Viper 350 Plus Owner's Manual

350Plus
Owner’s Guide
Contents
What is included ...................................................................................... 2
Standard transmitter configuration .............................................................. 2
Three-button transmitter configuration .................................................3
Important information ............................................................................... 4
Transmitter functions ................................................................................. 6
Using your system .................................................................................... 8
Nuisance Prevention Circuitry® ...................................................... 15
Diagnostics ........................................................................................... 17
Code hopping ....................................................................................... 20
High frequency ...................................................................................... 21
Owner Recognition ................................................................................ 21
Rapid resume logic ................................................................................. 22
Power saver mode.................................................................................. 22
Programming options ............................................................................. 23
Vehicle Recovery System (VRS) ................................................................. 27
Glossary of terms ................................................................................... 31
Security & convenience expansions .......................................................... 33
Quick reference guide ............................................................................ 35
Limited lifetime consumer warranty ........................................................... 36
© 2008 Directed Electronics - All rights reserved.
1
What is included
One control module•
A pair of four button transmitters, (p/n 7142V)•
A Stinger® Doubleguard® dual-stage shock sensor (on-board •
the control module)
Control Center with integrated status LED and valet override •
switch (p/n 6111T)
The Revenger® Soft Chirp® six-tone pro gram ma ble siren•
Your warranty registration•
Failsafe® Starter Kill ready circuitry (may require additional •
charges, ask your dealer for details.)
Standard transmitter configuration
controls the Arm function.
controls the Disarm function.
controls Silent Mode™ and an Auxiliary Output.
controls the Panic function.
and
2
pressed together control an Auxiliary Output.
© 2008 Directed Electronics- All rights reserved.
➢Three-button transmitter configuration*
controls the Arm/Disarm function.
controls the Panic function.
controls Silent Mode™ and an Auxiliary Output.
and
together control an Auxiliary Output.
*Optional three-button transmitter (not included).
© 2008 Directed Electronics - All rights reserved.
3
Important information
Congratulations on the purchase of your state-of-the-art vehicle se­cu ri ty system. This system has been designed to provide years of trouble-free op er a tion. Due to the complexity of this system, it must be installed by an authorized dealer only. Installation of this product by anyone other than an authorized dealer voids the war­ranty. All dealers are provided with preprinted dealer cer tifi cates to verify that they are au tho rized. This owner’s guide should help you to get the most out of your system. Please take the time to read it prior to using the system.
System maintenance
The system requires no specific maintenance. Your remote control is pow ered by 2 small, lightweight CR2016 batteries. When the batteries weakens, operating range will be reduced and the LED on the remote will dim.
4
© 2008 Directed Electronics- All rights reserved.
Your warranty
Your warranty registration must be returned and the bar code se­rial number must not be removed. If the warranty registration is not returned, you do not have a warranty. It is also necessary to keep your proof of purchase, which reflects that the product was installed by an au tho rized dealer. Make sure that you receive the warranty registration from your dealer.
FCC/ID notice
This device complies with Part 15 of FCC rules. Operation is subject to the following two con di tions: (1) This device may not cause harmful interference, and (2) This device must accept any in ter fer ence re ceived, including in ter fer ence that may cause unde­sired op er a tion. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to oper­ate this device.
© 2008 Directed Electronics - All rights reserved.
5
Transmitter functions
The system uses a computer-based learn routine to learn the trans­mit ter buttons. This makes it possible to assign any transmitter button to any system function. The transmitter initially comes programmed with Standard Configuration, but may also be customized by an authorized dealer. The buttons in all of the instructions in this man­ual correspond to a Standard Configuration transmitter.
Standard configuration
Button The arming function is controlled by pressing this button for one second.
Button The disarming function is controlled by pressing this button for one second.
Button Silent Mode™ and an optional auxiliary function are controlled by pressing this button. (Silent Mode works by pressing this button for less than one second before arming or disarming. An optional auxiliary function, such as trunk release, can be controlled by pressing this button for 1.5 seconds.) The auxiliary output controls __________________________.
6
© 2008 Directed Electronics- All rights reserved.
