![](/html/9b/9bc5/9bc5f1e67d8e12e1ebe4f8e1e2622371ecea76c56e66fc07050f508f10237629/bg1.png)
To Order Parts Call 1-888-702-5326 - https://monsterfloorequipmentparts.com
3-SPEED AIR MOVER
OWNERS MANUAL
IMPORTANT: READ OWNERS MANUAL CAREFULLY
Please fi ll out and return your warranty card!
REN08007-VP 3-SPEED BLOWER
MODEL # RACER, TPRACER
Form No. 56091136 7/14 REV A
![](/html/9b/9bc5/9bc5f1e67d8e12e1ebe4f8e1e2622371ecea76c56e66fc07050f508f10237629/bg2.png)
To Order Parts Call 1-888-702-5326 - https://monsterfloorequipmentparts.com
INSTRUCTIONS FOR USEA - ENGLISH
TABLE OF CONTENTS
Page
Safety Precautions ....................................................................A-2
Machine Operation /Daisy Chain ...............................................A-3
Maintenance /Storage ...............................................................A-3
Parts List ..........................................................................D-2 – D-3
Wiring Diagram ......................................................................... D-3
SAFETY PRECAUTIONS
All operators shall read, understand and exercise the following safety precautions:
1) Do not operate machine:
• Unless trained and authorized.
• Unless you have read and understand the operators manual.
• Infl ammable or explosive areas.
• With a damaged cord or plug.
• If not in proper operating condition.
• In outdoor areas.
• In standing water.
• With the use of extension cords.
2) Before operating machine:
• Make sure all safety devices are in place and operate properly.
3) When using machine:
• Do not pull machine by cord or plug.
• Do not pull cord around sharp edges or corners.
• Do not unplug machine by pulling on the cord.
• Do not stretch cord.
• Do not handle plug with wet hands.
• Keep cord away from heated surfaces.
• Report machine damage or faulty operation immediately.
4) Before leaving or servicing machine:
• Turn off machine.
• Unplug cord from outlet.
5) When servicing machine:
• An experienced technician should only perform service work.
• Unplug cord from outlet.
• Use manufacturer supplied or approved replacement parts.
GROUNDING INSTRUCTIONS
General – This air mover shall be grounded while in use to
protect the operator from electrical shock. The machine is
provided with a three – conductor cord and a three – contact
grounding type attachment plug to fi t the proper grounding type
receptacle. The green (or green & yellow) conductor in the cord
is the grounding wire. Never connect this wire to anything other
than the grounding pin of the attachment plug.
This machine is for use on a nominal 120 – volt circuit and
has a grounding plug that resembles the plug illustrated in the
fi gure below. Make sure that the machine is connected to an
outlet having the same confi guration as the plug. No adapter
should be used with this machine.
This machine is intended for commercial use only. It is
constructed for use in an indoor environment and is not
intended for any other use.
Grounding Pin
Grounded Outlet Box
A - 2 3-Speed Air Mover - 56091136 7/2014
Metal Scr
Grounded Outlet
Adapt
![](/html/9b/9bc5/9bc5f1e67d8e12e1ebe4f8e1e2622371ecea76c56e66fc07050f508f10237629/bg3.png)
To Order Parts Call 1-888-702-5326 - https://monsterfloorequipmentparts.com
BASIC OPERATION
1) Check the machine for any obstructions in fan prior to operation.
• If an item blocks the intakes of the air mover, this will hurt the performance of the machine, and could cause the motor to overheat.
2) Adjust machine to desired position for operation by pulling it back to its preset height adjustments.
3) Plug power cord into a grounded outlet.
• Do not use an extension cord in conjunction with the standard power cord.
4) This machine has 3 power settings. Turn the power knob to the desired speed.
• Low = 1 Med = 2 High = 3.
5) To stop the machine at any time, simply turn the power knob to the “off” position.
• Never stick any object into the air inlet vents or the air outlet vent.
DAISY CHAIN
The 3-Speed Air Mover can be connected in a “Daisy Chain” allowing
for two (2) additional units to work together on one circuit.
• Only use 3-Speed Air Mover units together in the daisy
chain.
NOTE: The 3-Speed Air Mover has an onboard circuit breaker. If the
auxiliary outlet overloads, the circuit breaker will trip. If the breaker
trips, unplug the units and press the circuit breaker reset button. Plug
the units back into the power source and turn on the switch.
ENGLISH - AINSTRUCTIONS FOR USE
MAINTENANCE
To keep this machine performing well for many years, please follow the
following maintenance procedures:
Always confi rm the machine is unplugged from the power source
prior to performing any maintenance or repairs!
1) Unplug machine as soon as you are done using it.
2) Wrap the power cord around the carrying handle.
3) Check power cord for any damage. If any damage is detected,
replace the cord immediately.
4) Lubricate the handle assembly and wheels with a water resistant
lubricant every month.
5) Check machine for loose or missing nuts and bolts, and replace
as necessary.
6) Clean the outside of the machine with a mild cleaner.
AIR MOVER STORAGE
Air Movers can be stacked (up to 4) on their sides for storage.
NOTICE:
1) Stacking feature is not secure for transportation.
2) Remove the fi lters before stacking.
7/2014 A - 3 56091136 - 3-Speed Air Mover