ESD SAFE:
GROUNDED THROUGH THREE WIRE CORD ELECTRICALLY CONDUCTIVE VACUUM CUPS STATIC DISSAPATIVE RUBBER HOSE STATIC DISSAPATIVE PLASTIC NOZZLE
VACUUM:
MINIMUM 5 INCHES OF MERCURY AT SEA LEVEL.
DIMENSIONS:
LENGTH HEIGHT WIDTH 8” (203.2mm) 2.8” (70.6mm) 3.6” (91.44mm)
WEIGHT:
2.721 LBS.
POWER REQUIREMENTS:
MODEL # V8400 110 VOLTS A.C. 60 HERTZ 8 WATTS MODEL # V8400-220 220 VOLTS A.C. 50 HERTZ 8 WATTS
SMD-VAC™-HF OPTIONS
UUM INTERRUPTER P/N V3025
VAC Facilitates precision placement of small parts. The hand that holds the wand is used to position and/or rotate the part being placed while the other hand makes or breaks the vacuum.
SELECTION OF VACUUM CUPS WITH PROBES The vacuum cups are a soft rubber material that allow handling a wide variety of small parts.
SELECTION OF MINIATURE VACUUM TIPS These tips are designed to handle
tiny parts as small as 0.01” (0.25mm).
SMD-VAC™-HF
ESD Safe Vacuum Handling Tool
Model No. V8400 Model No. V8400-220
OPTIONAL SIDE MOUNTED VACUUM PEN HOLDER Mounts on side of SMD-VAC unit for vacuum pen storage.
Virtual Industries, Inc. 2130 Victor Place Colorado Springs, CO 80915 U.S.A.
For technical assistance call toll free 1-800-590-2829 Tele: 719-572-5566 Fax: 719-572-5504 8:00 A.M. to 4:30 P.M. Mountain Standard Time
9/26/08
Operation of the SMD-VAC™-HF
Using the optional Interrupter P/N V3025
1. Connect the small diameter vacuum hose to the vacuum fitting on the front of the SMD­VAC. Make sure the hose is pushed all of the way on. Connect the other end of the vacuum hose to the rear of the vacuum handle, again make sure the hoses pushed all the way on.
2. Select a probe with a vacuum cup that is slightly smaller in diameter to the outline of the parts that you want to pick and place. Securely install
it o the tapered end of the vacuum handle. Selecting a vacuum cup that is too large or too small will result in improper operation.
3. Connect the 3 wire SMD-VAC power cord to input power. Turn the ON/OFF switch to the on position.
4. To pick and place a part:
PRECISION PARTS PLACEMENT
1. Connect the small diameter vacuum hose to the vacuum fitting on the front of the SMD-VAC. Make sure the hose is pushed all the way on. Connect the other end of the vacuum hose to one side of the vacuum interrupter block. Connect another length of vacuum hose in between the other side of the vacuum interrupter block and the
V3021-RF or optional V3121-
rear of the vacuum handle that has NO control hole
(
RF), again make sure the hose is pushed all the way on.
VACUUM FITTING FOR HOSE
2. Select a probe with a vacuum cup that is slightly smaller in diameter to the outline of the parts that you want to pick and place. Securely install it on the tapered end of the vacuum handle. Selecting a vacuum cup that is too large or too small will result in improper operation.
ord to input power. Turn the ON/OFF switch to
3. Connect the 3 wire SMD-VAC powe
r c
the on position.
4. To pick and place a part:
a. Gently place the vacuum cup on top of the part that you wish to pick up. The part
n
ON/OFF SWITCH
should now be firmly grasped by the vacuum cup.
b. Now move the part to where you want it.
c. To release the part simply depress the button on the interrupter block with your finger,
the part should now be released.
o turn the unit off when you are finished.
5. Reme
VACUUM INTERRUPTER BUTTON
mber t
VACUUM HANDLE
a. Gently place the
vacuum cup on top of the part that you wish to pick up. The part should now be firmly grasped by the vacuum cup.
o w
b. Now move the part t
here you want it.
c. To release the part simply depress the button with your finger, the part should now be
released.
5. Remember to turn the unit off when you are finished.
PROBE WITH VACUUM CUP
VACUUM BUTTON
INTERRUPTER BLOCK
VACUUM HOSE