VisAccess AXS-10 Installation Manual

Page 1 of 8 DE6270_V10
AXS-10
VisAccess
Installation Guide
1. Introduction
The Visonic Technologies AXS-10 is an electronic access control system designed for a single access point, such as a main door in an apartment building or individual office doors. The system control unit relay activates a lock or electromagnetic strike (EMS), when a valid proximity key (tag or card) is presented to the reader located outside the protected area.
The use of a proximity (non-contact) key makes the installation of the AXS-10 system an attractive possibility in harsh environments and in places with poor lighting conditions. The proximity keys are totally sealed and are wear resistant. The reader reads the key’s ID, whenever the key is presented.
A second proximity reader may be connected to the AXS-10 to control both sides of a door. An optional magnetic stripe card reader may be connected instead of a proximity reader.
The separate weatherproof readers provide added security and flexibility allowing outdoor or indoor installation.
The AXS-10 control unit (see figure 1) includes a 3-digit display, 3 visual indicators (LEDs) and 4 buttons. An internal proximity reader located in the upper right corner of the control panel allows fast and easy programming of access keys. The buttons are used for entering the password and for programming the unit.
AXS-10 controllers can be networked (see par. 4.5.).
Figure 1 - System Functional Presentation
RDR-3
Proximity
Reader
CRD-1
Prox. Card
TAG-1
Prox. Tag
CRD-1M Magnetic
Stripe Card
AXS-10 Control Unit
RDC-3
Magnetic
Stripe
Reader
RDC-3MP
Magnetic
Stripe
Reader
Figure 2 - System Components
The AXS-10 has a memory capacity of 300 keys. Adding keys simply involves presenting new keys to the controller while the system is in ADD mode.
The user can delete keys in the DELETE mode by presenting them to the reader or, if a tag/card is not available, by typing in its number (the same one that appears when adding the key).
When the system is in TOGGLE mode, presenting a valid tag arms/disarms an alarm system or activates/deactivates an electrical device (such as an air conditioner).
The AXS-10 kit includes:
AXS-10 controller
RDR-3 proximity reader with 1m (3 ft) 5-wire cable
Installation instructions
User guide
Control unit base template, for wall installation
Additional tools and equipment that may be needed:
Proximity tags or cards (ordered separately)
Power supply for the controller - 12V AC/DC
Electromagnetic strike (EMS) unit
RTE (request-to-exit) push button or PIR, if required.
2. Specifications
AXS-10 CONTROLLER
Power Input: 9-12V AC/DC Max Current Consumption: 150 mA (excluding EMS current) Memory Capacity: 300 tags/cards Output Relay Contact Rating: 1A max.; continuous current Display: 3 x 7 segments and 3 LEDs Operating Temperatures: 0°C to 50°C (32°F to 122°F) Dimensions (L x W x D): 150 x 105 x 35 mm (5-7/8 x 4-1/8 x 1-3/8 in.) Color: Dark gray Weight: 250g
RDR-3 EXTERNAL PROXIMITY READER
Indicators: Tricolor LED (Green, Red, Amber) Tag Reading Range: 50-100 mm (2-4 in.) Frequency: 125 kHz Tag Code Possibilities: 10
12
possible combinations
Dimensions (L x W x D): 116 x 70 x 16.8 mm (4-1/2 x 2-3/4 x 5/8 in.) Weight: 121.5 g (4.3 oz) Operating Temperatures: -20°C to 50°C (-4°F to 122°F) Max. Distance form Controller: 10 meters/ 32.8 Feet Color: Metallic brown RDC-3 MAGNETIC STRIPE READER (optional) Designed for: Indoor installation only Card Standard: ISO 7811 Track Number: 2 (IATA) Reading Method: 210BPI Card Thickness: 0.76 ± 0.08 mm Power Supply: 5V DC ± 5% Output Level: High - 2.4V min, low - 0.8V max
Current Consumption: Less than 10 mA Card Feeding Speed: 15 - 120 cm/sec Minimum Head Life: 300,000 card passes Length of Supplied Cable: 1 m (3 ft) Dimensions (LxWxD): 99x31x32mm (3-7/8 x 1-3/16 x 1-1/4 in) Weight: 45 g (1.6 oz) approximately Operating Temperature: 0 - 50°C (32 - 122°F) Color: Dark brown
RDC-3MP MAGNETIC STRIPE READER (optional)
Designed for: Indoor and outdoor installations Vandal Resistance: Stainless steel Protocol: AB (TTL + LED) Power Supply: 4.5 - 5.5 VDC Current: Less than 35mA Output Type: Open-collector (pulled up internally with 4700Ω res.) Card Material: Plastic Card Thickness: 0.762 +/- 0.07 mm Operating Temperature Range: 0 to 50°C (32 to 122°F) Storage Temperature Range: -20 to +70°C (-4 to 158°F) Data Tracks: Track 1, 2 (or 3, in high or low coercivity)
Humidity: 5 to 95% LED Colors: Red/Green Length of Supplied Cable: 1.5 m (16 ft) Cable Type: 10 core screened. Dimensions (L x W x D): 104 x 49.5 x 35 mm
(4-1/8 x 1-15/16 x 1-3/8 in) Weight: 380 g approx. (13.4 oz)
AXS-10 Single-Door Access Control System – Installation Guide
Page 2 of 8 DE6270_V10
3. Installation
3.1 Controller Unit Installation
Figure 3 - Control Unit Installation
3.2 Proximity Reader Installation
Caution: Do not install the RDR-3 on a metal surface or on a metal door frame, since this decreases the key reading range significantly. If you have to install the reader on a metal surface, use a spacer plate so that the reader will be at least 1 cm (3/8 in.) away from the metal. You may use RDR-BACK which is an optional spacer plate made specifically for this purpose.
When installing two readers, you may install them in close proximity to each other.
Figure 4 - Proximity Reader Installation
3.3 Setting DIP Switch
Figure 5 - DIP Switch Setting
4. Wiring
4.1 Electromagnetic Strike Wiring
Electro-Magnetic Locks Powered by AXS-10
A. Connecting Electro-magnetic
lock that opens the door when power is supplied
B. Connecting Electro-magnetic
lock that opens the door when power is disconnected
Electro-Magnetic Locks Powered by an External Power Supply
C. Connecting Electro-magnetic
lock that opens the door when power is supplied
D. Connecting Electro-magnetic
lock that opens the door when power is disconnected
AXS-10 Single-Door Access Control System – Installation Guide
Page 3 of 8 DE6270_V10
4.2 RTE and Door Position Wiring
Figure 6 - Connecting RTE and Door Position Inputs
4.3 Proximity Readers Wiring
Figure 7 - Connecting One Proximity Reader
Figure 8 - Connecting Two Proximity Readers
Figure 9 - DIP Switch Setting for Proximity or Magnetic Reader
4.4 Magnetic Stripe Readers Wiring
Figure 10 - Magnetic Stripe Reader RDC-3 Wiring
Figure 11 - Magnetic Stripe Reader RDC-3MP Wiring
* Reader 1 "Data In" terminal, for RDC-3 and RDC-3MP, is used for clock signal.
Figure 12 - Magnetic Stripe Reader RDC-3MP Wiring
Loading...
+ 5 hidden pages