Notice to Users:
The User’s Manual is a part of the
electrostatic sprayer. Please keep it in good
condition. To use and maintain the product
in good working condition, please read the
User’s Manual carefully before operation. If
you have any doubt, contact the supplier.
PACK LIST:
● Reservoir backpack with 2-filters and lid
● Shoulder straps
● Lithium battery charger
● Wand
● Blower
● Tri-tip nozzle for blower
● Cone nozzle for wand
● Double-tipped nozzle for wand
● Blue nozzle for wand
● Additional O washers
● User manual
The electrostatic sprayer shall be operated,
maintained, and repaired by persons
familiar with its performance, and know how
to operate it safely. The manufacturer shall
not be liable for decreased reliability,
machine damage, or personal injury arising
from unauthorized modifications to the
electrostatic sprayer.
ASSEMBLY:
1.
2.

OPERATION:
1. Plug lithium battery charger into charging port and
charge until red light turns green.
2. Attach either Blower or Wand to the Hose.
3. Pour disinfectant into Reservoir and secure Lid.
4. Place backpack on back using Shoulder Straps.
5. Turn on Power with left hand.
6. Disinfect desired surfaces.
7. When finished, pour any remaining disinfectant out
of reservoir.
8. Pour in some water to rinse through Blower/Wand
for a minimum of 15-seconds to clean out any
disinfectant.
9. Pour out any unused rinse water.
10. Return to storage location and plug lithium battery
charger into charging port.
SPRAYING METHOD:
● Do not walk into the chemicals as you are spraying.
The height of the nozzle depends on how much
you want to apply.
● Typically, keeping the Blower with fan off 3-feet
away from the objects provides adequate
coverage, but your application may require
adjustments.
● When using the Blower with the fan off, the range is
approximately 4~6 feet. With the fan on, the range
is up to 18 feet.
3. 4.

WARNING:
If the liquid spills from the mouth of the reservoir and
soaks the reservoir’s exterior, and the operator’s clothing
and body, it is susceptible to electrostatic leaks that irritate
the skin. Therefore, it is essential to tighten the lid of the
reservoir after filling and prevent spillage from the mouth
of the reservoir during operation. Keeping the exterior of
the reservoir dry and clean is vital to ensure the
electrostatic absorption and comfortable handling of the
sprayer.
I) Safety and Operational Considerations
● Attention must be paid to the filtration of liquid and
water to avoid clogging the nozzle and affecting
operation. If the nozzle is blocked, the particles
must be removed before starting the machine
operation.
● Operators must be aware of the properties and
protective methods used to avoid direct physical
contact with chemicals. Spraying with chemicals
that have a corrosive effect on plastics and metals
should be avoided. Do not spray with wettable
powder to prevent clogging the nozzle.
● After the electrostatic sprayer has been used, the
interior of the drum and the injection system shall
be cleaned and wiped down with water promptly
before being placed in an appropriate storage
location. Cleaning method: fill the reservoir with
water and spray the machine for 15-seconds, pour
out the remaining water and wipe clean.
● Do not submerge the pump or battery in water. Do
not use the electrostatic sprayer in a flammable or
explosive environment.
● Care should be taken to keep the exterior of the
reservoir and the wand in a clean and dry condition
during operation and prohibit physical contact with
passers-by during the process. Do not touch the
spray rod or the charging socket with your hand
during operation.
● After operating, the handle switch should be
turned off, then turn off the electrostatic/pump
switch on the reservoir.
● After charging, leave it for 10-minutes before using.
The battery should be charged for maintenance at
least once-a-month. Proper use and maintenance
of the battery can significantly extend the life of the
battery.
● The machine is equipped with tens of thousands of
high-voltage electricity and disassembly of the
machine is strictly prohibited.
● The use of special working fluids, such as strong
acids and bases, is not permitted.
● Chemicals should be used following the safety
instructions provided by the manufacturer.
5.
6.

Working Principles
● The sprayer uses a 12V lithium battery as the
power source to drive the water pump and
high-voltage electrostatic generator at the same
time. When the high-speed pump squeezes out the
electrostatic charge from the tiny nozzle, the tiny
droplets are sprayed under the combined action of
gravity, external force, and electrostatic force
directly to the target.
Scope of Applications
● This machine can be used for sanitary epidemic
prevention and disinfection of factories,
warehouses, schools, airports, hospitals, retail
locations, and more.
Specifications
● Empty weight: 9.0 lbs
● Size: 14.5 x 7.5 x 21.5
● Reservoir Capacity: 16-liters (4.2 gallons)
● Battery capacity: 12V, 10aH Lithium
● Charger Input: AC 110
● Continuous working time: 4~6 hours
● Electrostatic voltage output: 1.5 - 3 kV
● Pressure: 0.15 - 0.4 mpa
● Median droplet diameter: 80 microns (40~120)
● Flow Rate (blower w/o fan): 1-gallon per hour
● Spray distance (blower w/o fan): 3~6 feet
● Spray distance (blower w/ fan): ≤ 18 feet
● Flow Rate (cone nozzle): 1.5-gallons per hour
● Spray distance (cone nozzle): 3~6 feet
7.
After-Sales Service
● This machine has been strictly inspected and
passed factory quality-control. If the new device is
unable to operate as designed, please contact your
supplier.
Warranty Coverage
● One-year warranty for the whole machine and
one-year for major parts, except for normal
wear-and-tear. The main components include the
battery, charger, high-voltage generator, and water
pump. One-month warranty on all wear parts. Wear
parts include seals, nozzles, lids, etc.
● The battery IS NOT covered under warranty if it is
over-discharged, or improper charging
maintenance causes a shortened battery life.
Additionally, the battery IS NOT covered under
warranty if there is an electrical surge while
charging the battery.
● The pump IS NOT covered under warranty due to
external forces, corrosive liquid immersion, or
chemical impurities.
● If repairs are required, please contact your supplier.
● In the event of human-caused damage during the
warranty period, warranty personnel may charge
for the cost of repair.
8.