Button The panic feature is controlled by pressing this button for two seconds.
and
Buttons An optional auxiliary convenience or expansion function that you have added to your system can be activated by pressing these buttons simultaneously. The auxiliary output controls_________________________.
➢Three-button configuration
(Available with optional three-button transmitter.)
Button The arming and disarming functions are controlled by pressing this button for one second.
Button Silent Mode™ and an optional auxiliary function are controlled by pressing this button. (Silent Mode works by pressing this button for less than one second before arming or disarming. An optional auxiliary function, such as trunk release, can be controlled by pressing this button for 1.5 seconds.) The auxiliary output controls __________________________.
Button The panic feature is controlled by pressing this button for two seconds.
© 2008 Directed Electronics - All rights reserved.
7
Using your system
The buttons used in the instructions in this manual correspond to the standard con fig u ra tion. Remember, this is not the only way your trans mit ter may be set up. It can be custom configured to meet your needs.
Active arming
You can activate, or arm, the system by pressing transmitter for one second. When the system arms, you will hear a short siren sound, or chirp, and the parking lights will flash once. If the vehicle’s power door locks have been connected to the system, the doors will lock. While the system is armed, the status LED will flash approximately once per second, indicating that the system is actively protecting your vehicle. If you hear a second chirp after arming, and see the status LED flashing in groups, refer to the Diagnostics section of this guide. This extra chirp is called Bypass No ti fi ca tion.
Passive arming
The system also can be programmed to arm itself automatically (called passive arming). If the system is programmed for passive arming, it will automatically arm 30 seconds after the ignition is turned off and the system “sees” you leave the vehicle by open­ing and closing a door. Whenever the system is in its 30-second passive-arming countdown, the status LED will flash twice as fast as it does when the system is armed. The siren will chirp one time 20 seconds after the last door has been closed. The system is not actually armed at that point. The system arms and the doors lock (if connected and programmed for passive locking) at the 30 second mark, but the siren will not chirp. The early chirp provides you with a 10-second warning prior to arming.
8
© 2008 Directed Electronics- All rights reserved.
on your
If any protected entry point (such as a door or a switch-protected trunk or hood) is open, the system will not passively arm (unless forced passive arming is programmed on). See Pro gram ming Op­tions section of this guide. Additionally, each time a protected entry is triggered during the arming countdown, the 30-second countdown starts over.
When armed, your vehicle is protected as follows:
Light impacts will trigger the Warn Away
®
signal. When trig­gered, the siren will chirp and the parking lights will flash for a few seconds. Heavy impacts will trigger the system. The triggered sequence is between 1-180 seconds of constant siren and flashing parking lights. If a door is opened, the system will immediately start chirping the siren and flashing the parking lights. Three seconds later, the siren output changes to a con tin u ous blast. This pro gres sive re sponse gives you time to dis arm the sys tem with your transmitter if you inadvertently open the door while the sys tem is armed, while still providing an instant response (even if the door is im me di ate ly closed).
Turning on the ignition key will trip the same two-stage response as opening a door.
The optional starter kill prevents the vehicle’s starter from crank­ing.
© 2008 Directed Electronics - All rights reserved.
9
Multi-level security arming
The Multi-Level Security Arming feature is available with the four­button transmitter only.
Multi-Level Security Arming allows you to select which of the se­curity system’s inputs or sensors are to be active and which are to be bypassed, when arming the system. (See the Table of Zones section of this guide.)
Pressing
again within five seconds of arming the security
system will activate the Multi-Level Security Arming feature.
Each time
is pressed again, a different security level is se-
lected. The different security levels can be selected as follows:
Press •
once: The siren chirps once. The system is
armed.
Press •
twice within five seconds: The siren chirps twice
followed by a long chirp. Zone 2 is now bypassed.
Press •
three times, within five seconds the siren chirps three times followed by a long chirp. Zone 4 is now by­passed.
Press •
a fourth time within five seconds: The siren chirps four times followed by a long chirp. Zones 2 and 4 are now bypassed.
Press •
a fifth time within five seconds: The siren chirps five
times followed by a long chirp. All input zones, except the
10
© 2008 Directed Electronics- All rights reserved.
Loading...
+ 28 hidden pages