Parameters12CWQ... UnitsConditions
VFMMax. Forward Voltage Drop0.47V@ 6A
(Per Leg) * See Fig. 1(1)0.55V@ 12A
0.37V@ 6A
0.49V@ 12A
IRMMax. Reverse Leakage Current3mA TJ = 25 °C
(Per Leg) * See Fig. 2(1)58mA TJ = 125 °C
V
Threshold Voltage0.196VT
F(TO)
= TJ max.
J
rtForward Slope Resistance21.66mΩ
CTTyp. Junction Capacitance (Per Leg)590pFVR = 5VDC, (test signal range 100Khz to 1Mhz) 25°C
LSTypical Series Inductance (Per Leg)5.0nHMeasured lead to lead 5mm from package body
(1) Pulse Width < 300µs, Duty Cycle <2%
TJ = 25 °C
TJ = 125 °C
VR = rated V
R
Thermal-Mechanical Specifications
Parameters12CWQ... UnitsConditions
TJMax. Junction Temperature Range (*) - 55 to 150°C
T
Max. Storage Temperature Range- 55 to 150°C
stg
R
Max. Thermal Resistance (Per Leg)3.0°C/W DC operation* See Fig. 4
thJC
Junction to Case(Per Device)1.5
wtApproximate Weight0.3 (0.01) g (oz.)
Case StyleD-PakSimilar to TO-252AA
(*) dPtot1
< thermal runaway condition for a diode on its own heatsink
dTj Rth( j-a)
2
www.irf.com
12CWQ03FN
Bulletin PD-20558 rev. E 01/03
100
1000
T = 150°C
100
R
J
10
125°C
100°C
1
0.1
F
10
Reverse Current - I (mA)
0.01
0.001
051015202530
Fig. 2 - Typical Values Of Reverse Current
75°C
50°C
25°C
Reverse Voltage - V (V)
R
Vs. Reverse Voltage (Per Leg)
1000
Instantaneous Forward Current - I (A)
T = 150°C
J
T = 125°C
J
T = 25°C
J
T
T = 25°C
J
1
00.2 0.4 0.6 0.811.2 1.4 1.6 1.8
Fig. 1 - Max. Forward Voltage Drop Characteristics
www.irf.com
Junction Capacitance - C (pF)
100
05101520253035
Forward Voltage Drop - V (V)
FM
Reverse Voltage - V (V)
Fig. 3 - Typical Junction Capacitance
(Per Leg)
Vs. Reverse Voltage (Per Leg)
10
D = 0.75
D = 0.50
D = 0.33
1
thJC
Thermal Impedance Z (°C/W)
D = 0.25
D = 0.20
0.1
Single Pulse
(Thermal Resista nce)
Notes:
1. Duty factor D = t / t
2. Peak T = P x Z + T
0.01
0.000010.00010.0010.010.11
t , Rectangular Pulse Duration (Seconds)
Fig. 4 - Max. Thermal Impedance Z
1
Characteristics (Per Leg)
thJC
P
DM
t
1
t
2
1
J
DM
thJC
R
2
C
3
12CWQ03FN
Bulletin PD-20558 rev. E 01/03
150
145
140
135
Square wave (D = 0.50)
80% Rated V applied
130
R
125
Allowable Case Temperature - (°C)
see note (2)
120
0123456789
Average Forward Current - I (A)
Fig. 5 - Max. Allowable Case Temperature
Vs. Average Forward Current (Per Leg)
1000
FSM
DC
F(AV)
At Any Rated Load Condition
And With Rated V Applied
Following Surge
RRM
4
3.5
2.5
D = 0.20
D = 0.25
D = 0.33
3
D = 0.50
D = 0.75
RMS Limit
2
1.5
1
Average Power Loss - (Watts)
0.5
0
0123456789
Average Forward Current - I (A)
Fig. 6 - Forward Power Loss Characteristics
(Per Leg)
DC
F(AV)
(2) Formula used: TC = TJ - (Pd + Pd
Pd = Forward Power Loss = I
Pd
= Inverse Power Loss = VR1 x IR (1 - D); IR @ V
REV
4
Non-Repetitive Surge Current - I (A)
100
10100100010000
Square Wave Pulse Duration - t (microsec)
p
Fig. 7 - Max. Non-Repetitive Surge Current (Per Leg)
) x R
thJC
;
F(AV)
/ D) (see Fig. 6);
= 80% rated V
R1
R
F(AV)
REV
x VFM @ (I
www.irf.com
Marking Information
EXAMPLE: THIS IS AN 12CWQ03FN
Tape & Reel Information
TR
FEED DIRECTION
4.1 (0.16)
3.9 (0.15)
2.1 (0.83)
1.9 (0.07)
12.1 (0.48)
11.9 (0.47)
INTERNATIONAL
RECTIFIER LOGO
ASSEMBLY
LOT CODE
1.85 (0.07)
1.65 (0.06)
1.85 (0.07)
1.65 (0.06)
DIA.
2.6 (0.10)
1.5 (0.06)
7.6 (0.30)
7.4 (0.29)
DIA.
4 (K)
12CWQ03FN
712A
5K3A
2 (K)
1 (A) 3 (A)
0.35 (0.01)
0.25 (0.01)
7.0 (0.28)
6.8 (0.26)
2.75 (0.11)
2.55 (0.10)
12CWQ03FN
Bulletin PD-20558 rev. E 01/03
PART NUMBER
DATE CODE (YWWA)
Y= YEAR
WW = WEEK
A= LINE
16.3 (0.64)
15.7 (0.62)
375 (14.17)
DIA. MAX.
TRR
FEED DIRECTION
TRL
FEED DIRECTION
13 (0.52) DIA.
4.1 (0.16)
3.9 (0.15)
2.1 (0.83)
1.9 (0.07)
8.1 (0.32)
7.9 (0.31)
4.1 (0.16)
3.9 (0.15)
2.1 (0.83)
1.9 (0.07)
8.1 (0.32)
7.9 (0.31)
1.85 (0.07)
1.65 (0.06)
1.85 (0.07)
1.65 (0.06)
7.6 (0.30)
7.4 (0.29)
2.6 (0.10)
1.5 (0.06)
1.85 (0.07)
1.65 (0.06)
1.85 (0.07)
1.65 (0.06)
7.6 (0.30)
7.4 (0.29)
2.6 (0.10)
1.5 (0.06)
22.4 (0.88)
50 (1.97) DIA.
DIA.
DIA.
0.35 (0.01)
0.25 (0.01)
10.6 (0.42)
10.4 (0.41)
DIA.
DIA.
2.75 (0.11)
2.55 (0.10)
0.35 (0.01)
0.25 (0.01)
10.6 (0.42)
10.4 (0.41)
2.75 (0.11)
2.55 (0.10)
TO-252AA Tape & Reel
When ordering, indicate the part
number, part orientation, and the
quantity. Quantities are in multiples
of 2,000 pieces per reel for TR and
multiples of 3,000 pieces per reel
for both TRL and TRR.
16.3 (0.64)
15.7 (0.62)
16.3 (0.64)
15.7 (0.62)
www.irf.com
5
12CWQ03FN
Bulletin PD-20558 rev. E 01/03
This product has been designed and qualified for Industrial Level.
IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105
6
Data and specifications subject to change without notice.
Qualification Standards can be found on IR's Web site.
TAC Fax: (310) 252-7309
Visit us at www.irf.com for sales contact information. 01/03
www.irf.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.